HDE CDM-50 User manual

CDM-50
& CDM-75
C A B L E D I S TA N C E M E T E R S
Operating & nstruction Manual
1475 Lakeside Drive • Waukegan, llinois 60085 U.S.A. • 847.473.4980
fax 847.473.4981 • website: www.HDElectricCompany.com

2

3
NTRODUCT ON
The Cable Distance Meter is a unique, handheld instrument, primarily used for the
measurement of the height of overhead cables. The Cable Distance Meters measure
up to 6 cables.
The CDM-50 model measures to a height of up to 50 feet (15m). The CDM-75 model
has an increased range of up to 75 feet (23m). The unit operates by transmitting an
ultra-sonic signal towards the wires, and measuring the time it takes to pick up the
echo from that signal. t automatically compensates for the fact that the speed of
sound varies with temperature by monitoring the ambient temperature using the
internal temperature sensor. The display continuously shows the ambient temperature
reading. Because the temperature sensor reacts relatively slowly to large temperature
changes, it is necessary to wait up to 10 minutes for the temperature reading to stabilize
after taking the meter suddenly from a warm to a cold environment before taking a
measurement, e.g. taking the unit from inside a warm vehicle to outside. solate the
CDM from any hot surface such as sun warmed pavement using a notebook or several
sheets of paper.
Cone
Transducer
Temp Indicator
Measurement Units
Hei ht Measurement
ON Switch
CAL Mode
Stored Measurements
Temperature Sensor
Read Stored Measurements
Make Measurement
Clear memory
Battery Compartment
(Side of Unit)

4
TO MAKE A MEASUREMENT
1. Select the required measurement units by setting the switch at the back of the unit to
display in feet and inches ( ) or meters (M).
2. Set the Calibrate switch to the CABLE position.
3. Press the ON key to power on the unit.
4. Position unit directly under the cable(s) to be measured.
5. Press and hold the
MEASURE key to take a
measurement. The distance
to the first cable is shown
in the Height Measurement
location in the display.
f there is more than one
cable present, the
difference in height
between each cable is
stored in memory.
6. Press the READ CABLES 1-6
key to display each of the
cable height differences
stored in memory (Stored
Measurements). The unit
will automatically turn off
3 minutes after the last key
has been pressed.
All measurements are
displayed in the format
feet.inches followed by
fractions of an inch.

5
Hints & Guidelines
Position the unit on the ground, directly underneath the cable to
be measured. Align the unit in the direction of the cable, with the
cone pointing towards the cable, as shown.
When taking cable measurements, ensure that there are no
walls or buildings within a distance of 7 feet (2m) on either side
of the meter, as reflections from these will distort the readings.
Also ensure there are no trees or other overhanging objects in
the vicinity.
When measuring more than one cable, ensure that none of the
cables are outside the sonic beam, as shown in the Performance
section of this manual. f the cables are not vertically above one
another, this could be the case. n this instance, it will be necessary
to take a number of separate readings
from different positions.
Water and moisture can cause the
Cable Distance Meter to malfunction.
Therefore, the meter should not be
used in rain or snow. f water does
get into the cone, leave it upside
down in a dry, warm area.
f the display shows – – – . – – – , this
indicates a “poor target” and normally
happens when the cables are moving
due to wind, etc. Wait until the wind
dies down to get an accurate reading.
CAL BRATE MODE
The Calibrate mode switch allows the user to periodically check the unit to ensure that
it is still operating within specification. For cable distance measurement, this switch
should be in the CABLE position. When the switch is put to the WALL position, horizontal
measurements to large objects, e.g. walls, can be taken.
When the unit is first used, a horizontal reading to an object, e.g. wall, from a fixed position
should be taken. The reading should be entered, together with the date, into the table below.
Whenever the unit is to be checked for accuracy, a reading should be taken from the same
point, noting the result and date in the table. f the reading is outside of specification, the unit
should be returned to HD Electric for calibration.
Date
Reading
Front
View
Side View

