HEINRICH DVA8-500 User manual

DVA8-500
DVA8-500RT
DVA8-500RM
DVA8-500SF
HEINRICH
Technology beyond imagination
INSTALLATION AND OPERATION
MANUAL

HEINRICH
About the Manual..............................................................................................................2
> System Overview................................................................................................................................2
> Features..................................................................................................................................................2
> System Capacity..................................................................................................................................2
> Introduction.........................................................................................................................................2
1. Controller and Slave Controller DVA8-500/DVA8-500RT....................................3
1.1. Front Panel.............................................................................................................................................. 3-6
1.2. Rear Panel....................................................................................................................................................6
1.3. Technical Specications........................................................................................................................11
Electrical Specications................................................................................................................................11
Mechanical Specications...........................................................................................................................11
Environmental requirement.......................................................................................................................11
2. Remote Paging Microphone DVA8-500RM........................................................12
2.1. Front Panel and Rear Panel...........................................................................................................12-13
2.2 Technical Specications........................................................................................................................14
Electrical Specications................................................................................................................................14
Mechanical Specications...........................................................................................................................14
Environmental requirement.......................................................................................................................14
3. System Connection Diagram...............................................................................15
4. Operation guidance ............................................................................................15
4.1. Manual Music Broadcast......................................................................................................................15
4.2.Manual Broadcast Emergency Message.........................................................................................16
4.3. Auto Broadcast Emergency Message.............................................................................................16
4.4. Sosftware DVA8-500SF Setting..........................................................................................................16
4.5. Emergency Fireman Microphone Operation...............................................................................16
4.6. Remote Paging Microphone DVA8-500RM Operation.......................................................16-17
5. Software DVA8-500SFT Introduction.........................................................................18
5.1. Icon Introduction...................................................................................................................................18
5.2. Initialization..............................................................................................................................................18
5.2.1.Computer Conguration...................................................................................................................18
5.2.2.Installation..............................................................................................................................................19
5.2.3.Uninstall...................................................................................................................................................19
5.2.4.Operation................................................................................................................................................20
5.2.4.1. Software Log In................................................................................................................................20
5.2.4.2. Control Interface Introduction...................................................................................................20
5. 2.4.2.1. Menu Bar & Tool Instruction....................................................................................................21
5.2.4.3. Introduction of Current Operating Interface.........................................................................21
5.2.4.3.1.Zone Control...................................................................................................................................22
5.2.4.3.2. State............................................................................................................................................23-24
5.2.4.3.3. System Conguration.................................................................................................................25
5.2.4.3.3.1. Setting Check.............................................................................................................................25
5.2.4.3.3.2. Fire Alarm Setting..............................................................................................................26-27
5.2.4.3.3.3. Zone & Group Conguration...............................................................................................28
5.2.4.3.3.4. Priority conguration.............................................................................................................29
5.2.4.3.4. Event Inquiry.................................................................................................................................30
5.2.4.3.5. Others Setting...............................................................................................................................31
6. Attention...............................................................................................................................................31-32

HEINRICH
About the Manual
1.Purpose: Provide installation, conguration and operation DVA8- 500 system information.
2.Target reader: Professional technician after training.
3.Terminology
Controller - DVA8-500;
Extension - DVA8-500RT;
Operation Mic - DVA8-500RM;
Software - DVA8-500SFT;
The software of this system will be continuously upgraded, but backward compatibility. Please
note the company's website real-time information.
Syatem Overview
DVA8-500 system is both PA system and voice alarm system. The system Integrated with
requirements of EN60849、BS5839/8 and EN54-16 evacuate standard. Usually used in must
small system which need voice evacuation or system that only need one call channel.
Features
Meet the requirements of GB16806-2006 standard and European voice alarm control and
Indicating equipment standards. Automatic fault diagnosis system, data backup Line redun-
dancy and record fault state<=5000 Safe, stable and reliable. System compatible with three
wire system and four wire system standard wiring. Emergency message pre-recorded or
customized of dierent languages. System programming to the zone,Support manual,
automatic, district, grouping operation. Support Visual man-machine interface, control
system, and support several windows man-machine interface, control system, after congu-
ration system can o-line working;

