Hardi FORCE User manual

FORCE™ Boom
Operator's Manual
10637903 (10/04)


HARDI® reserves the right to make changes in design,
material, or specification without notice thereof.
HARDI®and other product names are registered trademarks of
HARDI®Inc. in the U.S. and in other countries.
FORCE™ Boom
Operator's Manual
10637903 (10/04)

2 HARDI® FORCE™ BOOM OPERATOR’S MANUAL
TABLE OF CONTENTS
1.0 INTRODUCTION........................................................................4
2.0 SAFETY INFORMATION ...........................................................5
3.0 GLOSSARY .............................................................................10
4.0 PREPARATION........................................................................11
5.0 HYDRAULIC HOOK-UP ..........................................................11
5.1 HZ Hydraulics Joystick Controls..................................12
5.2 ‘DH’ Hydraulics (Optional) ...........................................13
6.0 OPERATING THE HYDRAULIC FORCE™ BOOM .................14
6.1 Releasing The FORCE™ Boom From Transport
Supports......................................................................14
6.2 Unfolding And Folding the Boom.................................15
6.3 Tilting Boom ................................................................17
7.0 ADJUSTMENTS ......................................................................18
7.1 Adjustment And Maintenance Intervals ......................18
7.2 Boom Adjustments and Alignments ............................19
7.3 Boom Transport Adjustments ......................................27
7.4 Boom Wheel Position ..................................................29
7.5 Boom Hydraulic Adjustments......................................30
8.0 MAINTENANCE.......................................................................32
8.1 Greasing the Paralift™................................................32
8.2 Lubrication of the Lift Frame .......................................32
8.3 Greasing the Center Frame ........................................33
8.4 Greasing The Boom ....................................................33
8.5 Greasing The Breakaway Clutch.................................34
8.6 Maintenance of Boom Wheel ......................................34
8.7 Dampening Cylinder ...................................................35
8.8 Nozzle Filters ..............................................................36
8.9 In-Line Filters (Optional)..............................................36
8.10 Nozzle Tubes And Fittings...........................................36
8.11 Maintenance Of Triplets ..............................................37
8.12 Outer Wing Shear Pin .................................................38
9.0 TRANSPORTATION AND STORAGE .....................................39
9.1 Follow Safe Transport And Towing Procedures...........39
9.2 Winter Storage ............................................................40
10.0 TROUBLESHOOTING .............................................................41
10.1 Hydraulic Systems ......................................................41
10.2 Mechanical Problems..................................................42
10.3 Hydraulic Schematics..................................................43
11.0 WARRANTY POLICY AND CONDITIONS..............................45
12.0 NOTES ....................................................................................47

3HARDI® FORCE™ BOOM OPERATOR’S MANUAL
Dear Owner,
Thank you for purchasing a HARDI®product and welcome to the ever-
increasing family of HARDI®sprayer owners.
Our sprayers and accessories are rapidly becoming a familiar sight
on North American farms. We believe that this results from growers
becoming increasingly conscious of crop protection input costs and the
vital need for cost effective application equipment.
Please take the time to thoroughly read the Operator’s Manual before
using your equipment.You will find many helpful hints as well as
important safety and operation information.
Some of the features on your FORCE™ boom were suggested by
growers. There is no substitute for “on farm” experience and we invite
your comments and suggestions. If any portion of this instruction book
remains unclear after reading it, contact your HARDI®dealer or service
personnel for further explanation before using the equipment.
For Product, Service or Warranty Information:
- Please contact your local HARDI®dealer.
To contact HARDI®directly:
- Please use the HARDI®Customer Service number: 1-866-770-7063
HARDI®INC. Visit us online at: www.hardi-us.com
Sincerely,
Tom L. Kinzenbaw
President
HARDI®MIDWEST
1500 West 76th St.
Davenport, Iowa 52806
Phone: (563) 386-1730
Fax: (563) 386-1710
HARDI®GREAT LAKES
290 Sovereign Rd.
London, Ontario N6M 1B3
Phone: (519) 659-2771
Fax: (519) 659-2821
HARDI® WEST COAST
8550 W. Roosevelt Avenue
Visalia, California 93291
Phone: (559) 651-4016
Fax: (559) 651-4160

