HD Electric DOUBLE VISION DDVM-40 User manual

Operating & nstruction Manual
DUAL DISPLAY
VOLTMETER/PHASER
DOUBLE VISION
®
and ACCESSORIES
1475 Lakeside Drive • Waukegan, llinois 60085 U.S.A. • 847.473.4980
fax 847.473.4981 • website: www.HDElectricCompany.com

2

3
MPORTANT SAFETY NFORMAT ON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
GENERAL DESCR PT ON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
TECHN CAL SPEC F CAT ONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
OPERAT NG NSTRUCT ONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9
Battery Replacement nstructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Pre-Use nspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Voltage and Phasing Measurements – Line-to-Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Voltage Measurements – Line-to-Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Test Point Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Peak Hold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
PROBES AND ACCESSOR ES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-13
Proof Tester® Voltmeter Tester . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Cable Fault Tester . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-13
CARE AND MA NTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
CLEAN NG NSTRUCT ONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
REPA RS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
CAL BRAT ON AND MA NTENANCE LOG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
WARRANTY AND L AB L TY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Operating & nstruction Manual
VOLTMETER/PHASER
and ACCESSORIES

4
MPORTANT SAFETY NFORMAT ON
R ad and und rstand th s instructions prior to us . Th s op rating instructions
ar not a substitut for prop r training in th us of this quipm nt. High voltage
systems present serious hazards, including the risk of death or serious injury due to arcing,
thermal burns and electrocution. HD Electric Company products are intended solely for
use by professionals with knowledge, training and experience in the use of the equipment
and its accessories in and around high voltage systems.
All applicable federal, state, company and OSHA work practices
must be followed. f you are unfamiliar with the work practices
required, DO NOT PROCEED. Call HD Electric Company if you
have any questions regarding this equipment.
THESE IMPORTANT LABELS ARE AFFIXED TO
THE PRODUCT. READ AND UNDERSTAND EACH
OF THEM BEFORE PROCEEDING.
All meters require the use of accessory hotsticks, which may or may not be supplied with
the meter. The minimum hotstick length required for safe use depends upon the particular
operation; consult federal, state, company and OSHA specifications for the proper hotstick
length for the intended operation.
The users of this meter should always be equipped with personal protective equipment
including high voltage gloves, flame retardant clothing, eye and face protection. Some
applications may require additional protective equipment.
Accessory probes are available for all meters. Always use the proper probe(s) for your
application.
Failure to follow these and other warnings and safety precautions may result in severe
injury or death.
OPERATIONAL IMPAIRMENT
f the DDVM is used in a manner not described in this instruction manual,
the protection and effective operation of this equipment may be impaired.

5
GENERAL DESCR PT ON
The HD Electric Dual Display digital voltmeter/phaser is constructed with a high strength
molded housing with epoxy encapsulated high voltage resistors, a connecting cord and
a digital LED display.
The high voltage resistors limit the
current through the connecting
cord to a maximum of less than one
milliamp. Although the connecting
cord is insulated for voltage up to
20kV, it should always be kept free
and clear from you, ground and
any other conductors.
Hotstick Conn ction:
Shotgun or Univ rsal Splin

