Heiko YR-HRC01 User manual


CONTENTS
1. Products Lineup ......................................................................................................................1
2. Remote controller....................................................................................................................2
2.1 YR-HRC01............................................................................................................................2
3. Wired controller .......................................................................................................................6
3.1 YR-C01.......................................................................................... .......................................6

1
1. Products Lineup
No. Control system Model Photo
1Individual control Remote Controller
2
YR-HRC01
YR-C01
Individual control Wired Controller

2
2.Remote controller
MRV
LCAC
Smart Power Super Match R410A ON/OFF R22 ON/OFF
√ √
•On/Off, Mode, Fan speed, Temperature setting, Swing
•°C/ °F selection
•Individual control
•Three grades of fan speed
•Individual blade control for Smart Power Cassette
•Clock & Timer
•Moving eye control (Follow/Evade function)
2.1YR-HRC01

3
External View of Remote Controller Loading of the battery
1. Remove the battery cover;
2. Load the batteries as illustrated.
2 R-03 batteries, resetting key
(cylinder); Be sure that the loading is
in line with the “+”/ “-”;
3. Load the battery, then put on the
cover again.
<1> <2> <3>
Functional description
1. Power-up and Show All: the LCD display shows all
symbols in this function. 3s later, it just shows time and
the initial time is AM 12:00. The initial time is adjustable
and will be conrmed automatically 10s later.
2. ON/OFF Button: press the button for power on. The
initial default mode is SMART, otherwise it will be the
mode before power OFF. Press OFF button after power
on.
3. SMART Button:
(1) SMART button is always valid during power ON/
OFF;
(2) Press SMART button to execute power OFF in
SMART mode;
(3) In OFF and other modes, press SMART button to
enter initial default setting of SMART mode. LCD setting
temperature is not showed;
(4) In SMART mode, press TEMP. +/- button to show
the setting temperature.
4. COOL Button, HEAT Button and DRY Button
(1) When the remote controller in ON, press COOL
button, HEAT button and DRY button to execute COOL
mode, HEAT mode and DRY mode.
(2) For initial power-up, temperature and fan speed
will be showed as follows when entering each mode,
otherwise parameters set last time will be showed;
Mode SMART HEAT COOL DRY FAN
Initial
TEMP. 24°C 24°C 24°C 24°C
Setting
temperature
is not
showed.
Mode SMART HEAT COOL DRY FAN
Initial
Fan
Speed
AUTO LOW HI AUTO LOW
5. FAN Mode
(1) During power OFF, press “HEALTH” button or
“FRESH” button to enter FAN mode with low fan speed.
Meanwhile, the HEALTH or FRESH icon will be showed
on the screen.
(2) Temperature is not showed in FAN mode.
(3) Auto fan speed is not available when switching fan
speed in FAN mode.

4
6. FAN SPEED Button:
(1) In other modes except for Fan mode, LOW, MED, HI
and AUTO fan speed is adjustable, switching sequence
is as LOW-MED-HI-AUTO-LOW.
LOW, MED and HI fan speed
circulate automatically
LOW MED HI AUTO FAN SPEED
(2) After TURBO or QUIET is set. Press TURBO
button to show on the screen with fan speed as
, then press “FAN SPEED” button to exit;
press QUIET button to show on the screen with
fan speed as , then press “FAN SPEED” button to
exit. To cancel TURBO and QUIET, press TURBO and
QUIET buttons respectively, and icons
will disappear and the fan speed will return to the last
one.
(3) This button is invalid during power OFF.
7. TEMP. +/- Button:
(1) This button is invalid in FAN mode;
(2) Temperature adjustment range in SMART, HEAT,
COOL and DRY mode: 16 ~30°C.
(3) Press and hold “TEMP. +/- “ button, the temperature
changes once; long press the button, the temperature
changes rapidly.
8. Four-side Embedment
(Available for some models):
(1) Initial position of all modes for rst power on:
SMART HEAT COOL DRY FAN
Four-side
Embedment
Show
all
Show
all
Show
all
Show
all
Show
all
SWING
Angle
Position
3
Position
5
Position
3
Position
3
Position
3
(2) After power on, press “Four-side Embedment” button
for the rst time and the recycle approach is as follows:
four-side simultaneous control of Four-side Embedment
→ Four-side Embedment 1 → Four-side Embedment
2 → Four-side Embedment 3 → Four-side Embedment
4 → Four-side simultaneous control of Four-side
Embedment.
(3) When pressing “Four-side
Embedment” button to select air deector, the selected
air deector ashes. Press “Up-and-down Angle” button
to adjust angle of air deector at the moment.
10. Right-and-left SWING Angle (Available for some
models):
Recycle approach: 34 showed (Position 1)→25 showed
(Position 2)→16 showed (Position 3)→1 showed
(Position 4)→2 showed (Position 5)→5 showed (Position
6)
→6 showed (Position 7)→Auto swing
Auto swing approach:
1→2→3→4→5→6→5→4→3→2→1 are
showed circularly.
9. Up-and-down SWING Angle:
1: Position 1; 2: Position 2; 3: Position 3; 4:
Position 4;
5: Position 5; 6: Position 6 (reserved)
Recycle approach: Position 1→Position
2→Position 3 →Position 4→Position
5→AUTO→Position 1
Auto swing: 1→2→3→4→5→4→3→2→1 is
showed circularly.
1
2
3
654
1
2
3
654
1236
5
4
11. HEALTH AIRFLOW (Available for some models):
Press "HEALTH AIRFLOW" button to show icon on
LCD display. Each air deector of swings on four sides
alternates circularly to indicate that the swing rotates
to exhaust air. Meanwhile, up-and-down SWING angle
shows AUTO SWING. Press it again to cancel HEALTH
AIRFLOW.
12. SLEEP:
(1) Valid during power on.
(2) The SLEEP time is fixed to 8 hours and is not
adjustable.
(3) It is invalid in FAN mode. When setting TIMER ON or
TIMER ON to TIMER OFF after setting SLEEP function,
once the timer setting is successful, the SLEEP function
will be cancelled; after setting TIMER ON or TIMER
ON to TIMER OFF, the SLEEP function cannot be set.
SLEEP function can be set from TIMER OFF to TIMER
ON, TIMER OFF and SLEEP function have priority in
canceling the opposite side.
13. HEALTH:
(1) During power-on or power-OFF, press “HEALTH”
button to display icon on LCD display, and press
“HEALTH” button again to cancel.
(2) During power-OFF, press “HEALTH” button to enter
Fan mode, start low wind and HEALTH function, display
icon .
(3) Switch among modes, and keep HEALTH function.
(4) If HEALTH function is set, power OFF and then on to
stay in HEALTH mode.
14. ECO:
(1) Press ECO button and the display will show .
(2) ECO is valid under all modes, it is memorized
among switch of all modes.
(3) ECO function power-on or power-OFF is memorized.
15. Turbo/Quiet:
(1) Press button “Turbo”, display icon on remote
LCD display, display icon of fan speed;
Press button “Quiet”, display icon on remote
LCD display, display icon of fan speed.
(2) Turbo and QUIET functions can not exist at the
same time, the latter will replace the former.
Show 1s Show 1s Show 1s Show 1s Show 1s