HEINRICH
Important Notice for System Operation
DVA8-500/DVA8-500RT(Host/ extension host)DVA8-500 is The core of voice alarm system
DVA8,built with 240W/350W/500W digital amplier, enable to manual or auto broadcast
the emergency message, also reman microphone evacuation is also possible under emer-
gency, system capacity up to 120 zones with paging and background music functions, moni-
toring includes amplier failure, speaker line failure, emergency message and emergency
microphone supervision.
> Emergency message format of *.wav.
> SD card message number shall be less than 255 in the le root of “evac_message/” &
“alert_message/” & “prompt/”.
> Make sure the software standby amplier conguration is same as real amplier
wiring, otherwise, the host DVA6-500 will not auto standby to backup amplier without soft-
ware correct conguration.
> 8 zone speaker outputs, each zone max power output is 500W, total 8 zone power
output max is 500W.
> With 8 external microphone or line inputs for analog microphone use or external
audio sources input.
> With control input and control output to inter-work with third party system.
> With 3000 events history record includes power module, reman mic, emergency
message, amplier & speaker line.
> System capacity of 32 units remote paging microphone up to 600 meters through
CAT5 or CAT6 straight cable.
> System support redundancy cable wiring among remote paging microphone, host
and extension host within 600 meters.
1.1. DVA8-500 & DVA8-500RT Front Panel
1:- AC Power Indicator.
Green----means currently host AC supply normal; Yellow----means currently host AC supply
failed.
2:- DV24V Indicator.
19
20
21
7 9
22
8 10 11
23 24
12 1413 15 16 17 18
3
4
5
6
1
2

HEINRICH
Green----means normal; extinguish----means no software conguration; Yellow----means
failed.
3:- Communication Indicator among Host and Extension.
Yellow----means no logical or physical connection; extinguish----means no logical or physical
connection between DVA8-500SF with host; Green----means currently device connection is
normal.
4:- Fault Indicator.
O means system working well unless the dipswitch PIN of all supervision function is disable
on rear panel; yellow means system fault, otherwise press “ACK/REST” to restore the system.
5:- Emergency Microphone Indicator.
Yellow----means microphone lost or faulty; Green----means working well; extin-
guish----means microphone is normal but it is not working.
6:- Indication Test Button.
Press the button to light on the LED indicators of all equipments include host, extension and
paging microphone to test the indication working well.
7:- Emergency Button.
Red ash—emergency mode; extinguish--normal mode.
Making Emergency Broadcast: a) Emergency broadcast will be activated by manual press the
button and red light ashing. b) Auto emergency broadcast will be activated by the trigger
inputs on the rear panel of host and extension unit and red light ashing.
Reset the Emergency Mode: a) Press the “ACK/Reset” button on the front panel to exist the
emergency mode to terminate the emergency broadcast and terminate the zone output. b)
Input a reset signal to the emergency control input terminal on the rear panel of the
DVA6-500 which has been assigned a reset function. These events history could be recorded
and inquired in the software history record.
8:- ACK/RESET Button
a). If the system various modules work normal or abnormal system module diagnosis but
press the button when the indicator "FAULT" light is not ashing, equipment do not do any
processing;
b). If the system module in the diagnosis of abnormal, "FAULT" of FAULT indicator light ash-
ing, press some button, "FAULT" stopped lighting from blinking, blinking indicating its
disabled state ,Buzzer to stop till To the new module detects abnormal after heavy shine
again "FAULT" LED lamp and start the buzzer hint user;
c). When the current partition has output, press the build close the current audio output,
quick exit and quit play;
9/10:- DVA8 & Alert Emergency Message Button & Indicator.
Green—“DVA8 MSG/ALERT MSG”Voice is in broadcast information;Yellow—“DVA8

