MK0901KE170918
Please read the safety information carefully before the use, and use the product correctly.
The alerts declared in the manual are classified into Danger, Warning and Caution according
to their importance
•Do not touch or contact the input/output terminals because they may cause electric shock.
WARNING
CAUTION
Frame
SMPS
C(0.01㎌-0.1㎌/500 V)
- noise-cancelling
condenser -
Photo
Sensor
Slim type Photo Sensor
Thank you for purchasing Hanyoung Nux products. Please read the
instruction manual carefully before using this product, and use the
product correctly. Also, please keep this manual where you can view it
any time.
INSTRUCTION MANUAL
Safety information Suffix code
Specification
DANGER
Indicates an imminently hazardous situation which,
if not avoided, will result in death or serious injury
WARNING
Indicates a potentially hazardous situation which,
if not avoided, could result in death or serious injury
CAUTION
Indicates a potentially hazardous situation which,
if not avoided, may result in minor iinjury or property damage
Model Number Contents
PY- ☐ ☐ ☐ Slim type Photo Sensor
Sensing mode T Through-beam
Sensing distance 3 3 m
Control output
N NPN open collector output
P PNP open collector output
Model
NPN PY-T3N
PNP PY-T3P
Sensing mode
Through - beam
Sensing distance 3 m
Sensing object Ø5 mm min. opaque object
Min. sensing object Ø2 mm min. opaque object (3 m standard)
Hysteresis distance None
Power voltage 12 - 24 V d.c. ± 10%
Current consumption Emitter: 10 mA max. , Receiver: 15 mA max.
Control output NPN or PNP open collector output
Load current: 100 mA max. (26.4 V d.c. standard)
Residual voltage - NPN: 1V max. , PNP: 1V max.
Operation mode Light ON / Dark ON mode switching selection by control wire (receiver only)
Response time 1 ㎳ max.
Light source
(wavelength) Infrared LED (850 nm)
LED
Red LED: control output, green LED: stability indication
(However, emitter red LED: power indication)
Protecting circuit
Power reverse connection protecting circuit and
output break overcurrent protecting circuit.
Output break (note 1), output failure (note 2) notification functions
Ambient illumination Sunlight : 11,000 Lux max. , Incandescent lamp : 3,000 Lux max.
Ambient temperature -20 ~ 60
℃
(storage ambient temperature : -25 ~ 70
℃
)
Ambient humidity 35 ~ 85 % RH (without condensation)
Protection rating IP 67 (IEC)
Insulation resistance 20 MΩ min. (500 V d.c. mega standard)
Noise immunity Square wave noise by noise simulator (pulse width: 1 μs) ± 240 V
Dielectric strength 1,000 V a.c. (50/60 ㎐ for 1 minute)
Vibration resistance 10 - 55 ㎐, double amplitude: 1.5 ㎜, for 2 hours in X, Y ,Z directions
Shock resistance 500 ㎨, 3 times in each X, Y,Z directions
Certifications
Connection method Wire extended type
Connection
specifications Ø3 mm, 4-core, 2 m (emitter: Ø3 mm, 2-core, 2 m)
Materials Case : PC, Lens : PC
Weight approx. 66g
DANGER
(Note 1) Red LED turns off and repeats for 38.4 ms after red LED turns on for 192 ㎲ during light ON
(Note 2) Red LED turns off after red LED turns on for 49 ms during light ON
PY series
•This product is not for outdoor use (it may shorten the product lifetime and cause electric shock)
•Do not use this product in places with flammable or explosive gases (it does not have
an explosion-proof structure, so there are fire or explosion risks)
•Do not use the product in places where vibrations or shocks exceed the reference values
(it has a double insulation structure, but the components may be damaged)
• When the lens of the photo sensor is contaminated by foreign substances, use a dry
piece of cloth and wipe off the substance lightly. Never use thinner or organic solvents.
•Separate high voltage cable and power line from the sensor wire. Be cautious since using the
same pipe during wiring could cause malfunction.
•This product has IP67 protection rating , which means that it is partially waterproof, but it
cannot be used in places that are constantly flooded.
• If the cable needs to be extended, use over 0.3 ㎟ and be cautious because of a
possible sudden voltage drop.
•When using the sensor under lights with high frequency, such as fluorescent lamps or mercury
lamps, block it with a light shading plate and avoid the lens from facing the light directly.
•Malfunction can occur due to mutual interference when using more than 2 pairs of through-
beam type photo sensors. Therefore, leave enough space for the mutual separation
distance and install the light emitters and the light receivers in alternating positions.
• Using inductive load (relay, coil) for the output can cause an instantaneous increase in
load by more than two times and damage the TR of the output. Therefore, please set
half of the maximum load.
• There is an over-current protecting circuit within the output side that breaks the output when the
current is higher than the rated load current. Therefore, please set within 70% of the maximum load.
• Do not use the product in places with heavy dust or debris that can contaminate the
lenses and consequently cause malfunctions.
•
The contents of this manual may be changed without prior notification
• Any use of the product other than those specified by the manufacturer may result in
personal injury or property damage.
• When using the Switching Power Supply as power source, ground the Frame
Ground (F.G.)terminal and be sure to connect the noise-cancelling condenser
between OV and F.G. terminals
• Be sure to observe the safety precautions mentioned above as cautions to prevent product
malfunctions.
HEAD OFFICE
HANYOUNGNUX CO.,LTD
28, Gilpa-ro 71beon-gil, Nam-gu, Incheon, Korea
TEL : (82-32)876-4697
FAX : (82-32)876-4696 http://www.hynux.com