4 HARDI® FORCE™ BOOM OPERATOR’S MANUAL
1.0 INTRODUCTION
The HARDI®FORCE™ boom is constructed from a 3-dimensional
design offering exceptional strength, stability and low maintenance.
80', 88' and 90' FORCE™ booms have Bi-fold wings (also 110' prior to
2002), while 100', 120' and 132' FORCE™ booms have Tri-fold wings.
The trapeze and link arms make the FORCE™ boom friction free with
less service and wear on the parts.
The FORCE™ boom is offered with an HZ type of hydraulic system
that features simultaneous inner wing fold and outer wing fold as well
as individual wing tilt. For "closed center" tractor hydraulics systems, an
optional "DH" (Direct acting Hydraulics) control box is available. Both
systems require one single acting and one double acting hydraulic
outlet on the tractor and a 12V-power supply for the in-cab mounted
controls.
The FORCE™ boom is fitted with triplet nozzle bodies that can be set
up for a variety of spraying applications.
HARDI®FORCE™ Boom (110’ shown)
Fig. 1

5HARDI® FORCE™ BOOM OPERATOR’S MANUAL
2.0 SAFETY INFORMATION
WARNING
ALWAYS READ OPERATOR’S MANUAL BEFORE
USING EQUIPMENT
DO NOT REMOVE ANY SAFETY DEVICES OR
SHIELDS. NEVER SERVICE, CLEAN OR REPAIR A
MACHINE WHILE IT IS OPERATING
WARNING
ALWAYS WATCH FOR THIS SYMBOL TO POINT OUT
IMPORTANT SAFETY PRECAUTIONS
IT MEANS ATTENTION! BECOME ALERT!
YOUR SAFETY IS INVOLVED!

6 HARDI® FORCE™ BOOM OPERATOR’S MANUAL
RECOGNIZE SAFETY INFORMATION
This is the Safety-alert symbol. When you see
this symbol on your machine or in this manual,
be alert to the potential for personal injury.
Follow recommended precautions and safe operating practices.
2.1 Follow Safety Instructions
- Carefully read all the safety messages in this manual and the
safety labels fitted to the machine. Keep safety labels in good
condition. Replace missing or damaged safety labels. Be sure
that new equipment components include any current safety
labels. Replacement safety labels are available from your
authorized HARDI®dealer.
- Learn how to operate the spray boom and controls properly. Do
not let anyone operate the machine without proper instructions.
- Keep your FORCE™ boom in proper working condition.
Unauthorized modifications or use may impair the function and
or safety and affect the spray boom’s life.
- If you do not understand any part of this manual and need
assistance, please contact your authorized HARDI®dealer.
2.2 Operating The FORCE™ Boom Safely
1. Read the complete manual carefully and become familiar
with the operation of the equipment before initial operation of each
spraying season. Failure to do so may result in possible over or
under application of spray solution which may drastically affect crop
production or lead to personal injury.
2. Before starting the engine on the tractor unit, be sure all
operating controls are in the off or neutral position, including (but
not limited to) the P.T.O. shaft and or spray controls. Be sure the
tractor power train is disengaged.
3. Operate spray and boom functions only when seated in the
operator’s seat.

7HARDI® FORCE™ BOOM OPERATOR’S MANUAL
4. One of the most frequent causes of personal injury or death
results from persons falling off or being run over. Do not permit
others to ride on or in. Only one person - the operator - should be
on the machine when in operation.
5. Before leaving the tractor seat, stop the engine, put all controls
in neutral, and put the transmission control lever in the park position
or neutral with the brakes locked. Read the tractor operation manual
for added safety precautions.
6. P.T.O. driven equipment can cause serious injury. Before
working on or near the P.T.O. shaft, servicing or cleaning the
equipment, put P.T.O. lever in the DISENGAGE position and stop
the engine.
7. Do not fold or unfold boom near overhead wires. Serious injury
or death could result if contact is made with electric wires.
8. Keep hands, feet & clothing away from moving parts.
9. Wear relatively tight and belted clothing to prevent from being
caught on some part of the machine.
10.Slow down when turning, especially with boom extended.
11.Always keep children away from your sprayer and/or tractor unit.
12.Before transporting the sprayer ensure that the boom is fully folded
and fully locked into transport rests and stops. Ensure all locking
devices are fully engaged whether hydraulic or mechanical.
13.Slow moving tractors and spray equipment can create a hazard
when on public roads. Avoid personal injury or death resulting from
any accidents by using flashing lights. Local regulations may require
installation of flashing warning lights.
14.Avoid injuries from high pressure fluids penetrating the skin by
relieving system pressure before disconnecting hydraulics or other
lines. Ensure all fittings are tight before applying pressure to the
system.
15.Understand service procedures before undertaking any
maintenance. Never lubricate, service, or adjust the spray boom
while its operating. Securely support any components before
working on them.
16.Keep all parts in good condition and properly installed. Fix damaged
parts immediately. Replace worn or broken parts. Remove
excessive buildup of grease, oil, or debris.

