HATO HT 600 User manual

1
HATO HT 600..
HT 1000
HT 1200
OPERATING MANUAL
FOR GARAGE DRIVES

2
IMPORTANT SAFETY INSTRUCTIONS.......................................................................................................................................... 3
TECHNICAL SPECIFICATION........................................................................................................................................................ 4
COMPONENTS INCLUDED IN THE SET ....................................................................................................................................... 4
ASSEMBLY .................................................................................................................................................................................. 6
DIAGRAM (optional accessories)............................................................................................................................................. 12
REMOTE CONTROLS’ PROGRAMMING.................................................................................................................................... 14
ADJUSTING THE CLOSING FORCE............................................................................................................................................. 15
ACTIVATION OF THE PHOTOCELLS FUNCTION......................................................................................................................... 15
AUTO-CLOSING FUNCTION...................................................................................................................................................... 15
GATE LOCK FUNCTION ............................................................................................................................................................. 16
VENTILATION FUNCTION ......................................................................................................................................................... 17
PEDESTRIAN MODE ................................................................................................................................................................. 17
MAINTENANCE, USE................................................................................................................................................................ 17
TABLE OF CONTENTS
ATTENTION!!!
Please read the manual carefully before installation
and use.
The installation of a new door opener must be carried
out by a technically qualified or licensed person.
Attempting to install or repair a door opener without the
appropriate technical qualifications may result in
serious personal injury, death and / or property damage.
Declaration of conformity
The Hato HT 600/1000/1200
complies with the requirements of the following regulations: It complies with the
conditions of the machinery directive 2006/42/WE Annex II, section B, as
amended.
Complies with the conditions of the following EU directives:
Directive on electromagnetic compatibility EMC 2014/30/UE
Low Voltage Directive LVD 2014/35/UE
RED radio directive 2014/53/UE
The following harmonized standards have been applied:
EN ISO 12100:2012; EN 60204-1:2010; EN 60335-2-95:2015, EN 301 489-3
V1.4.1:2006; UNI EN 12453:2002, where applicable EN 12445:2002
Access to the current declaration at the company's headquarters or download
from the manufacturer's website: www.hato.com.pl

3
IMPORTANT SAFETY INSTRUCTIONS
FAILURE TO OBSERVE THE FOLLOWING SAFETY PRECAUTIONS COULD RESULT IN SERIOUS PERSONAL INJURY, DEATH AND / OR
DAMAGE TO YOUR PROPERTY.
1. PLEASE READ CAREFULLY AND COMPLY WITH ALL SAFETY AND INSTALLATION RECOMMENDATIONS.
2. The drive has been designed and manufactured in accordance with local regulations. The installer must be familiar with local
regulations required to install the drive.
3. Unqualified personnel or persons unfamiliar with the health and safety standards applicable to automatic gates may not,
under any circumstances, install or implement systems.
4. Persons who install or service equipment without complying with all applicable safety standards are responsible for any
damage, injury, cost, expense, or claim for any person suffered as a result of improper installation of the system and in
accordance with applicable regulations. Safety standards and assembly instructions, whether directly or indirectly.
5. For greater security, we strongly recommend installing photocells. The drive is equipped with an obstacle detection system,
but the installation of photocells will significantly improve the operational safety of automatic garage doors and provide
additional security.
6. Make sure the garage door is fully open and stationary before entering or exiting the garage.
7. Make sure the garage door is completely closed and stationary before leaving the property.
8. Keep your hands and loose clothing away from the drive and garage door at all times.
9. The obstacle detection system is designed to work only on STATIONARY objects. Serious personal injury, death, and / or
property damage can occur when garage doors come into contact with a moving object
10. This device is not intended for use by persons (including children) with reduced physical, sensory or mental abilities, or
without experience and knowledge, unless they have been given supervision or instruction regarding the use of the device by a
person responsible for their safety. Children should be supervised to ensure that they do not play with the device
11. Waste electrical products should not be disposed of with household waste. Please recycle them. Contact your local
authorities or dealer for recycling advice.
12. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or a similarly qualified person in
order to avoid a hazard.
- WARNING: Important safety instructions. It is important that the people operating the gate follow the instructions.
- Do not let children play with gate remote controls. Keep the remote controls out of the reach of children.
- Be careful when the gate is moving.
- Be careful when opening the door in emergency, as the open door may fall suddenly due to weak or broken springs or when it
is not balanced.
- Check the installation frequently, especially control cables, springs, and mountings for signs of wear, damage or imbalance. Do
not use the drive when repair or adjustment is required, as an installation error or an improperly balanced door could cause
injury.
- Every month, check that the drive reverses when the door touches an object 50 mm high placed on the floor. Adjust as
necessary and check again as improper adjustment may be dangerous.
- Details on how to use the drive and adjust the door and drive are in the manual.
- Disconnect the power source when cleaning or performing other maintenance.
- The installation manual provides details on installing the drive and related components.

