Hillrom Liko MasterVest 60 User manual

Product Descripon
Liko MasterVest is a versale sling with a wide range of uses,
for example, help with standing and walking or vising the
toilet.
MasterVest supports the paent around the upper body as
well as under the arms. MasterVest requires paents to be
able to parally bear weight on their legs.
Liko MasterVest enables you to reach certain dicult-to-
achieve goals, for example:
- paents receive appropriate help to exercise and bear
weight on their legs, and
- caregivers avoid risks associated with heavy liing.
Liing and transferring paents to and from the toilet
can lead to severe injuries for the caregiver. MasterVest
facilitates smooth and simple transfers to and from the
toilet.
Since MasterVest covers only the upper body, the lower body
is easily accessible for dressing and undressing.
Front closure MasterVest, Mod. 64
The front closure model of Liko MasterVest Mod. 64 can be
used for paents who are able to put on and take o the
vest by themselves.
The front closure MasterVest is equipped with two adjustable
safety clasps across the chest. These are also recommended in
cases where it is necessary to adjust the tension and regulate
pressure on the chest.
MasterVest with Leg Harness
The leg harness holds MasterVest in place and is commonly
used in walking training.
Mod. 60 Mod. 64 Mod. 60
with leg harness
and padded cases
Liko™ MasterVest™ Mod. 60, 64
Instrucons for Use
7EN160168 Rev. 10
ENGLISH 2020
In this document, the person being lied is referred to as the paent, and the person helping is referred to as the caregiver.
IMPORTANT!
Liing and transferring a paent always involves a certain level of risk. Read the instrucons for use for both the paent
li and liing accessories before use. It is important to completely understand the contents of the instrucons for use.
The equipment should only be used by trained personnel. Ensure that the liing accessories are suitable for the li used.
Exercise care and cauon during use. As a caregiver, you are always responsible for the paent’s safety. You must be aware
of the paent’s ability to make it through the liing situaon. If something is unclear, contact the manufacturer or supplier.

2
7EN160168 Rev. 10 • 2020 www.hillrom.com
Table of Contents
Symbol Descripon .......................................................................................................................... 3
Safety Instrucons ........................................................................................................................... 4
Care and Maintenance ..................................................................................................................... 5
Denions ........................................................................................................................................ 5
How to Aach a Sling to Dierent Sling Bars .................................................................................... 6
How to Aach a MasterVest to a Twin Bar ....................................................................................... 7
Liing from a Seated Posion........................................................................................................... 8
Tesng the Liko MasterVest .............................................................................................................. 9
Accessories ..................................................................................................................................... 11
Overview Liko™ MasterVest™ Mod. 60, 64 .................................................................................... 12
Recommended Combinaons ........................................................................................................ 12

3
7EN160168 Rev. 10 • 2020 www.hillrom.com
These symbols can be found in this document and/or on the product.
Symbol Descripon
Symbol Descripon
Warning. Used were extra care and aenon is needed.
Read instrucons for use before use
CE mark
Legal manufacturer
Date of manufacturing
Ref number
Serial Number
Medical device
Do not dry clean
Do not iron
Tumble drying
Do not tumble dry
Washing
Symbol is always in combinaon with recommended temperature
in °C and °F.
Latex Free
Periodic inspecon
Do not bleach
Line drying in shade
Facing Out Direcon upwards and symbol on outside of equipment.
Facing Out Symbol on outside of equipment.
(01) 0100887761997127
(11) Y Y M MD D
(21) 012345678910
GS1 Data Matrix Barcode that may contain following informaon.
(01) Global Trade Item Number
(11) Producon Date
(21) Serial Number

4
7EN160168 Rev. 10 • 2020 www.hillrom.com
Before liing, keep the following points in mind:
• A responsible person within your organizaon should decide on a case-by-case basis whether one or more caregivers are
needed.
• Ensure that the sling selected meets the paent’s needs with reference to model, size, fabric and design.
• Test the emergency lowering device on the li you are using to make certain that it funcons properly.
• Adjust the maximum height so that it will be impossible to raise a paent too high.
• For safety and hygiene reasons, use individual slings.
• Before liing, plan the liing operaon so that it can be done as safely and smoothly as possible.
• Before liing, check that the liing accessory hangs vercally and can move freely.
• Although the Liko sling bars are equipped with latches, special cauon must be exercised: before the paent is lied from
the underlying surface, but when the straps are fully extended, make sure the straps are correctly connected to the sling bar
hooks.
• Never li a paent higher o the underlying surface than is needed to complete the liing and transfer procedure.
• Never leave a paent unaended during a liing situaon.
• Make sure that the wheels on the wheelchair, bed, gurney, etc., are locked during the liing/transfer operaon.
• Always work ergonomically. Use the paent’s ability to acvely parcipate in the operaons.
• When the sling is not being used, do not place in direct sun light.
Incorrect aachment of sling to slingbar may cause severe injury to the paent.
Safety Instrucons
PATENT www.hillrom.com/patents
May be covered by one or more patents. See above Internet address.
The Hill-Rom companies are the proprietors of European, US, and other patents and pending patent applicaons.
Product Changes
Liko’s products undergo connuous development, which is why we reserve the right to make product changes without prior
noce. Contact your Hill-Rom representave for advice and informaon about product upgrades.
Design and Quality by Liko in Sweden
Liko is quality cered according to ISO 9001 and its
equivalent
for the medical device industry ISO 13485.Liko is also cered
according to environmental standard ISO 14001.
Noce to Users and/or Paents in EU
Any serious incident that has occurred in relaon to the device, should be reported to the manufacturer and the competent
authority of the Member State in which the user and/or paent is established.
Medical Device Class I Product

