13056 MHz Contactless
iCLASS SE® / multiCLASS SE®
R10E, RP10E, R15E, RP15E, R30E, RP30E, R40E, RP40E, RK40E, RPK40E
R10MA, RP10MA, RP15MA, R40MA, RP40MA, RPK40MA
Parts
1 - iCLASS SE/multiCLASSS SE Reader
1 - Installation Guide
2 - #6-32 x .375” Phillips machine screws
3 - #6-32 x .375” spanner security screw
2 - 7-pin Terminal connectors
1 - 10-pin Terminal connector
1 - Mounting gasket
1 - Back box
Specifications
PRODUCT BASE PART
NUMBER INPUT
VOLTAGE (VDC)
CURRENT1OPERATING
TEMPERATURE5CABLE LENGTH6REGULATORY
REF
NUMBER
Standby
AVG2
Max
AVG3PEAK4
R107900N
5 - 16VDC
12VDC for RS-485
60mA 95mA
200mA -30° to 150° F
(-35° to 65° C)
Communication Lines
Wiegand = 500 ft - 22 AWG
(152 m)
300 ft - 24 AWG
(91 m)
RS-485 = 4000 ft - 4 AWG
(1,219 m)
R10Ex1x2x3
RP107900P 75mA 100mA RP10Ex1x2x3
900L 110mA 135mA
R15 910N 60mA 95 mA R15Ex1x2x3
RP157910P 75mA 100mA RP15Ex1x2x3
910L 110mA 135mA
R30 930N 65mA 95mA R30Ex1x2x3
RP30 930P 85mA 100mA RP30Ex1x2x3
930L 120mA 145mA
R407920N 65mA 95mA R40Ex1x2x3
RP407920P 85mA 100mA RP40Ex1x2x3
920L 120mA 145mA
RK40 921N
5.5 - 16VDC
12VDC for RS-485
85mA 100mA
220mA
RK40Ex1x2x3
RPK407921P 95mA 105mA RPK40Ex1x2x3
921L 130mA 155mA
Recommended
• Cable, 5-9 conductor (Wiegand or Clock-and-Data)
• Linear DC power supply
• Metal or plastic junction box
• Security tool (for anti-tamper screw) HID 04-0001-03
• Drill with various bits for mounting hardware
• Mounting hardware
PLT-01579 A.3
PART NUMBER INPUT VOLTAGE (VDC) CURRENT OPERATING TEMPERATURE FREQUENCY FCC & IC IDs
Standby AVG PEAK
MDP-00870 3.3VDC 22mA 40mA -15° to 150° F (-25° to 65° C) 2.4 - 2.480 GHz FCC-ID: JQ6-ICLASSBTM
IC-ID: 2236B-ICLASSBTM
The final product, containing the modular transmitter must be labeled with its own FCC ID and IC ID. If the FCC & IC ID is not visible, when the module
is installed inside another device, then the final assembly label must contain the FCC and IC ID numbers with a statement such as follows: “Contains
Transmitter Module with FCC ID JQ6-ICLASSBTM and IC ID 2236B-ICLASSBTM”.
BTSmart Module Specifications
UL Reference Number Deciphering
x1Reader Colors: K = Black
x2 Wiring: N = Pigtail T = Terminal
5 = 5 meter Pigtail
x3 Communications:N = No Module,
R = RS-485 (OSDP)
L = Indala Prox
B = Bluetooth
1 Communication protocols other than Wiegand or Clock & Data
(for control panels), as well as credential interfaces over BLE
(not applicable for 9xxL models), require an additional hardware
module which increases current by 30mA.
2 Standby AVG - RMS current draw without a card in the RF eld.
3 Maximum AVG - RMS current draw during continuous card reads.
Not evaluated by UL.
4 Peak - highest instantaneous current draw during RF communication.
5 When congured for Bluetooth Operating Range is -13° to 150° F
(-25° to 65° C)
6 Wiegand Cable Lengths:
100 ft (30.5 m) 22 AWG @ 5 - 6.4VDC
500 ft (152 m) 22 AWG @ 6.5 - 16VDC
7 Mobile Enabled Products, see specications below.