5
(3) If Turbo function is set, press “SLEEP” button to
exit turbo, which means that setting SLEEP function
while canceling turbo function. At the same time, the
icon disappears and icon is shown; if QUIET
function is set at present, press button “SLEEP” while
QUIET function is still kept.
(4) This function is valid under the mode of COOL or
HEAT.
(5) Turbo/QUIET functions are not memorized among
switch of all modes/the state of on or OFF.
16. IFP:
(1) Press “IFP” button, display , IFP function is
set, and press “IFP” button again to cancel.
(2) Press “Follow/Evade” button, display that
expresses following; press it again, display that
expresses evading. Press it the third time to cancel.
(3) If follow/evade functions are set, air-out angle will
change with position of people, so after setting these
functions, Four-side Embedment icons in all sides, up-
and-down SWING and left-and-right SWING icons will
disappear.
(4) If air conditioner is in the state of HEALTH airow,
follow/evade functions is set, HEALTH airow function is
cancelled, Four-side Embedment, up-and-down SWING
and left-and-right SWING icons will disappear.
17. FRESH:
(1) FRESH function is valid under the state of ON or
OFF. When air conditioner is OFF, press “FRESH”
button, display icon on LCD display to enter Fan
mode and low speed. Press “FRESH” button again, this
function is cancelled.
(2) After FRESH function is set, ON or OFF functions
are kept.
(3) After FRESH function is set, mode switch function is
kept.
18. 10°C Heating Function and °C/°F function
Press “MENU/°F” button to set 10°C Heating function
and °C/°F function. 10°C Heating Function is valid only
under the mode of HEAT, and it is not memorized under
the state of ON or OFF.
19. HEATER:
(1) When HEAT mode is chosen and is displayed on
LCD display, pressing “HEATER” button can cancel and
set HEATER function.
(2) Auto mode will not start HEATER function
automatically, but can set or cancel HEATER function.
20. Timer:
(1) TIMER ON
• Press “TIMER ON” button, character “ON” is ashing,
press “+/-“ button to adjust, then press “CONFIRM”
button to conrm, if “CONFIRM” button is not pressed
within 10 s, TIMER ON function is cancelled.
•If time of TIMER ON is the same as that of clock at
present, character “ON” is always ashing and can
not be veried, it is necessary to readjust time.
•When the time of TIMER ON is end, the setting time
and character “ON” disappear.
(2) TIMER OFF
•Press “TIMER OFF” button, character “OFF” is
ashing, press “+/-“ button to adjust, then press
“CONFIRM” to conrm, if “CONFIRM” is not pressed
within 10 s, TIMER OFF function is cancelled.
•If time of TIMER OFF is the same as that of clock at
present, character “OFF” is always ashing and can
not veried, it is necessary to readjust time.
•When the time of TIMER OFF is end, the setting time
and character “OFF” disappear.
(3) TIMER ON/OFF
•After TIMER ON/OFF is set, remote will automatically
judge sequential order of ON/OFF, arrow indicates
that the one performed rst points to the one performed
second.
• After the time of clock performed rst is end,
corresponding characters of timer “ON/OFF”
disappear.
•If time of TIMER ON is the same as that of TIMER
OFF, and can not be veried, corresponding character
of the latter of setting time is always ashing, it is
necessary to readjust time and conrm again.
•If time of TIMER ON/OFF is the same as that of clock
at present, and can not be veried, it is necessary to
readjust time and conrm again.
(4) After setting timer, display the setting of timer rst
and then display time all the time, when timer is active,
character “ON/OFF” is always displayed.
21. Button +/-:
Press button “+/-“, time will change in terms of 1 min as
unit, pressing and holding the button will change quickly.
22. Clock:
Press “Clock” button, “AM” or “PM” displayed at present
are ashing to enter the state of clock adjustment,
adjust clock and then press “CONFIRM” to conrm.
It is valid under the state of ON/OFF.
23. LIGHT:
No display on remote controller LCD, which is
processed by indoor unit.
24. RESET:
Perform one power on reset operation when RESET
button is pressed.
25. LOCK:
Press button Lock, display Lock symbol on LCD display,
buttons on remote controller can not be used, press
button Lock again to unlock.
26. CODE: Function reserved.
27. INQUIRE Function reserved.
NO. 0150519129