8 HARDI® FORCE™ BOOM OPERATOR’S MANUAL
2.3 Handling Chemical Products Safely
1. Direct exposure to hazardous chemicals can cause serious
injury. These chemicals can include lubricants, coolants, paints,
adhesives and agricultural chemicals. Material Safety Data Sheets
(M.S.D.S.) are available for all hazardous chemicals which inform
the user of specific details including, physical and health hazards,
safety procedures, and emergency response techniques.
2. Protective clothing such as rubber gloves, goggles, coveralls
and respirator must be worn during operation. All protective clothing
should be kept in excellent condition and cleaned regularly or
discarded.
3. If chemicals come in contact with any exposed skin areas,
wash immediately with clean water and detergent. Never place
nozzle tips or any other components that have been exposed to
chemicals to mouth to blow out obstructions. Use a soft brush to
clean spray nozzles.
4. Dedicate an area to fill, flush, calibrate and decontaminate
sprayer where chemicals will not drift or run off to contaminate
people, animals, vegetation, water supply, etc. Locate this area
where there is virtually no chance of children being in contact with
this residue.
5. Decontaminate equipment used in mixing, transferring,
and applying chemicals after use. Follow the instructions on the
chemical label for the correct procedure required. Wash spray
residue from outside of the sprayer to prevent corrosion.
6. Extreme care should be taken in measuring spray products.
Powders should be used in suitable sized packages or weighed
accurately. Liquids should be poured into a suitable graduated
container. Keep chemical containers low when pouring. Wear a
filtered respirator and let the wind blow away from you to avoid dust
and/or splashes contacting the skin or hair.
7. Store chemicals in a separate, plainly marked locked building.
Keep the chemical in its original container with the label intact.
8. Dispose all empty containers after rinsing in accordance with
local regulations & by-laws. Dispose of all unused chemicals and
left over fertilizer in an approved manner.
9. Keep a first aid kit and fire extinguisher available at all times
when handling chemicals.

9HARDI® FORCE™ BOOM OPERATOR’S MANUAL
2.4 Local Poison Information Center
If you live anywhere in the United States, the following toll free number
will connect you to your Local Poison Information Center.
PHONE NO. 1 - 8 0 0 - 2 2 2 - 1 2 2 2
If you live outside the United States, find the number for the poison
control center in your phone book and write it in the space below:
PHONE NO. ____________ -____________ - ___________________
Keep a list in the space provided below, of all the chemicals that you
have in use.
1. __________________________________________________
2. __________________________________________________
3. __________________________________________________
4. __________________________________________________
5. __________________________________________________
6. __________________________________________________
7. __________________________________________________
8. __________________________________________________
9. __________________________________________________
10. __________________________________________________

10 HARDI® FORCE™ BOOM OPERATOR’S MANUAL
3.0 GLOSSARY
1.)
RIGHT HAND & LEFT HAND SIDES-
Are determined by facing
forward in the direction of travel.
2.)
HZ MODEL-
A FORCE™ boom with advanced hydraulics.
This boom can raise and lower, fold inner or outer wings
simultaneously, and tilt each wing individually.
3.)
FOLDED BOOM-
Refers to the boom in transport position.
4.)
UNFOLDED BOOM-
Refers to the boom in spraying position.
5.)
WING-
Refers to the folding portion of the boom.
6.)
LIFT FRAME-
Mounts to the upper and lower parallelogram arms,
also called the Paralift™.
7.)
CENTER SECTION-
Refers to the portion of the boom that the
wings attach to. The wings move up and down with the center.
8.)
LINK ARMS-
Attaches the Center Section to the Lift Frame,
together with the trapeze arms.
9.)
INNER WING-
Refers to the inner portion of the wing.
10.)
INTERMEDIATE WING-
Refers to the intermediate portion of the
wing (only on tri-fold configurations - 100', 120' & 132').
11.)
OUTER WING-
Refers to the outer portion of the wing.
12.)
BREAKAWAY-
Refers to the part of the wing that allows
movement in the event of striking an object.
A - Breakaway Section
B - Outer Wing Section
C - Intermediate Wing Section (tri-fold 100', 120' & 132' only)
D - Inner Wing Section
E - Center Frame
C
AB
D
E
Fig. 2