hidglobal.com An ASSA ABLOY Group brand
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output
are fictitious. Specifications are subject to change without notice.
© 2014 - 2015 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS SE are trademarks or registered trademarks of HID Global in the U.S.
and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
INSTALLATION GUIDE iCLASS SE/multiCLASS SE PLT-01579 A.3
R10E, RP10E, R15E, RP15E, R30E, RP30E, R40E, RP40E, RK40E, RPK40E, R10MA, RP10MA, RP15MA, R40MA, RP40MA, RPK40MA
Page 2
Installation
1 Mounting
2 Wiring
Optional Features
Open Collector Output - Controls an external device (16 VDC Max) operating in Host Mode only. Sink - 40mA / Source - 1mA. See the
iCLASS Application Note for details.
Optical Tamper - A configuration card is necessary to activate the Optical Tamper. Once activated, and when the mounting plate is removed, the Optical
Tamper is activated. Contact HID Technical Support for Optical Tamper options.
Configuration Cards - With the use of configuration cards, the reader can be modified to meet the specific requirements of an installation. Configuration
options include; audio visual, CSN outputs and keypad outputs (keypad models only). Contact HID Technical Support for all reader configuration options.
Hold Input - when asserted, this line either buffers a card or disables a card read until released, as configured.
Junction box not included
Gasket optional
P1
P2
18 in
(0.46 m)
BEEP
GRN
GND
+VDC
DRAIN
RED
HOLD
GPI01
GPI02
OC/TMPR
DATA1/CLK
DATA0/DATA
GPI03
GPI04
BEEP
GRN
GND
+VDC
DRAIN
RED
HOLD
GPI01
GPI02
OC/TMPR
DATA1/CLK
DATA0/DATA
GPI03
GPI04
BEEP (YEL)
GRN (ORG)
GND (BLK)
+VDC (RED)
DRAIN (BARE)
RED (BRN)
HOLD (BLU)
GPIO1 (RED/GRN)
GPIO2 (TAN)
OC/TMPR (VIO)
DATA1/CLK(WHT)
DATA0/DATA (GRN)
GPIO3 (PINK)
GPIO4 (GRAY)
ATTENTION
Observe precautions for handling
ELECTROSTATIC SENSITIVE DEVICES
Note: Previous iCLASS readers had reversed
RS-485 wiring ( P2-7 & P2-6 - A & B).
When upgrading to an iCLASS SE reader,
ensure proper connections as dened
below.
* Tamper Output. When activated, output syncs to ground (default).
** Dependent upon reader configuration.
See HTOG Wiegand and Clock-and-Data configurations for more information.
Pigtail Terminal Description Pigtail Terminal Description
Yellow P1-1 Beeper Input Red / Green P2-7 GPIO1 (RS485-FDX/HDX-A)
Orange P1-2 LED Input (GRN) Tan P2-6 GPIO2 (RS485-FDX/HDX-B)
Black P1-3 Ground (RTN) Violet P2-5 * Open Collector Output / Tamper
Red P1-4 +VDC White P2-4 **Wiegand Data 1 / Clock
Drain P1-5 Unused Green P2-3 **Wiegand Data 0 / Data
Brown P1-6 LED Input (RED) Pink P2-2 GPIO3 (RS485-FDX-Z)
Blue P1-7 Hold Input Gray P2-1 GPIO4 (RS485-FDX-Y)

