2Heat & Glo • TIARAI-C • 7066-100 Rev. D • 12/11
Read this manual before installing or operating this appliance.
Please retain this owner's manual for future reference.
Congratulations
Congratulations on selecting a Heat & Glo gas appliance -
anelegantandcleanalternativetowoodburningappliances.
TheHeat&Glogasapplianceyouhave selected is designed
to provide the utmost in safety, reliability, and efficiency.
As the owner of a new appliance, you'll want to read and
carefully follow all of the instructions contained in this
Owner's Manual. Pay special attention to all Cautions and
Warnings.
ThisOwner'sManualshouldberetainedforfuturereference.
We suggest that you keep it with your other important
documents and product manuals.
Your new Heat & Glo gas appliance will give you years of
durable use and trouble-free enjoyment. Welcome to the
Heat & Glo family of gas appliance products!
ELECTRICAL SUPPLY / FOURNITURE ÉLECTRIQUE: 120 Volts, 60 Hz
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes.
See owner’s manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used. / Cet appareil doit être utilisé seulement avec le gaz indiqué sur l’étiquette enregistré et
peut être installé dans une maison mobile en place permanente dans les endroits permis par les codes locaux.Voyez le manuel du propriétaire pour des détails supplémentaires. Cet appareil ne doit pas être
converti avec des autres gaz sans l’utilisation d’un ensemble de conversion certifié.
MINIMUM CLEARANCES TO COMBUSTIBLES /ESPACE MINIMUM AUX COMBUSTIBLES
Minimum clearances required from combustible construction for all appliance surfaces.
Espaces minimum exigés de la construction combustible aux surfaces de l’appareil.
Date of Mfg /
Date du
Manufacturier
2010 2011 2012 Feb Mar Apr May Jun Jul Aug Sep Oct Nov DecJan DO NOT REMOVE THIS LABEL /
NE PAS ENLEVER L’ÉTIQUETTE
WARNING: Operation of this appliance when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. AVERTISSEMENT:
L’opération de cet appareil lorsqu’il n’est pas connecté à un système de ventilation correctement installé et maintenu peut résulter à un empoisonnement d’oxyde de carbone ou même de mort possible.
Right and left sides of appliance are determined when facing the front of appliance. / Les
côté gauches et droits de l'appareil sont d
éterninés
lorsque vous
êtes en face de l'appareil.
HEARTH: A non-combustible hearth pad is not required. However, the floor beneath the appliance must be stable, level, and strong enough to support the
appliance without a tipping hazard. / CHEMINÉE: Un coussinet non-combustible de cheminée n’est pas exigé. Cependant, le plancher en dessous du
poêle doit être droit, à niveau et assez fort pour supporter le poêle sans le hasard de basculer.
Made in U.S.A. of US and imported parts. / Fabriqué aux États-Unis-d’Amérique par des pièces d’origine américaine et pièces importées.
A. Side of stove top to side wall 8-1/2" (216mm) D
u côté du poêle au côté du mur
B. Rear of stove to back wall 1/4" (6mm)
Le contrôle arrière au mur arrière
C. Corner of stove top to side wall 3/8" (9mm) Du coin du dessus du po
êle au mur de côté
D. Minimum Alcove Height 54" (1372mm) Ha
uteur minimum du plancher au plafond
E. Maximum Alcove Depth 36" (914mm) P
rofondeur maximum de l'alcove
F. Minimum Alcove Width 40" (1016mm)
Largeur minimum de l'alcove
G. Stove to Ceiling Clearance 27" (686mm) Le po
êle au dégagement de plafond
H. Top of Pipe to Combustible 1-1/2" (38mm) Le sommet de tuyau à combustible
Side of Pipe to Combustible 1" (25mm) Le côté de tuyau à combustible
Inside Outside Cornerwall Vent 9" (229mm) À l'intérieur de conduit de mur de coin extérieur
G-Alcove
A
F
de l'alcôve
90° off top up & out ceiling
clearance 90° du sommet en
haut et hors le degagement
de plafond
A
B
E
AA
G
D
H
C
C
A, B & C measurements are from stove top, not side /
"A, B & C" mesure est du sommet de poêle, pas le côté
VENTED GAS FIREPLACE HEATER
NOT FOR USE WITH SOLID FUEL
Serial No / Numéro du
Report No. / Rapport Numéro
3198461
This appliance equipped for altitudes 0-2000’ (0-610m) in USA; and in Canada for altitudes of 0-4500’(0-1370m). In USA for Altitudes above 2000’, the vent configuration, orifice or combination of both may need to be
changed. See Owner’s Manual for information on making these changes. This appliance must be installed in accordance with local codes, if any (and Commonwealth of Massachusetts approved); if none, follow ANSI
Z223.1/NFPA 54 in USA, or CSA B149.1. in Canada. Install and use only in accordance with manufacturer’s installation and operating instructions.