5
7EN160168 Rev. 10 • 2020 www.hillrom.com
mod. 60
mod. 64
1. Loop straps
2. Shoulder straps
3. Upper edge
4. D-rings
5. Leg harness loops
6. Size marking
7. Product label
8. Serial number
9. Label: Periodic inspecon
10. Label: Individual marking (Belongs to)
11. Safety buckles
4
5
6
7
8
9
10
11
3
2
1
5
6
3
2
1
7
8
9
10
4
Denions
Check the sling before each use. Check the following points with regard to wear and damage:
• Fabric
• Straps
• Seams
• Loops
• Buckles
Do not use damaged liing accessories.
If anything is unclear, please contact the manufacturer or supplier.
If the sling is used for bath or shower: Aer use in bath and shower situaons, the sling should be placed so that it dries as
soon as possible.
Washing Instrucons: Please see the sling’s product label and the aached appendix ”Care and Maintenance of Liko Slings”.
The safety buckles on Mod. 64 shall be closed during washing.
Periodic Inspecon
The product must be inspected at least once every 6 months. More frequent inspecons might be required if the products are
used or washed more oen than normal. For protocols please contact your Hill-Rom representave.
Expected Life Time
Mod. 60: The product has an expected life me of 1-5 years during normal use.
Mod. 64: The product has an expected life me of 1-4 years during normal use
Life me varies depending on the fabric, use frequency, washing procedure, and weight carried.
Recycling Instrucons
The enre sling, including laths, padding material, etc. should be sorted as Combusble waste.
Hill-Rom evaluates and provides guidance to its users on the safe handling and disposal of its devices to aid in the prevenon
of injury, including, but not limited to: cuts, punctures of the skin, abrasions, and any required cleaning and disinfecon of the
medical device aer use and prior to its disposal. Customers should adhere to all federal, state, regional, and/or local laws and
regulaons as it pertains to the safe disposal of medical devices and accessories.
If in doubt, the user of the device shall rst contact Hill-Rom Technical Support for guidance on safe disposal protocols.
Care and Maintenance

6
7EN160168 Rev. 10 • 2020 www.hillrom.com
Sling bar Sling loops to sling bar hooks Correct
SlingGuard™
Universal
SlingGuard™ Twin
Universal Twin
Wrong!
How to Aach a Sling to Dierent Sling Bars

7
7EN160168 Rev. 10 • 2020 www.hillrom.com
How to Aach a MasterVest to a Twin Bar
1.
2. 3.
B
ABA
A
B
Shoulder strap
Loop strap
A
A
BB

8
7EN160168 Rev. 10 • 2020 www.hillrom.com
Before liing: Check that the paent’s feet are solidly on the oor
so that he/she can bear weight as the sling bar is raised. Raise the
sling bar slightly to ghten the straps (without liing the paent
o the seat), and check that the pressure distribuon around the
paents upper body feels correct.
During the li: Pull the sling bar forward so the paent’s weight is
transferred smoothly unl he/she stands upright and in balance.
Lower the sling bar slightly to relieve pressure around the chest.
Now the paent has an opportunity to put weight on the legs and
work on balance training.
Liing from a Seated Posion
Put on MasterVest from the front.
The paent’s arms are placed through
the shoulder straps.
Behind the back: Draw each loop strap
across the back and pull it through the
metal D-ring on the opposite side, as
shown in the illustraon.
With the sling bar behind the paent’s back,
aach the loop straps, using a suitable loop,
see page 9-10. Aach the shoulder straps to
the sling bar. See page 6-7 for instrucons
on how to aach the sling loops to dierent
sling bars.

