HATO ONE User manual

Original / Authorized Agent Stamp
Product Serial Number:
Purchase Date:
* To ensure your warranty validation, please place your agent's stamp in the box and fill in the purchase date. If the
agent stamp and purchase date cannot be supplied, the warranty period will based on the manufacturing date of
the product.
Download File
www.uprtek.com
uSpectrum PC Software
User Manual
HATO ONE
HATO Agricultural Lighting
T. +31 (0)46 4585050
https://www.hato.lighting
Handelsstraat 31 (Handelsstraat 29 visitor address)
6135 KK Sittard The Netherlands

Introduction
1
System Overview
3.1 Main Page
3.2 Measurement Modes Introduction
3.3 Measurement Introduction
3.4 Measurement Setting Introduction
3.5 Continuous Measurement Introduction
3.6 Customizing BASIC Mode List
3.7 Instruction of Spectrum Mode
3.8 FLICKER Mode Introduction
3.9 FREQUENCY Mode Introduction
3.10 ANALYSE Mode Introduction
3.11 CRI Mode Introduction
3.12 Switch Between CIE1931 & CIE1976
3.13 Compare Mode Introduction
3.16 Connecting with Mobile APP
3.17 Connecting with uSpectrum
3
Preparations before Use
2.3 System Reset
2
......................................................... 04
.
................................................. 18
......................................................... 19
.................. 21
.............................. 22
................. 23
......... 26
.......................... 27
........................ 28
............................. 29
...................... 30
........................ 31
.................................. 32
............. 34
........................ 35
3.14 BROWSER Mode Introduction ....................... 36
3.15 Transferring Data with PC Connection .......... 37
.......................... 38
Specification
4.1 Product Specification
4.2 Product Appearance and Dimension
4
Appendices
5.1 Product Warranty Terms
5.2 Measurement Indexes
5.3 Q&A
5
......................................................... 42
........................................ 43
............... 45
.......................... 39
........................................................... 48
.................................. 49
....................................... 53
.................................................................. 59
To get more information related to operation, firmware upgrade
and warranty terms; online application for correction and Repair
service, please contact [email protected]
- 1 - - 2 -
............................................. 05
............................... 06
............................ 07
...................... 07
................................ 08
...................................... 09
........................................ 13
.................................................... 14
1.1 Packing Contents
1.2 Appearance Introduction
1.3 Annual Product Calibration
1.4 Product Notes and Precautions
2.1 Preparing Before Use
2.2 Basic Measurement
Contents

1
- 3 - - 4 -
1.1 Packing Contents
1.2 Appearance Introduction
1.3 Annual Product Calibration
1.4 Product Notes and Precautions
Introduction

1
- 5 - - 6 -
If the system crashes, please press the power key for 3
seconds to turn off the system.
If the problem still can’t be fixed, please use a pin to
press the reset key to turn off the system.
1.2 Appearance Introduction
Sensor Cover
Capture Key
Battery Cover
SD Card Slot
Power Key
Reset Key
Mini USB
Power Jack
Battery
3.5” Touch Screen
Strap Hole
1.1 Packing Contents
SD card
HATO ONE
spectro- gallilux meter
( It is used to connect with PC software.)
User manual
Please check HATO ONE spectro- gallilux meter packing
before use, contact your agent if there are missing items.
WiFi Wing
wireless remote control card
( It is used to connect with APP.)
Strap Neck Strap
Battery
USB Cable
Power Adaptor
Protection Bag
Case Stand Bracket
User Manual

2
- 7 - - 8 -
As the product is a high-precision instrument, please use it cautiously.
To ensure the accuracy of measurements, annual calibration is recommended.
Please consult the customer service department for the calibration service:
HATO ONE spectro- gallilux meter is a high-precision instrument. Please
unpack with care. Any vibration or collision may cause instrument damage.
If the product doesn’t work normally or needs repair, please don’t
attempt any repairs. All repairs must be performed by the authorized
customer service agent.
Most LCD screens have a very small and inconsequential defective pixel
rate (usually less than 0.1%). This results in occasional pinpoints of white
or other colors but will not affect the accuracy of measurements.
1.
2.
Precautions / Warnings
Please read the following precautions to avoid fire, excessive heat, chemical
leakage and explosion :
◆ Do not disassemble or modify the battery.
◆ Do not expose the battery to heat (fire) or water/moisture.
◆When disposing used/old batteries, wrap with insulation tape to shield the battery from
electrical contact with metallic objects, which might ignite a fire or explosion.
◆If the unit is plugged into the power adapter and the battery seems to be overheating, or if
there is smoke or peculiar odors emanating from the unit, unplug immediately to avoid the
possibility of fire.
◆However, do not touch the cables if there is heat emanating from near the cables as melted
or deformed cables could expose wiring and result in burns or electric shock.
◆Do not use cloth or anything to wrap or cover the equipment while charging – this could
cause the unit to overheat, melting the casing or causing fire.
◆If the unit is accidently immersed in water, or if moisture has seeped inside, or metal objects
have dropped into the casing, immediately remove the battery to avoid fire or electric shock.
◆Do not operate or store the battery in high-temperature environments-it will cause battery
leakage and/or shorten the life of the battery .
◆Do not use paint thinner, benzene or other organic solvents to clean the equipment – this
may damage the exterior finish or touch screen, and may even ignite fire.
1.3 Annual Product Calibration
1.4 Product Notes and Precautions
Preparations before Use
2.1 Preparing Before Use
2.2 Basic Measurement
2.3 System Reset

