manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. HELVAR
  6. •
  7. Security Sensor
  8. •
  9. HELVAR Digidim 313 User manual

HELVAR Digidim 313 User manual

1
Helvar | Data is subject to change without notice. www.helvar.com
Features and Connections
DALI connection
The DALI connection is made via DA+ and DA– terminals.
The DALI input is not polarity sensitive (unless you are
using an external power supply).
Optional connection to external power
12 V to 24 V. See ‘External Power Supply (Optional)’ on page 3.
– Microwave sensors
– IR receiver
– Status LEDs
Mounting bezel
Retaining spring
Retaining spring
DALI +
DALI
-
+
-
The Low-Profile Microwave Detector provides occupancy detection for the automatic control of DALI lighting loads.
The unit can also be controlled using a Helvar infrared remote handset, such as the 303 DIGIDIM Infrared Remote Control.
Helvar’s 313 detects movement using its highly sensitive microwave detector. It works by emitting low-power microwave
signals and measuring the reflections as the signals bounce off moving objects.
When an area is no longer occupied, the load will switch off after a certain time. This time-out period is configured using
Helvar’s lighting system design and control software: Designer, or Toolbox.
313, 313B Low-Profile Microwave Detector
Installation Guide
Microwave sensor
Detects movement within the detection range allowing load
control in response to changes in room occupancy.
IR Receiver
Receives control and programming commands from a Helvar
infrared remote handset (available separately).
Status LED
The red LED flashes to indicate the following:
Valid setting received
Identify active
R
RRRRRR
R
= Red LED
Detection Pattern
12 m – 16 m
2.8 m
Sensitivity set to maximum
2Helvar 313 Low-Profile Microwave Detector: Installation Guide
60 mm
50 mm
76 mm
Ø5
65 mm
Ø76
Connection and Fixing
Mounting hole Surface Back Box SBB-A, SBB-AB
1.
2.
3.
4.
Attach
the cable
clamp.
If required,
connect
theexternal
power cable.
Ø68 mm
WARNING
Take special care
when bending springs
to install the unit.
Note: Order the SBB-A or SBB-AB surface mount boxes separately.
• Position the sensor so that the occupants of the room are normally inside the detection zone.
• Do not install the sensor within 1 m of any lighting, forced air heating, or ventilation equipment.
• Do not fix the sensor to an unstable or vibrating surface.
• Install the unit as far away as possible from the surface of metal objects.
• The detection pattern illustrated (see ‘Detection Pattern’ on page 1) is based on a mounting height of 2.8 m.
A lower mounting height will decrease the overall size of the detection zone.
Installation Notes
Installation
All dimensions in millimetres.
1. Install the unit: see ‘Connection and Fixing’ on page 2.
2a. Connect the DALI terminal blocks to the sockets located at the rear of the sensor.
2b. If required, connect the optional power supply. See ‘External Power Supply (Optional)’ on page 3.
3. Power the unit up.
4. After the lighting load switches on, by default it will switch off after 20 minutes of no movement detected.
3
Helvar | Data is subject to change without notice. www.helvar.com
You can use a Helvar infrared remote handset,
such as the 303 DIGIDIM Infrared Remote Control,
to send signals to the 313 Detector to:
– Recall lighting scenes 1–4.
– Adjust light levels.
– Store current level.
– Install preset levels for scenes 1–4.
Remote Control
Other Functions
Sensitivity
Adjust the sensitivity using Designer, or Toolbox (Helvar’s lighting system design and control software).
Note: On maximum sensitivity, the detector unit is extremely sensitive to movement and may detect through glass, thin walls or
partitions. If this causes a problem, reduce its sensitivity.
Adjusting On, Exit and Transition Time-Outs
The default time-outs for On, Exit and Transition can be altered using Designer, or Toolbox.
Check Connection to DALI Network
To make sure that the sensor is correctly connected the DALI network, use the Identify function in Designer, or Toolbox.
Using Designer and Toolbox Software
When using Designer, connect the PC to the lighting network via a Helvar router.
When using Toolbox, connect the PC to the lighting network via a Helvar serial or USB interface.
For information about Designer and Toolbox, visit www.helvar.com.
303 DIGIDIM Infrared Remote Control
For details, see the 303 Installation and
User Guide.
External Power Supply (Optional)
The following table gives the various 12 V to 24 V external power supply units that can be used,
as well as the sensor hardware revision needed for each of them. With some models, you must
make a wire link between the DALI negative terminal and the negative terminal of the external
power supply, as shown in the figure.
EPS Current
limited
Link from
DA– to EPS–
Sensor hardware
revision
Helvar 401 Yes No Any
Helvar 402 Yes Yes Any
Helvar 403 Yes No Any
Helvar
LL1x30-E-CV24 Slow No 4 or later
Generic
12 V to 24 V No No* 4 or later
* Except in some cases where the generic EPS output is referenced to earth.
+
-
+
-
DALI
4Helvar 313 Low-Profile Microwave Detector: Installation Guide
Dimensions
Technical Data
68
ø
76
58
3.7 3.6
61.2
Connections
External power / DALI: Removable terminal block
Wire section: 0.5 mm² –2.5mm²
solid or stranded
Cable rating: All cables must be mains rated.
Power
DALI supply input: 13 V to 22.5 V
DALI consumption: 20 mA
Note: DALI consumption is less
than 2 mA when external power is
supplied to the unit.
(Optional) External power: 12 V to 24 V; 0.3 W
Remote control functions
Use Helvar infrared
remote handset to:
– Recall lighting scenes 1–4.
– Adjust light levels.
–Store current level.
– Install preset levels for
scenes1–4.
Note: Adjust sensitivity using
Designer, or Toolbox (not by
remote control unit).
Factory setting for sensor
sensitivity: 9 (maximum).
Microwave operating frequency
Frequency: 5.8 GHz
Mechanical data
Mounting hole diameter: 68 mm
Bezel diameter: 76 mm
Recommended
clearancedepth
(incl.50mm for cabling):
80 mm (without protective cover)
100 mm (with protective cover)
Material (casing): Flame retardant ABS and PC/ABS
Finish/Colour: 313: Matt / White RAL 9003
313B:Matt / Anthracite Grey RAL 7016
Weight: 90 g
IP code: IP30
Operating conditions
Ambient temperature: 0 °C to +50 °C
Relative humidity: Max. 90 %, noncondensing
Storage temperature: −10 °C to +70 °C
Conformity and standards
EMC emission: EN 61000-6-1
EMC immunity: EN 61000-6-3
Safety: EN 60730-1
Environment: Complies with WEEE and RoHS
directives.
Version information
Software version: 6
Hardware version: Rev. 4
Software compatibility
Designer: 4.1 or later
Toolbox: 2.2.16 or later
Helvar Ltd
Hawley Mill
Hawley Road
DARTFORD
DA2 7SY
UNITED KINGDOM
www.helvar.com
Doc. 7860268, issue 9, 2020-01-08