11HARDI® FORCE™ BOOM OPERATOR’S MANUAL
4.0 PREPARATION
The FORCE™ booms need one single outlet for the lift function of the
spray boom and one double outlet for the folding and the tilt function.
Note that the booms hydraulic system requires an oil capacity of
approximately 1.5 GPM (5.7 liters/min.) and a minimum pressure of
2,100 PSI (145 bar).
5.0 HYDRAULIC HOOK-UP
WARNING:
• BE SURE TO HOOK UP HYDRAULIC LINES
PROPERLY !
• MAKE SURE THE HYDRAULIC LINES HAVE NOT
BEEN DAMAGED DURING SHIPPING.
• ESCAPING HYDRAULIC FLUID UNDER PRESSURE
CAN PENETRATE THE SKIN CAUSING SERIOUS
INJURY. AVOID THIS HAZARD BY RELIEVING
PRESSURE BEFORE DISCONNECTING HYDRAULIC
LINES.
• ENSURE ALL CONNECTIONS ARE TIGHT BEFORE
APPLYING PRESSURE. SEARCH FOR LEAKS WITH
A PIECE OF CARDBOARD, NOT YOUR HANDS!
• IMPROPER HOOK-UP CAN CAUSE DANGEROUS
BOOM MOVEMENTS AND/OR DAMAGE TO THE
SPRAYER HYDRAULICS.
• DO NOT ALLOW ANYONE NEAR A HYDRAULIC
BOOM IN OPERATION.
• ALWAYS SHUT TRACTOR OFF WHEN CONNECTING,
SERVICING OR ADJUSTING BOOM.
IMPORTANT:
Due to the wide variations in tractor hydraulic
systems and capacities, care should be exercised when initially
operating the sprayer hydraulic cylinders. It is advisable to adjust
the hydraulic flow control down to the minimum rate before
operating the system. Adjust/increase the flow control after the
system is bled of any air, if necessary.
1. Attach the larger (3/8“) hydraulic hose to the tractor's single
acting outlet.
2. Attach the smaller (1/4“ ) hydraulic hose to the tractor's double
acting outlet.

12 HARDI® FORCE™ BOOM OPERATOR’S MANUAL
5.1 HZ Hydraulics Joystick Controls
Switch Aoperates: Left hand fold cylinder
Switch Boperates: Right hand fold cylinder
Switch Coperates: Left hand tilt cylinder
Switch Doperates: Right hand tilt cylinder
Installation Of Handle
1. Attach the control handle to the hydraulic lever that operates
the double acting outlet you intend to use (Fig. 3). The universal
mounting bracket (E)(Fig. 3) is very flexible and a number of
different mounting positions can be used.
2. Connect plug (F)(Fig. 3) to the tractor's 12V power system.
Try to hook up the handle as close as possible to the battery or
the starter for a better power supply. HARDI®recommends using
electric distribution box #817925 to insure a good power supply to
various 12V attachments.
Note: Check with your dealer or tractor operator's manual for the
best location to hook up the 12V system.
NOTE POLARITY:
BROWN WIRE = POS (+)
BLUE WIRE = NEG (-)
3. Connect electric plug (H)(Fig. 3)
from sprayer hydraulics to plug (G)(Fig. 3)
on handle.
Fig. 3

13HARDI® FORCE™ BOOM OPERATOR’S MANUAL
Fig. 4
5.2 ‘DH’ Hydraulics (Optional)
Note: This kit can only be used on tractors with 'closed center'
hydraulic systems.
Switch Aoperates: Left hand fold cylinder
Switch Boperates: Right hand fold cylinder
Switch Coperates: Left hand tilt cylinder
Switch Doperates: Right hand tilt cylinder
Installation Of The 'DH'Hydraulic Switch Box
1. Remove the joystick control handle complete with
bayonet style 12V plug and 7 pin female plug (if
previously fitted).
2. Route the cable, with the 7 pins, from the hydraulic mount plate
to the tractor.
3. Mount the 'DH' hydraulic switch box in a suitable location in the
tractor cab.
4.
Connect the bayonet plug (E)(Fig. 4) from the switch box to a
12V power supply. HARDI®recommends using electronic distribution
box #817925 to ensure a good power supply to various 12V
attachments.
NOTE POLARITY: BROWN WIRE = POSITIVE (+)
BLUE WIRE = NEGATIVE (-)
5. Connect the female 7 pin plug (F)(Fig. 4) from the switch box to
the 7 pin male plug from the hydraulic mount plate on the sprayer.

