Hewi ES5400 User manual

HEWI installation instruction
M1000_117_ES5400_EN_Vers-002.pdf M1000.117 Page 1of 7
HEWI P.O. Box 1260 D-34442 Bad Arolsen
HEWI compact-wallreader ES5400 in combination with sub-
finery cover ES5410
Product description / scope
The HEWI compact-wallreader ES5400 is defined for usage within the electronic locking
system ES5000 to control peripheral devices like electric door openers, electric locks, electric
door and gate drives, elevators and so on.
The usage for scopes apart from the usual requests for electronic locking systems has to be
authorized by HEWI in the doubt. The wallreader ES5400 cannot be used for security-critical
applications and must not be used in humid rooms or outside of buildings. Please use the
variations ES5401, ES5402 and ES5403 for those applications. For further informations
contact the HEWI Servicecenter locking systems, fon +49 5691 82-200. The usage in dusty
environment without further protections (for instance the mountage in dust protected casings)
is not allowed.
Warning
a) Security against manipulation (unauthorized access)
Attention: If using the ES5400 manipulation in access-direction is possible, that means that
by removing the wallreader the connection cables can be used for operating the peripheral
device. For security-relevant applications the reader-module has to be seperated from the
basis-unit.
b) Environmental requirements
The protection-class corresponds to IP21, therefore the ES5400 has to be used inside of
buildings an in dry rooms. For the usage in humid rooms or in dusty environment, specially
designed products are offered.
c) Combination with peripheral devices
For the operation with peripheral devices the operating instructions, technical specifications
of the devices have to be observed.
d) Installation / maintenance
Installation and maintencae must be executed without power supply – danger of injury or
damage of the product or devices.
e) Sensitivity against contact (z.B. ESD)
Never touch electronical components or circuits of the circuit board, otherwise you could
damage the wallreader irreparable.
f) Combination with electrical door openers / special time zones
If a special time zone should be used, which operates an electrical door opener for a longer
time-period (> 20 s, e.g. opening from 9 to 12 am), you must use a door opener which could
endure permanent power.
g) Non-operating at blackout
During a blackout (no power-supply) the wallreader is non-operational. The wallreader has
an included battery-buffer, which guarantees the perservation of the stored data
(programming, internal clock) Nonetheless plase check the internal time after a longer
blackout. If a special time zone or a manual activated toggle-function was in work during the
blackout, it will be automatically deactivated for security reasons, even if it should be active in
the moment after the blackout. For example: A special time zone has been programmed
between 2 and 4 pm. During this time the relay is activated, a peripheral electrical door

HEWI installation instruction
M1000_117_ES5400_EN_Vers-002.pdf M1000.117 Page 2of 7
HEWI P.O. Box 1260 D-34442 Bad Arolsen
opener is active, the door can be used by everyone without valid access-rights. At 3 pm a
blackout occures, at half past 3 the power supply returns. The relay isn’t activated any more,
the door can only be opened by people with vaild access-rights.
h) Danger of lock-out or lock-in during installation
Ensure, that during the installation of a wallreader combined with a door-lock, the door can
always be opened manually, even if the wallreader or the door-lock is not working (e.g.
because of incorrect installation). Always make complete function-test after installation.
i) Interferences
Strong electro-magnetic fields (e.g. transformers, tomographs, ...) and transmitters (IT-
networks, telecommunications, ...) near the wallreader can cause malfunction or
interferences!
Variations
The wallreader ES5400 can be expanded with additional reader-modules ES5401 bzw.
ES5402. These can be connected with the connection-bar. For Details see the installation
manual of those products.
Alternatives
Alternative to the compact-wallreader ES5400 the basis-unit ES5403 in combination with the
reader-module ES5401 or ES5402 can be used.
Preparation of installation
Please check before the installation, if the wallreader you tend to install is suitable for your
application! Check especially:
•Electrical data (voltage, current, power) of the wallreader and the peripheral devices.
•Suitability of the wallreader for the environment, especially the protection class IP21.
•The request at security of the system. In doubt always use an additional reader-module
which will be installed on the „unsecure“ side, in combination with a basis-unit ES5403 or
the compact-wallreader ES5400, installed on the „secure“ side.
•Please notice, that the security of the whole system always depends on the quality of
peripheral devices such as doors, self-locking-locks, burglar-protected products, or an
alarm-device. In addition the installation has always to consider the supposed attacking-
direction.
•Please let security-relevant installations be implemented by suitable specialists.
Required Tools
For the installation a screwdriver or a suitable screwdriver for mounting other screws is
needed. To strip the connection cables a cable stripper or a side cutter is needed.
Attention: After the installation the relays are active. Therefore a door opener could be active.
According to the application, a door could be unlocked and used by everyone. If this is not
wished, please programm the wallreader instantaneously using the HEWIKey5
Administration-software, the programming device and the programming key / card. In doubt
please contact the HEWI Servicecenter locking systems, fon +49 5691 82-200.
Ensure, that during the installation of a wallreader combined with a door-lock, the door-lock,
the door can always be opened manually, even if the wallreader or the door-lock is not
working (e.g. because of incorrect installation). Always make a complete function-test after
installation.

