M1000_117_ES5400_EN_Vers-002.pdf M1000.117 Page 2of 7
HEWI P.O. Box 1260 D-34442 Bad Arolsen
opener is active, the door can be used by everyone without valid access-rights. At 3 pm a
blackout occures, at half past 3 the power supply returns. The relay isn’t activated any more,
the door can only be opened by people with vaild access-rights.
h) Danger of lock-out or lock-in during installation
Ensure, that during the installation of a wallreader combined with a door-lock, the door can
always be opened manually, even if the wallreader or the door-lock is not working (e.g.
because of incorrect installation). Always make complete function-test after installation.
i) Interferences
Strong electro-magnetic fields (e.g. transformers, tomographs, ...) and transmitters (IT-
networks, telecommunications, ...) near the wallreader can cause malfunction or
interferences!
Variations
The wallreader ES5400 can be expanded with additional reader-modules ES5401 bzw.
ES5402. These can be connected with the connection-bar. For Details see the installation
manual of those products.
Alternatives
Alternative to the compact-wallreader ES5400 the basis-unit ES5403 in combination with the
reader-module ES5401 or ES5402 can be used.
Preparation of installation
Please check before the installation, if the wallreader you tend to install is suitable for your
application! Check especially:
•Electrical data (voltage, current, power) of the wallreader and the peripheral devices.
•Suitability of the wallreader for the environment, especially the protection class IP21.
•The request at security of the system. In doubt always use an additional reader-module
which will be installed on the „unsecure“ side, in combination with a basis-unit ES5403 or
the compact-wallreader ES5400, installed on the „secure“ side.
•Please notice, that the security of the whole system always depends on the quality of
peripheral devices such as doors, self-locking-locks, burglar-protected products, or an
alarm-device. In addition the installation has always to consider the supposed attacking-
direction.
•Please let security-relevant installations be implemented by suitable specialists.
Required Tools
For the installation a screwdriver or a suitable screwdriver for mounting other screws is
needed. To strip the connection cables a cable stripper or a side cutter is needed.
Attention: After the installation the relays are active. Therefore a door opener could be active.
According to the application, a door could be unlocked and used by everyone. If this is not
wished, please programm the wallreader instantaneously using the HEWIKey5
Administration-software, the programming device and the programming key / card. In doubt
please contact the HEWI Servicecenter locking systems, fon +49 5691 82-200.
Ensure, that during the installation of a wallreader combined with a door-lock, the door-lock,
the door can always be opened manually, even if the wallreader or the door-lock is not
working (e.g. because of incorrect installation). Always make a complete function-test after
installation.