- 9 - - 10 -
2.1 使用前準備
3
2
1
2.1 Preparing Before Use
Battery installation:
Step1. Hold HATO ONE, then press the battery cover.
Step2. Press the battery cover down to remove it.
Step3. Install the battery after removing battery cover.
※ Press the battery cover down then you can remove the
cover smoothly from HATO ONE.
1. Please charge the battery for 6 hours at first time usage.
2. To avoid any interruption while measuring, please check
battery status before use.
3. Please purchase a new battery if it gets low easily after being
fully charged, which means battery life comes to an end.
4. Usage time will depends on battery life, HATO ONE
battery can operate 5 hours after being fully charged.
2
1
Battery charging:
1. Plug power charging cable into power jack to start charging.
2. Power Off Status: Users can check power key, it will light in red while
charging and light off after being fully charged.
3. Power On Status: Users can check HATO ONE screen, it will appear
a lightning symbol to indicate charging, and lightning symbol will
disappear after being fully charged.
※ The power key will light
up in red, and light off
after fully charged.
when charging and disappear
after being fully charged.
※ Lightning symbol will appear
2.1 Preparing Before Use
3
2

- 11 - - 12 -
2.1 使用前準備 2.1 使用前準備
1
2
1
3
2
4
※ Press to remove the SD card
※ Insert the memory card
Installing the SD Card: Remove the SD Card:
according to the direction.
Strap installation:
Step1. Unscrew the strap.
Step2. Tie the strap to the strap hole of HATO ONE.
Step3. Tie the strap to the sensor cover.
Step4. Screw the strap.
Press the Power button for 1 second and then release it.
※ When the power is on, the Power
button will turn on the green indicator.
When the power is off, the green
indicator will be off.
Power on
Dark calibration
When the system is powered on and the power key is in green, the screen will
show the Dark Calibration.
“Do you want to
do dark calibration?”
Please select “Yes”.
After the sensor cover is put on,
please select “OK”.
When the screen shows “Dark calibration completed”,
please press “OK”to enter the main page.
It is recommended performing dark calibration every time
when it is powered on.
2.1 使用前準備
2.1 Preparing Before Use2.1 Preparing Before Use
HATO ONE.

- 13- - 14 -
Set date and time
After the dark calibration is completed, please set date and time before
measurement.
Go to the next page. Select “Option”. Select “Date”and
“Time”.
After the setting is
finished, please
press “Yes”.
After the setting is
finished, please
press “Yes”.
4 5
Please press the power key for 3 seconds to turn off the
system.
Measure
Select “Basic”to enter measurement page.
The measurement data
will be shown on the
screen after beep sound.
Press Capture key at
appropriate distance.
Point the sensor head at the target
light source.
Beep sound
while measuring
2.1 使用前準備 2.1 使用前準備
2.1 使用前準備
2.1 Preparing Before Use 2.2 Basic Measurement

- 15- - 16 -
2.3
Save measurement data
Press Save key on the lower right of the screen, and select “Yes”key.
The measurement data
are saved in the memory
card successfully.
Please record the file
name if necessary.
JPG file name:
IMGYYYY_MMDD_HHMMSS
.JPG
EXCEL file name:
ESPDYYYY_MMDD_HHMMSS
.xls
▲Can save the original data completely.
Fixed (Year) (Month) (Date) (Time)
Fixed (Year) (Month) (Date) (Time)
System Reset
Users can press the reset key to turn off the system
if system crashes.
Reset Key
to turn off the system.
※ Use a pen to press the reset key
2.2 Basic Measurement

3
- 17- - 18 -
System Overview
3.1 Main Page
3.2 Measurement Modes Introduction
3.3 Measurement Introduction
3.4 Measurement Setting Introduction
3.5 Continuous Measurement Introduction
3.6 Customizing BASIC Mode List
3.7 Instruction of Spectrum Mode
3.8 FLICKER Mode Introduction
3.9 FREQUENCY Mode Introduction
3.10 ANALYSE Modes Introduction
3.11 CRI Mode Introduction
3.12 Switch Between CIE1931 & CIE1976
3.13 Compare Mode Introduction
3.14 BROWSER Mode Introduction
3.16 Connecting with Mobile APP
3.17 Connecting with uSpectrum
3.15 Transferring Data with PC Connection