4
TECHNICAL SPECIFICATION
HT 600
HT1000
HT1200
Supply voltage
230V AC +/-10% 50-60Hz
Motor
24V DC
Strength
600N
1000N
1200N
Operating temperature
-20°C +50°C
Permissible humidity
≤90%
Remote control operating frequency
433,92 Mhz
Lighting
LED
Backlight time
3 minutes
Remote control range
do 30 m in open space
COMPONENTS INCLUDED IN THE SET
1. Drive head
2. Flat bar
3. Remote control (2 pcs)
4. Set of bolts and nuts
5. Warning stickers
6. User manual
7. The release line
8. Rail with chain
9. Disengagement (trolley)
10. Opening limiter
11. Bracket for the guide
12. Panel support
13. Engine bracket
14. Fixing the motor to the rail
15. Multi-wedge
4

5
1
2
3
11
12
9
13
10
14
7
15

6
ASSEMBLY
Important! Tighten the nuts before
starting the drive for the first time
Hand-tighten the motor mounts 1012d with
four nuts 1007d x4
Place the splines on the
engine pin
Tighten 4 screws
1008d x4
1019d

7
1025d x1
1015d x1
1006d x2
1007d x2
For overhead gates it is recommended to fasten the handle through with screws
Fastening the rail
to the wall
Attaching the handle
for lifting the gate

8
1025d x1
1005d x2
1007d x2
!!! The rail should be mounted
horizontally, above the guide line (min.
30mm) !!!
Mounting the rail
reinforcement
(optional)
1018d

9
Sleeve - 1001d x1
Split pin - 1002d x1
Disengagement - 1017d x1
flat bar L - 1013d x1
flat bar - 1014d x1
Nut - 1003d x2
Bolt - 1004d x2
Screw - 1008d x4
1021d x1
1022d x1
1005d x1
Installation of the maximum opening limiter
Connect the flat bar L 1013d with desengagement 1017d with metal lock 1001d i 1002d
If the length of the L 1013d flat bar is too short, it can be extended with a 1014d flat bar.
An example on the next page.
Use bolts and nuts (1003d and 1004d)

10
Example of door connection with drive disengagement:
Option 1 - when the distance between the upper edge of the
closed gate and the guide does not exceed 25 cm.
Option 2 - when the distance between the upper edge of the
closed gate and the guide exceeds 25 cm.

11
PREPARATION
1. Bracket No. 1020d should be screwed to the engine, it is used to fix the engine to the ceiling. This bracket
is not included in the kit.
2. Check that the release (trolley) is blocking the gate, manually pull the gate up and down to make sure that
the gate is engaged.
3. The garage door must be lifted and closed by hand without any great effort. A well-balanced and
positioned door is crucial for proper installation.
4. The garage door opener cannot compensate for a badly fitted garage door and should not be used as a
solution for difficult-to-open doors.
5. If the unit is installed over an existing door, make sure any existing interlocking devices are removed or
the warranty will be void.
6. The power socket must be installed close to where the drive is installed.
7. There should be a minimum distance of 30mm between the bottom of the guide and the top of the garage
door.
8. Turn on the power, the warning light will be on for a few seconds, at the same time the LED display will
count down from 99 to 11. Then the drive will go into the standby state.
9. Finally the display will show “- -“.
Important note: As far as additional safety rules are concerned, we strongly recommend the installation of garage
door photocells in all installations.
Sleeve - 1001d x1
Cotter - 1002d x1
Fastening a flat bar to the gate handle with a
steel sleeve and a cotter pin