9
7EN160168 Rev. 10 • 2020 www.hillrom.com
Selecng the Right Size
For MasterVest to funcon properly, the width of the vest must be in correct proporon to the circumference of the
paent’s upper body. Therefore, it is important to select the right size and carefully determine the correct loop on the loop
strap.
Adjusng the Loop Straps
The loop which you hook onto the sling bar determines how much the vest ghtens around the chest.
If the vest slides upward - try an inner loop or a smaller size of the vest.
If the vest ts too ghtly around the chest - try an outer loop or a larger vest size.
If two dierent people try the same size, the slimmer person would need an inner loop while a bigger person would need
an outer loop. The MasterVest is correctly adjusted when the shoulder straps and loop straps are equally taut when liing
the paent.
The size is right when the gap between the
metal D-rings is between 5 cm (2 inch.) and
30 cm (12 inch.). The larger the size of the
vest, the wider the gap can be.
The size is to small when the gap between
the metal D-rings is too wide, the loop
straps do not reach up to the sling bar, and
the pressure around the chest is too great.
The size is to large when the metal D-rings
touch. The vest is too wide and does not
ghten during liing but slides upward.
A vest that is too large creates too much
pressure under the armpits.
TOO LARGE!
Tesng the Liko MasterVest
Tesng the Loop Straps
This praccal accessory is used to mark the loops that have been
tried out for a certain person. It makes it easier for the caregivers
to choose the right loop to aach to the sling bar.
Loop Clips
To nd which loops give the best ng, test the loop straps by draw-
ing on dierent loops along with the shoulder straps.
To test for the correct ng of the loop straps, stand behind
the patient and suspend the shoulder straps and loop straps
from your thumbs and lift upward until the straps are taut.
The MasterVest ts correctly when the loop straps and shoulder
straps are equally taut when lied.
RIGHT! TOO SMALL!

10
7EN160168 Rev. 10 • 2020 www.hillrom.com
The MasterVest is also available in a front closure model.
The front closure MasterVest is equipped with two adjustable
safety buckles in front. Test for the correct vest size and posi-
on of the loop straps even when paents themselves put
on the MasterVest. Aer the MasterVest has been correctly
adjusted, it can hang from the sling bar while the paent
puts it on.
Liko MasterVest in Plasc-coated Net
The most common sizes of the MasterVest are available in plasc-coated net. Fricon from the material counteracts the tendency
of the vest to slide upward. A MasterVest in plasc-coated net may also be used for bathing.
Problem during Tesng?
Problem: The vest slides up under the paent´s arms.
Adjust the MasterVest using one or more of the following suggesons:
• Adjust the loop strap by using an inner loop.
• Choose a smaller size.
• Try using a Liko MasterVest of plasc-coated net.
• Try using the leg harness.
• Hold the vest in place behind the back while raising the paent by pressing your thumb downward on the crossed loop straps.
• Have the paent keep his/her arms down while liing.
A. B.
An individual may oen t into two dierent sizes of the
MasterVest, but the loop straps must be correctly adjusted
to each size. The results dier regarding body posture and
pressure distribuon around the chest.
A. A larger MasterVest size requires you to use one of the
inner loops on the loop strap. This ng allows the paent
to bend forward, and places more pressure on the lower
front part of the chest.
B. A smaller MasterVest size requires you to aach one of
the outer loops of the loop strap to the sling bar to obtain
equal tension on all four straps. In this case, body posture is
more upright and pressure is more evenly distributed around
the chest.
Body Posture
Front closure MasterVest, Mod. 64

11
7EN160168 Rev. 10 • 2020 www.hillrom.com
Accessories
Leg Harness Prod. No. 3666004-06
A special leg harness can be used with the Liko MasterVest
to help keep the vest from sliding up on the body. The
harness can be put on while the paent is sing, and aer
liing the paent you can adjust the posion and tension of
the harness. The harness straps may be crossed or parallel
through the crotch.
NOTE! The leg harness ts vests from serial number 736166.
Contact your Hill-Rom representave for more informaon
on earlier models.
Aaching the
Leg Harness
Padded cases are available as an accessory to help relieve
pressure on the front shoulder straps.
Padded cases are equipped with Velcro along one side for
easy applicaon.
Padded Case for Shoulder Strap Prod. No. 3666021
Loop Clips
Loop Clips, red, 4 pcs Prod. No. 3666033
Loop Clips, orange, 4 pcs Prod. No. 3666034
Loop Clips, yellow, 4 pcs Prod. No. 3666035
Loop Clips, blue, 4 pcs Prod. No. 3666036
Loop Clips, black, 4 pcs Prod. No. 3666037
Extension Loop
Extension Loop, green, 12 cm (5 in) Prod. No. 3691102
Extension Loop, green 22 cm (9 in) Prod. No. 3691103
Extension Loop, grey, 12 cm (5 in) Prod. No. 3691302
Extension Loop, grey, 22 cm (9 in) Prod. No. 3691303
- 2 = 12 cm (5 in)
- 3 = 22 cm (9 in)

