HIGOLD 973005 User manual

High-End Kitchen Functional Hardware
INTELLIGENT FOOD PURIFICATION SINK
PRODUCT OPERATION INSTRUCTION
Foshan Shunde Higold Hardware Product Manufacturing Co., Ltd
T: +86 757 2738 6292
E: sales_sink@higold.com.cn

Dear users!
Thank you very much for choosing our food purification series of
smart kitchen utensils.
Now you begin to become the most intimate food safety guard around,
Let you share delicious meals with your family.
Please read this manual carefully before use and follow its requirements.
[Product Operation Instruction] is the control concept that has been
tested and verified.
It is very important to maintain the good working condition and safe use of
products. If the product fails due to improper use, it will be damaged.
This Instruction is only suitable for Higold food purification series.
Higold reserves the right of final interpretation.
FOREWORD


PRODUCT
INTRODUCTION
01 - PURIFICATION TANK
1.1 General Introduction

Detoxification
Freshness Retaining
Sterilization
Cleaning
1. Family
2. Canteen of university, high school, middle school,
primary school, kindergarten, etc.
3. Canteen of company, factory, shopping mall, etc.
4. Hotel and dining establishment
5. Canteen of government, army and other institutions
UNPACKING AND
INSTALLATION
When the purification sink is damaged or not working properly, stop using it
immediately and unplug it.
Please contact the local dealer or call the after-sales service department for
maintenance.
The purification sink is maintained by professionals trained by the manufacturer.
Please do not detach/repair it by yourself.
■ When installing the purification sink, please power on and get normal operation
before installation in order to eliminate the malfunctions caused by improper
transportation.
■
■
■
03 - PURIFICATION TANK - 02PURIFICATION TANK
1.4 Main Functions
1.5 Application Range
2.1 Inspection after Opening the Carton

Y-22mm
Topmount Installation
NO.
Note: Glass glue and marble glue are needed for undermount installation.
PURIFICATION TANK


1. Confirm to turn off the switch on the host before connecting.
2. Plug in the power cord with 3C certification correctly.
3. Install the socket with effective ground wire correctly in the best position of moistureproof
and waterproof.
4. Plug the power cord into the socket and turn on the bottom switch of the purification
machine.
5. Operation and use.
LED/DC12V
AC220V
DC24V
Power
panel
Main
panel
Input power/AC220V
Air-operated/¢6
Generator/DC24V
Control panel/DC5V
Air-
operated
Do not plug in or pull out the power
cord when your hand is wet. Do no
hold the cord when plugging in or
pulling out the power cord.
When using the purification sink
for the first time, firstly clean the
inside of the sink and the inside of
the purification generator. Then
put in tap water. The water level
shall not be lower than the lowest
water level in the sink. Turn on
power and make it work for 2-3
times and then drain the water.
09 - PURIFICATION TANK - 08PURIFICATION TANK
2.4 Electrical Principle and Connection Description
Connection Instructions
PRECAUTIONS
3.1 During Installation
3.2 Before Use
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agentor similarly qualified persons in order to avoid a hazard.
This appliance can be used by children aged from 8 years and above and
persons with reduced physical,sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision orinstruction
concerning use of the appliance in a safe way and
understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children withoutsupervision.
Keep the appliance and its cord out of reach of children less than 8 years
This appliance is intended to be used in household and similar applications such as:
- staff kitchen areas in shops, offices and other working environments;
- farm houses;
- by clients in hotels, motels and other residential type environments;
- bed and breakfast type environments.

If there is no reaction or effect of purification in use, please consult to the after-sales
or professional personnel for inspection and maintenance. Do not open the electronic
control components without permission.
In case of abnormity or peculiar smell in use, please immediately unplug the power
supply and consult to the after-sales or professional personnel for inspection and
maintenance. Do not open the electronic control components without permission.
If the key is not sensitive in use, please check whether there is sundry or water
droplet on the key, or consult to the after-sales or professional personnel for
inspection and maintenance. Do not open the control panel without permission.
Children or people without relevant knowledge and experience, as well as people
with physical, perceptual or mental disability, must use the product under the
supervision and guidance of a safe guardian.
When the electronic control parts need to be repaired, please consult to the
after-sales or professional personnel for maintenance. Do not replace the parts
without permission. Using improper parts may cause further damage to the
product.
11 - PURIFICATION TANK - 10PURIFICATION TANK
3.3 In Use

2
3
4
5
678
1
5.2 Introduction to Operation Panel
5
2
3
1
4
Long press the power button for 3 seconds to enter the standby mode of
the purification system.
Make sure that the power switch is turned on, put the food to be purified in the
sink and add an appropriate amount of water, the water level must not be lower
than the lowest water level in the sink (covering the generator filter).
Press the [console] button (the water seal cap of the sewer is closed)

Possible reasons:
① No power connection.
② The purification main machine is not
switched on.
③ There are sundries in the generator.
MAINTENANCE
15 - PURIFICATION TANK
6.1 General Knowledge to Maintenance
COMMON
MALFUNCTIONS
7.1 Power button cannot be turned on or automatically reset
Or click the [power] button to turn off the system.
Pull the [console] button to drain water.
Then click the [start / stop] button, the purification system starts to work, and the
display shows the countdown working time.
When the purification is completed, it will stop purification automatically and ring
five times to indicate the end of purification.
The food can be taken out after the work.
Use the faucet with nozzle to wash the generator and sink.
Select the food button and click it , if vegetables, click the [fruits and vegetables]
button.

Possible reasons:
① There is water or sundry
on the touch glass panel.
- 16PURIFICATION TANK
7.2 Button skips or doesn't work when touched
7.3 Purification effect is obviously reduced
This manual suits for next models
3
Table of contents
Popular Plumbing Product manuals by other brands

Onyx
Onyx Full Showers with Return installation instructions

Fackelmann
Fackelmann LINO installation instructions

ProFlo
ProFlo PF603BN installation instructions

Orbital Systems
Orbital Systems Oas Indo OS8732 Ei2 manual

Omnires
Omnires Y1233BL Installation and Maintenance

Kemper
Kemper KHS HS2 Series Maintenance manual