Hearth & Home Technologies Inc. • ST1175 Termination Cap • 34502 Rev E • 01/05 1

Models:
ST1175
Termination Cap
Installation
Instructions
These chimney termination caps have been tested for use with specific Hearth & Home Technologies Inc. (HHT) fireplaces
and is a fireplace part. Refer to the fireplace installation isntructions for the correct accessories to be used. Check with
your local building code agency before you begin installation to ensure compliance with local codes, including the need
for permits and follow-up inspections. If you encounter any problems regarding code approvals, or if you need clarification
of any of the instructions contained here, contact the Heatilator Technical Services Dept., Hearth & Home Technologies
Inc., 1-800-927-6841 or 1-888-427-3973.
Note: An arrow () found in the text signifies change in
content.
1a
3
2
1b
FEET
CHASE TOP
MAX. 4-3/4 in.
(121 mm)
Item Description Qty
1a Termination Cap - Top 1
1b Termination Cap - Base 1
2 Slip Section 1
3 Fastener Package 1
Note: The ST1175 is designed for use
with the SL1100 Series pipe.
Sharp Edges
• Wear protective gloves and safety
glasses during installation.
CAUTION
1. Assemble the SL1100 Series chimney Sections to within 4-3/4 in.
(121 mm) below the top of the chase.
2. Remove the top by taking out the four screws that secure it to the
corner posts. If the top is not screwed on, proceed to Step 3.
3. Center the partially disassembled base of the termination cap
over the chimney (inside the chase). Drop the double walled slip
section through the flanged opening in the base of the termina-
tion cap so it telescopes both the inner and the outer chimney
sections.
4. Adjust the termination cap so the slip section does not bind the
chimney section. Rotate the cap so it is square with the chase
and mark the position using the holes provided in the feet as a
guide.
5. Drill through the chase top using a 1/8 in. (3 mm) diameter drill
bit at the marked locations. Securely attach the cap to the chase
using the screws provided in the fastener package.
6. Assemble the top of the termination cap and replace and tighten
all the screws.
7. Caulk all screws or nails on the chase top. Periodic re-caulking
may be needed to prevent leaks from developing.
Fire Risk
You must use the slip section provided with
this chimney top.
• Single wall or other variations from the
slip section MUST NOT be used.
Substitute parts may increase temperatures
to adjacent combustible materials.
WARNING
Fire Risk
• Intended for use with a metal chase
top.
Use of combustible materials will cause a
fire hazard.
WARNING

This manual suits for next models

1

Other Hearth and Home Technologies Ventilation Hood manuals

Hearth and Home Technologies TR342 User manual

Hearth and Home Technologies

Hearth and Home Technologies TR342 User manual

Hearth and Home Technologies Heat Recovery Ventilator HRV200PLUS User manual

Hearth and Home Technologies

Hearth and Home Technologies Heat Recovery Ventilator HRV200PLUS User manual

Hearth and Home Technologies Square Termination Cap TS345 User manual

Hearth and Home Technologies

Hearth and Home Technologies Square Termination Cap TS345 User manual

Hearth and Home Technologies Termination Cap ST375 User manual

Hearth and Home Technologies

Hearth and Home Technologies Termination Cap ST375 User manual

Popular Ventilation Hood manuals by other brands

Whirlpool W10502583F Installation Instructions and Use & Care Guide

Whirlpool

Whirlpool W10502583F Installation Instructions and Use & Care Guide

Prestige Pro Line Use & care manual

Prestige

Prestige Pro Line Use & care manual

Klarstein 90DS3 manual

Klarstein

Klarstein 90DS3 manual

GLOBALO Retio 60 Operating and installation instructions

GLOBALO

GLOBALO Retio 60 Operating and installation instructions

NEFF D64XAF8N0 user manual

NEFF

NEFF D64XAF8N0 user manual

Fisher & Paykel IZONA HC90 installation instructions

Fisher & Paykel

Fisher & Paykel IZONA HC90 installation instructions

Siemens LR97CAP21B user manual

Siemens

Siemens LR97CAP21B user manual

ETNA 4172WT User instructions

ETNA

ETNA 4172WT User instructions

PRO SIGNAL PSG3026 quick start guide

PRO SIGNAL

PRO SIGNAL PSG3026 quick start guide

Fisher & Paykel HI120 installation instructions

Fisher & Paykel

Fisher & Paykel HI120 installation instructions

NuTone F402401 instructions

NuTone

NuTone F402401 instructions

Broan Quiet Hood QT20000 SERIES installation instructions

Broan

Broan Quiet Hood QT20000 SERIES installation instructions

Best UP26M SERIES installation instructions

Best

Best UP26M SERIES installation instructions

Electrolux EFDP 90690 user manual

Electrolux

Electrolux EFDP 90690 user manual

Designair AGS60BK manual

Designair

Designair AGS60BK manual

KOBE CH2230SQ Installation instructions and operation manual

KOBE

KOBE CH2230SQ Installation instructions and operation manual

Accurex XB Installation, operation and maintenance manual

Accurex

Accurex XB Installation, operation and maintenance manual

GE JGP300EK Use and care guide

GE

GE JGP300EK Use and care guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.