Page 1
13.56 MHz Contactless
iCLASS SE® / multiCLASS SE®
R10E, RP10E, R15E, RP15E, R40E, RP40E, RK40E, RPK40E
R10MA, RP10MA, RP15MA, R40MA, RP40MA, RPK40MA
Parts
1 – iCLASS SE/multiCLASSS SE Reader
1 – Installation Guide
2 – #6-32 x .375” Phillips machine screws
3 – #6-32 x .375” spanner security screw
2 – 7-pin Terminal connectors
1 – 10-pin Terminal connector
Recommended
• Cable, 5-9 conductor (Wiegand or Clock-and-Data), 4 conductor Twisted
Pair Over-All Shield and UL approved, Belden3107A or equivalent (OSDP)
• Linear DC power supply
• Metal or plastic junction box
• Security tool (for anti-tamper screw) HID 04-0001-03
• Drill with various bits for mounting hardware
• Mounting hardware
• Reader spacer when mounting on or near metal or metal junction boxes -
see How to Order Guide
• IP65 Mounting gasket, recommended for outdoor installation
• Back box
Specification
PRODUCT BASE PART
NUMBER INPUT
VOLTAGE (VDC)
CURRENT1OPERATING
TEMPERATURE5CABLE LENGTH6REGULATORY
REF NUMBER
STANDBY
AVG2
MAX
AVG3PEAK4
R107900N
5 - 16VDC
60mA 95mA
200mA
-30° to 150° F
(-35° to 65° C)
Communication Lines
Wiegand = 500 ft - 22 AWG (152 m)
300 ft - 24 AWG 91 m)
RS-485 = Max bus length
4000 ft - 24 AWG (1,219 m)
Max length between nodes:
1640 ft - 24 AWG (500m)
R10Ex1x2x3
RP107900P 75mA 100mA RP10Ex1x2x3
900L 110mA 135mA
R15 910N 60mA 95 mA R15Ex1x2x3
RP157910P 75mA 100mA RP15Ex1x2x3
910L 110mA 135mA
R407920N 65mA 95mA R40Ex1x2x3
RP407920P 85mA 100mA RP40Ex1x2x3
920L 120mA 145mA
RK40 921N
5.5 - 16VDC
85mA 100mA
220mA
RK40Ex1x2x3
RPK407921P 95mA 105mA RPK40Ex1x2x3
921L 130mA 155mA
BTSmart Specifications
OPERATING TEMPERATURE FREQUENCY FCC & IC IDS
-15° to 150° F (-25° to 65° C) 2.4 - 2.480 GHz FCC-ID: JQ6-ICLASSBTM
IC-ID: 2236B-ICLASSBTM
The final product, containing the modular transmitter must be labeled with its own FCC ID and IC ID. If the FCC & IC ID is not visible, when the module
is installed inside another device, then the final assembly label must contain the FCC and IC ID numbers with a statement such as follows: “Contains
Transmitter Module with FCC ID JQ6-ICLASSBTM and IC ID 2236B-ICLASSBTM”.
1 Communication protocols other than Wiegand or Clock & Data
(for control panels), as well as credential interfaces over BLE
(not applicable for 9xxL models), require an additional
hardware module which increases current by 40mA.
2 Standby AVG - RMS current draw without a card in the RF field.
3 Maximum AVG - RMS current draw during continuous card reads.
Not evaluated by UL.
4 Peak - highest instantaneous current draw during RF communication.
5 When configured for Bluetooth Operating Range is -13° to 150° F
(-25° to 65° C)
6 Wiegand Cable Lengths:
100 ft (30.5 m) 22 AWG @ 5 - 6.4VDC
500 ft (152 m) 22 AWG @ 6.5 - 16VDC
7 Mobile Enabled Products, see specifications below.
UL Reference Number Deciphering
x1Reader Colors: K = Black
x2Wiring: N = Pigtail
T = Terminal
5 = 5 meter Pigtail
x3Communications: N = No Module
R = RS-485 (OSDP)
L = Indala Prox