NOTE: Have the gas supply line installed in accordance with local building
codes by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts, installation must be performed by a licensed plumber or gas fitter.) /
Cet appareil est équipé pour les altitudes
de 0-2000’ (0-610m) aux États-Unis; et au Canada pour les altitudes de 0-4500’(0-1370m). Pour les altitudes au dessus de 2000’ aux États-Unis, la configuration du ventilateur, son orifice ou les deux peuvent possiblement
avoir à être changé. Voyez le manuel du propriétaire pour les informations sur ces changements. Cet appareil doit être installé en accord avec les codes locaux, s’il-y-a lieu (et approuvé par dans la République de
M h tt ) i li ANSI Z223 1/NFPA54 CSAB149 1 I t ll t tili d l i t ti d’i t ll ti t d’ é ti d f t i REMARQUE L d it d itêt i t llé f é t
FOURNAISE AU GAZ AVEC VENTILATION
NE PAS UTILISER AVEC LE COMBUSTIBLE SOLIDE
MODEL / MODÈLE:
TIARA I-C GAS STOVE
Thermal Efficiency with blower on* 80.92% NG / 82.44% LP (* With Maximum horizontal length)
CAN/CSA P.4.1-02 Canada Minimum pipe Top Vent: 58.90% NG / 60.09% LP. Rear Vent: 65.04% NG / 66.49% LP
007021
0-2000 FT 0-2000FT
Input Rate on “HI” (BTU/Hr) 30,000 28,500 Puissance Évaluée à “HI” (BTU/Hr) - Évent Supérieur
Input Rate on “LO” (BTU/Hr) 21,000 19,700 Puissance Évaluée à “LO” (BTU/Hr)
Maximum Output (BTU/Hr)** 24,276 23,495 Puissance Maximum (BTU/Hr**
Main Burner Orifice .106 (#36 DMS) .063 (#52 DMS) Orifice du Brûleur Principal
Input Rate on “HI” (BTU/Hr) 26,000 26,000 Puissance Évaluée à “HI” (BTU/Hr) - Évents Arrière
Input Rate on “LO” (BTU/Hr) 18,000 19,000 Puissance Évaluée à “LO” (BTU/Hr)
Main Burner Orifice .098 (#40DMS) .059 (#53DMS) Orifice du Brûleur Principal
Minimum Inlet Pressure
(Inches W.C.)
5” 10” Pression Minimum de la Valve (pouces W.C.) - Tout Ensemble
Maximum Inlet Pressure
(Inches W.C.)
11” 13” Pression Maximum de la Valve (pouces W.C.)
M
anifold Pressure on
“HI”
(Inches W.C.)
3.5” 10” Pression du Collecteur d’ Échappement à “HI” (pouces W.C.)
AFUE 79.15% 80.62% AFUE
**Max Venting, Blower On **Ventilation Maximum, Ventilateur Allumé
For use with Propane
Usage Au Gaz Propane
For use with Natural Gas
Usage Au Gaz Naturel
APPROVEDFOR CANADA ANDUSA TO: ANSI Z21.88b-2009/ CSA2.33b-2009 Vented GasFireplace Heaters,andapplicable sections
ofUL307bGasBurningHeating AppliancesforManufacturedHomesandRecreational Vehicles, CAN/CGA2.17-M91 “GasFiredAppliances
foruseat HighAltitudes.”This appliance ismanufactured for operationwithNatural Gas.Forconversion topropaneManufacturer’sinstructions
must be used. This appliance may be installed in a bedroom or bedsitting room; in Canada remote thermostat installation is required.
APPROUVÉ POUR LE CANADA ET LES ÉTATS-UNIS: ANSI Z21.88b-2009 / CSA 2.33b-2009 Fournaises au Gaz avec Ventilation, et les sections
applicabledeUL307bAppareils de ChauffageAuGazpourlesMaisonsMobiles et lesVéhiculesMotorisés,CAN/CGA 2.17-M91 “GasFiredAppliances
for use at High Altitudes”. Cet appareil est manufacturé pour l’opération avec le Gaz Naturel. Pour une conversion au gaz propane Manufacturier
instructionsdoiventêtreutilisées.Cetappareil peut êtreutilisédansunechambreà coucherousalledeséjour;au Canada, l’installationd’unthermostat
à distance est exigée.
FAN TYPE VENTED CIRCULATOR :Optional Blower Kit #GFK-160A. 120 Vac, 60 Hz., 12 Amperes or less.
Route power cord away from unit. Do not route power cord under or over stove. VENTILATEUR CIRCULATOIRE: Le Souifleur Optionel Kit #GFK-160A. 120 Vac, 60 Hz., 12 Amperes ou moins.
Éloignez le fil électrique de l’appareil. Ne pas faire passer le fil électrique au dessous de l’appareil.
Efficacité thermique* avec ventilateur allumé 80.92% NG / 82.44% LP (* avec longueur horizontale maximum)
CAN/CSA P.4.1-02 Le canada tuyau minimum Top Vent: 58.90% NG / 60.09% LP, Rear Vent: 65.04% NG / 66.49% LP
1445 North HIghway
Colville, WA 99114
www.quadrafire.com
Top Vent:
Rear Vent:
Both:
Mfg Date
Serial
Number
Model
Name
Test Lab &
Report No.
SAMPLE OF SERIAL NUMBER / SAFETY LABEL
LOCATION: HANG TAG ATTACHED TO REAR OF APPLIANCE
SIDE A
SIDE B
SAMPLE