By changing some of the function settings (software DIP switches) this product can be used with the following HIOKI instruments.
The following tables show the changes required in the settings.
For details of the method of making the settings,refer to the Instruction Manual for the DPU-414 from Seiko Instruments Inc.
The initial setting is set up in TYPEA.
TYPE A
Adapted Model: 3169-20,3169-21,3167,3268,3286,3286-20,3330,3331,3332,3333,3333-01,3351,DM7275,DM7276
Use these settings.
(1) Software DIP SW1
Switch No. Function ON OFF Print density
(%) Switch No.
1 Input method Parallel Serial 100 678
2 Printing speed High Low OFF ON ON
3 Auto loading ON OFF
4CR function Carriage return and line feed Carriage return
5DIP SW setting command Enable Disable
6 to 8 Printing density See the right table
(2) Software DIP SW2
Switch No. Function ON OFF
1 Printing mode 40 lines 80 lines
2 to 8 It has been set to the DPU-414 default setting.
Please change the printing mode corresponding to Model 3167 or Model 3330 printing item numbers.
Model 3169-20,3169-21,3268,3286,3286-20,3331,3332,3333,3333-01,3351,DM7275 and DM7276 are able to use it
just as the initial state (40 line).
(3) Software DIP SW3
Switch No. Function ON OFF Baud rate (bps) Switch No.
1 Data bit length 8 bit 7 bit 9600 5678
2 Parity permission Without With OFF ON ON ON
3 Parity condition Odd Even
4Flow control H/W BUSY XON/XOFF
5 to 8 Baud rate See the right table
TYPE B
Adapted Model: 3154,3156,3157,3157-01,3237,3238,3239,3443,3504,3504-10,3504-40,3504-50,3504-60,3505,3506,
3511-50,3522-50,3532-50,3532-80,3535,ST5540,ST5541
Use these settings.
(1) Software DIP SW1
Switch No. Function ON OFF
1 Input method Parallel Serial
2 Printing speed High Low
3Auto loading ON OFF
4 CR function Carriage return and line feed Carriage return
5DIP SW setting command Enable Disable
6 to 8 Printing density See the table below
Print density (%) Switch No.
100 6 7 8
OFF ON ON
(2) Software DIP SW2: It has been set to the DPU-414 default setting.
(3) Software DIP SW3
Switch No. Function ON OFF
1 Data bit length 8 bit 7 bit
2 Parity permission Without With
3Parity condition Odd Even
4Flow control H/W BUSY XON/XOFF
5to 8 Baud rate See the table below
Baud rate (bps) Switch No.
19200 5678
OFF ON ON OFF
When connected to the HIOKI Model 3443,change the baud rate to 2400bps.
•Use the HIOKI Model 9443-02 AC Adapter (EU type AC Adapter: PW-C0725-W1-E,Seiko Instruments Inc.) to supply power
to this product.
•HIOKI Model 1196 Recording Paper can be used as the thermal paper. As for the connecting cable,please use the following.
Connecting cable Adapted model
9444 3154,3156,3237,3238,3239,3331,3332,3333,3333-01,3443,3504,3504-10,
3504-40,3504-50,3504-60,3505,3506,3511-50,3535,ST5540,ST5541,DM7275,DM7276
9446 3157,3157-01,3167,3330,3522-50,3532-50,3532-80
9636 3268,3286,3286-20
9721 3169-20,3169-21,3351
21