12
DIAGRAM (optional accessories)
DIAGRAM OF CONNECTING ADDITIONAL ACCESSORIES
NC service door switch
Fuse socket
NO button
(bell)
Universal
radio
Battery
(backup power supply)
Photocell
transmitter
Photocell
receiver
24V BEACON

13
END POSITION PROGRAMMING
1.
Press and hold "P" until "P1" is displayed.
2.
Again, short press “P”, it will display “OP”.
3.
Then press and hold ▲ (the door will start to open) “OP” will flash.
4.
When the door reaches the desired opening height, immediately release
the ▲ button and confirm by pressing “P”, then “CL” will be displayed.
5.
Press and hold ▼ in sequence, (door will start closing) “CL” will blink.
When the door is closed, immediately release the ▼ button and confirm
by pressing “P”.
6.
The door will open and close automatically. By performing a control cycle
7.
When "- -" is displayed, programming is complete
From that moment on, the keyfobs (after logging in) can control the gate
Control of all functions via the
Control Panel
The remote control has four
buttons (channels). Depending on
the functions included in the
operator, the remote control can
operate from one to four different
garage doors.
With the gate and ventilation
interlocks disabled - 4 gates.
The remote control will support
only one drive when the functions
and locks and the ventilation of
the gate are activated.

14
CLEARING MEMORY OF REMOTE CONTROLS
-
Clearing the remote control’s memory should be performed when
installing the drive. This ensures that the code of any remote control
other than the one owned by the owner is not stored in the drive's
memory.
-
If you lose the remote control, you should also clear the remote control
memory.
The deletion procedure is as follows:
Press and hold "C". When “dL” blinks, all remotes have been cleared.
REMOTE CONTROLS’ PROGRAMMING
The procedure for programming (logging in) the remote controls is as
follows;
1.
Briefly press “C”, “Su” will be displayed.
2.
Press the selected key on the remote control twice - “Su”/ will quickly
blink.
3.
Then “- -“ will be displayed to let you know that programming has been
successful.
-
A maximum of 20 remote controls can be logged in. If the display
shows "Fu", it means that the remotes memory is full. Then you need
to delete the remotes memory and log in only those that are used.
Depending on which functions of the drive we are going to use, the
order in which the individual buttons of the remote controls are logged
in will be different:
A.
If we use the drive without the lock function and without the
ventilation function, then we can log any remote control channel at any
time.
In this variant, one remote control can operate four gates.
B.
If we use a drive with a lock function, without a ventilation function,
then we can log the buttons “A, B, C” at any time. The "D" buttons of
the remotes are dedicated to unlocking.
C.
If we use the drive without the lock function, with the ventilation
function, then before activating the ventilation function, log the
buttons of all remote controls intended for ventilation (according to the
procedure, points 1-2).
When the ventilation function is turned on for the first time, the
buttons of all remote controls (other than those intended for the
ventilation function) are logged in for opening and closing the gate.
D.
If we use a drive with a lock and ventilation function, then logging the
buttons is as above, excluding the "D" button. After the remote control
deletion procedure has been carried out with the ventilation function
on, we first turn off this function and log all remotes to operate this

15
function. We turn on the ventilation function and only now log the
buttons of all remote controls for opening / closing.
ADJUSTING THE CLOSING FORCE
When setting the closing force, pay attention to whether the drive closes
the gate freely, and at the same time check whether the chamber seal
has retained its geometry. In the event of encountering an obstacle
(exceeding the set force), the gate will stop and open fully immediately.
The procedure for setting the closing force:
1.
Press and hold “P”, until “P1” displays.
2.
Press “▲” once, until “P2” displays.
3.
When pressing “P” again, you will see current closing force settings.
Press “▲” to increse, or “▼” to reduce the operating force of the drive.
Maximum froce: F9, minimum F1.
4.
Press “P” to confirm settings. Default value is “F5”.
ACTIVATION OF THE PHOTOCELLS FUNCTION
Photocells are used to protect the gate during closing against hitting an
obstacle in the gate's light. In a situation where the beam of photocells
is cut, the gate will start opening immediately or, when it is fully open,
it will remain motionless.
Procedure for activating the photocells service:
1.
Press and hold “P”, until “P1” displays.
2.
Press “▲”(twice), until “P3” displays.
3.
By pressing “P” again, you will see current settings.
By pressing “▲” “H1” will display (photocell support is on)
By pressing “▼” “H0” will display (photocell support is off)
Press “P” to confrim settings.
4.
If you are not using photocells, make sure that their operation is turned
off.
AUTO-CLOSING FUNCTION
Auto-closing determines the time after which the gate, after complete
opening, starts closing. The auto-closing function, for safety reasons,
can only be activated when photocells are installed and the photocells
support function is enabled. Activating the auto-closing function
without photocells may result in an accident. If the gate is partially
open then the auto-closing function does not work.
Procedure for activating the photocells service:

