Hanwha Techwin Clarius PLUS User manual

A complete range in Infra-Red and White-Light illuminators for CCTV, the
visible and Invisible range feature state of the art technology and installation
friendly design.
•Energy efcient, low voltage operation for quick and easy installation
• Dual Core® LED technology with advanced electronic control circuitry
deliver improved thermal management, long life and low cost of
ownership.
• CleanLITE® self cleaning lens coating technology
• Semi covert, covert and visible White-Light versions
• Built in photo cell
•Easy integration with day/night cameras with relay contacts indicating if
the built in photo cell has activated the illuminator
• Remote telemetry input
•Easy access to power and photo cell adjust
•Pressure equalisation vent prevents thermal expansion and pressure
cycling
• Interchangeable lens diffuse technology
Note:
•Installation should be done by skilled personnel or under supervision of
such personnel
•The illuminator is low voltage 12-32V DC or 24V AC.
• Only to be installed in restricted Access Areas.
•Terminal block not included. Installation may require advice from a
qualied person.
Optimum results are achieved by setting up at night and viewing the results
on a monitor.
1. Attach the illuminator mount to pan/tilt unit, wall or camera housing.
Using stainless steel xings suitable for the relevant application.
2. Connect the lamp to a suitable (SELV) low voltage supply. Ensure that
the polarity is correct.
3. Commission the mains supply, camera and monitoring equipment.
4. Select the diffuser angle sheet required from the Clarius box (if required).
To position the required diffuser sheet, insert the tool included in the slot
at the bottom of the cover and prise upwards slowly. Repeat at opposite
end and carefully remove cover. Remove backing sheet from the two
adhesive discs and secure required diffuser in position. Finally rmly clip
the lens cover back into place.
5. Adjust the pan angle of the illuminator to match the camera eld of view.
6. Adjust the vertical alignment by loosening the side bolts (one on each
side of the main body) to maximise the results.
7. Tilt the lamp downwards until the rear part if the required eld of view is
saturated with light, as viewed on the monitor.
8. SLOWLY and GRADUALLY tilt the lamp upwards until the for part of the
required eld of view is illuminated correctly on the monitor.
RISK
GROUP 2
CAUTION
IR emitted
from this
product
Electronics High efciency surface mount high power LEDs with
advanced current limited integral control circuitry
Beam Angles 10º, 30°, 60° & 95°
Lens/Beam Pattern The illuminator should be matched to the scene and
the camera lens focal length
Wavelength 850nm and visible white light 940nm and visible white
light
Expected Life 10 years
Consumption 15W
26W
39W
SECL-IRxxx-xx-S/SECL-WLxxx-xx-S
SECL-IRxxx-xx-M/SECL-WLxxx-xx-M
SECL-IRxxx-xx-L/SECL-WLxxx-xx-L
SECL-IRxxx-xx-XL/SECL-WLxxx-xx-XL 52W
Input Voltage 12-32V DC or 24V AC 50-60 Hz
Operating Temp -50° to 50° (-58° to 122°F)
Environmental IP66. Suitable for indoor and outdoor use
Construction Robust high quality aluminium extrusion
Front Window Polycarbonate high transmittance protection (vandal-
proof) with CleanLITE®technology
Dimensions SECL-IRxxx-xx-S/SECL-WLxxx-xx-S 68 x 110 x 78mm
SECL-IRxxx-xx-M/SECL-WLxxx-xx-M 114 x 110 x 78mm
SECL-IRxxx-xx-L/SECL-WLxxx-xx-L 161 x 110 x 78mm
SECL-IRxxx-xx-XL/SECL-WLxxx-xx-XL 213 x 110 x 78mm
Weight SECL-IRxxx-xx-S/SECL-WLxxx-xx-S 750g (1.6lbs)
SECL-IRxxx-xx-M/SECL-WLxxx-xx-M 1.05kg (2.3lbs)
SECL-IRxxx-xx-L/SECL-WLxxx-xx-L 1.35kg (3lbs)
SECL-IRxxx-xx-XL/SECL-WLxxx-xx-XL 1.75kg (3.9lbs)
Power Cable 3m (9ft). Other lengths available to order
Mount Black power coated stainless steel wall mount.
Adjustable via M6 Allen Key (included)
Clarius® PLUS
Infrared & White Light LED Illuminators
SECL-IR850-DC-S
SECL-IR850-DC-M
SECL-IR850-DC-L
SECL-IR850-DC-XL
SECL-IR850-POE-S
SECL-IR850-POEPL-M
SECL-IR940-DC-S
SECL-IR940-DC-M
SECL-IR940-DC-L
SECL-IR940-DC-XL
SECL-IR940-POE-S
SECL-IR940-POEPL-M
Quick Installation Guide
SECL-WL928-DC-S
SECL-WL2300-DC-M
SECL-WL2784-DC-L
SECL-WL3712-DC-XL
SECL-WL928-POE-S
SECL-WL1856-POEPL-M
SPECIFICATION
DESCRIPTION
INSTALLATION