6
3. Wired controller
3.1 YR-C01
MRV
LCAC
Smart Power Super Match R410A ON/OFF R22 ON/OFF
√√√√
•On/Off, Mode, Fan speed, Temperature setting, Swing.
•Individual & Group control (Max.16 indoor units)
•Simple and Smart design, 86*86*13.05mm
•Touch button with back light
•Timer/ Clock
•Easy installation

7
B0TT0M CASE
>ABS<
Dimension

8
Parts and Functions
Interface Display
24-hour, press once to minus one minute. Keep pressing, minus 2 minutes in 1 second’s pressing, then 10
minutes in 5 seconds. The time will keep decreasing at the pace of 10 minutes a time in 10 seconds. Vice-versa.
Press to conrm or it will turn back to the previous state automatically in 10s.
Press this key to execute mode switch. For detailed information, please refer to mode setting.
Note: If using Fresh Air unit, default 3 modes will circulate from cooling→heating→fan→cooling.
Key
ON/OFF
Adjusting key for temperature, clock, timer, sleeping adjustment, temp. compensation and energy saving;
Inquiring key for detail parameter and malfunction inquiry;
Switching key for function switch.
The adjusting accuracy of temperature is 0.5°C. If energy saving mode is not set, the adjusting range is from 16°C
to 30°C. If energy saving mode is set, the lowest temperature limit of cooling/dry and the highest temperature
limit of heating are decided by the setting of the chip, the default cooling/dry temperature is 23°C, and the default
heating temperature is 26°C.
Note:
•If the dip switch Sw2 is “on”, it displays the ambient temp., as well as when powered off. From power off to power
on, mode switching and set temp. adjustment, it ashes to display SET icon and statically displays the set temp..
And then statically displays the ambient temp. and ROOM icon after 3 seconds. In energy saving mode and
temp. compensation mode, the adjusting step is 1°C a time.
• If using Fresh Air unit, set temp. cannot be adjusted. If there is no Central/Lock set, the temp. will be xed at 18°C
in cooling and 22°C in heating. The Up/Down key will not display in normal state, but will display and valid in timer
setting, function selection, unit shift in malfunction inquiry, parameter shift in parameter check, unit No. setting,
sleeping time adjustment, etc.

9
Fan
Time
Set
Timer ON, Timer OFF, Timer ON/OFF.
Pressing this key, fan speed will be changed in sequence as follows: (Low) →
(Medium) → (High)→ (Auto) → (Low)
Note: Auto fan will be changed in sequence as follows:
→ → →
Pressing this key, fan speed will be changed in sequence as follows (Only valid for parts of models):
(Breeze) → (Low) → (Medium) → (High) →
(Super) → (Auto) → (Breeze)
Auto fan circulation:
(Breeze) → (Low) → (Medium) → (High) →
(Super)
There is no auto fan in fan mode; The fan icon will ash when adjusting the fan speed. It will statically display after
the adjustment.
Note: If using Fresh Air unit, fan will be in auto fan and cannot be adjusted. If press FAN key, fan icon and FFFF on
the
top-right corner will ash, prompting fan speed cannot be adjusted, and will statically display after 3s. Fresh Air unit
fan speed will be controlled automatically by indoor unit and wired controller will always display auto fan.
Press this key to enter function circulation. If it is the four-way cassette model, press Set key for 5s to enter function
circulation.
1.Press to select the functions in sequence as follows:
(Only when Left/Right swing is valid) → (Only when Up/Down swing is valid) → → (ventilation function)
→ (reserved function) → → (When it’s time for lter cleaning, this icon will involve in circulation) → (the
second 8 of 88.8 in the temp. display area displaying A,only valid for part of models)→ (the second 8 of 88.8 in
the temp. display area displaying B,only valid for part of models)→ (motion sensing,only valid for part of models)
→10°C heating function (this function only works in the heating mode, only valid for part of models) → health airow
up (Only valid for part of models) → health airow down (Only valid for part of models)
2.Press to select the functions in sequence as follows:
health airow down (Only valid for part of models) → health airow up (Only valid for part of models) →10°C heating
function (this function only works in the heating mode, only valid for part of models) → (motion sensing,only valid
for part of models) → (the second 8 of 88.8 in the temp. display area displaying B,only valid for part of models)
→ (the second 8 of 88.8 in the temp. display area displaying A,only valid for part of models) → (When it’s time
for lter cleaning, this icon will involve in circulation) → → (reserved function) → (ventilation function)
→ → (Only when Up/Down swing is valid) → (Only when Left/Right swing is valid)
3. Press to conrm function selected. If there is function selected, press can cancel this function.
Note: The Left/Right swing is valid only after the dip switch is set, the lter icon is shown only after the lter
requires cleaning.