hidglobal.com An ASSA ABLOY Group brand
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output
are fictitious. Specifications are subject to change without notice.
© 2014 - 2015 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS SE are trademarks or registered trademarks of HID Global in the U.S.
and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
INSTALLATION GUIDE iCLASS SE/multiCLASS SE PLT-01579 A.3
R10E, RP10E, R15E, RP15E, R30E, RP30E, R40E, RP40E, RK40E, RPK40E, R10MA, RP10MA, RP15MA, R40MA, RP40MA, RPK40MA
Page 3
iCLASS SE / multiCLASS SE
A seção seguinte é o Guia de instalação traduzido para português (Brasil).
Peças
1 – Leitor iCLASS SE/multiCLASSS SE
1 – Guia de instalação
2 – Parafusos de máquina Phillips nº 6-32 x 0,375pol.
3 – Parafuso de segurança de chave inglesa nº 6-32 x 0,375pol.
2 – Conectores do terminal de 7 pinos
1 – Conector do terminal de 10 pinos
1 – Junta de montagem
1 – Caixa traseira
Especificações
PRODUTO NÚMERO
DE PEÇA BASE TENSÃO
DE ENTRADA (VCC)
CORRENTE1TEMPERATURA
OPERACIONAL5COMPRIMENTO DO CABO6NÚMERO
DE REF.
REGULAMENTAR
MÉDIA em
espera2
MÉDIA
máx.3PICO4
R107900N
5–16VCC
12VCC para RS-485
60mA 95mA
200mA -30° a 150°F
(-35° a 65°C)
Linhas de comunicação
Wiegand = 500pés – 22AWG
(152m)
300pés – 24AWG
(91m)
RS-485 = 4000pés – 4AWG
(1,219m)
R10Ex1x2x3
RP107900P 75mA 100mA RP10Ex1x2x3
900L 110mA 135mA
R15 910N 60mA 95mA R15Ex1x2x3
RP157910P 75mA 100mA RP15Ex1x2x3
910L 110mA 135mA
R407920N 65mA 95mA R40Ex1x2x3
RP407920P 85mA 100mA RP40Ex1x2x3
920L 120mA 145mA
RK40 921N
5,5 – 16VCC
12VCC para RS-485
85mA 100mA
220mA
RK40Ex1x2x3
RPK407921P 95mA 105mA RPK40Ex1x2x3
921L 130mA 155mA
Decifração do número de referência da UL.
x1Cores do leitor: K = Preto
x2 Fiação: N = Cabo flexível T = Terminal
5 = Cabo flexível de
5metros
x3 Comunicações: N = Sem módulo
R = RS-485 (OSDP)
L = Proximidade Indala
B = Bluetooth
1Os protocolos de comunicação exceto o Wiegand ou
o Clock& Data (para painéis de controle), assim como
interfaces de credenciais sobre BLE (não aplicável em
modelos 9xxL), exigem um módulo de hardware adicional
que aumenta a corrente em 30mA.
2 MÉDIA em espera – Consumo de corrente RMS sem um
cartão no campo RF.
3 MÉDIA máxima – Consumo de corrente RMS durante leituras
contínuas de cartões. Não avaliado pela UL.
4Pico – consumo de corrente instantâneo mais alto
durante a comunicação de RF.
5 Quando configurada para o Alcance operacional do
Bluetooth, é de -13° a 150°F (-25° a 65°C)
6 Comprimentos do cabo Wiegand:
100pés (30,5m) 22AWG @ 5–6,4VCC
500pés (152m) 22AWG @ 6,5–16VCC
7
Produtos móveis disponíveis, ver especificações em baixo.
Especificações do módulo BTSmart
NÚMERO DA PEÇA TENSÃO DE ENTRADA
(VCC)
CORRENTE TEMPERATURA OPERACIONAL FREQUÊNCIA IDs da FCC e IC
MÉDIA em
espera PICO
MDP-00870 3,3VCC 22mA 40mA -15° a 150°F (-25° a 65°C) 2,4–2,480GHz ID da FCC: JQ6-ICLASSBTM
ID de IC: 2236B-ICLASSBTM
O produto final que contém o transmissor modular deve estar etiquetado com a sua própria ID da FCC e IC. Se a ID da FCC e IC não
estiver visível quando o módulo for instalado em outro dispositivo, a etiqueta de montagem final deve conter os números da ID da FCC
e IC com este tipo de declaração: "Contém o módulo do transmissor com a ID da FCC JQ6-ICLASSBTM e a ID da IC 2236B-ICLASSBTM".

