Harman® • Allure50 Installation Manual_R2 • 2016 - ___ • 09/1619 3-90-888000i
H. Avoiding Smoke and Odors
Negative Pressure, Shut-down, and Power Failure:
To reduce the probability of back-drafting or burn-back in
the pellet burning appliance during power failure or shut-
down conditions, the stove must be able to draft naturally
withoutexhaustbloweroperation.Negativepressureinthe
housewillresistthisnaturaldraftifnotaccountedforinthe
pelletapplianceinstallation.
Heatrisesinthehouseandleaksoutatupperlevels.This
airmustbereplacedwithcoldairfromoutdoors,whichows
into lower levels of the house. Vents and chimneys into
basementsandlowerlevelsofthehousecanbecomethe
conduitforairsupply,andreverseundertheseconditions.
Outside Air
Anoutsideair kit isrecommendedinall installations.The
OutsideAirKitmustbeorderedseparately.
Pernationalbuildingcodes,considerationmustbegivento
combustionairsupplytoallcombustionappliances.Failure
tosupplyadequatecombustionairforallappliancedemands
mayleadtobackdraftingofthoseandotherappliances.
Whentheapplianceisroofvented(stronglyrecommended):
Theairintakeisbestlocatedontheexteriorwalloriented
towardstheprevailingwinddirectionduringtheheating
season.
Whentheapplianceisside-wallvented:
Theairintakeisbestlocatedonthesameexteriorwall
astheexhaustventoutletandlocatedloweronthewall
thantheexhaustventoutlet.
Theoutsideairsupplykitcansupplymostofthedemands
ofthepelletappliance,butconsiderationmustbegivento
thetotalhousedemand.
House demand may consume the air needed for the
appliance.Itmaybenecessarytoaddadditionalventilation
tothespaceinwhichthepelletapplianceislocated.
ConsultwithyourlocalHVACprofessionaltodeterminethe
ventilationdemandsforyourhouse.
Vent Pipe
Besureto use approved pellet vent pipe wall and ceiling
pass-throughttingstogothroughcombustiblewallsand
ceilings.Besuretouseastartingcollartoattachtheventing
systemtothestove.Thestartingcollarmustbesecuredto
theuestubwithatleastthreescrews,andsealedwithhigh
tempsiliconecaulking.
4” stainless steel ex vent piping is only allowed for use
inmasonryreplacesandchimneysorfactorybuiltwood-
burningreplaceswithClassAmetalchimneys.
Pelletventingpipeisconstructedoftwolayerswithairspace
betweenthelayers.Thisairspaceactsasaninsulatorand
reducestheoutsidesurfacetemperaturetoallowaclearance
to combustibles of only 1 inch. The sections of pipe lock
togethertoformanairtightsealinmostcases;however,in
somecasesaperfectsealisnotachieved.Forthisreason
andthefactthattheAllure50operateswithapositivevent
pressure, we specify that the joints also be sealed with
siliconeoraluminumtapeinadditiontothesealingsystem
usedbythemanufacturer.
Wherepassingthroughanexteriorwallorroof,usesilicone
tomaintainaneffectivevaporbarrieratthelocationwhere
thechimneyorcomponentpenetratestotheexteriorofthe
structure.
Vent Congurations:
To reduce probability of reverse drafting during shut-
down conditions, Hearth & Home Technologies strongly
recommends:
• Installingthepelletventwithaminimumverticalrunof
vefeet.
• Installingoutsideair.
Topreventsootdamagetoexteriorwallsofthehouseand
topreventre-entryofsootorashintothehouse:
• Maintainspeciedclearancestowindows,doors,andair
inlets,includingairconditioners.
• Ventsshouldnotbeplacedbelowventilatedsofts.Run
theventabovetheroof.
• Avoidventingintoalcovelocations.
• Ventsshouldnotterminateunder overhangs, decks or
ontocoveredporches.
• Maintain minimum clearance of 12 inches from the
ventterminationtotheexteriorwall.Ifyouseedeposits
developing on the wall, you may need to extend this
distancetoaccommodateyourinstallationconditions.
Hearth & Home Technologies assumes no responsibility
for, nor does the warranty extend to, smoke damage
caused by reverse drafting of pellet appliances under
shut-down or power failure conditions.