Installation Instructions for HMI HOYME Adaptor 1103-TW5
24Vac/120Vac Controlled Voltage to Switch 24Vac
1218-ch -1- Printed in Canada
Installation f This Adaptor Shall Be In
Accordance With The Requirements f the
Authorities Having Jurisdiction.
Refer also to H YME Installation Instructions:
Replacement/Ventilation Air Control Damper –
HAC-0x10- PC/P ; ADP-1101-05A; ADP-1102-
TWP, ADP-1103-TWP and ADP-1102-TW5.
ADP-1103-TW5
4” x 5” x 2 1 2”
101 x 127 x 64 mm
This Adaptor ADP-1103-TW5 is an automatic
control switch which is designed but not limited
to accommodate two separate exhaust fans in
a dwelling having one furnace and (if used) a
replacement air damper. A controlled 120Vac
signal from one exhaust fan and or a 24Vac
signal (or dry contacts) from a second exhaust
fan will simultaneously turn on the furnace
circulation fan and open the replacement air
damper. Added is a relay to also open the
damper during furnace firing.
Fitness of this Adaptor/Damper combination,
to satisfy air supply requirements for fuel fired
appliances during operation of the in-
terconnected exhaust fan(s), shall be
investigated by the enforcing authorities.
Air intake duct installation shall be in accordance
with: In Canada - CAN CSA B149 & B139; In the
USA – ANSI NFPA 54, 2006, ANSI Z223.1 and or
local codes including local codes relating to
ventilation air duct installation.
I.D.: ADP-1103-TW5
One Relay DPDT: Relay Coil -120Vac.
One Relay SPDT: Relay Coil - 24Vac.
One Relay DPDT: Relay Coil - 24Vac.
All Contact Points - 24Vac - 5 Amps.
-Adaptor line voltage leads, connected to the
exhaust fan controlled line, shall be suitably
cabled, fastened and enclosed in suitable
raceways.
-Refer to local and applicable codes.
-Always conduct a thorough check-out after
installation is complete.
-Affix appropriate labels and follow instructions
and warnings on each label.
Connecting the Adaptor ADP-1103-TW5 to a
controlled 120Vac Designated Ventilation
Exhaust Fan circuit and heating appliance.
1. Turn off electrical power supply to both the
exhaust fan and furnace circuits.
2. Connect the controlled 120Vac exhaust fan
circuit to the Black and White adaptor leads as
per wiring diagram. Follow applicable codes.
3. Connect Adaptor terminal #5 to the furnace
terminal ‘R’ (24 Vac).
4. (a) Disconnect the thermostat wire ‘G’ (if used)
from the furnace terminal ‘G’ and connect it to
the Adaptor terminal #3(G
T
).
(b) Connect Adaptor terminal #4(G
F
) to the
furnace ‘G’.
5. Turn on the power supply to both the furnace
and to the exhaust fan. Turn on the exhaust fan
which will simultaneously turn on the furnace
circulation fan.
For more information, please contact HMI H YME Manufacturing Inc. 1-800-661-7382
www.hoyme.com
1218-ch -2- Printed in Canada
Connecting an exhaust fan with (a) controlled
2C-24Vac signal or (b) using dry contacts, to
connect to the Adaptor 1103-TW5.
6. Turn off the power supply to both the furnace
and the exhaust fan.
7. (a) Connect the controlled 2C-24Vac signal
from the exhaust fan to Adaptor #6 & #7.
(b) If using dry contacts, connect one wire to
Adaptor terminals #7 and the other wire to
furnace terminal ‘C’, and add a jumper wire
between Adaptor Terminals #5 & #6.
8. Turn on the power supply to both furnace and
exhaust fan. Turn on the exhaust fan which will
simultaneously turn on the furnace circulation fan.
Connecting a replacement fresh air damper (if
used) to open simultaneously with either
exhaust fan running.
9. Turn off the power supply to the furnace.
10. Install a Hoyme ‘HAC’ 2C-24Vac motorized
fresh air control damper to the duct as per
instructions supplied with it. Satisfactory operation
of the damper is recommended before fastening
to the fresh air duct.
(a) For a Power pen damper, connect one
damper wire to Adaptor terminal #1 and connect
the other damper wire to the furnace terminal ‘C’
(b) For a Power Close Damper, connect one
damper wire to Adaptor terminal #2 and connect
the other damper wire to furnace terminal ‘C’.
11. Turn on the power supply to the furnace. If the
damper is a Power pen type, it will remain
closed at this time. If damper is a Power Close
type, it will close at this time.
If the HAC Fresh Air Damper is to also open
during furnace firing:
12. Turn off the main power to the furnace and
connect Adaptor terminal #9 to Furnace (W)
and connect Adaptor terminal #8 to furnace (C)
or to furnace ground screw.
13. Turn power on to the furnace and turn the
thermostat for the furnace to fire. Damper will
open during the firing cycle of the furnace and will
close to save energy when the furnace fire stops.
Schematic Wiring Diagram of Adaptor
ADP-1103-TW5
Note:
This marking is also on label to be affixed adjacent to
appliance wiring diagram.
Additional wire shall be of the same size as originally used
when completing electric circuits.

Other HMI HOYME Receiver manuals

HMI HOYME ADP-1103-TWP User manual

HMI HOYME

HMI HOYME ADP-1103-TWP User manual

HMI HOYME TMADP-0240-3WS User manual

HMI HOYME

HMI HOYME TMADP-0240-3WS User manual

HMI HOYME ADP-1102-S5A User manual

HMI HOYME

HMI HOYME ADP-1102-S5A User manual

Popular Receiver manuals by other brands

ADEMCO 4281 Series installation instructions

ADEMCO

ADEMCO 4281 Series installation instructions

Aiwa FR-A275 operating instructions

Aiwa

Aiwa FR-A275 operating instructions

Yamaha R-N402 owner's manual

Yamaha

Yamaha R-N402 owner's manual

Onkyo TX-SE500 instruction manual

Onkyo

Onkyo TX-SE500 instruction manual

CYP CH-2540RX Operation manual

CYP

CYP CH-2540RX Operation manual

Microwave Radio Communications DAR Plus Operator's guide

Microwave Radio Communications

Microwave Radio Communications DAR Plus Operator's guide

TELECO AUTOMATION TRPRD868G01T quick start guide

TELECO AUTOMATION

TELECO AUTOMATION TRPRD868G01T quick start guide

Marantz SR6007 specification

Marantz

Marantz SR6007 specification

Sony STR-DA3400ES manual

Sony

Sony STR-DA3400ES manual

Roku HD1000 - PhotoBridge - Digital AV Player Installation and use manual

Roku

Roku HD1000 - PhotoBridge - Digital AV Player Installation and use manual

Spektrum SPMSRS4210 instruction manual

Spektrum

Spektrum SPMSRS4210 instruction manual

PEHA 454 FU-E REG Installation and operating instructions

PEHA

PEHA 454 FU-E REG Installation and operating instructions

Leica GMX902 GG user manual

Leica

Leica GMX902 GG user manual

Audio enhancement K-SRC14 manual

Audio enhancement

Audio enhancement K-SRC14 manual

Bosch Radion B810 reference guide

Bosch

Bosch Radion B810 reference guide

Sony STR-DH740 Quick setup guide

Sony

Sony STR-DH740 Quick setup guide

Yamaha R-V1103 owner's manual

Yamaha

Yamaha R-V1103 owner's manual

Denon AVR-E200 Service manual

Denon

Denon AVR-E200 Service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.