10
Clock; Parameter setting/inquiry; Malfunction display; Mode setting.
Timer ON/OFF: Sleeping; Parameter setting/inquiry; Malfunction display.
ROOM/SET temp. and humidity display, each step is 0.5°C . For example, if the temp. is 25°C, it
will display 25.0°C. Humidity display function is reserved.
Energy Saving, This icon will be displayed only when energy saving function is set.
Filter Cleaning.
Child Lock. This icon will be displayed only when child lock function is set.
/ Lock/ Central
Motion Sensing (Only valid for part of models).
Left/Right Swing. This icon is displayed in swing mode; no display without swing mode.
Up/Down Swing. This icon is displayed in swing mode; no display without swing mode.
Sleeping. This icon is displayed when setting the sleeping, and left time of sleeping is displayed
by
Heat Reclaim Ventilation, This icon is displayed when setting the heat reclaim ventilation.
Electrical Heating. This icon will display when electrical heating is set on DC wired controller.
Icon
Intelligent Mode.
Cooling Mode. Heating Mode.
Fan Mode. Dry Mode.
Breeze Fan Speed (Only valid for part of models)
Low Fan Speed.
Medium Fan Speed.
High Fan Speed.
Super Fan Speed (Only valid for part of models)
If the fan speed is set in auto fan, it will change in the following sequence: Breeze(Only valid for part of models)
→Low→Medium→High→Super (Only valid for part of models), AUTO icon will display simultaneously.

11
Dip Switch Interpretation ( for AC )
Difference beyween the Function of the Master Wired Controller and Slave Wired Controller
Initialization
Screen Saving
•Operation
DIP switch On/Off station Function Default setting
Sw1 On Slave wired controller Off
Off Master wired controller
Sw2 On Ambient temp. display on Off
Off Ambient temp. display off
Sw3 On Collect ambient temp. from PCB of indoor Off
Off Collect ambient Temp. from wired controller
Sw4 On Non-volatile memory invalid Off
Off Non-volatile memory valid
Sw5 On Old protocol Off
Off Self adaption
Sw6 On HRV is included in the system Off
Off HRV is not included in the system
Sw7 On Model with Up/Down and Left/Right swing Off
Off Model with Up/Down swing
Sw8 On Fresh Air unit Off
Off General unit
Comparison
item
Master wired
controller Slave wired controller
Function All functions are
available
1. ON/OFF, Mode, Fan Speed, Temp. Setting, Swing, Energy Saving,
Clock function, Heat Reclaim Ventilation function, Mode Setting, Screen
Saving and Child Lock are available
2.Cancel the lter cleaning icon
3.Look up the detailed parameter and malfunction code
(1)The wired controller will display all the icons after powering on or reset, then get into the initializing process. The
controller will display in sequence as follows: (the top-left corner) → (the top-right corner) → →
(the top-left corner), the green LED ashes all the time until the initialization ends.
(2) If the wired controller can’t be communicated with the indoor PCB normally after powering on, the initialization
will be nished in 4 minutes, and then the communication malfunction can be checked from the malfunction inquiry
function.
(1) In the state of off and non screen saving, keep pressing and for 5s to set screen saving time, which will
be shown after the top-right colon 88 statically. Press Up/Down key to adjust screen saving time and press key
to conrm.
(2) Screen saving time should be 0s(backlight always on), 15s, 30s, 60s, default value is 15s. If it is not the rst
time of entering, it will display the screen saving time adjusted last time.
(3) In the process of changing screen saving time, press ON/OFF key to quit screen saving time setting function, it
will recover to screen saving time before adjustment and start-up the unit.
Note:
When controlling Fresh Air unit, the controller main interface will not display Up/Down key in normal state. When in
screen saving setting, press Time key rst to display Up/Down key at the main interface, and then press together
Time and Down key to enter screen saving time setting.