6
TECHN CAL SPEC F CAT ONS
MODEL NUMBER: DDVM-40
ENVIRONMENTAL CONDITIONS
• Conditions - ndoor and outdoor use
• Altitude - Up to 6,566 ft. (2000M)
• Operating Temperature -20°F to +120°F (-29°C to +49°C)
• Humidity - 95% to 49°C (non-condensing)
• Pollution Degree - PD4
• Measurement Category V - Classification Rating (CAT V) – Product is intended for
use with test and measuring circuits connected to the circuits/wiring outside of
a building installation, including transmission lines.
• Overvoltage Category V
• Enclosure Material - Supertough Nylon UL 94-HB
• Printed Circuit Boards - FR-4 UL94V-0
• Dimensions - Length 14 in. (36cm), Width 4.6 in. (12cm), Height 4.1 in. (10cm)
• Diameter of Fiberglass - 1”(2.54cm)
• Connecting Cord Length - 12’(3.6m) fully extended, 3.5’(1.7m) retracted
• Weight - (w/o probes): 2.25 lbs. (1.02kg) each unit
• Battery Life - 8 hours continuous use
• Battery - 9V alkaline 1604A, EC 6LR61 or 9V lithium, ANS -1604LC
• Digital Meter - Reads in kilovolts
• Voltage Range - 5V-40kV line to ground or line to line, AC 25-1000Hz or DC
• Auto-Ranging - No range selector switch
• Accuracy - Within 1% of reading +/- 3 counts
(line-to-ground & line-to-line measurements)
• Meter Resolution: 0.005 - 0.999 range with 1 Volt resolution
1.00 - 9.99 range with 10 Volt resolution
10.0 - 40.0 range with 100 Volt resolution

7
OPERAT NG NSTRUCT ONS
The DDVM-40 Dual Display Digital Voltmeter
measures DC and AC RMS voltage from 5V
to 40kV and from 25-1000Hz. Measurements
can be made line to ground or line to line.
The two LED displays are synchronized so
that the same voltage reading is shown on
both displays.
Press the ON button on both units to turn
them on. The initial zero kV indication will
be replaced shortly with the display of
hollow zeros as a battery saving measure.
A low battery indication in the lower
right corner of the screen indicates
that the battery will need to be replaced
soon. f the battery dies completely
in one unit, the display will shut
off and the remaining unit will
show the message REPLACE
PARTNER BATTERY. The battery
compartments are on the
bottom of each unit. HD Electric
recommends using 9V lithium
batteries but alkaline batteries
may also be used.
Both displays will turn off after
five minutes of a zero display.
BATTERY
REPLACEMENT
NSTRUCT ONS
To replace the battery, open
and remove the compartment
on the bottom of the meter
housing. Remove and dispose
of the old battery, replacing it with
a fresh, new 9-volt lithium or alkaline
battery. Note battery polarity on the battery
compartment. This compartment cannot be
reinserted if the battery polarity is reversed.

8
OPERAT NG NSTRUCT ONS
Pr -Us Insp ction
WARNING: Before using the instrument be sure to test and inspect the equipment
to ensure that it is functioning properly and is in safe, working condition. Failure to do
so may cause serious injury or death and may result in erroneous test measurements.
Before making any high voltage measurements,
test and inspect the voltmeter/phaser as follows:
1) Make certain the instrument is clean and dry.
2) nspect the cord for cracked insulation.
3) Be sure that you are using hotsticks of the appropriate length, and examine each
hotstick to ensure that it is clean, dry and waxed to a clear shiny surface.
4) Attach the appropriate probes for overhead or underground applications
(see page 10) and ensure that the probes are properly installed and tightened
(do not overtighten).
5) Confirm that the meter is configured for the correct application (normal reading,
Peak Hold, Test Point or CFT).
6) Test the voltmeter/phaser with an appropriate tester, such as the HD Electric PT-5000B
Proof Tester® Voltmeter Tester (see page 10).
Voltag and Phasing M asur m nts – Lin -to-Lin
We recommend that two person crews perform all line-to-line voltage measurements
and phasing operations. Since the operation is occurring near two energized conductors,
the use of two person crews allows each person to operate one meter stick and maintain
high safety standards.
n order to make line-to-line measurements, each probe must contact an energized
line. Be sure that only those probes intended for the particular application are used
(see page 10). Always keep the connecting cord free and clear of energized phases
and ground. For phasing applications, the probes will be placed on opposite sides
of an open point, typically a switch. The phasing operation will indicate if two sides
of a line are in-phase before closing a switch.
To check all phases proceed as follows:
1) Measure voltage on each phase from line-to-ground to verify all phases
are live and at the same voltage.
2) Place one of the probes on a conductor on one side of the switch.
3) Place the other probe on one of the three phases on the other side of the switch.
4) f the conductors are out-of-phase, the meter will read line-to-line voltage.
f they are in-phase, the meter will read near zero but may read up to 15%
of the line-to-line voltage.
5) Continue this procedure with all three phases on both sides of the switch.
f an intermediate reading is found, the phasing cannot be determined by this method
and the switch should not be closed until other means are used for phasing.

