HeatLink 46543 User manual

#46543 User Guide
HeatLink Digital Thermostat
L646543
November 6, 2007
Page 1
Parameter Display
Temperature Unit
Decimal
Degree Symbol
Indicates Temperature Display
is measured
Temperature Display
Heat Demand Indicator
Cooling Demand Indicator
FREEZE PROTECTION
COMFORT MODE
AUTO-SETBACK MODE
SETBACK MODE
Screw Cover
(not a button)
Left Minus Button
Right Plus Button
OK button
The
46543 HeatLink Digital Thermostat
is a 24Vac electronic thermostat
designed to provide accurate temperature control of hydronic oor heating
systems. Features include:
•
Large 2" (50 mm) LCD display, with a large temperature display.
•
Proportional plus Integral (PI) controlled temperature regulation.
Proportional moves quickly to the desired setpoint and slows down when
the desired setpoint is near. Integral compensates the proportional offset
(overshoot) and stays close to the setpoint.
•
Fast switching between modes; temperature setpoint is adjustable at the
press of a button.
•
Accepts timer signal for automated setback operation (requires 46643
Timer Thermostat or 46673 Heat/Cool Thermostat).
•
Floor warming functionality is available through NTC terminal by adding
an optional 10K oor sensor; the sensor acts as a oor temperature limiter
(min / max oor temperatures are adjustable in the Parameter Menu).
Technical Information
Measured temperature precision
0.1°C (or 0.2°F)
Operating temperature
0°C - 50°C (or 32°F – 122°F)
Setting temperature range
5°C - 37°C by 0.5°C step
(or 41
°
F - 99°F by 0.5°F step)
Regulation characteristics
Proportional Integral regulation
(adjustable, see installation menu)
or Static differential 0.3°K
Electrical protection
Class II - IP30
Power supply
24 Vac +/- 10%
Output
TRIAC output 24 VAC, 15 W max.
(4 actuators)
External oor sensor
(sold separately)
NTC (10K Ohms)
C C R W NTC
Actuators (4 max)
C
R
24 V
ac Class II
24 Vac Class II24 V
T
ransformer
L
N
24
V
1
10
V
or
220
V
Floor Sensor
(optional)
Setback Signal Input
(optional)
46543
Color-coded Wiring Scheme
Wire FAS105 (red jacket)
StatLink® default
C
green
R
blue
W
red
black
Wiring Diagram

#46543 User Guide
HeatLink Digital Thermostat
L646543
November 6, 2007
Page 2
#46543 User Guide
Mounting Hole
Wiring Terminals
Back Terminal Plate
Wiring Hole
➂➂➂
➂
➂
➂➂➂
➂
➃
➃
➄
Screw Cover
(removed)
Center Screw
Front Control Panel
➀
➁
➅
➅
Installation
➀
Remove the Screw Cover.
➁
Remove the Center Screw to separate the Front Control Panel and
Back Terminal Plate.
➂
Mount the Back Terminal Plate using the supplied screws.
➃
Pull the Wiring through the Wiring Holes.
➄
Loosen the Wiring Terminals screws, connect the wires to each of the
terminals as per the wiring diagram, and tighten the screws.
➅
Finish the install by placing the Front Control Panel on to the Back
Terminal Plate, fasten the Center Screw, and replace the Screw Cover.
Mounting Location
•
Mount the thermostat at 5' (1.5 m) from the oor
•
Mount on inner walls only, and at least 2' (0.6 m) away from any outer
wall. Avoid entrances.
•
Mount away from any direct heat sources like: air vents, radiators, and
lights.
•
Avoid Moisture, it is damaging to electronics, so avoid installing
in areas that would contain high humidity or condensation (e.g.
bathrooms or greenhouses).
•
Do not cover or enclose, allow for proper air circulation, to get a good
measurement of the current air temperature.
Auto-setback mode
(Requires a timer setback signal)
In auto-setback mode, the 46543 operates automatically between
comfort mode (
blinking) and setback mode (
blinking)
according to the schedule of a timer thermostat (46643 or 46673).
Freeze Protection mode
In Freeze Protection mode: instead of simply turning the system
off, this thermostat prevents freezing by maintaining a
6°C (43°F)
minimal temperature. This mode is ideal for unoccupied buildings.
Setback mode
In setback mode, the temperature is set lower to conserve energy, the
default is
17°C (63°F)
. This mode is ideal for areas that are unoccupied.
To change the setback temperature (while in setback mode):
PRESS
OR
to change the setpoint to a lower
(-) or higher (+) temperature
PRESS
The Current Setpoint Temperature will blink
indicating that it can be changed
PRESS
to con rm the desired setpoint
The Measured Temperature will
return after 5 seconds
Comfort mode
In comfort setpoint mode, the temperature is set to a comfortable level,
the default is
21°C (70°F)
. This mode is ideal for occupied areas. To
change the comfort setpoint temperature (while in comfort mode):
PRESS
OR
to change the setpoint to a lower
(-) or higher (+) temperature
PRESS
The Current Setpoint Temperature will blink
indicating that it can be changed
PRESS
to con rm the desired setpoint
The Measured Temperature will
return after 5 seconds
FREEZE PROTECTION
COMFORT MODE
AUTO-SETBACK MODE
SETBACK MODE
PRESS
OR
To cycle through the modes
User Operation
In all modes, if a oor sensor is installed,
blinking indicates that the oor temperature is outside the limits set by the
FL
and
FH
parameters.
FH parameters.FH