12
(1) 24-hour system is used, and at rst time of powering on, it will display default 12:00.
(2) When rst powering on wired controller, will be displayed on the wired controller interface, clock time
can be adjusted within 10s. At the same time, clock icon and minute-place of time will ash, meaning the current
time can be adjusted.
(3) Press Time key for 5s to enter clock setting function. It will show after rst powering on (if not rst time
of powering on, clock time is the memorized time), with clock icon and minute-place ashing, meaning current time
can be adjusted.
(4) Press Time key to shift the hour place and the minute place. After adjustment the time, press set key to conrm.
(5) In the process of time adjustment, if there is no operation for 10s, it will quit and restore previous state.
(6) In the process of time adjustment, press ON/OFF key to quit clock setting function and execute turning on/off
operation at the same time.
(7) When setting timer or sleeping function, clock time cannot be adjusted. If press Time key for 5s to enter clock
adjustment, clock icon and clock time will ash indicating time cannot be adjusted.
Clock Function
Timer Function
Timer Setting Cancellation
Swing
(1) Timer mode setting: Timer ON, Timer OFF, Timer ON/OFF.
(2) Default: Timer ON is , Timer OFF is .
(3) Precision: The time precision is 1 minute. Timer clock is based on the current clock time; the adjustment is the
same as clock time.
(4) Press Time key, the timer function circulation is as follows:
ON and the Hour position are ashing→
ON and the Minute position are ashing→
OFF and the Hour position are ashing→
OFF and the Minute position are ashing→
ON and the Hour position are ashing→
ON and the Minute position are ashing→
OFF and the Hour position are ashing→
OFF and the Minute position are ashing→ the timer icon will disappear.
• The hour or minute position is ashing, press to adjust the timer, Keep pressing to accelerate the adjusting
speed, then to conrm the setting.
•The controller will judge the order of timer on and off and use the arrow to show the order. First ON then
OFF:ON→OFF, First OFF then ON:ON ←OFF.
•The ON/OFF button has no affection on timer setting. Under power off state, the Time key is valid.
(1) If there is no Time key related operation for 10s, this setting will be cancelled and the timer will come back to the
previous state.
(2) Press Time key, until the timer icon disappear, the timer function will cancel.
(3) Relation to other buttons when timer is set.
Press the key or key to exit the current setting, press them again to operate the function accordingly;
Press the (ON/OFF) key can exit the timer setting and power ON/OFF directly. If there is a timer before, the
wired controller will operate by following the previous setting. If not, the wired controller will have no timer operation.
(1) If Sw5 is on, only the Up/Down swing will be involved in function circulation. At this time SW7 is invalid.
(2) If Sw5 is off, swing type can be set by Sw7, when Sw7 is off, only Up/Down swing valid, when Sw7 turns on, Up/
Down and Left/ Right swing valid. Only Up/Down swing is default.
•If Sw7 is off (default): only Up/Down swing is available.
• Press SET key to enter function circulation, Up/Down swing icon ashing, then press SET key again to conrm
with swing icon statically displaying. If swing function is set, execute the above operation to cancel.
•If Sw7 is on: Up/Down swing and Left/Right swing are available.
• Press SET key to enter function circulation, Left/Right swing icon ashing, then press Up/Down key to enter Up/
Down swing, with Up/Down swing icon ashing. Press SET key again when swing icon ashing to conrm, with
swing icon statically display. If swing function is set, execute the above operation to cancel.
•If connecting to the salve wired controller, Sw7 dip code of master and slave wired controllers should be set the
same and should match the actual wired controller unit.

13
Health airow up/down function ( Only valid for part of models )
Sleeping
(3) If Sw5 is off, some models can self-adaptive the swing setting and swing angle control.
•If the angle of the Up/Down swing can be adjusted:
Press SET key to enter the function circulation; the Up/Down swing icon will ash. Press the SET key again; the
swing angle will ash(if powered on for the rst time, default angle will be different according to different modes;
if not for the rst time, the angle of swing will be displayed as last time). At this time, swing angle can be adjusted
by Up/Down key (when in intelligent mode, the swing angle is position 1,press up key to automatic swing, and
press down key to position 2).When pressing Up/Down key to adjust angle, If no operation in 10s, it will exist angle
adjustment and function circulation. Interface displays the last angle. If you want to set other functions like sleep
function, you need to press SET key again to enter function circulation.
•If the angle of the Up/Down and Left/Right swing can be adjusted:
Press SET key to enter the function circulation, and the Left/Right swing icon will ash. At this time, press Up/Down
key to switch to Up/Down swing icon ashing. When Left/Right swing icon ashing, Press SET key again, the angle
of Left/Right swing will ash(if powered on for the rst time, the default angle is in position 1, the middle position of
Left/Right swing icon; if not for the rst time, the angle will be displayed as last time).
(4) Pressing Fan key or Mode key can both exit swing function, with no order sending. When Fan or Mode key
is pressed again, the order will be sent. If the present angle is confirmed, pressing SET key will exit the swing
function. In the adjustment process, if there is no key pressed for 10s, swing function will be exited, and swing
angle will execute the nal adjusted angle. In the adjustment process, pressing the ON/OFF key to power off the
wired controller directly, and swing angle is the nal adjusted swing angle.
(1) The function can be set through wired controller or remote controller.
(2) The function circulation is as follows:
(Only when Left/Right swing is valid) → (Only when Up/Down swing is valid)→ → (ventilation
function)→ (reserved function)→ → (When it’s time for filter cleaning, this icon will involve in
circulation) → (the second 8 of 88.8 in the temp. display area displaying A,only valid for part of models)→
(the second 8 of 88.8 in the temp. display area displaying B,only valid for part of models)→ (motion sensing,only
valid for part of models) →10°C heating function(this function only works in the heating mode, only valid for part of
models) → health airow up (Only valid for part of models) → health airow down (Only valid for part of models)
(3) The function is valid only when the angle of Up/Down swing can be set.
(4) Health airflow up/down function cannot be set at the same time. When the latter is set, the former will be
automatically canceled.
(5) After the function is set, the angle of Up/Down or Left/Right swing can be normally adjusted in the main
interface. Press the SET key to enter function circulation. When Up/Down swing icon ashes, press SET key, and
then swing angle position 1 will ash. Press Up/Down key to adjust the angle. When the adjusted swing angle is
executed, the health airow up/down is canceled simultaneously.
(1) Press key to enter function setting, press to the sleeping icon “ ” and it will ash, the sleeping time
will display by the which is on the top-right corner. Press Time key to enter sleeping time setting. “OFF” and
sleeping icon are ashing. Press to adjust the sleeping time by 0.5h once, the range of sleeping time is from 0.5h
to 72h. After the adjustment, press key again to conrm the operation. “OFF” and sleeping icons are statically
displayed.
(2) During sleeping icon is ashing, pressing key instead of key, the wired controller will take the converse
operation of previous sleeping state. If there is sleeping set, cancel it; if not, come into the setting operation.
(3) If power off is executed during sleeping, the sleeping function is cancelled at the same time; there is no display
when powered on again. It needs to be reset if any requirement.
(4) In sleeping set or modication state, if there is no operation in 10 seconds, it will keep previous state, and the
setting or modication is invalid this time.
(5) Under sleeping and timer setting state, it will display setting time respectively; when setting simultaneously, it
will display the prior executed time. When timer off is executed rst, sleeping function will be cancelled and when
sleeping is executed rst, then timer off function will be operated after that.
(6) Under function setting state, it will exit function setting state by pressing or key.
(7) Sleeping time and timer on should not be set at the same time.
(8) When setting sleeping function, press ON/OFF key to quit sleeping set and turn off unit.