9
OPERAT NG NSTRUCT ONS continued
Voltag M asur m nts – Lin -to-Ground
First connect one of the probes to either a ground or system neutral making sure
the resistor stick is making contact at all times during measurement. The other
probe should be connected to the energized source to be measured.
Maintain contact only long enough to read the meter. Always remove the probe
from the energized source first before removing the ground connection.
T st Point M asur m nts
To activate Test Point mode simply push the ON
button again. Test Point mode is indicated by TP
in the display. To turn Test Point mode off, simply
push the ON button once and verify the TP turns
off. When using a DDVM to phase between
test points, the important measurement is whether high voltage is present or not.
The proper procedure for phasing between elbow test points is as follows:
1) Both elbows must be energized. Follow the proper safety practices for removing the
test point protective caps and exposing the live test points. Treat all exposed electrodes
as energized high voltage. Measure from both elbow test points to ground. These
measurements should show that both elbows are energized and, if both elbows are of
the same type and manufacture, should measure the same approximate line voltage.
2) Measure from one elbow test point to the other. This reading will show either a
high voltage reading indicating the elbows are out-of-phase or a zero or low voltage
reading indicating the elbows are connected to the same phase. The out-of-phase
measurement will likely not show the higher voltage expected from a phase-to-phase
measurement but will be closer to the line-to-ground voltage. The in-phase voltage
measurement can be between zero and 15% of the nominal line-to-ground voltage. f
both elbows are of different type and manufacture, then the reading may be higher.
P ak Hold
Press the ON button to activate this
feature and once again to clear the
reading. The H in the display confirms
Peak Hold. The display will hold the
highest reading while Peak Hold is
activated. NOTE: The meter will not shut
off while a peak reading is displayed.

10
WARNING: ALWAYS use probes appropriate to your application.
NEVER use overhead probes in underground applications.
Failure to use the correct probe can result in arcing or electrical
contact and may cause serious injury or death. f you are not
trained in the particular operation or are not sure about the
appropriate probe for your application DO NOT PROCEED.
Ov rh ad Prob s
A. OLPS-5 brass hook probe
B. OLPS-6 brass pigtail probe
C. Hotstick
A range of hotsticks are available in lengths
starting at 4’. Contact HD Electric for more details.
D. Insulat d Und rground Prob
GCP-1 for general underground use
on grounded terminals, exposed high
voltage terminals or elbow test points.
Und rground D ad Front Bushing Prob s
E. ASP-15/25 for use in 15kV and
25kV loadbreak bushings
F. ASP-35U for use in 35kV loadbreak bushings
G.Und rground Elbow Prob
EA-15/25 for insertion in loadbreak elbows.
NOTE: The elbow must be firmly supported when using this probe.
Proof-T st r® Voltm t r T st r
The PT-5000B Proof Tester Voltmeter Tester will produce 5kVDC
at the test leads to confirm proper operation of voltmeters and
phasers. This tester should be used only with voltmeters/phasers
that measure DC voltage. t will not confirm operation of
voltmeters/phasers that measure AC voltage only. The PT-5000B
operates from one 9V lithium or alkaline battery and produces
approximately 5kVDC at the connecting leads. To use:
1) Connect both tester leads to the voltmeter/phaser probes.
2) Press and hold both TEST buttons.
3) Confirm a good battery by checking the red light on the Tester. f the red
light does not come on, replace the battery with a 9V lithium or alkaline only.
4) Verify the voltmeter/phaser reads approximately 5kV.
5) Release the TEST buttons and disconnect the Tester from the voltmeter/phaser.
WARNING: Do not use the voltmeter/phaser if proper operation is not confirmed.
WARNING: Do not use this tester except as directed. Do not use to test equipment other
than voltmeters/phasers. Do not apply to energized circuits or equipment. Refer all
servicing to the factory. Failure to follow these instructions may lead to electric shock,
severe injury or death.
PROBES AND ACCESSOR ES
AB
C
DE F G

