High Pressure Equipment Company. Erie, PA Page 2
HIP-10RV Field Adjustable Relief Valve
Description:
The purpose of the HiP-10RV field adjustable relief valve is to allow the operator to adjust
system pressures between 1,000 and 10,000 PSI for various test applications.
The standard materials include a stainless steel body and seat glands, EPDM o-rings, Teflon
packing and nylon seats.
Inlet and outlet connections are ¼” female NPT. Reference assembly drawing number 403179
for a detailed parts list and dimensional information.
HIP-10RV Field Adjustable Relief Valve Operating Instructions:
Operating Instructions:
1. Install HIP-10Rv in system. Inlet ports are located on the side of the body. Outlet port is
located at the end of the body opposite of the handle.
2. Loosen the lock nut and back off handle until little or no spring tension is felt.
3. As system is pressurized, turn handle clockwise to set spring tension to desired pressure.
Set lock nut to keep handle from rotating.
4. If system requires an increase or decrease in pressure, loosen the luck nut and adjust
handle to required setting.
Adjustment of the Opening Setting Instructions:
1. Make sure there is no pressure in the valve.
2. Loosen the jam nut.
3. Adjust the set screw clockwise to increase the set pressure and counterclockwise to
decrease the set pressure. Recommended adjustment is one full turn maximum at a time.
4. Test the valve by pressurizing through the inlet port.
5. Depressurize the valve before making further required adjustments.
6. Retighten the jam nut after adjustment is completed.
7. It is recommended that the set pressure be recorded on a wired tag and attached to the
relief valve for reference.