6
TROUBLESHOOT NG
The following is a list of actions to be taken if the unit is not working properly:
SCREEN IS BLANK
Check to make sure the battery is inserted correctly. Open battery door on the bottom rear
of the unit. The battery is inserted with the terminals on the inside. The + and - symbols on
the battery should match the corresponding + and - symbols on the inside of the battery
compartment.
UNIT DOES NOT MEASURE ALL WIRES
Ensure that horizontal distances between wires are within the sonic beam, as shown in the
Performance section of this manual.
INCORRECT READINGS
Ensure the Calibrate mode switch is in correct position, i.e. CABLE for cable height meas-
urement, and WALL for horizontal distance to object measurement. Ensure no walls or
similar obstructions are within 7 feet (2m) of either side of the unit, as reflections from
these can interfere with correct operation.
SPEC F CAT ONS
Model CDM-50 Model CDM-75
1 inch (25mm) Cable Diameter 10’ - 50’ (3m – 15m) 10’ - 75’ (3m – 23m)
0.5 inch (12mm) Cable Diameter 10’ - 50’ (3m – 15m) 10’ - 50’ (3m – 15m)
0.25 inch (5.5mm) Cable Diameter 10’ - 40’ (3m – 12m) N/A
0.125 inch (2.5mm) Cable Diameter 10’ - 33’ (3m – 10m) N/A
No. of wires measured 66
Accuracy 0.5% ± 2 digits
Resolution (less than 33’) 0.25” (5mm)
Resolution (more than 33’) 0.5” (10mm)
Minimum gap between wires 6” (150mm)
Operating Temp. Range 14° F to 104° F (-10° C to 40° C)
Battery Life 50,000 measurements (Long Life Alkaline type)
Measurement units mperial (feet/inches) or metric (meters)
Auto power off delay 3 minutes
Dimensions 8.5” x 4” x 3” (205mm x 100mm x 70mm)
Weight 1.1 lb. (0.5kg)

7
1OO ft
Minimum
Cable
Diameter
50 ft
75ft
23m
4.5ft / 1.4m
3ft / 0.9m3ft / 0.9m
Beam Width
4.5ft / 1.4m
50ft
15m
75 ft
O ft
0.5 in
12mm
1 in
25mm
1OO ft
Minimum
Cable
Diameter
50 ft
50ft
15m
3ft
0.9m
Beam Width
3ft
0.9m
40ft
12m
33ft
10m
33ft
10m
33 ft
O ft
0.125 in
2.5mm
0.25 in
5.5mm
0.5 in
12mm
1 in
25mm
PERFORMANCE
CDM-50 Measurement versus Cable Diameter
CDM-75 Measurement versus Cable Diameter

