HeatLink TR3100 User manual

TR3100 Thermostat Instructions
See overleaf for further setting up information
This thermostat is a combination model allowing you to
choose between 3 different models. A, AF and F model.
A
model: air onl
y, with built in sensor
AF model: air & floo r , with both built in and remote sensor
F model: floor only, with remote sensor
General Settings
Press buttton to Turn on/off the thermostat. When thermostat is turned off, the LCD will only display current temperature reading.
When the thermostat is
turned off, press and hold button M for 3 seconds to bring up a configuration menu. In this mode, press button M to select different features’ setting.
(Part I)
Menu #
1 Model (model selection)
Sd (switching differential)
ATC (air temp calibrate)
FTC (floor temp calibrate)
TR--AF (AF model only)
(TR= Temperature readout )
MAXFT (set maximum floor
temp in AF model)
BL (backlight turning-on time
setting)
TF (temperature format)
CLOCK
24 (default), 12- hour or 24-hour clock system
PTD (program time delay)
2
3
4
5
6
7
8
9
10
11
12
Features description Features Explanation Adjustment
1 = 1 degree(default), 2 =2 degrees.........
-1 = decrease 1 degree, 1 = increase 1 degree...
5s , 10s , 15s ,20s (default) , 25s, 30s.
A= to show air temperature, F=to show floor temperature,
A--F = to show both in 5 second intervals
40 degree(default)
30 seconds(default) On= always on, OFF= always off
C or F
A, AF, F
(press up or down button to adjust)
-1 = decrease 1 degree, 1 = increase 1 degree...
This product should be installed by a qualified electrician.
If the floor sensor is short-circuit or broken, the LCD will display “Err” and the thermostat will cut off output.
Please Note: one of the following error messages will appear if one of these problems occur:
The numbers of degree difference before switching.
The default is 1°C which means the thermostat will
switch the
heating on 0.5°C below the set temperature
and will turn it off 0.5°C above the set temperature.
With a 2°C differential,
the heating will switch on 1°C
below the set temperature and will switch off 1°C
above the set temperature.
This is to calibrate air temperature if required.
This is to calibrate floor temperature if required.
This gives more time for user to set the programmes
before reverting back to standard display
This gives option to choose to show air temperature,
floor temperature or to show both floor & air in interval.
This is to protect the floor surface.
This is to set the backlight turning-on time. User
can also set the backlight always on or off.
This alows users to select between °C or °F.
12/24 HOUR clock system selection
Buttons and LCD display
Button / Icon Description
Turning on/off thermostat
Menu button / Program button
Auto/Manual mode selection
Increase the set value
Decrease the set value
Set the time and week days
M
The buttons are locked.
Heating is turned on
Button / Icon Description
Auto mode(select by button M)
Manual mode(select by button M)
Vacation mode
Temporary temperature override
Frost protection activated
Set temperature
Programmes number
Room temperature
RT
AUTO
SET
Floor temperature
Economy temperature
Comfort temperature
FT
The difference between set
temperature and room temperature
more bars means more difference
override
SC(setpoint configuration)
“2” means: set temperature in program 1 equals the set temperature in
“4” means the 4 programmes will have 4 independent set temperatures.
Each set temperature can be different to the others.
program 3 ; set temperature in program 2 equals the set temperature in
program 4 ; If set temp in program 1 is changed, set temp in program 3
temp in program 2 is changed, set temp in program 4 will be changed
will be changed automatically to the same set temp as program 1. If set
automatically to the same set temp as program 2.
This allows user to select between 2 sets of default
programmed setpoints.
FP(Frost protection) on= activated, off= deactivated
This is to avoid room temperature goes below 5
°C
Ver.1.3
Optional Remote Controller
(TR3100RC model only)
Turn on/off thermostat
Lock or unlock buttons
Menu(in OFF mode)
Confirm setting
Vacation mode
Program button
Set day
Set time
View floor temp
(AF model only)
Cancel Override
Auto/Manual selection
Increase the set value
Decrease the set value
Prog
TimeDay
Auto
Manu
Prog
Menu
Enter
TimeDay
Auto
Floor
Temp
Run
Schl