HEINRICH
MSG/ALERT MSG” Lose voice information or loss SD card;Extinguish—— “DVA8 MSG/ALERT
MSG” Normal.
Note: 1."DVA8 voice information" refers to the DVA8 voice ALERT and voice;2. If you need to
manually play DVA8 voice messages,Need to enter the emergency mode, Then press the
voice messages button; 3. System default “DVA8” Voice priority is higher than "ALERT". Can
change the priority through the DVA8 - 500 SFT conguration..If not special application
requirements, please do not change it.
11:- Line Input Selector Output switch selective switch.
Mainly used to select the external line input to this host or extension.
Note:The choice of the current user can see through the DVA8 - 500 SFT interface,To
change the dierent audio output,Only through use to choose from the panel.
12:- All Zone Selector.
To select all six zone outputs open or close at the same time.
13:- Zone Fault Indicator.
Yellow-The current partition A and B or A or B speaker impedance change, may be open or
short circuit. Extinguish-The current speaker zone loop impedance changes within the
impedance of the speaker when it was pre-set.
Note:When the host or extension host access system according to the project wiring work
needs a resistance to proofread before obtaining the loop impedance value of the current
speaker, please follow below steps:
Unplug the host back row ID switch. 7,Until hear buzzer sing alternately or see panel lights
ashing after "FAULT" then, Put the 7th ID switch it on. When the speaker circuit impedance
change more than the current host or extend the host for the impedance value plus or minus
10% ~ 10%Will record the current changes and inform the user in the form of light. Zone
detection sensitivity is more than 20W
14:- Zone Emergency Microphone or Remote Microphone Indicator.
When paging, can manually close the zones where no need paging or add new zones.
15:- Zone Emergency Broadcast Indicator.
When DVA6 and alert emergency broadcast is working, the indicator will be light on.
16:- Zone Background Music Indicator.
When background music broadcast is working, the indicator will be light on.
Note:Manual broadcast voice messages need choose audio rst, then, choose output
zone, For example, if you want output line 3 in 3rd zone, you can choose line 3 audio then
choose 3rd zone. You also can choose 3rd zone, then, choose line 3. Two ways are the same,
normally, we choose zone rstly, then choose audio. In this way, each zone will output audio
at the same time, We also can control dierent zones from the DVA8- 500 SFT operation.
17:- Zone Selector.
To select individual six zone output open or close.

2 3 41 5 6 7 8 9
191816 1713
11 12 14 15
10
HEINRICH
18:- Zone Output Attenuator.
Increase or decrease the individual zone speaker output loudness at 6 levels and max control
of -15dB.
19:- Emergency Microphone Input.
Input for the emergency microphone or reman microphone of priority.
20:- Monitor Speaker Attenuator.
Increase or decrease the built-in monitor speaker loudness.
21:- Emergency Microphone Gain Control.
It is used to adjust the emergency microphone input sensitivity.
22:- Treble Control.
Increase or decrease the overall treble output.
23:- Bass Control.
Increase or decrease the overall bass output.
24:- Master Volume Control.
Increase or decrease the overall master volume output.
1.2. DVA8-500 & DVA8-500RT Rear Panel

HEINRICH
1:- 24V DC Power Input.
24V DC input for sealed lead-acid battery, UPS or equivalent product;
Note:-
1. Use EN54-4 certicated power supply when EN standard required.
2. Do make sure the 24V DC could meet the minimum working current of the host. For exam-
ple, full loading of DVA8-500 at 500W, the lead-acid battery shall supply the current higher
than 27A, battery capacity higher than 27Ah and working time shall be full load-
ing*27Ah*1.2 hours.
2:- Six Zone 24V Relay Outputs.
For 4 wired volume control, each zone rated output current is 0.2A, max total six zone
outputs less than 28W.
3:- Six A/B Speaker Zone Outputs.
Direct connection of 100V loudspeakers or 3 wire volume control. Output voltage is 0-100V.
Speaker output could be wired one output or both A/B output, A/B output could be backup
once one speaker zone disconnection or faulty. Each individual zone max outputs is 500W in
the condition of the total six zone output max less than 500W.
Note:-
>At least one time speaker zone modeling is needed after speaker wiring.
>Some zone without speaker leave it vacant is OK.
>DVA8-500SF can be pre-set some speaker zone not allowed output.

Star connection
Closed or loop connection mode
HEINRICH
4:- 8 Program Control Outputs.
These outputs usually shall be keep open, which could be programmed in the software to
activate it or terminate it auto or manually.
5:- 8 Program Control Inputs.
These inputs usually shall be keep open, which could be programmed in the software to
activate it or terminate it auto or manually.
6:- LAN Input for PC Software.
It is mainly used to connect to DVA8-500SF for setting, program and manual operation.
Note:-
1) Default IP address: 192.168.1.168, Communication port number: 16888.
2) Reset the IP address to default by enable & disable once time the dipswitch 6th PIN
on the rear panel of host.
3) If you dislike the default IP address, please up the 5th dipswitch to open DHCP func-
tion. Make sure your network router opened up the DHCP function.
4) Support PC software directly connection to DVA8-500, automatic identify cross and
straight cable. All communication cable shall be meet TIE/EIA-568B standards including
connection to extension and remote paging microphone.
7:- Remote Paging Microphone Input.
Use straight cable to connect the remote paging microphone DVA8-500RM to the host,
system capacity of 32 units and communication distance is up to 600 meters. Support micro-
phone loop connection or star connection as below picture, the system software will auto
distinguish dierent kinds of cable connection.
8:- Extension controller DVA8-500RT Input.
Use straight cable to cable to connect the extension controller DVA8-500RT to the host,
system capacity of 19 units extension and communication distance is up to 600 meters. Sup-
port microphone loop connection or star connection as above remote paging microphone
pictures, the system software will auto distinguish dierent kinds of cable connection.