hidglobal.com An ASSA ABLOY Group brand
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output
are fictitious. Specifications are subject to change without notice.
© 2014 - 2015 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS SE are trademarks or registered trademarks of HID Global in the U.S.
and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
INSTALLATION GUIDE iCLASS SE/multiCLASS SE PLT-01579 A.3
R10E, RP10E, R15E, RP15E, R30E, RP30E, R40E, RP40E, RK40E, RPK40E, R10MA, RP10MA, RP15MA, R40MA, RP40MA, RPK40MA
Page 4
Instalação
3 Montagem
4 Fiação
Recursos opcionais
Saída do coletor aberto – Controla um dispositivo externo (máx. 16VCC) operando somente no Modo Host. Dreno de corrente –
40mA / Fonte de corrente – 1mA.
Optical Tamper – É necessário um cartão de configuração para ativar o Optical Tamper. Uma vez ativado, e quando a placa de
montagem for removida, o Optical Tamper é ativado. Contate o Suporte técnico da HID para obter opções de Optical Tamper.
Cartões de configuração – Com o uso de cartões de configuração, o leitor pode ser modificado para atender aos requisitos
específicos de uma instalação. As opções de configuração incluem audiovisual, saídas de CSN e saídas de teclado (somente modelos
com teclado). Contate o Suporte técnico da HID para todas as opções de configuração do leitor.
Entrada de retenção – quando ativada, esta linha armazena um cartão em buffer ou desativa a leitura de um cartão até ser liberada,
conforme configurada.
Caixa de junção não incluída
Junta opcional
P1
P2
18 in
(0.46 m)
BEEP
GRN
GND
+VDC
DRAIN
RED
HOLD
GPI01
GPI02
OC/TMPR
DATA1/CLK
DATA0/DATA
GPI03
GPI04
BEEP
GRN
GND
+VDC
DRAIN
RED
HOLD
GPI01
GPI02
OC/TMPR
DATA1/CLK
DATA0/DATA
GPI03
GPI04
BEEP (YEL)
GRN (ORG)
GND (BLK)
+VDC (RED)
DRAIN (BARE)
RED (BRN)
HOLD (BLU)
GPIO1 (RED/GRN)
GPIO2 (TAN)
OC/TMPR (VIO)
DATA1/CLK(WHT)
DATA0/DATA (GRN)
GPIO3 (PINK)
GPIO4 (GRAY)
ATENÇÃO
Observe as precauções para o manuseamento
de DISPOSITIVOS SENSÍVEIS A
DESCARGAS ELETROSTÁTICAS
Nota: Os leitores iCLASS anteriores tinham
uma ação RS-485 invertida (P2-7 e
P2-6 – A e B). Ao atualizar para um leitor
iCLASS SE, verique se as conexões
estão corretas conforme denido abaixo.
Cabo flexível Terminal Descrição Cabo flexível Terminal Descrição
Amarelo P1-1 Entrada de bíper Vermelho/Verde P2-7 GPIO1 (RS485-FDX/HDX-A)
Laranja P1-2 Entrada de LED (GRN) Marrom-claro P2-6 GPIO2 (RS485-FDX/HDX-B)
Preto P1-3 Terra (RTN) Violeta P2-5 * Saída do coletor aberto/Tamper
Vermelho P1-4 +VCC Branco P2-4 **Dados Wiegand 1/Relógio
Dreno P1-5 Não utilizado Verde P2-3 **Dados Wiegand 0/Dados
Marrom P1-6 Entrada de LED (VERMELHO) Rosa P2-2 GPIO3 (RS485-FDX-Z)
Azul P1-7 Entrada de retenção Cinza P2-1 GPIO4 (RS485-FDX-Y)
* Saída de tamper. Quando ativada, a saída é sincronizada com a terra (padrão).
** Dependente da configuração do leitor.
Consulte as configurações do HTOG Wiegand e Clock-and-Data para obter mais informações.