14 HARDI® FORCE™ BOOM OPERATOR’S MANUAL
6.0 OPERATING THE HYDRAULIC FORCE™ BOOM
WARNING:
USE EXTREME CAUTION THE FIRST SEVERAL TIMES
YOU OPERATE THE BOOM AS THE AIR IS BLED OUT.
• AIR MAY STILL BE TRAPPED IN THE HYDRAULICS
SYSTEM. THE BOOM CAN MAKE SUDDEN AND
UNEXPECTED MOVEMENTS!
• ALWAYS OPERATE BOOM ON LEVEL GROUND.
• BEFORE UNFOLDING THE BOOM, ENSURE THAT
THE SPRAYER IS HITCHED TO THE TRACTOR UNIT.
• ENSURE THAT THERE ARE NO OBSTRUCTIONS
OR PERSONS IN THE PATH OF TRAVEL BEFORE
FOLDING OR UNFOLDING THE BOOM.
• NEVER FOLD/UNFOLD THE INTERMEDIATE OR
OUTER WINGS WITH THE INNER WINGS TILTED.
• NEVER DRIVE AND FOLD/UNFOLD THE BOOM AT
THE SAME TIME.
6.1 Releasing The FORCE™ Boom From Transport Supports
WARNING:
ALWAYS FOLD/UNFOLD BOOM ON LEVEL GROUND
WITH A MINIMUM GROUND CLEARANCE OF 6 FEET,
AND A MINIMUM REAR CLEARANCE OF 22 FEET!
1. Start tractor and bring engine to operating RPM.
2. Activate the single acting outlet to lift the boom out of the sprayer’s
transport support.
Note: When raising the boom from the transport supports,two hooks
will also be disengaged from the two Paralift™ cylinders. (As
shown in Fig. 5).
Fig. 5

15HARDI® FORCE™ BOOM OPERATOR’S MANUAL
6.2 Unfolding And Folding The Boom
A) Hydraulic Joystick Controls
TO UNFOLD BOOM
1.
Raise the boom to the highest point to release the transport hooks and
transport supports (Section 6.1).
2. Depress switch (A)(Fig. 6) and move the joystick forward or rearward
to unfold the inner wing sections of the boom. Switch position of the
hoses in the double acting remote outlet if you do not like the direction
required to activate the boom.
Note: When unfolding the inner wings, the transport hooks on the
two Paralift™ cylinders will disengage
3. With the boom still at the highest point, depress switch (B)(Fig. 6) to
unfold the outer wing sections (unless spraying half folded). For tri-fold
booms (100', 120' or 132') depressing switch (B)(Fig. 6) will unfold the
intermediate wing sections first, followed by the outer wing sections.
Lower boom to desired spray height.
TO FOLD BOOM
1.
Raise the boom to the highest point.
2. Depress switch (B)(Fig. 6) and move joystick in opposite direction
as unfold to fold in the outer wing sections. For tri-fold booms (100',
120' of 132'), depressing switch (B)(Fig. 6) will fold in the outer wing
sections first, followed by the intermediate wing sections.
Note: Be sure that the boom is raised when folding, or damage can
occur when the transport hooks are engaged.
3. Tilt wings up approx. 15° (Section 6.3).
4. Depress switch (A)(Fig. 6) to fold in the
inner wing sections allowing the bottom
profile of the wing to come in contact
with the vertical part of the front transport
bracket.
5. Lower boom down, activating the Paralift™ lift
cylinders. Make sure that the transport hooks
are engaged on the cylinders. Then lower the
tilt cylinders (switches Cand D)(Fig. 6)
until the wings are resting on the front
transport supports.
6. Relieve all oil out of the system by
activating the tractor levers without
any switches pushed.
Fig. 6