This manual suits for next models

3

Other HELVAR Security Sensor manuals

HELVAR digidim 317 User manual

HELVAR

HELVAR digidim 317 User manual

HELVAR digidim 314 User manual

HELVAR

HELVAR digidim 314 User manual

HELVAR 314 Tilting User manual

HELVAR

HELVAR 314 Tilting User manual

HELVAR OB-1501 User manual

HELVAR

HELVAR OB-1501 User manual

HELVAR Digidim 317 User manual

HELVAR

HELVAR Digidim 317 User manual

HELVAR 311 User manual

HELVAR

HELVAR 311 User manual

HELVAR digidim 313 User manual

HELVAR

HELVAR digidim 313 User manual

HELVAR Digidim 311 User manual

HELVAR

HELVAR Digidim 311 User manual

HELVAR 318 User manual

HELVAR

HELVAR 318 User manual

HELVAR digidim 319 User manual

HELVAR

HELVAR digidim 319 User manual

Popular Security Sensor manuals by other brands

B.E.G. LUXOMAT PD4-S Series Installation and operating instruction

B.E.G.

B.E.G. LUXOMAT PD4-S Series Installation and operating instruction

Omron F3SJ-B**P25 Series instruction sheet

Omron

Omron F3SJ-B**P25 Series instruction sheet

WiT BWT61CL user manual

WiT

WiT BWT61CL user manual

DeFelsko PosiTest HHD Addendum to instruction manual

DeFelsko

DeFelsko PosiTest HHD Addendum to instruction manual

Vive LVA1055 user manual

Vive

Vive LVA1055 user manual

Banner L-GAGE LTF12 instruction manual

Banner

Banner L-GAGE LTF12 instruction manual

Karassn KS-318DCT user manual

Karassn

Karassn KS-318DCT user manual

FGD FlameSpec UV-IR user manual

FGD

FGD FlameSpec UV-IR user manual

General Monitors TL104 instruction manual

General Monitors

General Monitors TL104 instruction manual

NEW TRIBE AERO HUNTER User instructions

NEW TRIBE

NEW TRIBE AERO HUNTER User instructions

Metasys 2451 quick start guide

Metasys

Metasys 2451 quick start guide

AUS PRO CL-200E user manual

AUS

AUS PRO CL-200E user manual

PCB 2301-02A Installation and operating manual

PCB

PCB 2301-02A Installation and operating manual

Optex InSight INS-QXI-ST installation instructions

Optex

Optex InSight INS-QXI-ST installation instructions

RIDGID NaviTrack Battery Sonde instructions

RIDGID

RIDGID NaviTrack Battery Sonde instructions

Johnson Controls LC-224 manual

Johnson Controls

Johnson Controls LC-224 manual

hager TX511 User instructions

hager

hager TX511 User instructions

Kistler 9329A instruction manual

Kistler

Kistler 9329A instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.