LIMITED WARRANTY AND LIMITATION OF LIABILITY
This warranty applies to all products sold by HD Electric Company (the "Products"); provided, however, that the term Products does not include any
third party products purchased through HD Electric Company, for which no warranties are made (the "Third Party Products"). Third Party Products
may be subject to a separate manufacturer's warranty; [should you have any question regarding whether a separate warranty applies, please contact
HD Electric Company].
NOT CE: READ TH S L M TAT ON OF WARRANTY AND L AB L TY BEFORE BUY NG OR US NG THE PRODUCTS CONTA NED HERE N.
t is impossible to eliminate all risks associated with the use of the Products. Risks of serious injury or death, including risks associated with electrocution,
arcing and thermal burns, are inherent in work in and around energized electrical systems. Such risks arise from the wide variety of electrical systems
and equipment to which Products may be applied, the manner of use or application, weather and environmental conditions or other unknown factors,
all of which are beyond the control of HD Electric Company.
HD Electric Company does not agree to be an insurer of these risks, and shall have no liability for any claims arising from such risks.
WHEN YOU BUY OR USE THESE PRODUCTS, YOU AGREE TO ACCEPT THESE R SKS.
HD Electric Company warrants to the original purchaser that the Products (excluding any third party products purchased through HD Electric Company,
for which no warranties are made) will be free from defects in material and workmanship, under normal use and regular service, and preventative
maintenance for a period of one (1) year (ten (10) years for HDE Capacitor Controls) from the date of shipment (the “Warranty Period”). Should any failure
to conform with this warranty be found during the Warranty Period, you must notify HD Electric Company of your claim within thirty (30) days of discovery,
and within the Warranty Period. Your failure to give notice of claims of breach of warranty within the Warranty Period shall be deemed an absolute and
unconditional waiver of claims for such defects. HD Electric Company will have no responsibility to honor claims received after the date the applicable
Warranty Period expires.
Upon notice of your claim, HD Electric Company will provide a return authorization number, and further instructions on how to return the product for
service. You must follow HD Electric Company’s instruction. You are responsible for all Product removal, handling, re-installation, and shipping (both
to and from HD Electric Company). Products returned for repair, as well as repaired or replacement Products shall be sent postage / freight prepaid. After
receipt of a product which HD Electric Company determines is defective, HD Electric will, at its option, either (1) repair (or authorize the repair of) the
Product or (2) replace the Product, subject to the following: The Products are made using parts sourced from a variety of manufacturers. Due to the rapidly
changing technology environment, parts may become obsolete / unavailable over time (end of life). n the event that a Product cannot be repaired or
replaced due to unavailability of parts, HD Electric Company will use commercially reasonable efforts to obtain substitute parts or conduct work around
design, but cannot guarantee its ability to do so.
tems not found defective will be returned at your expense, or failing receipt of instruction from you on return of such items within five (5) business days
of our notice to you that the product is not defective, HD Electric may dispose of the product at its discretion and with no liability to you. HD Electric
Company’s determination of defects is final. Products repaired or replaced during the Warranty Period shall be covered by the foregoing warranties for
the remainder of the original Warranty Period or ninety (90) days from the date of delivery of the repaired or replaced Products, whichever is longer.
LIMITATIONS:
This warranty is void in the event of misuse, alteration, faulty installation, or misapplication of the product.
This warranty does not cover failure of product or components due to any ACT OF NATURE; lightning, floods, hurricanes, tornadoes or any other such
catastrophic events.
HD Electric Company does not warrant any third party products or associated hardware or their performance or suitability for use and application. Such
items are provided “as-is”.
All repairs must be authorized by HD Electric Company. Unauthorized repairs will not be reimbursed under any circumstances.
HD Electric Company is not required to make replacement or loaner equipment available while Products are being repaired or replaced, or to compensate
you for any in/out labor charges or expenses associated with removal, handling or re-installation of the Products.
TO THE MAX MUM EXTENT PERM TTED BY LAW, TH S WARRANTY AND THE REMED ES SET FORTH ABOVE ARE EXCLUS VE AND N L EU OF ALL OTHER
WARRANT ES, REMED ES AND COND T ONS, WHETHER ORAL OR WR TTEN, EXPRESS OR MPL ED. HD ELECTR C EXPRESSLY D SCLA MS ALL OTHER
WARRANT ES OF ANY K ND, EXPRESS OR MPL ED, NCLUD NG W THOUT L M TAT ON MPL ED WARRANT ES OF F TNESS FOR A PART CULAR PURPOSE,
MERCHANTAB L TY AND NON- NFR NGEMENT.
N NO EVENT SHALL HD ELECTR C COMPANY BE L ABLE FOR ANY ND RECT, NC DENTAL, CONSEQUENT AL OR SPEC AL DAMAGES RESULT NG FROM THE
USE OR HANDL NG OF THESE PRODUCTS. TH S SHALL NCLUDE BUT, NOT L M TED TO, LOST PROF TS OR REVENUE, LOSS OF USE OF THE PRODUCTS,
COST OF SUBST TUTE PRODUCTS, FAC L T ES OR SERV CES, OR DOWNT ME.
N NO EVENT SHALL HD ELECTR C COMPANY HAVE ANY L AB L TY FOR ANY TH RD PARTY PRODUCTS OR ASSOC ATED HARDWARE, OR
CUSTOMER-OWNED SYSTEMS, EQU PMENT OR SOFTWARE.
HD Electric Company must have prompt notice of any claim so that an immediate product inspection and investigation can be made. Buyer and all
users shall promptly notify HD Electric Company of any claims, whether based on contract, negligence, strict liability, or other tort or otherwise be barred
from any remedy.
HD Electric Company is committed to ongoing review and improvement of its product lines,
and thus reserves the right to modify product design and specifications without notice.
HD Electric Company® products are available through HDE® sales representatives worldwide.
Printed in U.S.A. © HD Electric Company 2016 • Bulletin No. CDM M-200c
This manual suits for next models
1
Table of contents
Other HDE Measuring Instrument manuals