16 HARDI® FORCE™ BOOM OPERATOR’S MANUAL
Fig. 7
B) "DH" Hydraulics Control Box (Optional)
TO UNFOLD BOOM
1.
Raise the boom to the highest point to release it from the transport
supports and hooks (Section 6.1).
2. Engage the tractor's double acting remote outlet lever and lock it in
the engaged position.
3. Activate switch (A)(Fig.7) upwards
and hold to unfold the inner wing
sections.
Note: When unfolding the inner
wings, the transport hooks on
the two Paralift™ cylinders
will disengage.
4. Activate switch (B)(Fig. 7) upwards and hold to unfold
the outer wing sections (unless spraying half folded).
For tri-fold booms (100', 120' or 132') activating switch
(B)(Fig. 7) will unfold the intermediate wing sections
first, followed by the outer wing sections. Lower boom
to desired spray height.
TO FOLD BOOM
1.
Raise the boom to the highest point.
2. With the double acting remote outlet lever engaged, activate switch
(B)(Fig. 7) downwards and hold to fold in the outer wing sections. For
tri-fold booms (100', 120' of 132'), activating switch (B)(Fig. 7) will
fold in the outer wing sections first, followed by the intermediate wing
sections.
Note: Be sure that the boom is raised when folding, or damage can
occur when the transport hooks are engaged.
3. Tilt wings up approx. 15° (Section 6.3).
4. Depress switch (A)(Fig. 7) to fold in the inner wing sections allowing
the bottom profile of the wing to come in contact with the vertical part
of the front transport bracket.
5. Lower boom down, activating the Paralift™ lift cylinders. Make sure
that the transport hooks are engaged on the cylinders.Then lower the
tilt cylinders (switches Cand D)(Fig. 7) until the wings are resting on
the front transport supports.
6. Relieve all oil out of the system by activating the tractor levers without
any switches pushed.

17HARDI® FORCE™ BOOM OPERATOR’S MANUAL
6.3 Tilting Boom
WARNING:
NEVER ATTEMPT TO WORK ON OR AROUND BOOM
WHEN TILTED UP.
A) Hydraulic Joystick Controls
1. Activate switch (C)(Fig. 8) and move hydraulic handle forward or
rearward to tilt left hand boom up. To tilt the right hand boom, activate
switch (D)(Fig. 8). Switch positions of the hoses in the double acting
outlet if you do not like the direction required to activate the boom.
B) ‘DH’ Hydraulic Control Box (Optional)
1. Engage the tractor's double acting remote outlet lever and lock
it in the engaged position.
2. Activate switch (C)(Fig. 8) upwards and hold to tilt left hand boom
up. (Holding the switch in the down position will tilt the boom down.)
To tilt the right-hand boom activate switch (D)(Fig. 8).
Fig. 8

18 HARDI® FORCE™ BOOM OPERATOR’S MANUAL
7.0 ADJUSTMENTS
WARNING:
• HARDI®CANNOT ASSUME RESPONSIBILITY OR BE
HELD LIABLE FOR ANY LOSS OR DAMAGE THAT
OCCURS DUE TO LACK OF ADJUSTMENTS OR
MAINTENANCE.
• WE URGE YOU TO FOLLOW THE ADJUSTMENT
AND MAINTENANCE RECOMMENDATIONS FOR
EVERYONE’S SAFETY.
• MAKE IT A DAILY HABIT TO INSPECT YOUR BOOM
FOR NEED OF ADJUSTMENT OR MAINTENANCE.
• IMMEDIATELY REPLACE ANY PARTS ON THE BOOM
THAT ARE WORN OR BROKEN.
• ALWAYS CLEAN YOUR BOOM BEFORE ADJUSTING
IT TO AVOID UNNECESSARY CONTACT WITH
CHEMICALS.
Your new HARDI®FORCE™ boom was hydraulically charged and
adjusted at time of assembly (This applies to booms sold with sprayers
as complete units only.) Fold and unfold the boom several times
before making adjustments to remove all air from the hydraulic circuit.
It is important that the hydraulic cylinders remain extended during
adjustments with the boom open.
The FORCE™ boom will require additional adjustments shortly after
being put into use and at regular intervals thereafter. It is important to
perform the adjustment procedures in the same sequence as they are
written in this manual.
To further ensure proper performance, the FORCE™ boom also has
to be maintained on a regular basis. Please follow the suggested
maintenance intervals (Section 8.0).
7.1 Adjustment And Maintenance Intervals
IMPORTANT:
To maximize boom life and performance, retighten
all boom fasteners and inspect boom for proper adjustment after
the first 10 hours of use. Thereafter adjust the boom at least once
a year and check all fasteners at 50 hr. intervals. Lubrication of the
boom should be done daily to ensure maximum performance and
life. (Section 8.0)
Table of contents
Other Hardi Boom Lift manuals