16
1.
Press and hold “P”, until “P1” displays.
2.
Press “▲”(three times), until “P4” displays.
3.
By pressing “P” again, you will see current settings.
By pressing “▲” you add 1 minute, by pressing “▼” you subtract
1 minute. Maximum time is “b9”, minimum “b0”.
Press “P” to confirm settings.
4.
Default setting is “b0”- Auto-closing function disabled.
GATE LOCK FUNCTION
The gate lock function is used to prevent the gate from opening
unintentionally. (if the remote control in your pocket is accidentally
pressed, it may start the gate), after activating this function, to open
the gate, first press the button “D” and then the button logged in to
open the gate. If the interlock function is used, button "D" must not be
logged to open the gate.
The interlock function only works when the gate is completely closed. If
the gate is in a different position, to control it, use only the button
logged in to control it.
Procedure for activating the photocells service:
1.
Press and hold “P”, until “P1” displays.
2.
Press “▲”, until “P5” displays.
3.
By pressing “P” again, lock settings will appear.
By pressing “▲” “Lc” will display – the lock is on.
By pressing “▼” “uL” will display – the lock is disabled.
Press “P” to confirm settings.
4.
The interlock function works only when the gate is fully closed.
ADJUSTING THE OPENING FORCE
If there is a risk of the gate becoming jammed while it is being lifted (eg
due to the presence of objects), then the opening force must be set so
that it can rise freely and evenly. If there is an obstacle, the door stops
immediately.
Procedure for activating the photocells service
1.
Press and hold “P”, until “P1” displays.
2.
Press “▲”, until “P6” displays.
3.
By pressing “P”, you will see the current opening force settings.
Press “▲” to increase or “▼” to reduce the operating force of the
drive. Maximum force F9, minimum F1.
4.
Press “P” to confirm settings. Default valute is “F9”.

17
VENTILATION FUNCTION
If there is a need for garage ventilation, then this function can be
turned on. It consists in the fact that with the remote control button
(other than the button for opening / closing the gate) the gate is
opened to the programmed height n x 8cm (n=1÷6) .
Before activating the ventilation function, the buttons of all remote
controls must be logged in to the drive to operate this function
Activation of the ventilation function:
1.
Press and hold “P”, until “P1” displays.
2.
Press “▲” until “P7” displays.
3.
Then press ▲or▼ to adjust settings.
The displayed “r0” means that the ventilation function is disabled,
The displayed “r1” to “r6. Ventilation level [(1 to 6) x 8cm].
4.
Press “P” to confirm.
5.
After switching on the ventilation function for the first time, we need to
log in the buttons of all remote controls for opening / closing.
Subsequent activation and deactivation of this function does not require
logging in the remotes anew.
PEDESTRIAN MODE
1.
The pedestrian mode works only when the drive has the photocell support
switched on. In a situation where the garage door is open, after cutting the
photocells, the gate will start closing after a set time.
2.
Press and hold “P”, until “P1” displays.
3.
Press “▲”, until “P8” displays.
4.
Then press ▲or▼ to adjust settings.
“00” displayed – the function is blocked
“01” to ”10” displayed – set time between 1 and 10 seconds.
5.
Press “P” to confirm.
Default setting is “00”.
MAINTENANCE, USE
Attention! A poorly adjusted garage door can affect the service life of the drive due to incorrect loads and void the
warranty.
1
Check if the garage door works smoothly. (unlock the release and manually raise and lower the gate)