hidglobal.com An ASSA ABLOY Group brand
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output
are fictitious. Specifications are subject to change without notice.
© 2014 - 2015 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS SE are trademarks or registered trademarks of HID Global in the U.S.
and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
INSTALLATION GUIDE iCLASS SE/multiCLASS SE PLT-01579 A.3
R10E, RP10E, R15E, RP15E, R30E, RP30E, R40E, RP40E, RK40E, RPK40E, R10MA, RP10MA, RP15MA, R40MA, RP40MA, RPK40MA
Page 5
Regulatory
The final product, containing the modular transmitter must be labeled with its own FCC ID and IC ID. If the FCC & IC ID is not visible,
when the module is installed inside another device, then the final assembly label must contain the FCC and IC ID numbers with a
statement such as follows: “Contains Transmitter Module with FCC ID JQ6-ICLASSBTM and IC ID 2236B-ICLASSBTM”.
UL
Connect only to a Listed Access Control / Burglary power-limited power supply. These readers are intended to be
used with listed (UL294) control equipment. Suitable for outdoor use.
Only Wiegand and RS-485 communications have been evaluated by UL.
FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation.
CAUTION: Any changes or modifcations to this device not explicitly approved by the manufacturer could void your authority to
operate this equipment.
Indala Prox products RP10EL, RP15EL, RP30EL, RP40EL and RPK40EL are certified for FCC, Canada Radio Certification and CE
Marking only.
Canada Radio Certification
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause
undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter
tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
CE Marking
HID Global hereby declares that these proximity readers are in compliance with the essential requirements and other relevant
provisions of Directive 1999/5/EC.
Por el presente, HID Global declara que estos lectores de proximidad cumplen con los requisitos esenciales y otras disposiciones
relevantes de la Directiva 1999/5/EC.
HID Global déclare par la présente que ces lecteurs à proximité sont conformes aux exigences essentielles et aux autres stipulations
pertinentes de la Directive 1999/5/CE.
A HID Global, por meio deste, declara que estes leitores de proximidade estão em conformidade com as exigências essenciais e
outras condições da diretiva 1999/5/EC.
HID Global bestätigt hiermit, dass die Leser die wesentlichen Anforderungen und anderen relevanten Bestimmungen der Richtlinie
1999/5/EG erfüllen.
HID Global dichiara che i lettori di prossimità sono conformi ai requisiti essenziali e ad altre misure rilevanti come previsto dalla
Direttiva europea 1999/5/EC.
Download copies of the R&TTE Declaration of Conformity (DoC) at http://www.hidglobal.com/certifications.
Taiwan
According to “Administrative Regulations on Low Power Radio Waves Radiated Devices” Without permission granted by the NCC, any
company, enterprise, or user is not allowed to change frequency, enhance transmitting power or alter original characteristic as well
as performance to a approved low power radio-frequency devices. The low power radio-frequency devices shall not influence aircraft
security and interfere legal communications; If found, the user shall cease operating immediately until no interference is achieved. The
said legal communications means radio communications is operated in compliance with the Telecommunications Act. The low power
radio-frequency devices must be susceptible with the interference from legal communications or ISM radio wave radiated devices.
Japan MIC
“ この装置は総務省の型式指定を受けています。”
(総務省指定番号は第AC-xxxxx号です)
本製品は電波を使用したRFID 機器の読み取り・書き込み装置です。
そのため使用する用途・場所によっては、医療機器に影響を与える恐れがあります

