Henley Stoves Orion SEVERN Series Installation instructions

SEVERN
4kW / 5kW / 8kW
ECO
DESIGN
READY
TO BE INSTALLED BY A HETAS QUALIFIED INSTALLER
0.12%
CO
NOx
CxHy
0.10%
0.10
%
0.12
%
SPARE PARTS

2
Congratulations on the choice of
your New Henley-Orion Stove!
With the proper care & attention your Henley-Orion stove will give
you a lifetime of heat & comfort.
This manual contains instructions on how to install
and maintain your Henley-Orion Stove.
For both your comfort & safety please take the time to
read instructions carefully.
THIS APPLIANCE IS SUITABLE FOR WOOD
BURNING ONLY
DO NOT CONNECT THIS STOVE TO A CHIMNEY
FLUE SERVING ANOTHER APPLIANCE

3
Shutting Down Stove
Maintenance
Air Controls
Useful Information
Stove Finish (Paint)
Carbon Monoxide Alarm
Spare Parts
FAQ’s
Terms & Conditions
Stove Commissioning Checklist
Warranty Form
Technical Information
Installation Instructions
Flue Positions
Flue Options
Non-Combustible Materials
External Air
The Clean Air Act 1993
Combustible Materials
Recommended Fuels
Lighting The Stove
4
5
6
7
8
8
9
10
10
10
11
11
12
12
13
13
13
13
14
14
15
15
15
15
15
15
15
16
16
17
17
17
18
18
19
19
19
20
21
22
22
22
23
26
27

4
SEVERN 4kW
SEVERN 5kW
SEVERN 8kW
SEVERN 4kW 5kW 8kW
CONFIRMS TO : EN13240

5
4kW w/ LOGSTORE
Fixing the Logstore
5kW w/ LOGSTORE
8kW w/ LOGSTORE
Fixing the optional logstore
to your Stove,
Please nd included with
logstore the 4 xing bolts
required.
These must be secure for stove to
savely be used with logstore option.

6
Regulations
British Standard BS 8303, Code of Practice
for Installation of domestic heating
appliances burning mineral fuel
Domestic Heating
Fuel
Fireguard
Combustible Materials
Asbestos
Fire Cement
Extractor Fan
Ventilation:
Alterations
Chimney
Flue System
Serial Number
Manual Handling

7
Constructional Hearth Dimensions
for Solid Fuel Appliances & Open Fires
The Stove should be installed on:
A:
Non Combustible Hearth
surrounding Solid Fuel Appliance Ways of Providing Hearths

8
British Standards BS EN 15287-1:2007 -
design,installation and commissioning of
chimneys
HETAS
The following must be checked:

9
•
•
C
B
D
A
Horizontal
Measurement
Terminal
Flue
Vertical
Measurement
Insulation
150mm
Max
Seek specialist advice if installing
in a dwelling with a thatched roof
The datum for vertical measurement is the point of
discharge of the flue from either the point of disxcharge
ofn the flue or 150mm above insulation, whichever is
the lower.
Adjacent
Building
Adjacent
Building
These positions are defined by Document J of the Building Regulations.
C
B
D
A
Horizontal
Measurement
Terminal
Flue
Vertical
Measurement
Insulation
150mm
Max
Seek specialist advice if installing
in a dwelling with a thatched roof
The datum for vertical measurement is the point of
discharge of the flue from either the point of disxcharge
ofn the flue or 150mm above insulation, whichever is
the lower.
Adjacent
Building
Adjacent
Building
These positions are defined by Document J of the Building Regulations.
B
WARNING
Under no circumstances should
this appliance be connected to

10
Height Over Adjacent Building
Height Over Roof
Height Over Openings

11
WARNING
If Not using External Air Supply
Do not remove cover from back
WE RECOMMEND
Flexi-Liner is Used for
less than the diameter of the outlet of the
External
air
45o
600mm
minimum Access for
soot removal
External Air
Non Combustible
Reducer Plate
(Minimum
1.5mm Thick
Steel)

12
(b)
(a)
150mm on top50mm
(although we recommend 150mm) around
the sides50mm at the back
Severns External Air

13
rules
The Clean Air Act 1993 &
Smoke Control Areas
Severn 4kW & 5kW: 600mm Back
and 500mm to the sides,
Severn 8kW 750mm Back and
Wood Logs
Solid Fuel
200mm
100mm
Wood length
MAX 200mm, and 100mm in diameter

14
DO NOT BURN
bituminous coal,‘petro-coke’ or other
petroleum based fuels as this will
DO NOT leave the stove unattended if the
Note:
HENLEY-ORION RECOMMENDS THAT
WOOD LOGS BE PLACED VERTICALLY IN
THE SEVERN STOVE FOR BEST FLAME &
FUEL CONSUMPTION RESULTS
DO NOT load fuel above the tertiary air inlet

15
Directly after refueling it was
necessary to operate with the secondary air
fully open for a period 3 to 5 minutes before
closing to the desired setting
When refueling the appliance
it was necessary to leave the door ajar for a
period of 1 - 2 minutes in order to sustain
The stove will remain very
Petroleum coal fuels or household waste
must not be burnt in this appliance

16
NACS
stove rope

17
.
Bafe Plate Location
Bafe Plate example
Top of bafe
Rear of bafe
Stove Door Glass
Stove Glass
Glass Clips
Do not use appliance without the fuel
retainer in position.
Removing Fuel Retainer
(Front View)
1. LIFT UP
2. ROTATE

18
Henley Stoves appliances have air systems
the various air controls are located on your
Henley Stove
1)Primary Air
2) Secondary & Tertiary Air
DO NOT USE BARE HANDS
Stove Parts become very hot while the stove
is running so should not be touched with bare
DO NOT LEAVE AIR LEVERS / RODS
FULLY OPENED FOR LONG PERIODS.
We Recommend to Never Open More than 60%, As
Extended Use of Stove at More than
If fume emission does persist:
Stove Air Controls

19
Repainting Instructions:
USE ONLY GENUINE
ORION STOVES SPRAY PAINT
DO NOT OVER FIRE YOUR APPLIANCE
If a Chimney Fire Occurs :
• Call the Fire Service - Dial 999 or 112
• Immediately close all of the air inlets to
the appliance to reduce the air supply to
• Move items of furniture and combustibles
away from the stove to reduce the risk
• Ensure access to the loft space is
available
• Evacuate the property
Do not use the stove again until the stove,
chimney and connector have been inspected,
and any damage parts have been repaired or
This work should only be carried out by a
HETAS

20
1. 2.
3. 4.
Fixing Ext. Air kit to your Severn Stove
This manual suits for next models
3
Table of contents
Other Henley Stoves Wood Stove manuals
Popular Wood Stove manuals by other brands

HASE
HASE MERIDA - ANNEXE 246 Instructions for use

IKI
IKI Mini-IKI Instructions for installation and use

Parkray
Parkray Chevin Inset 5 MKII Instructions for installation/operation/maintenance/servicing

ECCO STOVE
ECCO STOVE E678 instruction manual

Firebelly
Firebelly 80KG quick start guide

Quadra-Fire
Quadra-Fire 31M-ACC-MBK owner's manual

Beyond
Beyond OSBURN 900 Installation and operation manual

Jøtul
Jøtul F 370 Installation and operating instructions

CFM
CFM WOOD STOVE owner's manual

Woodstock Soapstone
Woodstock Soapstone Survival Hybrid Installation

Quadra-Fire
Quadra-Fire 31M-ACC-MBK owner's manual

Alderlea
Alderlea T5 Installation & operation guide