HEWI installation instruction
M1000_117_ES5400_EN_Vers-002.pdf M1000.117 Page 3of 7
HEWI P.O. Box 1260 D-34442 Bad Arolsen
Description of standard-installation
1. Lock the wallreader in backside of the
cover ES5410.
Attention!
The LED should be in the upper left corner
(then the HEWI-Logo is readable).
2. Position of LED in the upper left corner.
Assemblydrills horizontal or vertically,
matching to the conceiled socket.
3. The sub-finery-socket (depth min. 40
mm) should be mounted smooth to the
wall.

HEWI installation instruction
M1000_117_ES5400_EN_Vers-002.pdf M1000.117 Page 4of 7
HEWI P.O. Box 1260 D-34442 Bad Arolsen
4. Install all neccessary connections
(power supply, relay, etc.) as shown in the
wiring plan beyond. Plug the still
connection cables into the right connector.
They fit automatically.
4a. De-Installation:
Move the lever with a small screwdriver (or
smthg. similar) and remove the cable.
5. Mount the wallreader onto the socket
using the enclosed screws. Turn the
screws carefully so that the circuit board
doesn’t become distorted. Check the
adress switch (Must not be at position „0“).
6. Plug the cover onto the wallreader. The
LED should be visible.

HEWI installation instruction
M1000_117_ES5400_EN_Vers-002.pdf M1000.117 Page 5of 7
HEWI P.O. Box 1260 D-34442 Bad Arolsen
After switching on the power-supply, a beep sounds. The red and green LED blink in change
every second. Simultaneously the relays are activated. This is because to ensure the door
opening with non-personalised wall-readers.
For further steps (esp. programming) see the manual of the HEWIKey 5 Administration
software.
Installation in metallic casings / surfaces:
The installation in metallic casings or surfaces is possible if:
•Opening with a diameter of min. 70 mm
•Installation of the wallreader with the installation-plate outside the metallic casing/surface.
•Grounding of the metal-casing.
Description of known problems during installation including correctional
action
Connection cables are too thick and cannot be fitted into the connection-bar:
Please use luster terminals and a short linkup of the cable-type specified in the data-sheet
beyond.
Control of function
Please always check the complete function of the installation.
Maintenance
Basically the ES5400 doesn’t need maintenance. However, we recommend to check the
actuality of the internal time regularly. At least make the checks during the time switches
(summer- wintertime).
We further recommend a regulary check of the correct function of the wallreader, especially
in security-relevant areas. Security relevant can be every area, which will be affected by a
possible malfunction or wrong programming. This means especially alarm-systems, which
are operated by the wallreader or locks in escape- or outside-doors.
Please control the event-protocolls, which can be evaluated using the programming-device
and the HEWIKey Software. Coceivably you´ll find indications of a wrong-programming of the
locking system, which can be critical (e.g. an active toggle-function, which wasn’t planned or
an occured access from a person without access-rights to given time). In that case, please
check the correct programming of the wallreader first (especially time, holidays, special time
zones) and the ident-media (especially access-rights to given time, groups and validity). In
doubt, contact the HEWI Servicecenter locking systems, fon +49 5691 82 – 200.
Care
HEWI products are easy-care. Generally speaking, an occasional wipe with a damp cloth is
enough, however, you fell you have to use detergents, you should take note of the following
information: Only use detergents with ph-rating of between 6 and 8. Detergents containing
active substances such as phospates, soap and tensides may be used. Detergents
containing acids, alkalis, bleach or scouring agents may not be used. Nor should utensils
with a scouring effect such as brushes etc. be used. Usage of any detergent requires full
compliance with the manufacturer’s instructions (concentration, soaking time etc.).
If this is not done, the surface finishes of the HEWI products may suffer as a result and
sustain damage. HEWI accepts no liability whatsoever for damage occuring from incorrect
handling.
For further information please contact HEWI Servicecenter locking systems, fon +49 5691
82-200.