11
PROBES AND ACCESSOR ES continued
Cabl Fault T st r
The CFT-35 is for use only
with two stick voltmeters
for testing leakage
current in underground
primary voltage cables.
The CFT-35 can be used
on underground cables with grounded neutrals with a maximum line-to-ground voltage
of 21.1kV or maximum line-to-line voltage of 36.6kV. Operation at higher voltages may
damage the CFT-35 and provide erroneous test results.
The CFT-35 is used with a voltmeter/phaser for testing installed or repaired underground
cable prior to energizing it. Only cable with extruded dielectric such as rubber or
polyethylene can be tested with the CFT-35. Using the CFT-35 on paper insulated
cable may provide erroneous test results caused by higher leakage currents
typical for this type of cable.
The CFT-35 contains a high voltage rectifier and is connected to test underground
primary cable as shown in this circuit:
n practice, the CFT-35 rectifies the high voltage from the source, usually a transformer
primary, and charges up the cable, shown as a capacitor above. When a connection is first
made, the DC from the CFT-35 will charge up the cable capacitance through the resistors
in the meter sticks. f the cable is good, current will stop flowing when the cable is charged
up. f the cable is not good, the cable will not charge and current will continue to flow, as
indicated by a higher meter indication.
The following equipment is required for testing cable with a CFT-35:
1) HD Electric two-stick voltmeter/phaser model DDVM-40.
2) The CFT-35 Cable Fault Tester.
3) For deadfront applications, ASP bushing probe(s) or, for live front applications, GCP-1
probe(s). An EA-15/25 elbow probe may also be used for deadfront applications.
4) For deadfront applications, a feed-through bushing may also be used.
CFT-35

12
PROBES AND ACCESSOR ES continued
Shown below is a typical application of the CFT-35 and associated equipment for testing
underground cable from a pad-mount dead front transformer:
Before using the CFT-35, read and understand all of the instructions and precautions
for live testing with voltmeters/phasers (pages 7-9). n addition, be sure to consult your
company’s work practices and any information provided by the manufacturers of the
apparatus that you are testing.

13
PROBES AND ACCESSOR ES continued
Cabl Fault T st r
and Bushing Prob
1) Test the cable with the voltmeter/phaser to insure
that it is not energized and that it is discharged.
2) nsure that the cable to be tested is completely
isolated; that both ends have no other connection
to voltage or to a transformer winding and are
properly terminated.
3) Turn on the Dual Display voltmeter/phaser and
press the ON button again to select CFT mode.
4) Assemble the CFT-35 with appropriate probe on
the unit displaying CFT-35.
5) Connect the voltmeter/phaser unit displaying TO
CABLE UNDER TEST to the cable to be tested with
the appropriate probe.
6) Connect the voltmeter/phaser displaying CFT-35
to the voltage source.
7) Read the bar graph display. The reading will be
initially high. For a short cable, the reading should
return quickly to near zero. For a longer cable, it
may take a few seconds for the reading to return
to near zero. For a good cable, only one or two bars
will remain high. Note that the highest bar will
remain on as a reminder of the maximum reading.
8) f all or most of the bars stay on, the cable is leaking
or shorted and CABLE FAULT will be displayed.
Discontinue the test.
9) Discharge the cable by removing the voltmeter/
phaser from the line, removing the CFT-35 from the
voltmeter/phaser and connecting the voltmeter/
phaser from the cable just tested to ground.
Testing using the CFT-35 should be performed as follows:

