'LVSOD\GLVDSSHDUVRQWKHUPRVWDW
- Check batteries.
- Replace the 2 batteries. Only use alkaline 1.5V AA (LR6) batteries.
Do not use rechargeable batteries.
The heating does not come on or does not go off.
- Your room thermostat may have been set up close to a source of heat
or on a cold wall – put it in a recommended location (see the “Installing”
section on page 2 for these locations).
- Check that the radio communication works between the thermostat
and the receiver.
- Check if the boiler controlled by the programmable room thermostat is
properly connected to the receiver.
5DGLRWUDQVPLVVLRQLVQRWZRUNLQJSURSHUO\
7KHUHFHLYHULVQRWSLFNLQJXSWKHFRGHVHQWE\WKHWKHUPRVWDW
- Check and replace thermostat batteries .
2- The receiver does not recognize transmitter’s code.
- Pair the room thermostat transmitter with the receiver again See Pairing
section.
7KHUHFHLYHURUWKHWUDQVPLWWHULVDIIHFWHGE\LQWHUIHUHQFH
- Re site the transmitter.
- If possible, re site the receiver away from the source of the interference.
<RXZDQWWRFKDQJHWKHRSHUDWLQJPRGHEXWZKHQ\RXPRYHWKHPRGH
slider nothing happens.
- If the lock symbol is being displayed, then the thermostat is locked.
- Unlock the thermostat by following the instructions for doing so in the
"program lock" section (see page 3).
7KHWKHUPRVWDWLVLQ$XWR0RGHEXWSURJUDPVDUHQRWEHLQJH[HFXWHGE\
the boiler:
- Ensure that the thermostat is in good working condition.
- Change the batteries.
Compliance declaration: we hereby declare under our
sole responsibility that the products described in these
instructions comply with all the main requirements of the LVD
2006/95/EC, EMC 2004/108/EC, RoHS 2011/65/EU and are
PDQXIDFWXUHGXVLQJSURFHVVHVZKLFKDUHFHUWLÀHG,62
V2008.
TROUBLESHOOTING
TECHNICAL SPECIFICATIONS
Power supply: 2 alkaline 1.5 V AA (LR6) batteries.
%DWWHU\OLIHDSSUR[\HDUV
Receiver:
- Power supply: 230V~50/60Hz.
- Relay outputs: 5(2)A.
- Rated impulse voltage: 4000V.
- Micro-disconnection: Type 1B.
- Pollution degree: 2.
- Automatic action: 100,000 cycles.
- Class II.
0D[LPXP UDQJH LQ WKH KRPH 15m is typical but this varies depending
on the building construction eg plasterboard lined with metal foil the
number of walls and ceilings that the signal has to pass through and by
the surrounding electromagnetic environment.
Signal sending:HYHU\PLQXWHVPD[LPXPWLPHODJPLQXWHDIWHUVHW
point temperature has been changed.
Standards:
Environment :
- Operation temperature: 0°C to +40°C.
- Manual temperature setting range: from +5°C to +30°C.
- Storage temperature: from -10°C to +60°C.
- Humidity: 80% at +25°C (without condensation)
- Protection rating: IP30.
N.B.: this room thermostat is one part of a complete radio system and will
only work with the 230V AC receiver. Radio emitter, frequency from 2.40
to 2.48 GHz.
Manufactured by: IMHOTEP création.
The on the product indicates that you must dispose of it at the end of
its useful life at a special recycling point, in accordance with European
Directive WEEE 2012/19/EU. If you are replacing it, you can also return it to
the retailer from which you buy the replacement equipment. Thus, it is not
ordinary household waste. Recycling products enables us to protect the
environment and to use less natural resources.
Transmitter Receiver
6DIHW\ R&TTE EMC RoHS 6DIHW\ R&TTE-EMC RoHS
EN62311
EN301489-1
EN301489-3
EN300440-1
EN300440-2
EN50581 EN60730-1
EN62479
EN301489-1
EN301489-3
EN300440-1
EN300440-2
EN50581
• Select 2 points/TPI
The pre-set control algorithm is TPI.
2 points = ON/OFF regulation.
TPI = Proportional control algorithm.
Note regarding the Advanced installer settings: If MODE slider is moved or
QRSUHVVURWDWLRQIRUVHFRQGVLWZLOOGLVFDUGFKDQJHVDQGH[LWLQVWDOOHU
mode.
1- Rotate the dial to ON and
locked.
2- Then save by pressing or
move the Programming slider.
1- Rotate the dial to change to 2
points control algorithm.
2- Then save by pressing or
move the Programming slider.
The radio link between the thermostat and the receiver is lost.
- Check the battery level status.
- Check that the radio communication works between the thermostat
and the receiver.If the radio communication does not work between
the receiver and the thermostat.
- Repeat the pairing between the thermostat and receiver (refer to
the user instructions).
7KHWKHUPRVWDWGRHVQRWFRQWUROSURSHUO\
7KHUPRVWDWVHQVRUPD\EHLQÁXHQFHGE\DVRXUFHRIKHDWRUFROG
- Check that the radio communication works between the thermostat
and receiver.
,IWKHSUREOHPSHUVLVWVFRQWDFW\RXULQVWDOOHU