HEINRICH
9:- Emergency Message Memory Card.
The emergency message memory card is real time monitored, tested memory capacity of
32G, never plug out this card during work, otherwise the event record and program will be
lost. The root of emergency message as below picture, there is each one Alert and DVA8
default messages, edit, add or delete or replace these messages are possible done by profes-
sional technician, these messages will be real time supervised. “Log” le is log in event
record, which could be inquired or download in software DVA8-500SF. “Prompt” means
chime before announcement, so customized chime could be replaced the default one in
DVA8-500RM, this message is not real time monitored, only will be reviewed once after
power on, so no chime or le lost will be not warned as fault. Max message number is 255.
10:- Standby or Extension BGM Amplier 100V Input.
The standby amplier will be auto switched in service once the main amplier have faulty,
the standby amplier power shall be same watts or higher watts than the main amplier. The
standby amplier could be use as music amplier in normal mode, it will auto switched to
standby mode in case of main amplier failed.
11:- Standby or Extension BGM Amplier Balanced Line Output.
This balanced output will be connected to the standby amplier balanced line input.
12:- Fault Output.
Any fault of the system, the output will be open circuit to send contact to third party system
for inter-communication, no fault, the circuit will be closed.
13:- Emergency Output.
In case of DVA8 emergency broadcast, the output will be open circuit to send contact to
third party system for inter-communication, no fault, the circuit will be closed.
14:- Remote Reset Input.
In case of emergency broadcast, a 0.5S or higher relay short circuit input which will be
acknowledged as reset action, this input usually is from CIE equipment for remote control.
This input will be ignored during normal mode.

HEINRICH
15:- Function Conguration Dipswitch.
Upward means enable and downward means disable. 1st PIN means all functions supervi-
sion. 2nd PIN means 24V DC input. 3rd PIN enable means contact trigger and disable means
signal level trigger. 4th PIN means with standby amplier. 5th PIN means dynamic IP address
allocation or DHCP. 6th PIN means host default IP address reset through o-on-o action.
7th PIN means speaker zone impedance calibration in the condition of zone output is termi-
nated. 8th PIN means speaker line supervision function.
16:- External Two Microphone or Balanced Line Inputs 5-6.
17:- Gain Control.
These gain control is used to increase or decrease the input sensitivity for MIC/Line inputs
5-6.
18:- Line Inputs1-4.
These four line inputs used to input external audio sources players for background music
system use.
19:- Host REC Output.
This REC output is mixed output for external voice recorder or other recording equipment.
20:- Extension Controller Function
Congurable Dipswitch. Upward means enable and downward means disable. 1st PIN to 5th
PIN is used to set up the extension controller ID number. 6th PIN means 24V DC input. 7th
PIN means standby amplier. 8th PIN means speaker line supervision function.

HEINRICH
1.1. Technical Specications
Model
DVA8-500
DVA8-500RT
Description
Host
Extension Controller
AC Electrical Part
Power Supply
AC220V-250V, 50/60Hz
Power Consumption
650W
Max Current
<3A
Fuse
250V/5A, low speed type
DC Electrical Part
Power Supply
24V DC, 20V-27.5V
Max Current
<27A
Emergency
Microphone
Sensitivity
5mV
Impedance
600Ω
Line Input 1-6
THD
<1%, at rated power output, 1kHz
Sensitivity
775mV
Impedance
10kΩ
S/N Ratio
>70dB
Control Input &
Output
Fault Output
Closed circuit, no voltage
DVA6 State Output
Closed circuit, no voltage
DVA6 Reset Input
Closed circuit, no voltage, T>0.5s
8 Program Control
Output
Closed circuit, no voltage
8 Program Control
Input
Way-1: Closed circuit, no voltage
Way-2: Level input and max 3.3V
Emergency
Message
Format
WAV
Memory Card
SD memory card
Capacity
32G
Message No.
255 Max
Period
10 years
Log Event
Format
HEX
Storage Way
Nand Flash
Event No.
1000
Period
10 years
Working
Environment
Operation Temp
+5℃~ +40℃
Storage Temp
-20℃~ +70℃
Relative Humidity
< 95%
Mechanical Spec
Dimension
484(W)x132(H)x449(D)mm (3U)
Net Weight
11.5kg
Rack Mount
19” rack mount type
Finish
Aluminum plate and metal case in black

