DeLeon®TL
•Cast Aluminum/Polycarbonate
Construction
•Emergency or AC Only Operation
•LED Illumination
•Vandal Resistant
General Description
Holophane’s LNTLL wet location and harsh
environment exit combines rugged construction
and appealing aesthetics. Durable cast
aluminum and polycarbonate housing
construction, standard vandal resistant/
anti-corrosion coated hardware and high-
performance electronics ensures long lasting
reliability even in the most severe environments.
The LNTLL is UL listed for use in wet/damp
location applications ranging from -40ºF (-40ºC)
to 113ºF (45ºC). Testing of emergency
operation is performed using an
ordinary pen laser allowing the unit to be
mounted almost anywhere. LNTLL exits are
shipped with field-selectable chevrons, and can
be ordered as a single face or universal (single/
double) face configuration. Three color choices
are available and stencils may be
ordered painted to match or in an attractively
contrasting brushed aluminum finish.
HousinG
Die-cast aluminum housing with premium
impact resistant injection molded polycarbonate
cover. A groove molded into each cover accepts
a full perimeter silicone rubber gasket.
Housing is powder coated in white, black or
gray. On single face units the back cover is
molded in color to match and the front cover is
clear. Universal models consist of 2 faces,
backplate and canopy.
Stencil is stamped aluminum with field-
selectable chevrons and is contained inside the
fully gasketed housing for corrosion protection.
Stencil is available painted to match housing or
with brushed finish.
All exposed hardware is both vandal resistant
and anti-corrosion coated.
Universal knockouts on backplate allow wall
mounting directly to standard junction boxes.
Die-cast aluminum canopy is provided for top/
side mounting and is powder coated to match
housing.
illumination
Illumination of the exit stencil face is
accomplished with long lasting, high output
Light Emitting Diodes (LEDs). Hot spots and
striations are eliminated by the internal light
chamber, which is specially designed around
the high performance LED array.
installation
Exit installation methods include top and end
canopy mount and back wall mount. All
mounting configuration employ neoprene
gaskets between exit housing, canopy and
mounting surface. The exit is designed to
mount to standard 3-1/2” and 4”
junction boxes. Provisions in the cast frame
allow for up to two ½” flex or rigid conduit
points.
electronics
AC Only Operation Units
Dual voltage 120/277 VAC input with surge
protection is standard.
Emergency Operation Units
Dual voltage 120/277 VAC input with solid
state circuitry provides for a reliable charging
system.
All components are located within the exit
housing.
An indicator light is located on the face of the
unit to signify that AC utility is present.
AC lockout prevents battery drain prior to the
initial energizing of utility power. The low
voltage disconnect (LVD) feature will disconnect
the battery prior to an unacceptable deep
discharge, but not before the required 120 min-
ute emergency operation.
The brownout protection circuitry will auto-
matically switch the unit into the emergency
mode if the utility voltage drops below 20% of
nominal.
Battery charging circuitry is entirely solid-state
and of a constant current design. Battery re-
charge time after a complete discharge is less
than the required UL 924 standard.
Solid-state circuitry causes an instantaneous
transfer to battery power if either the loss of
AC utility or a brownout condition is detected.
When line voltage is present and stabilized, the
transfer circuitry switches back to normal
operation and begins recharging the battery.
The transfer circuitry can be tested by using an
ordinary pen laser to trigger the laser detector
located on the face. A manual test switch is
also provided inside the housing.
intellicHarGe self-testinG
DiaGnostics (stanDarD)
Checks charger, LEDs, battery and transformer
every five seconds.
Automatic tests include: one minute test once
a month, and 30-minute test every 6 months.
Coded LED flash signifies fault type.
Battery
A maintenance free, sealed nickel cadmium
battery is standard. Construction is of the
sintered plate design and the battery assembly
is equipped with a quick connect plug assembly
for easy installation.
Standard sustained emergency operation is for
120 minutes with the LED illumination source
providing full light output.
The approved operating temperature range
of -40ºF (-40ºC) to 113ºF (45ºC) provides a typi-
cal life of up to 10 years.
electrical specifications
AC Only Operation
Input Power Requirements
Red – 3.8 watts (120 VAC), PF = 0.96
3.8 watts (277 VAC), PF = 0.91
Green – 4.0 watts (120 VAC), PF = 0.95
4.0 watts (277 VAC), PF = 0.90
Emergency Operation
Input Power Requirements
Red – 4.7 watts (120 VAC), PF = 0.95
4.8 watts (277 VAC), PF = 0.97
Green – 4.7 watts (120 VAC), PF = 0.95
4.7 watts (277 VAC), PF = 0.99
listinGs
The LNTLLL exit meets or exceeds all perfor-
mance standards for operation in wet location
environments as required by UL 924.
NEC, BOCA and OSHA illumination standard.
Meets ADA specifications for wall mounted
lighting fixtures.
HL-2380 Rev. 5/2/13
Wet/Damp Location Exits Exits
Warranty
5-year limited warranty.
Complete warranty terms located at:
www.acuitybrands.com/CustomerRe-
sources/Terms_and_conditions.aspx
Actual performance may differ as a result of end-
user environment and application.
Note: Specifications are subject to change with-
out notice.
Dimensions
®
DeLeon®TL
Ordering Data How to construct a catalog number
Example: LNTLLL AM W SR S PM
suGGesteD specification
Furnish and install Holophane’s LED exit sign model
________________________. The exit shall be
constructed to meet Underwriter’s Laboratories,
Inc. Standard #924 and the National Electrical Code
(NEC).
Installation and Operation
Exit shall be easily field connected to a 120 or 277
VAC, 60 hertz, unswitched power source. Installation
must comply with the NEC as well as other applicable
codes. (Emergency operation only) – Upon utility
power failure or brown out, the unit shall
automatically transfer to battery power and maintain
the required illumination level for a minimum period
of 120 minutes. Upon restoration of utility power,
the charger shall restore the battery to full charge
within UL 924 requirements following a rated
discharge of not more than 120 minutes. Monthly
testing shall be performed by a means of a pen laser
with a range of 20’ with product 8’ AFF.
Charger (Emergency operation only)
Product shall utilize a constant current charging
system which will maintain the battery at full capacity
without the need of periodic exercising or equalization.
The following features shall be standard: low
voltage disconnect (LVD), brownout protection and
AC lockout. Five year warranty provided.
Battery (Emergency operation only)
The battery shall be maintenance free, sealed nickel
cadmium utilizing sintered plate construction and
polypropylene separators for trouble-free operation in
ambient temperatures up to 113ºF (45ºC).
Illumination
The LNTLL wet location LED exit sign shall incorporate
high intensity LEDs. The LEDs shall be designed so
that the unlikely failure of the LED will not affect the
integrity of the total sign in the emergency mode.
The LNTLL exit equipped with red LEDs shall consume
3.73 watts (120 VAC version) or 4.30 watts (120 VAC
Emergency version). The LNTLL exit equipped with
green LEDs shall consume 2.82 watts (120 VAC
version) or 3.40 watts (120 VAC Emergency version).
Housing
The exit sign housing shall be constructed of a
combination of heavy-duty die-cast aluminum and
injection molded polycarbonate. The final housing
finish shall be an epoxy-based powder-coat paint.
THe exit stencil face shall be constructed of aluminum
sheet and shall be available in matching painted or
brushed finish. Chevron selection shall be field
selectable using knockouts in the stencil.
Operation
AM AC only, multi-voltage
120/277V dual voltage
input
NC Nickel cadmium
emergency
120/277 input
Housing and Stencil Color
WWhite housing, white stencil
GGray housing, gray stencil
BBlack housing, black stencil
WA White housing, brushed
aluminum stencil
BA Black housing, brushed
aluminum stencil
GA Gray housing, brushed
aluminum stencil
Letter/Face Color
SR Gray stencil face, red LED’s
SG Gray stencil face, green LED’s
Number of Faces
S Single
U Double Face
Universal
LNTLL AM W SR S
Options (Factory installed)
C1 120V, 2 circuit input (Not available with
NC Operation)
C2 277V, 2 circuit input (Not available with
NC Operation)
BF Buzzer/flasher (EM units only)
BZ DC buzzer
PM1 Pendant mount (requires pendant kit)
SW2Special wording
FFire alarm interface (24V)
FL Emergency flasher
PM
Accessories (Shipped separately)
HPT15PTOOL Tamper-proof tool
HPTPKITB1Pendant kit, 12” black stem
HPTPKITW1Pendant kit, 12” white stem
HPWG4 Wall mount wire guard
HPWG10 Side mount wire guard
1 Must specify “PM” option for compatibility
with pendant kit. Consult TSG for additional
length cost
2 Artwork setup charge reflects costs of single
face, one color setup. Consult TSG for multiple
color setup cost
Series
LNTLL1, 2 DeLeon
Wet/Damp
Locations
Exit
1 All TLL Series exits
include tamper-proof
hardware
2 UL Wet Location listing
is standard
Wet/Damp Location Exits Exits
Weight: Single face: 3.17 kg. (7 lbs.)
Double face: 3.63 kg. (8 lbs.)
Acuity Brands Lighting, Inc.
Holophane Headquarters, 3825 Columbus Road,
Granville, OH 43023
Holophane Canada, Inc. 9040 Leslie Street,
Suite 208, Richmond Hill, ON L4B 3M4
Holophane Europe Limited, Bond Ave.,
Milton Keynes MK1 1JG, England
Holophane, S.A. de C.V., Apartado Postal No. 986,
Naucalpan de Juarez, 53000 Edo. de Mexico
Contact your local Holophane factory sales representative
for application assistance, and computer-aided design and cost
studies. For information on other Holophane products and
systems, call the Inside Sales Service Department at 740-345-9631.
In Canada call 905-866-8967.
Luminaires may utilize fluorescent or high intensity discharge
sources that contain small amounts of mercury. New disposal
labeling for these lamps includes the mercury identifier shown on
the left to indicate that the lamp contains mercury and should be
disposed of in accordance with local requirements.
Information sources regarding lamp recycling and disposal are included on
the packaging of most mercury-containing lamps and also can be located at
www.lamprecycle.org.
HL-2380 Rev. 5/2/13
©2011-2013 Acuity Brands Lighting, Inc. All Rights Reserved.
Visit our web site at www.holophane.com