HEWI installation instruction
M1000_117_ES5400_EN_Vers-002.pdf M1000.117 Page 6of 7
HEWI P.O. Box 1260 D-34442 Bad Arolsen
Data sheet
General
Product description Compact wallreader ES5400 / wallreader cover ES5410
Casing
Length x width x height 90 x 90 x 15 mm (cover ES5410)
Material Synthetic
Available colours 12 HEWI colours
Installation depth min. 40 mm (compact-wallreader ES5400)
Installation
diameter
60 mm
Power supply /
connections
Current
1 reader module
up to 6 reader modules
Input
12 - 37 V DC unregulated
23 - 27 V AC
12 - 37 V DC unregulated
23 - 27 V AC
4 - 37 V DC / 4 - 27 V AC 30 - 100 Hz +/- 10%, potentialfree
Current consumption max. 500 mA without load (with 6 reader modules )
Switching capacity Relay Closer/NO max. 40 V AC/DC / 1,6 A
Relay Opener/NC max. 40 V AC/DC / 0,25 A
Relay Opener/NC (Alarm) max. 40 V AC/DC / 0,25 A
Connection cable I-Y(ST)Y 8 x 2 x 0,8
Connectors EK 107 x 107 x 57 mm optional
Power adaptor Depending on number of wallreaders.
Specific data
Operating temperature -20 bis +70 °C
Storage temperature -40 bis +85 °C
Humidity Max. 95% not condensing
Outputs 3 Relays (Photomos-Relays) 1 x NO (Closer), 2 x NC (Opener)
Data interfaces RS485 e.g. for operating a programmable logic controller
Input 2 feedback inputs max. 24 V DC
Reading distance Depending on casing and temperature
- card (ES5931 / ES5932): ca. 80 mm
- key-ring (ES5920): ca. 50 mm
- key (ES5950): ca. 25 mm
All details at room temperature.
Communication with
programming device
Inducticve coupling.
Connection configuration See figure
Memory size 25.000 or 60.000 identifiers (after consultation of HEWI)
Time zones 2 per identifier
Special time zones 20, programmable with administration software HEWIKey5
Tests
CE-test Basic technical standard EN 5002 1081

HEWI installation instruction
M1000_117_ES5400_EN_Vers-002.pdf M1000.117 Page 7of 7
HEWI P.O. Box 1260 D-34442 Bad Arolsen
Wiring plan:
inputs:
J1.1: input 1
J1.2: input 1
J1.3: input 2
J1.4: input 2
J1.5: power supply
J1.6: power supply
Input 1 needs to be connected. If there is no alarm-device in use, the power supply has to be
connected to input 1.
outputs:
J2.1: closer 1 (NO)
J2.2: closer 1 (NO)
J2.3: opener 1 (NC)
J2.4: opener 1 (NC)
J2.5: opener 2 (NC)
J2.6: opener 2 (NC)
Serial interfaces:
J3.1: VCC (onyl for seperated reader-module)
J3.2: RS485-A (onyl for seperated reader-module)
J3.3: RS485-B (onyl for seperated reader-module)
J3.4: GND (onyl for seperated reader-module)
J3.5: RS485-A (SPS-interface)
J3.6: RS485-B (SPS-interface)
Ethernet-connector:
J4 (not available at time)
J1
J2
J3
J4
6 ------- 1
6 ------- 1 6 ------- 1
1 ---- 5
Backside view
Table of contents
Popular Controllers manuals by other brands

DIG
DIG LEIT-2 operating instructions

Greenheck
Greenheck 331-2856 Installation, operation and maintenance

NXP Semiconductors
NXP Semiconductors PN7150 user manual

Partlow
Partlow MIC 1161 Operator's manual

ADLINK Technology
ADLINK Technology NEON-1040 quick start guide

Auber Instruments
Auber Instruments WS-1500A Operation & instruction manual