14
(1) Press key to enter function setting, press to the heat reclaim ventilation icon “ ” and it will ash, press
key again to conrm the operation. The above operation can cancel the heat reclaim ventilation function if heat
reclaim ventilation function has been set.
(2) After you set heat reclaim ventilation function, change mode of wired controller, heat reclaim ventilation function
is kept and heat reclaim ventilation function will be memorized when non-volatile memory valid.
(1) If the current temperature is displayed in Celsius, set temp. should be adjusted to 30°C in each mode(when
energy saving function is set currently, the heating mode will be the highest limit value of the energy saving
function). Then press key for 15s to switch to Fahrenheit, the interface will display 86°F (when energy saving
function is set, its highest limit value of Fahrenheit will be displayed).
(2) If the current temp. is displayed in Fahrenheit,set temp. should be adjusted to 60°F in each mode(when energy
saving function is set currently, the cooling/dry mode will be the lowest limit value of the energy saving function).
Then press key for 15s to switch to Celsius, the interface will display 16°C (when energy saving function is set,
its lowest limit value of Celsius will be displayed).
Heat Reclaim Ventilation Function
Switch between Fahrenheit and Celsius
Energy Saving (reserved)
Filter Cleaning
10°C Heating Function ( Only valid for part of models )
Four-way cassette-Function (Only valid for part of models )
(1) Press key to enter function setting, then press to choose energy saving, press key again to conrm
the operation and display energy saving icon . If energy saving function has been set, the above operation will
cancel it.
(2)The energy saving default parameter are 23°C (74°F) (the lowest temp. limit of cooling and dry mode) and 26°C
(78°F) (the highest temp. limit of heating mode). The temp. adjusting range is 23°C-30°C (74°F-80°F) in cooling and
dry mode, the temp. adjusting range is 16°C-26°C (60°F-78°F) in heating mode. If energy saving function is set, the
indoor units will run at the default temperature.
Note: Fresh Air unit has no energy saving function.
When lter cleaning icon is displayed, the icon will display in function sequence. If lter cleaning icon is ashing,
press key to clear it.
(1) Only in heating mode, this function is valid in function circulation.
(2) For the four-way cassette model, press the SET key for 5s to enter the function circulation. When it switches to
the 10°C heating function, 10°C will ash in the temp. display area. Press the SET key to conrm, and 10°C will be
statically displayed.
(1) When it is powered on for the rst time, four-way cassette icon and Up/Down swing will be displayed. The
number1,2,3,4 next to the swing referred to different wind deectors will be displayed(if the wind deector is on the
position 1, the Up/Down swing will stay the angle set by the wind deector position 1.Meanwhile the number 1 next
to the Up/Down swing will be displayed. If it is selected as four sides controlled together, the number 1, 2, 3 ,4 next
to the Up/Down swing will be displayed at the same time). Set key now can only switch among four wind deectors.
Use Up/Down key to set the angle of the current wind deector.
(2) The circulation of the wind deector:
four-way cassette deectors controlled together→four-way cassette deector 1→four-way cassette deector
2→four-way cassette deector 3→four-way cassette deector 4→four-way cassette deectors controlled together.
(3) If it’s not the rst time to enter it, press Set key, the wind deector set last time will ash. Meanwhile the angle of
this deector set last time will be displayed statically, and the number of the wind deectors next to Up/Down swing
will be statically displayed.