This manual suits for next models

1

Popular Security Sensor manuals by other brands

C-LOGIC 630-MD instruction manual

C-LOGIC

C-LOGIC 630-MD instruction manual

Safescan 40H manual

Safescan

Safescan 40H manual

Z-Wave SM103 manual

Z-Wave

Z-Wave SM103 manual

System Sensor B501BI-IV Installation and maintenance instructions

System Sensor

System Sensor B501BI-IV Installation and maintenance instructions

Bacharach H25-IR PRO user manual

Bacharach

Bacharach H25-IR PRO user manual

EDELRID Shark Soft manual

EDELRID

EDELRID Shark Soft manual

Bosch Blue Line Q1 installation instructions

Bosch

Bosch Blue Line Q1 installation instructions

GE DD205RF/60-947-8A Series installation instructions

GE

GE DD205RF/60-947-8A Series installation instructions

RKI Instruments 82-5221 Operator's manual

RKI Instruments

RKI Instruments 82-5221 Operator's manual

Siemens 5TC1585 operating instructions

Siemens

Siemens 5TC1585 operating instructions

Tyco Visonic TOWER-30AM PG2 installation instructions

Tyco

Tyco Visonic TOWER-30AM PG2 installation instructions

DANLERS CBU-HBSP Installation

DANLERS

DANLERS CBU-HBSP Installation

Evikon PluraSens E2608-NH3-E user manual

Evikon

Evikon PluraSens E2608-NH3-E user manual

LEGRAND tynetec ZXT815 quick start guide

LEGRAND

LEGRAND tynetec ZXT815 quick start guide

walraven Pacifyre EFC Assembly instructions

walraven

walraven Pacifyre EFC Assembly instructions

Potter PAD200-DUCT installation manual

Potter

Potter PAD200-DUCT installation manual

Notifier 30-2021-24 manual

Notifier

Notifier 30-2021-24 manual

BW Technologies GasAlertClip Extreme SO2 instruction sheet

BW Technologies

BW Technologies GasAlertClip Extreme SO2 instruction sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.