#46543 User Guide
#46543 User Guide
HeatLink Digital Thermostat
L646543
November 6, 2007
Page 3
Con guration
This thermostat comes pre-con gured for a radiant oor heating system with a separate
boiler control and should normally not need further adjustment. The parameters can be
adjusted for ne tuning the system or adapting to other applications.
To access the Parameter Menu PRESS
& HOLD
For 5 seconds
After 30 seconds of non use the thermostat will automatically exit the Parameter Menu.
OR
PRESS
to cycle though parameters
&
PRESS
to reset a parameter to its
factory default
J1
: adjusts the type of
system
(default:
"Hot"
)
the thermostat can be used
for heating OR cooling
Cy
: PI regulation time cycle
Cy: PI regulation time cycle Cy
in minutes
(default:
6
minutes)
Range: 1-99, A0-A9 {100-
109}, B0-B9 {110-119}, C0
{120}
The constant time cycle the
thermostat uses to translate
the % output from the PI
calculation to an on/off time
of the heat demand.
On
: Minimum call for heat
in minutes
(default: 0 minutes)
Range: 0 - half the PI time
cycle (Cy)
OF
: Minimum interval
OF: Minimum interval OF
between on cycles in
minutes
(default: 0 minutes)
Range: 0 - half the PI time
cycle (Cy)
bp
: PI regulation band
amplitude value in degrees
(default:
1.5°C/2.7°F
)
Range: 0.01-12.7
The on (100%) / off
(0%) point during the PI
operation
PRESS OK Button
to switch between
"Hot"
(Heating) and
"
CLd"
(Cooling)
(Cooling)
PRESS OK Button
screen starts to blink
indicating adjustment
PRESS OK Button
screen starts to blink
indicating adjustment
PRESS OK Button
screen starts to blink
indicating adjustment
PRESS OK Button
screen starts to blink
indicating adjustment
PRESS "
-
" or "
+
"
To change value
PRESS "
-
" or "
+
"
To change value
PRESS "
-
" or "
+
"
To change value
PRESS "
-
" or "
+
"
To change value
PRESS OK to validate
PRESS OK to validate
PRESS OK to validate
PRESS OK to validate
Grey shaded parameters should only be adjusted by a heating professional.
End
: exits the Parameter
Menu
J0
: adjusts the temperature
scale (default:
"°C"
)
PRESS OK Button
to exit the parameter menu
PRESS OK Button
to switch between
°C
and
°F

#46543 User Guide
HeatLink Digital Thermostat
L646543
November 6, 2007
Page 4
J4
: actuator type selection
(default:
"NC"
or
normally
closed)
J5
: perform a 1 minute
J5: perform a 1 minute J5
pump exercise each day if
system inactive
(default:
"Pnp"
)
J6
: temperature sensor
(default:
"Air"
)
J7
: adjusts the type of
system regulation
(default:
"rEG"
)
Cp
: compensation value
(default:
2.0°C/3.6°F
)
Range: 0.00-12.7
DO NOT ADJUST
PRESS OK Button
to switch between
"NC"
(normally closed) &
"
NO"
(normally open)
PRESS OK Button
to switch between
"Pnp"
(exercise) and
"
no"
(no)
PRESS OK Button
to switch between
"Air"
(air sensor) and
"
FLr"
( oor sensor)
For combined operation select
"Air" and connect oor sensor.
PRESS OK Button
to switch between
"rEG"
(proportional
integral) &
"
HYs"
on/off (parameters
Cy, On, Of, bp & cp don't
apply)
apply)
Ao
: Air sensor calibration;
displays measured air
temperature
(default:
no offset)
Range: ±10°
adjust to show actual room
temperature
Fo
: Floor sensor calibration;
displays measured oor
temperature
(default:
no offset)
Range: ±10°
adjust to show actual oor
temperature
FL
: oor temp. LOW limit
(default:
18.0°C/64.0°F
)
Range:
5°C - 0.5° below
FH
(41° - 0.5° below
FH
)
FH
: oor temp. HIGH limit
(default:
28.0°C/82.0°F
)
Range:
0.5° above
FL
- 37°C
(0.5° above
FL
- 99°F)
CLr
: resets all parameters
to factory defaults
PRESS OK Button
screen starts to blink
indicating adjustment
PRESS OK Button
screen starts to blink
indicating adjustment
PRESS OK Button
screen starts to blink
indicating adjustment
PRESS OK Button
screen starts to blink
indicating adjustment
PRESS & HOLD OK Button
for 5 seconds
to reset all parameters
to reset all parameters
PRESS "
-
" or "
+
"
To change value
PRESS "
-
" or "
+
"
To change value
PRESS "
-
" or "
+
"
To change value
PRESS "
-
" or "
+
"
To change value
PRESS OK to validate
can only be reset by using
the ‘Clr’ function
PRESS OK to validate
can only be reset by using
the ‘Clr’ function
PRESS OK to validate
PRESS OK to validate
Table of contents
Other HeatLink Thermostat manuals
Popular Thermostat manuals by other brands

HaiLin Controls
HaiLin Controls HA202 user manual

Siemens
Siemens RDD100.1 DHW instruction manual

Trane
Trane TAYSTAT 370 owner's guide

Lux Products
Lux Products Luxpro PSP611 Installation and operating instructions

Horstmann
Horstmann ChannelPlus H37XL Series 2 User operating instructions

INSTEON
INSTEON 2732-232 owner's manual