CIE
FREQUENCY
FLICKER
- 19 - - 20 -
3.1 3.1
Next
page
BASIC
ANALYSE
SPECTRUM
The interface of the product is touch screen operation. By touching the
screen with your figure, you may select the target menu or option.
The sub menus of each measurement mode are as shown below.
The interface of the product is touch screen operation. By touching the
screen with your figure, you may select the target menu or option.
The sub menus of each measurement mode are as shown below.
Back
page
COMPARE
CRI
Main Page Main Page
ID 0
LUX 0.0000 lx
Gallilux 0.0000
LUX Avg 00.00
Gallilux Avg 0.00
The analyse button allows you
to analyse the data of a defined
number of measurements.

8
5 6 7
1 2 3 4
- 21 - - 22 -
3.2 3.3
1. Measuring Mode - Basic
2. Measuring Function –Single operation
/continuous operation . For continuous measurement,
please refer to 3.5.
3. Exposure Mode -Automatic /Manual
4. Battery Power
5. Measurement Setting - please refer to 3.4.
6. Back to Main Page
7. Store the measured data- please refer to 3.3.
8. Show measured data – It shows different data based on the
measuring mode. You may make selections by yourself.
Save measured data:
Press save button
to save file
Confirm
Success Failed Failed
Please insert SD card
Please change SD card
Measurement IntroductionMeasurement Modes Introduction
Interface introduction:
Means button
M

Keyboard
Long time exposure Off
Normal
32K
1.0Hz
On
JPG
Sampling time
Dark calibration
Flicker resolution
Compare mode
Frequency domain (start) 1Hz
300Hz
Frequency domain (end)
0.000s
Time domain (start)
0.000s
Time domain (end)
- 23 - - 24 -
3.4 3.4Measurement Setting Introduction Measurement Setting Introduction
Previous
page
Back to
measurement page
Next
page
Measurement page
Please go to measurement page to do measurement settings.
+ / -:Adjust key
Yes / No:End of the setting
Capture Function Setting: Operation Sound Setting:
Integration Time Setting:Integration Mode Setting:Save Format Setting:
Long time exposure Setting:
Sampling time Setting: Flicker resolution Setting:
Integration time
Integration mode
Save format
Auto mode
Off
Operation sound
One time
Capture function
4K
Sampling time
2.0Hz
Flicker resolution
R
Long time exposure
On
Off
Yes No
Yes No Yes No

0 1 2 3 4
5 6 7 8 9
A B C D E F
G H I J K L
M N O P Q R
S T
Y
DEL OK
Z
U V W X
OK
1 2 3
0 BS
4 5 6
7 8 9
OK
1 2 3
0 BS
4 5 6
7 8 9
- 25 - - 26 -
3.4 Measurement Setting Introduction 3.5
Keyboard Instruction:
Keypad ON: The keypad interface will show up when
saving file, which allows you to rename the file.
Keypad OFF: It will skip the keypad interface when saving files,
and name the file automatically.
Confirm the input value and save it,
then return to the interface.
Key in the number or
English letter.
Select it to show the
input value on the
upper side.
Delete the input English
letter or number.
Keyboard Setting:
Dark calibration Setting:Frequency domain(start) : Frequency domain(end) :
Continuous Measurement Introduction
Step1. Select the continuous capture
Step2. Press the capture key
Step3. Processing the continuous measurement
Step4. Press capture key again to stop continuous measurement
Basic mode
(start measurement)
press capture key
Basic mode
(after measurement)
Press the capture key again to
see the measurement results.
HATO ONE will process
measurement with
interval of 3 seconds.
※ The capture symbol
is rotating when HATO
ONE is processing
continuous
measurement.
Select Continuous
1. Continuous measurement has no beep sound after press capture key.
2. Users cannot save the measurement data while processing continuous
measurement.
3. Adjust the integration time is only allowed in the manual mode.