Power Adjust
To adjust the power, rst unscrew the sealing cap then adjust the power potentiometer
clockwise to increase the power and counter clockwise to turn it down. The unit is factory
set to maximum output.
Photocell
The photocell is designed to automatically switch the lamps on at dusk and turn off at
dawn. A high degree of hysteresis is incorporated to void on/off switching in marginal
conditions. The unit is factory set at approximately 30 Lux On and 70 Lux Off, but can be
adjusted.
Photocell Sensitivity
To adjust the photocell sensitivity rst remove the sealing cap, then adjust the
potentiometer to turn the lamp on when lighting conditions are lighter or darker. Adjust
the counter clockwise to make the lamp turn on when it is lighted and clockwise when it’s
darker.
Disabling the photocell
To disable the photocell, adjust the sensitivity fully counter clockwise. This will make the
lamp turn on at all times.
PoE Models
The Clarius PoE/PoE+ series illuminators are powered by Power over Ethernet (PoE) via
a network cable connector to a PoE IEEE802af/IEEE802at compliant switch.
The power consumption of the illuminators comply with PoE IEEE802af and IEEE802at.
These illuminators are not supplied with a power cord. Instead, they are supplied with
a 2.5m (8’) long network cable. At the end of the network cable is a female RJ45 Cat5e
compliant connector with an IP68 rated cover.
The IP68 rated cover is supplied with the illuminator. Follow the instructions supplied with
the cover on how to attached if to the male Cat5e network cable.
ENSURE THAT THE IP68 RATED COVER IS CORRECTLY FITTED AND ATTACHED
TO THE NETWORK CABLE. IF THIS IS NOT FITTED CORRECTLY MOISTURE CAN
GET INTO THE CONNECTOR AND MAY CAUSE THE UNIT TO MALFUNCTION. THIS
WOULD VOID THE WARRANTY ON THE PRODUCT.
Use suitable IP66 rated enclosure and terminal block for connection conforming to
EN60998-2-1 or EN60998-2-2
Recommended PSU
SECL-IRxxx-xx-S/SECL-IRxxx-xx-M , SECL-WLxxx-xx-S/SECL-WLxxx-xx-M : 24V 30W
(SECL-PSU-30W)
SECL-IRxxx-xx-L/SECL-IRxxx-xx-XL , SECL-WLxxx-xx-L/SECL-WLxxx-xx-XL : 24V 60W
(SECL-PSU-60W)
Use only with Class 2 power supply.
SELV Power supply should be approved to relevant EN Safety standards.
SELV Power supply should be used with devices to protect against short circuits and
overload.
Remote Switching
The Illuminator may be activated remotely by a volt-free contact latched across the
telemetry wires (see Diagram above).
Photocell following contact
Volt-free relay contact-normally open (day) to normally closed (night). See diagram above.
Trouble Shooting
Ensure all tests are undertaken by a qualied, trained engineer and ensure
safe working practices are followed at all times.
Step 1: Basics
•Check power connection
•Ensure power is 12-32V DC / 24V AC 50-60Hz
•Check the photocell is working - cover photocell, light should turn on
•Ensure power supply is suitably rated to product - check the
specications
Step 2: Lamp Test
•Check current draw of lamp corresponds to specication
•Check current of lamp - see instructions for correct current settings
To check lamp current remove +ve (red) lead from power supply and connect
a multimetre (set to 10A) in line with the lamp. (One lead of multimeter in
common (COM) other lead into 10A socket of multimeter; set multimeter to
read Amps). Refer to PSI Specications for correct current settings.
Step 3: Set up Camera, lens and Illumination
•Check alignment of lamp
•Check camera lens- fully open at night and set correctly
•Check model number to performance specication to ensure required
distance is achievable
Step 4: Call for further assistance
If the lamp is still not delivering the required performance, please contact
Technical Support for further assistance
Note down:
• Model number and serial number of illuminator
•Camera make and model
•Lens make and model
mount
Pot for photocell
adjustment
Pot for power
adjustment
Pressure relief
valve
Power and
control cable
White. Volt Free / Night Switching (N/O)
Yellow. Volt Free/ Night Switching (COM)
Green Telemetry -
Blue Telemetry +
SELV
PSU
MAINS
INPUT
Camera
Day/Night switching
(60V, 0.2A)
External circuits used for interfacing with the illuminator (Camera Day/Night
switching and Telemetry) should be reinforced/double insulated from mains.
This product complies with the European Directive 2014/30/EU
Electromagnetic Compatibility and 2014/35/EU Low Voltage Directive by
meeting the following standards:
CE-EMC EN 61547
EN 55015
EN 62493
EN 50130-4
(Lighting-Immunity)
(Lighting-Emission)
(Lighting -EMF)
(Alarm-EMC)
CE-LVD EN 60598-1
EN 60598-2-1
(Luminaires-General)
(Luminaires)
Safety EN 62471 Risk
group 2
(LED safety)
Environmental IEC/EN 60529
EN50130-5
IP66
(Alarm-environmental)
USA FCC, Class B
AUS RCM (AS/NZS CISPR 22 Class B)
RoHS: Restriction of Hazardous Substances European directive
202/95/EC
Certications
WEEE: Waste Electrical & Electronic Equipment European directive
202/96/EC
Safety Warning
• When the lamp is running, it is hot to touch. before touching switch off the illuminator and allow
to cool for a minimum of 10 minutes.
• The illuminator should be positioned so that prolonged starring into the illuminator at a
distance closed than 1m is not expected.
• The light source of this illuminator is not replaceable, when the light source reaches its end of
life the whole illuminator should be replaced.
• If the exible power cord of the illuminator is damaged it should be exclusively replaced by an
authorised service agent.
• This equipment is not suitable for use in locations where children are likely to be present.
POWER AND CONTROL CABLE CONNECTIONS
CERTIFICATIONS
This symbol on the product means that the electrical and/or electronic
equipment to which it relates should be disposed of at the end of life
separately from domestic household waste.
There are separate collection systems for recycling in the EU. For more
information please contact the Local Authority or supplier of the product.
This manual suits for next models
18
Popular Lighting Equipment manuals by other brands

INNR
INNR SP 240 manual

Black & Decker
Black & Decker BDCFSL01 instruction manual

NORLUX
NORLUX Sircular installation manual

Chauvet Professional
Chauvet Professional COLORado Panel Q40 user manual

Cooper
Cooper AtLite Sure-Lites SELDWA29SD installation instructions

Genaray
Genaray Mini Moon RSF-11 user manual