15
Motion sensing (Only valid for part of models )
Motion Setting (Only valid for part of models )
Malfunction Display
Child Lock
(1) Press Set key for 5s to enter the function circulation, and then press Up/Down key to switch to (the second 8
of 88.8 in the temp. display area displaying A) → (the second 8 of 88.8 in the temp. display area displaying B) →
(motion sensing).
(2) After motion sensing A is set, the character A will disappear with room temp./set temp. displaying. The icon of
motion sensing will display statically.
•After motion sensing B is set, the character B will disappear, with room temp./set temp. displayed. The icon of
motion sensing will ash in the xed frequency.
•After motion sensing is set, the icon of motion sensing will be displayed for 2s and disappear for another 2s to
have respiratory effect.
(1) In off and non screen saving state, press Mode key for 5s, it will display 8 segment on the top-left corner of
current mode circulation, default value being 0. Press Up/Down key to shift between 0, 1, 2, 3, then press Set key
to conrm value. It will follow the altered mode circulation after turning on the unit again.
Corresponding mode of different value.
0-------------[Intelligent] [Heating] [Dry] [Cooling] [Fan] 1-------------[Heating] [Dry] [Cooling] [Fan]
2-------------[Dry] [Cooling] [Fan]
3-------------[Heating] [Dry] [Cooling] [Fan]
(2) The intersection of mode circulation set by wired controller and indoor unit is valid.
(3) Fresh Air unit can execute mode setting, it will execute the intersection with three modes of Fresh Air unit (cooling/
heating/fan mode)
(4) The mode of indoor units can be inquired /changed by the advanced setting function after the wired controller is
powered on, Only valid for part of models.
(5) Set as follows (Only valid for part of models):
Press Set key and Up key for 5s to enter the advanced setting state, with the function A in temp. display area
displayed statically. Press Fan key to switch to function B. The function code 01 displayed in the clock display area
will ash. The specic information in the timing display area is statically displayed, it can be changed in the range of
00-03 by Up/Down key. At this time press Set key to conrm, and the function code 01 in clock display area stays
static, the specic information in the timing display area ashes, meaning it can be changed currently. Press Up/
Down key to change the content and Set key to conrm.
(1) Under no screen saving state, press key for 10 seconds to check all indoor units malfunction in the group.
Unit No. is displayed behind the top-left colon; current malfunction is displayed before top-right colon and historical
malfunction is behind colon.
(2) Unit No. is displayed in decimal and malfunction is displayed in hexadecimal.
(3) All hexadecimal numbers of malfunction are in capital. But b and d is in small capital in order not to mix with 8.
(4) If there is no current malfunction, “--” is displayed before the right colon; if there is no historical malfunction, “--”
is displayed behind the right colon.
(5) Press key to quit malfunction check state. The clock information and timer information are displayed.
(6) Malfunction records clearance: Keep pressing key for 10 seconds, malfunction is displayed. Then press
key again for 5 seconds to clear current and historical malfunction of all the units.
(7) Press to choose unit No..
(1) Child lock function can be used to prevent false operation. All of keys are locked after pressing and
together for 5 seconds. child lock icon will display on the interface. All of settings will exit and keep the previous
state. All of keys are invalid including "ON/OFF".
(2) The screen will unlock after pressing and together for 5 seconds, child lock icon will disappear and all
keys are available.
Note:
When controlling Fresh Air unit, the controller main interface will not display Up/Down key in normal state. When in
child lock setting, press Time key rst to display Up/Down key at the main interface, and then press Set and Down
key together for 5 seconds to enter child lock setting. After setting child lock, Up/Down key will keep displaying for
the convenience of cancellation of child lock.

16
(1) Keep pressing for 5 seconds (if it is the four-way cassette model, the time is 10 seconds) to enter parameter
inquiry. Unit No. is displayed on 88 area of clock while data type is displayed on 88 area of timer. Unit No. is
displayed on the rst two "88" elds of clock while data type is displayed on the rst two "88" elds of timer. The
data type includes A, b, C, d, E and F. The current data is displayed behind date type. For example, ambient temp.
of 00 unit is 16 degree, then “00 A 16” is displayed. Press to choose different type of data from A, b, C, d, E
and F.
Data Type meaning System
A Indoor sensor Tai temp. Actual value, decimal sys.
b Indoor sensor Tc1 temp. Actual value, decimal sys.
C Indoor sensor Tc2 temp. Actual value, decimal sys.
d Indoor unit PMV opening/2 Actual value, decimal sys.
E Indoor unit address Actual value, hexadecimal sys.
F Indoor unit central address Actual value, hexadecimal sys.
(2) In parameter inquiry state, press key to change the unit No. address in the group.
Parameter Inquiry
Unit No. Setting
Static Pressure Grade Inquiry and Adjustment Function
Communication with Central Controller
(1) Entering: Press key for 10 seconds (if it is the four-way cassette model, the time is 15 seconds) to enter unit
No. setting/ inquiring.
(2) Setting is available when the communication address between indoor and outdoor unit is ashing if the indoor
unit’s dip switch can set the address, then use to adjust within the range of 0-3F. If the indoor dip switch cannot
set the address, the communication address between indoor and outdoor unit is static, which can only be inquired.
(3) Wired controller’s address is displayed before the colon of clock on the top-left corner, ranging from 0 to 15 and
displayed in decimal system.
(4) The communication address between indoor and outdoor unit is displayed on the top-left corner. The default
value is the current unit’s address, selecting other indoor units by the .
(5) Central address is displayed on top-right corner which cannot be edited.
(6) Press key to conrm and exit the setting after changing the communication address of indoor unit. If press
other keys or no operation in 10 seconds, it will automatically exit and keep previous setting. If press or
key, exit and the current setting is invalid. If press “ON/OFF”, turn on/off the unit directly and the current setting is
invalid.
(1) In the state of ON and non screen saving state, press Fan + Set keys for 5s to enter static pressure grade
adjustment state with static pressure icon ashing and current static pressure grade statically displaying. Press
key to change static pressure grade, then press Set key to conrm.
(2) The unit No. will display by two 8 segments after colon on the top-left corner, and static pressure grade will
display by two 8 segments after colon on the top-right corner. Press Time key to shift unit No..
(3) Unit No. will show decimally from 00-15. Static pressure will be shown decimally from 01-04.
(4) In query and adjustment state, if there is no screen saving, press ON/OFF key to quit current state and turning
on/off unit, with changed values not being saved.
(5) Static pressure is the inquired value with non-volatile memory invalid.
(6)The number about the indoor units’ static pressure grade and the static pressure grade executed by the indoor
units can be queried/ changed by the wired controller(Only valid for part of models).
(7) The number about the static pressure grade and the static pressure grade can also be queried/ changed by
advanced setting interface(Only valid for part of models).
(1) The controller displays to show central control mode after receiving central control signal from indoor unit;
(2) When statically displays, all keys except “ON/OFF” of wired controller are invalid. central icon will disappear if
no central control signal from indoor unit.
(3) When receiving locking signal from indoor unit, statically display, all keys are invalid.
(4) In central or lock state, screen saving is valid; press any key to wake up screen.
(5) In central or lock state, malfunction inquiry, indoor unit parameter inquiry and child lock are valid.