Overview Liko™ MasterVest™ Mod. 60, 64
Dierent sling bar widths create dierent levels of pressure on the chest. Try various alternaves unl you nd the one
best suited to the individual paent.
Other Combinaons
Combinaons with Liko MasterVest and Cross-bar, Cross-bar 450/670 or Side bars is not appropriate.
Combinaons of accessories/products other than those recommended by Liko can result in risks for the safety of the
paent.
¹ Sling bar 450 relates to Universal SlingBar 450 Prod. No. 3156075, 3156085, and 3156095, and also SlingGuard 450 Prod. No. 3308020 and
3308520.
² Twin bars 670 relates to Universal TwinBar 670 Prod. No 3156077, and 3156087, and also SlingGuard 670 Twin Prod. No. 3308040 and
3308540.
³ Sling bar 350 relates to Universal SlingBar 350 Prod. No. 3156074, 3156084, and 3156094.
⁴ Sling bar 600 relates to Universal SlingBar 600 Prod. No. 3156076 and 3156086.
Explanaon: 1 = Recommended, 2 = May work, 3 = Not advised, 4 = Inappropriate
Recommended Combinaons
¹ The indicated paent weight is a guideline only – there may be deviaons.
² To maintain maximum load, li/accessories intended for the same load or more are required.
Recommended combinaons using Liko MasterVest
with Liko sling bars:
Mini 220
Sling bar 350³
Standard 450
Sling bar 450¹
Sling bar 600⁴
Twin bars 670²
MasterVest, XS 112134
MasterVest, S 211134
MasterVest, M 211134
MasterVest, L 2 1 1 1 3 2
MasterVest, XL 3 1 1 1 2 2
MasterVest, XXL 3 2 1 1 2 2
Material: MasterVest is available in Polyester.
© Copyright Liko R&D AB 2020. ALL RIGHTS RESERVED.
Liko AB
Nedre vägen 100
975 92 Luleå, Sweden
+46 (0)920 474700
Liko AB is a subsidiary of Hill-Rom Holdings Inc.
www.hillrom.com
Product Prod. No. Size Body Weight kg¹ Maximum load²
MasterVest Mod. 60 3560113 XS 20-40 kg (44-88 lbs.) 200 kg (440 lbs)
MasterVest Mod. 60 3560114 S40-60 kg (88-132 lbs.) 200 kg (440 lbs)
MasterVest Mod. 60 3560115 M60-80 kg (132-176 lbs.) 200 kg (440 lbs)
MasterVest Mod. 60 3560116 L80-100 kg (176-220 lbs.) 200 kg (440 lbs)
MasterVest Mod. 60 3560117 XL 100-130 kg (220-286 lbs.) 300 kg (660 Ibs.)
MasterVest Mod. 60 3560118 XXL >120 kg (>264 lbs.) 300 kg (660 Ibs.)
MasterVest Mod. 64 3564114 S40-60 kg (88-132 lbs.) 200 kg (440 lbs)
MasterVest Mod. 64 3564115 M60-80 kg (132-176 lbs.) 200 kg (440 lbs)
MasterVest Mod. 64 3564116 L80-100 kg (176-220 lbs.) 200 kg (440 lbs)
MasterVest Mod. 64 3564117 XL 100-130 kg (220-286 lbs.) 200 kg (440 Ibs.)
MasterVest Mod. 64 3564118 XXL >120 kg (>264 lbs.) 200 kg (440 Ibs.)
This manual suits for next models
1
Table of contents
Other Hillrom Sling manuals

Hillrom
Hillrom Liko OriginalSling 10 Manual

Hillrom
Hillrom UniversalSling 000 Manual

Hillrom
Hillrom Liko ComfortSling Plus 300 User manual

Hillrom
Hillrom Liko HygieneVest 55 User manual

Hillrom
Hillrom Liko HygieneSling with SafetyBelt 45 User manual

Hillrom
Hillrom Liko OriginalSling 11 User manual

Hillrom
Hillrom Liko UniversalSling User manual
Popular Sling manuals by other brands

Invacare
Invacare Comfort user manual

Drive DeVilbiss Healthcare
Drive DeVilbiss Healthcare TOILET ACCESS SLING Instructions for use

Guldmann
Guldmann Turner user manual

Care & Independence
Care & Independence Glove HUG user guide

NAUSICAA
NAUSICAA SPECIFIC SLING manual

ERGODYNE
ERGODYNE SQUIDS 3132 quick start guide