18
2
Connect the power supply of adequate power, the power cord must be equipped with an earthing
system.
3
Only use the remote control when the gate is in sight. Do not go under a working gate.
Remote controls should be kept out of the reach of children.
4
Make sure the door is protected against fire, moisture or strong electromagnetic fields.
5
At least twice a year, check that the gate is properly balanced, that all mechanical elements are in good
technical condition, and that the chain has the correct tension..
PROBLEM
POSSIBLE CAUSES
SOLUTIONS
Nothing is displayed on the LED display.
The gate is down.
1. No power
1. Make sure the power is on
2. Blown fuse
2. Check the fuse and, if necessary, replace
it with a new one (2.5A)
After turning the supply on, the drive
does not carry out the test (the digits
should change from "99" to "11") or
the display shows a different character.
Defective microcontroller
Send the drive to the service with a
description of the fault and the purchase
document
The gate moves slightly
End positions not set
Program the end positions anew in
accordance with the instructions
The selected button on the remote
control cannot be logged in
1. The selected button is used for the
lock function
1. Select a different button for logging in
2. Defective remote control
2. Send the remote control to the service
together with a description of the fault and
the purchase document
After programming the end position,
the actuator is inoperative
1. End positions incorrectly set
1. Re-program the end positions. Please
note that we set the top position first, and
then the bottom position. Neither position
can be set to pressure.
2. The gate lock function has been
activated
- if switching on the blocking function was
accidental, turn this function off
- if switching on the blocking function was
intentional, first press the button
responsible for blocking on the remote
control (button "D"), and then the one that
is logged in.
3. Remote control button for the drive
not logged
3. Log the remote control into the drive
according to the instructions.
The door opens but does not close
1. The photocells support function is
enabled but the photocells are not
installed
1. Disable the photocell operation function
according to the instructions
2. The path of infrared rays has been
interrupted
2. Remove the obstacle

19
3. Faulty photocells
3. Send the photocells to the service
together with a description of the fault
and the purchase document
4. Insufficient drive force
4. Set the correct drive force in
accordance with the instructions and
standards.
When closing, the gate stops suddenly
and moves backwards
1. Increased resistance to door sliding
1. Unblock the drive and, by manually
moving the gate, check that the gate moves
easily and that it is well balanced with
springs.
2. Insufficient drive force
2. Set the correct drive force in accordance
with the instructions and standards.
When closing the door, the drive does
not react to the obstacle in the light of
the photocells
Incorrect photocells
If the gate is open and photocells are
covered, the gate will not close, and if the
gate does not respond to an obstacle, it
means that the photocells are not
compatible with the drive. Use photocells
suitable for garage doors
The drive moves the gate in steps of a
few centimeters
Defective engine RPM sensor circuit.
Send the drive to the service with a
description of the fault and the purchase
document
The remote control does not work
1. Battery discharged
1. Replace the battery
2. The remote control is not logged into
the drive
2. Log in the remote control according to
the instructions
3. Faulty remote control
3. Send the remote control to the service
together with a description of the fault and
the purchase document
The range of the remote control is too
small
1. Drive located in a steel or reinforced
concrete garage
1. Installation of an external antenna by a
specialist
2. Battery running low
2. Battery replacement
3. Faulty remote control
3. Send the remote control to the service
together with a description of the fault and
the purchase document
4. Defective radio module in the drive
4. Send the drive to the service together
with a description of the fault and the
purchase document
After a power failure and restarting, the
drive automatically moves the gate
1. Wrong type of wall switch to control
the door
1. To control the gate with a wall button, a
"bell" type button with normally open
contacts should be used. Replace the
button with the correct one.
2. Defective microcontroller
2. Send the drive to the service with a
description of the fault and the purchase
document
Other problem
Other reasons
Send the drive to the service with a
description of the fault and the purchase
document.
This manual suits for next models
2
Table of contents
Other HATO DC Drive manuals
Popular DC Drive manuals by other brands

Bosch
Bosch Rexroth IndraDrive FC Series operating instructions

G-U
G-U ELTRAL S 230 Installation, operation and maintenance instructions

KBB
KBB KS1000 Assembly and operating instructions

Danfoss
Danfoss VLT AutomationDrive FC 361 operating guide

SOMFY
SOMFY Roll Up Basic 28 instructions

Lenze
Lenze 8200 vector Mounting instructions