Remote Paging Microphone —DVA8-500RM
Description
DVA8-500RM is used to remote zone paging over the DVA8 system, support 12 zones and 12
groups programmable control. Support the redundant cable wiring, system capacity of 32
units and communication distance up to 600 meters, the paging microphone will be real
time monitored by the system.
Feature
Easy intuitive and user friendly operation paging console
Congurable PPT paging mode and normal paging mode
With 9 levels of congurable priority
Support 24V phantom power supply, no need extra power adapter
System capacity of 32 units paging microphone
Balanced signal transmission ensure distance up to 600 meters
Support the redundant loop cable wiring for microphone supervision
Front Panel and Rear Panel:
HEINRICH
4
6
5
1
3
2
97 8 10 11
HEINRICH

1:- Power Indicator.
The indicator is used to indicate power on/o or busy. Green-phantom power supply
normal. Red ash-busy. Extinguish-No power supply. Note: Red ash always to check the ID
conguration whether is correct. Green indicator and button no response, please check the
CAT6 cable connection is well. All indicator ashing in green, please check the paging micro-
phone conguration in the software, after that please reset the system.
2:- Microphone Input.
The microphone input is balanced input, after select the zone and press the call button, the
red round indicator of this gooseneck microphone light on means ready for announcement.
3:- Zone Indicators.
Light on means working. Flash means zone has been selected. Extinguish means no work-
ing.
4:- Zone Selectors.
There are 12 zone selectors whether been used to select individual zone or program group.
In case of no paging, press the button when indicator extinguished or illuminated means
zone selection. Press the zone button under paging means zone change either to terminate
the zone paging or add the zone paging.
5:- All Zone Selector.
Select or deselect all zones and the indicator will be illuminated or extinguished accordingly.
Button program to include some zones into one groups shall be congured in the software,
thus this button is only used to make group paging, individual zone paging is disabled. One
button is only been used whether individual zone or one group paging, could be not used of
both mode at the same time.
6:- Call Button.
Press the button after zone selection to start the paging. Press the button to terminate the
paging in case of announcement. Under PPT paging mode, keep pressing this button to
speak, release the button to terminate the announcement.
7:- Power Switch.
The 24V phantom power from the host DVA8-500 will direct power the paging microphone,
so please ensure the connection well between the paging microphone and the host then to
switch on the power.
8:- Link Connector.
One port used to communicate with the host and another is used to cascade the next
remote paging microphone.
9:- Microphone Output Gain Control.
Increase or decrease the gain for the microphone output.
10:- Line input.
This input will be mixed output with the gooseneck microphone.
HEINRICH

1.5 Tecchnical Specication
Model
DVA8
-
500 RM
Description
Remote Paging Microphone
System Capacity
32
units
Communication
Distance
600 met
ers
System
Connection
Star connection or loop redundancy connection
Zone Number
12
zones or
12
groups
Paging Mode
PPT & normal paging modes
Electrical Part
Phantom Power
Voltage
20V
-
27.5 V
Max Current
<
0.1 A
Power
Consumption
<
2.4 W
Line Input
Sensit ivity
775 mV
Impedance
10kΩ
S/N Ratio
>
70dB
Microphone Input
Sensitivity
5mV
Impedance
600 Ω
Working
Environment
Operation Temp
+
5℃~ + 40℃
Storage Temp
-
20℃~ + 70℃
Relative
Humidity
<
95%
Mechanical Part
Dimension
240 (W) x 140 (D) x 55(H) mm
Weight
1kg
Finish
Aluminum case in black
11:- ID Conguration Dipswitch.
Upward means enable and downward means disable. 1st to 5th PIN means ID of binary
system. 6th PIN upward means normal paging mode and downward means PPT paging
mode. 7th PIN upward means individual zone and downward means group, group could be
dened with multiple zones. 8th PIN is indication test, downward means start the LED indi-
cation test, all LED indicator will be from red-green-yellow then to normal state. Below is
example of remote paging mic ID from No 1 to No 4.
HEINRICH