17
Energy Saving Parameter Setting
Non-volatile Memory
Communication Malfunction of Wired Controller
Sensor Malfunction
Temp. Compensation Setting
Forced Cooling/Heating
(1) Under cooling mode 30°C (86°F), keep pressing key for 5 seconds to set energy saving parameter in
cooling mode. This cooling energy saving parameter is ashing behind top-left colon. The default value is 23°C
(74°F). This lowest target cooling temperature can be adjusted by . After setting, press key to conrm and
exit.
(2) Under heating mode 16°C (60°F), keep pressing key for 5 seconds to set energy saving parameter in
heating mode. This heating energy saving parameter is ashing behind top-right colon. The default value is 26°C
(78°F). This highest target heating temperature can be adjusted by . After setting, press key to conrm
and exit.
(3) Energy saving parameter will be valid after energy saving icon displays.
(1) Set valid or invalid non- volatile memory through dip switch Sw4.
(2) Info memorized: Mode, Fan Speed, Temp. Setting, Swing State, Heat Reclaim Ventilation function.
(3) If timer or sleeping is set, it will be in OFF state after electried again; it will memorize all the state before power
failure except ON/OFF state.
(4) For easy maintenance, no matter non-volatile memory is valid or invalid, malfunction record will be remembered.
If there is no communication between wired controller and indoor unit for 4 minutes, it will display error code “07”
when checking malfunction.
If the dip switch is set to collect ambient Temp. from wired controller and the sensor can’t work normally, it will
display error code “01” when checking malfunction.
(1) In OFF state, keep pressing key for 5 seconds, the current temp. compensation value is displayed on the
top-right of the screen and ashes. “00” is the default value.
(2) When in Celsius system, ambient compensation value is -04~+04°C, while in Fahrenheit system, ambient
compensation value being -07~+07°F. The temp. compensation value can be adjusted by pressing .
(3) After adjustment, press key to conrm the setting.
(4) The compensation value is used for ambient temp..
(5) The compensation value is valid only in the state of collecting ambient temp. of wired controller.
(1) Powered off in cooling mode, keep pressing “ON/OFF” key for 10 seconds, it will enter into the forced cooling
function, and the cooling mode icon will be displayed on the interface. “LL” is ashing in the temp. area at the same
time. Press “ON/OFF” key to power off and exit forced cooling.
(2) Powered off in heating mode, keep pressing “ON/OFF” key for 10 seconds, it will enter into the forced heating
function, and the heating mode icon will be displayed on the interface, “HH” is ashing in the temp. area at the
same time. Press “ON/OFF” key to power off and exit forced heating.

18
B
A
A
B
B
C
C
Indoor 1
A
A A A A A
A
B B B B B
B
C C C C C
C
Indoor 1 Indoor 2 Indoor N Indoor 15 Indoor 16
Control wiring of wire
controller, polar. Wire controller
Wire controllerWire controllerWire controller
Wire controller
Wire controller Wire controller
Wire controller
Wire controller
Wire controller
Wire controller
(master unit)
A
A A
B
B B
C
C C
Polar
wire
Polar
wire Polar
wire
Indoor 1
C
Wiring Connections of Wire Controller
Communication wiring
There are three methods to connect wired controller with the indoor units
A. One wired controller can control max. up to 16 sets of indoor units, and 3 pieces of polar wire must connect the
wire controller and the master unit (the indoor unit connected with wire controller directly), the others DC indoor unit
connect with the master unit through 2 pieces of polar wire and AC indoor unit connect with the master unit through
3 pieces of polar wire.
B. One wire controller controls one indoor unit, and the indoor unit connects with the wire controller through 3
pieces of polar wire.
C. Two wired controllers control one indoor unit. The wired controller connected with indoor unit is called master
one, the other is called slave one. Master wired controller and indoor unit; master and slave wire controllers are all
connected through 3 pieces of polar wire.
Notice: For wired controller connection, please do follow the corresponding indoor unit installation manual's
instruction.
•Wired Controller Wiring Instruction
Communication wiring length (m) Dimensions of wiring
≤ 250m 0.75mm2x3-core shielded wire
*One side of the shielded sheet of communication wire must be earthed.
This manual suits for next models
1