14
CARE AND MA NTENANCE
Periodic regular maintenance is required to keep the voltmeter in proper operating condition.
Digital models will require periodic battery replacement. Keep the voltmeter clean and dry
and always store it in its case. The sticks should be kept clean and free of dirt, contamina-
tion and marking. Examine the cord for cracking or other damage prior to each use. Al-
though we do not specify a calibration cycle, we recommend you test, measure and
calibrate your instrument annually. The Calibration and Maintenance Log provided on
page 15 can be used to record these events. Contact HD Electric Company for details.
CLEAN NG NSTRUCT ONS
To clean the DDVM wipe with a damp cloth with water.
Do not use harsh chemicals or solvents.
REPA RS
All repairs and calibration are performed at HD Electric Company. f any damage is
found please contact HD Electric Company at 847-473-4980 to arrange for service.
MANUFACTUR NG LOCAT ON
HD Electric Company • Waukegan, L. 60085, USA

15
CALIBRATION AND MAINTENANCE LOG
DATE CAL BRATED BY

LIMITED WARRANTY AND LIMITATION OF LIABILITY
This warranty applies to all products sold by HD Electric Company (the "Products"); provided, however, that the term Products does not include any
third party products purchased through HD Electric Company, for which no warranties are made (the "Third Party Products"). Third Party Products
may be subject to a separate manufacturer's warranty; [should you have any question regarding whether a separate warranty applies, please contact
HD Electric Company].
NOT CE: READ TH S L M TAT ON OF WARRANTY AND L AB L TY BEFORE BUY NG OR US NG THE PRODUCTS CONTA NED HERE N.
t is impossible to eliminate all risks associated with the use of the Products. Risks of serious injury or death, including risks associated with electrocution,
arcing and thermal burns, are inherent in work in and around energized electrical systems. Such risks arise from the wide variety of electrical systems
and equipment to which Products may be applied, the manner of use or application, weather and environmental conditions or other unknown factors,
all of which are beyond the control of HD Electric Company.
HD Electric Company does not agree to be an insurer of these risks, and shall have no liability for any claims arising from such risks.
WHEN YOU BUY OR USE THESE PRODUCTS, YOU AGREE TO ACCEPT THESE R SKS.
HD Electric Company warrants to the original purchaser that the Products (excluding any third party products purchased through HD Electric Company,
for which no warranties are made) will be free from defects in material and workmanship, under normal use and regular service, and preventative
maintenance for a period of one (1) year (ten (10) years for HDE Capacitor Controls) from the date of shipment (the “Warranty Period”). Should any failure
to conform with this warranty be found during the Warranty Period, you must notify HD Electric Company of your claim within thirty (30) days of discovery,
and within the Warranty Period. Your failure to give notice of claims of breach of warranty within the Warranty Period shall be deemed an absolute and
unconditional waiver of claims for such defects. HD Electric Company will have no responsibility to honor claims received after the date the applicable
Warranty Period expires.
Upon notice of your claim, HD Electric Company will provide a return authorization number, and further instructions on how to return the product for
service. You must follow HD Electric Company’s instruction. You are responsible for all Product removal, handling, re-installation, and shipping (both
to and from HD Electric Company). Products returned for repair, as well as repaired or replacement Products shall be sent postage / freight prepaid. After
receipt of a product which HD Electric Company determines is defective, HD Electric will, at its option, either (1) repair (or authorize the repair of) the
Product or (2) replace the Product, subject to the following: The Products are made using parts sourced from a variety of manufacturers. Due to the rapidly