hidglobal.com An ASSA ABLOY Group brand
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output
are fictitious. Specifications are subject to change without notice.
© 2014 - 2015 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS SE are trademarks or registered trademarks of HID Global in the U.S.
and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
INSTALLATION GUIDE iCLASS SE/multiCLASS SE PLT-01579 A.3
R10E, RP10E, R15E, RP15E, R30E, RP30E, R40E, RP40E, RK40E, RPK40E, R10MA, RP10MA, RP15MA, R40MA, RP40MA, RPK40MA
Page 6
Singapore
Korean KCC
Israel (Mobile Ready RP10)
השימוש במכשיר הינו על בסיס "משני" ופטור מרשיון הפעלה אלחוטי.
רק "בפעולת בזק" לשימוש עצמי של הלקוח בלבד, הלקוח פטור מרשיון הפעלה אלחוטי.
אסור להחליף את האנטנה המקורית של המכשיר, ולא לעשות בו כל שינוי טכני אחר.
Brazil
Compliance Statement
Este produto está homologado pela ANATEL, de acordo com os procedimentos regulamentados pela Resolução 242/2000, e atende
aos requisitos técnicos aplicados. Para maiores informações, consulte o site da ANATEL - www.anatel.gov.br
This product is homologated at ANATEL according to procedure regulated by Resolution 242/2000, and it complies with the
applicable technical requirements. For more information, consult ANATEL website - www.anatel.gov.br
RF Warning Statement
Per Article 6 of Resolution 506, equipment of restricted radiation must carry the following statement in a visible location:
Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de estações
do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário.
This equipment operates in secondary character, meaning it does not have the right of protection against harmful interference, even
against those the same character, and it cannot cause any interference to systems operating in the primary character.
Complies with
IDA Standards
DA103548
R10E, R15E,
R30E,R40E, RK40E
RP10E, RP15E, RP30E,
RP40E, RPK40E
Mobile Ready
R10MA, RK40MA RP10MA
항목 규격 규격
송신주파수 RFID:13.56 MHz RFID:13.5607 MHz,
LPD:125 KHz
RFID:13.56 MHz
RFID: 2.40 - 2.48 GHz
RFID:13.56 MHz
RFID: 2.40 - 2.48 GHz
LPD:125 KHz
수신주파수 RFID:13.56 MHz RFID:13.56 MHz,
LPD:125 KHz
RFID:13.56 MHz
RFID: 2.40 - 2.48 GHz
RFID:13.56 MHz
RFID: 2.40 - 2.48 GHz
LPD:125 KHz
출력 RFID: 10m에서
47.544mv이하
RFID: 10m에서 47.544mv이하.
LPD:3 m 거리에서 500 ㎶/m이하
HF RFID: 10m에서 3108.1 ㎶/m
BLE RFID: 10m에서 EIRP -3.9 dBm/1 MHz
LF RFID: 10m에서 31.6 ㎶/m
HF RFID: 10m에서 498.9 ㎶/m
BLE RFID: 10m에서 EIRP -3.9 dBm/1 MHz
전원 DC 16.0V DC 16.0V
전파형식 A1D A1D
발진방식 X-tal X-tal (13.56MHz)
Resonator(125kHz) X-tal (13.56 MHz & 2.4 GHz) X-tal (13.56 MHz & 2.4 GHz)
Resonator (125kHz)
변조방식 ASK ASK(13.56MHz), FSK(125kHz) HF: ASK, BLE: GFSK LF:FSK, HF: ASK, BLE: GFSK