Operation Guidance
Bill of Equipments:
Host, DVA8-500×1
Extension, DVA8-500RT×2
Remote Paging Microphone, DVA8-500RM×32
Software, DVA8-500SF×1
>Background Music Broadcast.
Input the audio sources or microphone to the line input1-6 on rear panel, select the line
input
HEINRICH
System Connection Example:
DVA8-500
DVA8-500SFT
DVA8-500RT x 01
DVA8-500RT x M
DPA500
DPA500
DPA500
NO TE :
1. Re dundant ca ble
2. CAT-5 STP /UTP ca ble
3. M : 1 ~ 1 9, N : 1 ~ 3 2
4. Trig ger i nputs mode table:
K1
K2
K3
MCU
dete ctio n
K1 K2 K3 St at us co nfi rm at io n
010
x 1 1
x 0 0
110
l og ic s t a tus
NO RM AL
T RI GGE R
SH OR T
OP E N
DVA8-500RM x 1
DVA8-500RM x 2
DVA8-500RM x N

HEINRICH
through the source selector on the front panel of host or extension unit, open the zone output with
corresponding BGM indicator means background music broa dcast. Note: The emergency message
and emergency microphone will be shared between host and extension unit, while the line inputs 1
-
6 are only for itself use.
Manual Emergency Broadcast.
Press the emergency button and illuminate in red, then select the zo ne and press the “DVA8 MSG” o
r
“Alert MSG” to make the manual emergency broadcast in the condition of message indicator light on
and zone DVA8 indicator light on. Press again the emergency button or remote reset input to
terminate the emergency broadcast.
Auto Emergency Broadcast.
From normal status, connect a timer or other external control equipment to the 8 program control
input terminals of the host or extension unit. The control input terminals receive a control input fro
m
the timer or allows an autom atic general announcement or emergency message to be broadcast. At
the same time, a control output will be send out to third party control system for inter -action. Ther
e
are two kinds of control inputs by short circuit contact or by level mode. Press again the emergenc
y
button or remote reset input to terminate the emergency broadcast.
Emergency Microphone Announcement.
Press the clip of emergency microphone to make emergency announcement to all zone any time, th
e
pre-announcement chime will be broadcast rst and the EMG microphone indicator will light on
means ready for emergency announcement, hang o the microphone to terminate the broadcast.
This emergency microphone circuit will be real time supervised.
General Announcement from Remote Paging Microphone.
Select the zone and illuminate the zone indicator, press the call button to make th e general
announcement with chime. Under PPT mode, the call button need to be kept pressing to make the
general announcement.
Background Music Broadcast from Software
A) Select the zone or group and choose the eective line input to make the general broadcast. The
zone or group displayed only after conguration, the software will auto distinguish the eective
line input. B) Move mouse to zone1 icon, and click the left to click the inverse button to control
the zone output status. Green means output and extinguish means terminate output.

HEINRICH

HEINRICH
DVA8 500SF System Software
Icon Introduction:
Save and s ynchronize to the DVA8 -500 host, each revision
should click on this OK button.
Save but not synchronized to the DVA8 -500host.
Give up the action.
Current zone is prohibited for operation.
Current Zone is working
Zone impedance vibration (open circuit or short circuit)
The current zone is normal, no broadcast.
The current zone is under emergency broadcast.
The current system modules normal
The current system module faulty
The current host normal
The current host system is faulty
Refresh
Upload
Save
Host
Host 01 means DVA8-500
Host 02 means extension unit 001

HEINRICH
Computer Conguration:
A
MD/Inter CPU 2.0G,Window XP SP3/Window 7/8/8.1/10.
I
nstallation.
D
ouble click the “setup.exe” orclick right mouse “Run as administrator” to install the software.
N
ote: Because the Operating System of Win7 and above had higher security system , please make sure
t
hat yo u are install the software as Administrator, if not it will make the software install or will have
t
rouble after it. Before that please check you have administration authority or not, and the method as
b
elow: Click on the icon “DVA8.exe”by right mouse to select the properties to run as administrator.
K
eep the PC and Host DVA8 -500 in the same network segment.
(
Host default IP address: 192.168.1.168, Sub Mask: 255.255.0.0, gateway: 192.168.1.1).
Downward the 5
th
PIN of conguration dipsw itch on the rear panel of host to have dynamic IP
address allocation or DHPC. Please refer to below pictures to help the DHCP once IP allocation is
rather slow.
This manual suits for next models
3
Table of contents
Popular Intercom System manuals by other brands

SSS Siedle
SSS Siedle HTC 811-0 Product information

LEGRAND
LEGRAND Easy Kit Connected installation manual

Batavia
Batavia 7062072 operating instructions

David Clark
David Clark 9800 Series installation manual

Viking Electronics
Viking Electronics E-10-IP-EWP quick start guide

ring
ring Pro Power installation manual