changing technology environment, parts may become obsolete / unavailable over time (end of life). n the event that a Product cannot be repaired or
replaced due to unavailability of parts, HD Electric Company will use commercially reasonable efforts to obtain substitute parts or conduct work around
design, but cannot guarantee its ability to do so.
tems not found defective will be returned at your expense, or failing receipt of instruction from you on return of such items within five (5) business days
of our notice to you that the product is not defective, HD Electric may dispose of the product at its discretion and with no liability to you. HD Electric
Company’s determination of defects is final. Products repaired or replaced during the Warranty Period shall be covered by the foregoing warranties for
the remainder of the original Warranty Period or ninety (90) days from the date of delivery of the repaired or replaced Products, whichever is longer.
LIMITATIONS:
This warranty is void in the event of misuse, alteration, faulty installation, or misapplication of the product.
This warranty does not cover failure of product or components due to any ACT OF NATURE; lightning, floods, hurricanes, tornadoes or any other such
catastrophic events.
HD Electric Company does not warrant any third party products or associated hardware or their performance or suitability for use and application. Such
items are provided “as-is”.
All repairs must be authorized by HD Electric Company. Unauthorized repairs will not be reimbursed under any circumstances.
HD Electric Company is not required to make replacement or loaner equipment available while Products are being repaired or replaced, or to compensate
you for any in/out labor charges or expenses associated with removal, handling or re-installation of the Products.
TO THE MAX MUM EXTENT PERM TTED BY LAW, TH S WARRANTY AND THE REMED ES SET FORTH ABOVE ARE EXCLUS VE AND N L EU OF ALL OTHER
WARRANT ES, REMED ES AND COND T ONS, WHETHER ORAL OR WR TTEN, EXPRESS OR MPL ED. HD ELECTR C EXPRESSLY D SCLA MS ALL OTHER
WARRANT ES OF ANY K ND, EXPRESS OR MPL ED, NCLUD NG W THOUT L M TAT ON MPL ED WARRANT ES OF F TNESS FOR A PART CULAR PURPOSE,
MERCHANTAB L TY AND NON- NFR NGEMENT.
N NO EVENT SHALL HD ELECTR C COMPANY BE L ABLE FOR ANY ND RECT, NC DENTAL, CONSEQUENT AL OR SPEC AL DAMAGES RESULT NG FROM THE
USE OR HANDL NG OF THESE PRODUCTS. TH S SHALL NCLUDE BUT, NOT L M TED TO, LOST PROF TS OR REVENUE, LOSS OF USE OF THE PRODUCTS,
COST OF SUBST TUTE PRODUCTS, FAC L T ES OR SERV CES, OR DOWNT ME.
N NO EVENT SHALL HD ELECTR C COMPANY HAVE ANY L AB L TY FOR ANY TH RD PARTY PRODUCTS OR ASSOC ATED HARDWARE, OR
CUSTOMER-OWNED SYSTEMS, EQU PMENT OR SOFTWARE.
HD Electric Company must have prompt notice of any claim so that an immediate product inspection and investigation can be made. Buyer and all
users shall promptly notify HD Electric Company of any claims, whether based on contract, negligence, strict liability, or other tort or otherwise be barred
from any remedy.
HD Electric Company is committed to ongoing review and improvement of its product lines,
and thus reserves the right to modify product design and specifications without notice.
HD Electric Company® products are available through HDE® sales representatives worldwide.
Printed in U.S.A. © HD Electric Company 2017 • Bulletin No. DDVM M-100f
Table of contents
Other HD Electric Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Eastron
Eastron SDM220-MBUS user manual

Endress+Hauser
Endress+Hauser Teqwave T operating instructions

Xylem
Xylem Sensus Residia-M Installation and operating instructions

HR Matic
HR Matic COMPAT CHECK instruction manual

KTS-Electronic
KTS-Electronic GPA 3000 manual

Bosch
Bosch RTM 430 Description of the Unit

Titan
Titan Metraflow 240-020 instruction manual

Camille Bauer
Camille Bauer SINEAX DME 400 Series operating instructions

ADA INSTRUMENTS
ADA INSTRUMENTS COSMO 70eter operating manual

AQUASCAN INTERNATIONAL
AQUASCAN INTERNATIONAL DX-300 operating instructions

DynAmp
DynAmp LKAT Plus Installation, operation and service manual

METREL
METREL EurotestCOMBO MI 3125 instruction manual