HB Products A/S –
www.hbproducts.dk –
[email protected] – tel.: +4587476
00
Quick guide – HBLC-CO
– rev. 004
LED indication and calibration of sensor
echanical specifications:
Ambient temperature: - 0…+50°C
Liquid temperature: -50…+100°C
Max. pressure: 150 bar
Material, mechanical: AISI304/PTFE
Thread connection: see packaging.
Electrical specifications:
Supply: 4 VAC/DC
Current draw: Max 50 mA
Plug: DIN 06 7 – M1 /5 pins
Enclosure: IP65
Material, electronics: Nylon 6 (PA).
Please note! Supply Voltage may differ from the data given in the
manuals. Applicable will always be the sensor label.
LED indication:
Green LED indicates 4 V DC supply (blinks during operation)
Yellow LED – in connection with calibration
Red LED indicates ALARM at 100%
Installation guide:
It must be mounted vertically.
HBLC-CO can be mounted on an overflow pipe or a pipe segment
where flow and turbulence are minimized.
Calibration of sensor:
"R" for factory reset. Alarm is reset by pressing "R" for 5 seconds.
CAUTION! In case of welding work on the unit, please make sure that
proper earthing is carried out to avoid damaging the electronics.
NOTE! All terminals are protected against improper termination with a
supply voltage up to 40 V. If the supply voltage is greater than 40 V the
electronics will be damaged.
NOTE! Fault detection on the electronic function can be carried out
without releasing pressure from the system or disassembling the
mechanical part of the sensor.