TR3100 Thermostat Instructions (Part II)
Ver.1.3
To temporary override the current set temperature,
1. Press up or down button once, the set temperature starts flashing
2. Press up or down button again to adjust the set temperature
3. Wait for 5 seconds to confirm the setting with “OVERRIDE” shown on LCD
Now your thermostat will maintain the new set temperature until the next setpoint. To
cancel the override setting, press and hold button for 5 seconds until “OVERRIDE”
Press button M to select Auto/Manual mode. In Manual mode, the thermostat maintains a constant set
temperature manually set by the user. In Auto mode, the thermostat executes the preprogrammed schedules.
To adjust these schedules, follow the easy steps below,
To set vacation mode press and hold the up button for 3 seconds until appears. Use
same procedure to exit this mode.Vacation mode
up or down button to change the set point and wait for 5
will maintain a set temperature(default
Your thermostat has the ability to reset all settings to the factory defaults. If you are
certain you want to do this: In standby mode(when thermostat is turned off), press
If thermostat is set in AF model, and set to show air temperature only, press and
automatically revert back to air temperature in 5 seconds.
hold the down button for 3 seconds, floor temperature will show and it will
This product should be installed by
a qualified electrician.
Installation and Wiring
Dimensions
Wiring Diagram
86mm
mm68
Rear View
45mm
13mm
27 mm
26 mm
Side View
60mm
mm68
86mm
4mm
mm7
LL
LOAD
(16A)
FEED
(220VAC+/-15%)
Floor Sensor
NN
To lock the buttons, press and hold the up and down buttons for 3 seconds until you
see a lock icon appearing, to unlock, repeat the steps above.
and hold
button M and for 5 seconds until “RESET” is shown for 5 seconds on LCD.
This thermostat is fitted with a real time clock. It is essential that the clock time and day
are set accurately if you require your programmed events to start on time. Follow the
Set the Time and Day
Auto / Manual Mode
Program your thermostat
Resetting factory defaults
Lock the buttons
View floor temperature
Temporary temperature override
Vacation mode
Press the button once
Use up or down button to change the time (Hold up or down button to change
Press button again, the day of the week will flash
Press button again to accept and exit
Use up or down button to change the day of the week
Press and hold button M for 5 seconds until “PROG” is shown with the Day flashing. Use up or
down button adjust the day (hold up or down button for 5 seconds to set all days the same).
To erase program 2 and 3 for Saturday and Sunday,see below,
Note: It is faster to program the same schedule for the entire week and then to adjust the
Press button M again and use up or down button to set the desired temperature to be
Press button M to accept and exit.
Press button M to bring up the program 1( ). Use up or down button to set the start time
In step 1, select Saturday or Sunday.
In step 4, instead of using up or down button , using button will erase the time.(--:--).
In step 6, instead of using up or down button , using button will erase the time.(--:--).
and the time will flashStep 1.
Step 2.
Step 3.
Step 4.
Step 5.
10
°C
) all the time. Press
Carefully separate the front half of the thermostat
from the back plate by placing a small flat head
terminal driver into the slots on the bottom face of
the thermostat
1
1
2
3
4
5
6
7
8
9
10
Carefully unplug the ribbon connector
which is plugged in to the front half of
the thermostat
2
Place the thermostat front half somewhere
safe. Terminate the thermostat as shown
in the diagrams below
3
Screw the thermostat back
plate on to the back box
4
Re-connect the thermostat ribbon cable
and clip the two halves together
5
(default 07:00).(Hold up or down button to change by 15 minutes each time.)
Press button M to bring up the program 2( ). Use up or down button to set the start time
(default 09:30). (Hold up or down button to change by 15 minutes each time.)
Press button M to bring up the program 3( ). Use up or down button to set the start time
(default 16:30). (Hold up or down button to change by 15 minutes each time.)
Press button M to bring up the program 4( ). Use up or down button to set the start time
(default 22:30). (Hold up or down button to change by 15 minutes each time.)
maintained for program 1.(default 22
°C
)
Press button M again and use up or down button to set the desired temperature to be
maintained for program 3.(default 22
°C
)
Press button M again and use up or down button to set the desired temperature to be
maintained for program 2.(default 16
°C
)
Press button M again and use up or down button to set the desired temperature to be
maintained for program 4.(default 16
°C
)
exceptional days.
below easy steps,
by 15 minutes each time.)
seconds to accept and exit.
disappear.
4
3
2
1
Table of contents
Other HeatLink Thermostat manuals
Popular Thermostat manuals by other brands

ICM Controls
ICM Controls SC1600L Installation, operation & application guide

Ariston
Ariston 3319483 Installation and operating instructions

emerio
emerio TFN-214472.1 instruction manual

domat
domat UC220 manual

Honeywell
Honeywell PRO 2000 Series Product information

Honeywell
Honeywell THX9000 Prestige HD installation guide