5 6 7
1 2 3 4
Interface introduction:
Means button
- 27 - - 28 -
3.6 3.7 Instruction of Spectrum Mode
1. Measuring Mode - SPECTRUM
2. Measuring Function –Single operation
/continuous operation . For continuous measurement,
please refer to 3.5.
3. Exposure Mode -Automatic /Manual
4. Battery Power
5. Measurement Setting - please refer to 3.4.
6. Back to Main Page
7. Store the measured data- please refer to 3.3.
y
For more information about Measurement Index,
please refer to 5.2.
CRI CCT LUX
Customizing BASIC Mode List
Step1. Tap the box of measuring unit
Step2. Select an item from the list
Step3. The new data item will be displayed
Previous
page
Back to
BASIC mode
Next
page
The 4 items on the Basic list can be customized with different
units of measure (e.g. Gallilux fc, R9, LUX).
M

- 29 - - 30 -
3.8 3.9
MM
5 6 7
1 2 3 4
Interface introduction:
Means button
1. Measuring Mode - FLICKER
2. Measuring Function –Single operation
/continuous operation . For continuous measurement,
please refer to 3.5.
3. Exposure Mode -Automatic /Manual
4. Battery Power
5. Measurement Setting - please refer to 3.4.
6. Back to Main Page
7. Store the measured data- please refer to 3.3.
5 6 7
1 2 3 4
1. Measuring Mode - FREQUENCY
2. Measuring Function –Single operation
/continuous operation . For continuous measurement,
please refer to 3.5.
3. Exposure Mode -Automatic /Manual
4. Battery Power
5. Measurement Setting - please refer to 3.4.
6. Back to Main Page
7. Store the measured data- please refer to 3.3.
Interface introduction:
Means button
FLICKER Mode Introduction FREQUENCY Mode Introduction

- 31 - - 32 -
3.9 3.10
Touch the graph to switch the table between Frequency.
FREQUENCY Mode Introduction ANALYSE Mode Introduction
ID 0
LUX 0.0000 lx
Gallilux 0.0000
LUX Avg 00.00
Gallilux Avg 0.00
The analyse button allows you to measure and analyse data
of your whole barn trough multiple measurements.
Press ID to select the number of measurements.
Press ID to change to another measuring point.
Press Save icon to save the measurements,
When opening measured data on PC a report opens in
which the average, minimum and maximum values on:
LUX, Gallilux, Pct Flicker, Flicker index, Fc, CCT, CRI, CRI - R9
Additionally you will get Uniformity: Emin/Eav and Diversity:
Emin/Emax of lux, gallilux and Fc.
1

- 33 - - 34 -
3.11 3.12
M
5 6 7
1 2 3 4
1. Measuring Mode - FREQUENCY
2. Measuring Function –Single operation
/continuous operation . For continuous measurement,
please refer to 3.5.
3. Exposure Mode -Automatic /Manual
4. Battery Power
5. Measurement Setting - please refer to 3.4.
6. Back to Main Page
7. Store the measured data- please refer to 3.3.
Interface introduction:
Means button
CRI Mode Introduction
After entering the CRI Mode, user may see the
measured data such as CRI R1~R15 and Ra.
Switch Between CIE1931 & CIE1976
Touch the graph to switch the table between CIE1931
and CIE1976.

3.13
- 36 -- 35 -
與手機APP連線
3.14
Users can use the real-time measurement or select
the historical measurement data to show the measured
light source data with parallel display. We offer four
modes that allow you to compare the measurement of
the source data: BASIC, SPECTRUM, CIE 1931 and CIE 1976.
After the measurement is
completed, the measured
light source data are
compared by parallel
display.
Select the "light source"
mode you need.
CCT
CRI
Gallilux
LUX
13600
56.8
71.87
43.22 lx
00532
0.0
0.0193
0.0022 lx
Compare Mode Introduction BROWSER Mode Introduction
The Browser (on Home Screen) allows you to review historical
data that was previously saved to the SD card.
Step1. Press the “BROWSER”icon
Step2. A file browser will show the files on the SD card.
If you select an excel file, a review menu will be displayed.
Step3. Press any of the icons to review the data.
Step4. Displaying the data of excel file .
Previous
page
Back to
main manu
Return to the
previous folder
Next
page
Back to
file list
ESPD2018_0129_165546.xls
BASIC
CIE
SPECTRUM

3.15 與手機APP連線
- 38 -- 37 -
WiFi Wing wireless remote control card
Measure
Install APP
Insert WiFi Wing card to the system. At IOS or Android platform, download
HATO ONE APP and install it on your mobile. Then you can connect
it with system for the measurement of wireless control.
※For more operation, please refer to Wing user manual.
Please visit UPRtek official site, http://www.uprtek.com
Download and install the HATO ONE APP on your Mobile.
Select WiFi HATO ONE
HATO ONE
WiFi Wing
wireless remote control card
( It is used to connect with APP.)
HATO ONE
WiFi connection
Transferring Data with PC Connection
Storage the measurement data:
Inside the package has a USB cable, connect the mini USB to HATO ONE
and plug the USB to your PC then you can read the data saved in SD card.
After connected USB cable, HATO ONE will display as below.
Insert SD card
3.16 Connecting with Mobile APP
Table of contents
Other HATO Measuring Instrument manuals