hidglobal.com An ASSA ABLOY Group brand
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output
are fictitious. Specifications are subject to change without notice.
© 2014 - 2015 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS SE are trademarks or registered trademarks of HID Global in the U.S.
and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
INSTALLATION GUIDE iCLASS SE/multiCLASS SE PLT-01579 A.3
R10E, RP10E, R15E, RP15E, R30E, RP30E, R40E, RP40E, RK40E, RPK40E, R10MA, RP10MA, RP15MA, R40MA, RP40MA, RPK40MA
Page 7
iCLASS Keypad Readers
FOTO SELO ANATEL
Fabricante: HID Global Corporation
Modelo: iCLASS SE RK40E, multiCLASS RPK40E
Este produto esta aprovada pela Anatel, de acordo com os procedimentos regulamentados pela
Resolução nº 242/2000 e atende aos requisitos técnicos aplicados.
“Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de
estações do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário”
iCLASS Non-Keypad Readers
FOTO SELO ANATEL
Fabricante: HID Global Corporation
Modelo: iCLASS SE R10, multiCLASS RP10E, multiCLASS RP30E iCLASS SE R40E, multiCLASS RP15E, multiCLASS RP40E
Este produto esta aprovada pela Anatel, de acordo com os procedimentos regulamentados pela
Resolução nº 242/2000 e atende aos requisitos técnicos aplicados.
“Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de
estações do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário”
Mobile Ready Readers
FOTO SELO ANATEL
Fabricante: HID Global Corporation
Modelo: iCLASS SE RP10MA
Este produto esta aprovada pela Anatel, de acordo com os procedimentos regulamentados pela
Resolução nº 242/2000 e atende aos requisitos técnicos aplicados.
“Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de
estações do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário”

hidglobal.com An ASSA ABLOY Group brand
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample
output are fictitious. Specifications are subject to change without notice.
© 2014 - 2015 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS SE are trademarks or registered trademarks of HID Global in the U.S.
and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
iCLASS SE/multiCLASS SE PLT-01579 A.3
R10E, RP10E, R15E, RP15E, R30E, RP30E, R40E, RP40E, RK40E, RPK40E
Page 8
INSTALLATION GUIDE iCLASS SE/multiCLASS SE PLT-01579 A.3
R10E, RP10E, R15E, RP15E, R30E, RP30E, R40E, RP40E, RK40E, RPK40E, R10MA, RP10MA, RP15MA, R40MA, RP40MA, RPK40MA
HID Global
Americas & Corporate
611 Center Ridge Drive
Austin, TX 78758
USA
Support: 866-607-7339
Fax: 949-732-2120
Asia Pacific
19/F 625 King's Road
North Point, Island East
Hong Kong
Support: 852-3160-9833
Fax: 852-3160-4809
Europe, Middle East & Africa
Phoenix Road
Haverhill, Suolk CB9 7AE
England
Support: 55 11 5514-7100
Fax: 55 11 5514-7109
For additional oces around the world, see www.hidglobal.com corporate oces.
HID Global Customer Support: support.hidglobal.com
Equipment
8T29
ACC Control READER
General Signaling
Equipment
The following certifications apply to the BSTmart Module:
Russia
Дата изготовления указана на маркировке оборудования
Представитель в Российской Федерации
Название ООО «Дофин»
Адрес 140573, РФ, Московская обл., Озерский район, с. Бояркино
Контактное лицо Л.Н. Голубова
Телефон +7 495 223 6008
e-mail [email protected]
UAE
TRA
REGISTERED NO:
nnnnnnn
DEALER NO:
DA37204/14

This manual suits for next models
15
Table of contents
Languages:
Other HID Card Reader manuals

HID
HID Mercury MR62e User manual

HID
HID OMNIKEY 5121 User manual

HID
HID iCLASS RK40 User manual

HID
HID ProxPoint Plus User manual

HID
HID ProxPro II Reader User manual

HID
HID Technology Solutions 1139 User manual

HID
HID Miniprox User manual

HID
HID iCLASS R10 User manual

HID
HID iCLASS SE User manual

HID
HID iCLASS R10 User manual

HID
HID iCLASS RK40 User manual

HID
HID Signo Series User manual

HID
HID MiniProx 5365 User manual

HID
HID multiCLASS RMK40 User manual

HID
HID ProxPro II 5455 User manual

HID
HID MaxiProx DFM Reader - 5375 User manual

HID
HID OMNIKEY 5121 User manual

HID
HID iCLASS bio500 User manual

HID
HID iCLASS RK40 User manual

HID
HID SmartID SK10 User manual