Homefront RF-360T User manual

1
RF-360T
2
General Information About Your New Dual Detector Smoke Alarm ............ page 3
Contents of your Kit ................................................................................... page 4
Recommended Locations for Your Smoke Alarm ........................................ page 5
Areas Not Appropriate for Smoke Alarms .................................................. page 6
National Fire Protection Association Standards .......................................... page 7
Complete Home Fire Protection ................................................................. page 8
Acceptable interLINX Alarm Spacing .......................................................... page 8
Alarm Features and Functions.............................................................. page 9 - 10
Creating Your interLINX Network .............................................................. page 11
Adding an Alarm to Your interLINX Network............................................. page 12
Removing an Alarm from Your interLINX Network.................................... page 13
Choosing the Mounting Location in a Room ............................................ page 14
How to Mount the Battery Powered Smoke Alarm ............................ page 15 - 16
How to Wire and Mount the AC Powered Alarm ...................................... page 17
Cleaning the Alarm ................................................................................... page 18
Alarm Specifications ................................................................................. page 19
Important Fire Safety Information ............................................................ page 20
Warning! Limitations on Smoke Alarms .................................................... page 21
Limited Warranty ...................................................................................... page 22
Replacement Guarantees .......................................................................... page 23
Homefront recommends a combination of early-detecting Smoke Alarms
and reliable Heat Alarms installed in their appropriate locations throughout
the home.
Heat and Smoke Alarms are not a substitute for an adequate homeowner’s
fire insurance policy.
Table of Contents

3
What Makes the Homefront Alarm Different?
About Your New Dual Sensor Photoelectric Smoke Alarm
Thank you for purchasing the Homefront Smoke Alarm. The smoke alarm plays
an important role in protecting your family and home from the dangers of
fire. Please carefully read and follow the information in this booklet to ensure
that your Alarm operates properly and is located in the areas best suited for
activation.
Illuminated status
icons for Power,
Warning, Low Battery,
and Fire
Two modes of electronic
temperature sensing for a
very fast response Dual functioning Test
and Silence button
Easy to access and
clean smoke chamber
and bug screen Attractive and durable
materials for a sturdy,
high-quality alarm
4
AC
Version
Only
Contents of Your Kit
Please make sure the following is included in your kit:
Alarm
Batteries
(4 pack)
Instruction
Manual
Mounting Bracket
Wire Harness
Wire Nuts
Key Features
The latest photoelectric smoke sensing technology.
Electronic temperature sensing with Rate of Rise and Fixed Temperature triggers.
Radio communication to connect all RF360T alarms into their own Home Network.
Powered by easily available AA alkaline batteries.
Easy maintenance with separable sections and removable bug screen.
Four illuminated icons to demonstrate alarm status.
Multi-function button to allow for testing and silencing of unwanted triggering.
Uniquely loud horn to notify occupants of fire danger.
Top quality construction to ensure beautiful appearance and durability.
Battery
Version
Only
Plastic Anchors (2)
1” Screws (2)

5
Bedrooms. A major threat from fire occurs
at night when people are sleeping. Smoke
alarms are required protection in all sleeping
rooms.
Living Rooms. To enhance safety, a smoke
alarm should be located in the living room of
a home.
Recommended Locations for your Smoke Alarm
Recreation and Dining Rooms. For
additional protection, a smoke alarm should
be located in the other living spaces of the
home.
Hallways. A principal threat to people
sleeping in bedrooms comes from fires
elsewhere in the home. A smoke alarm
is required to be located outside of each
sleeping area, and on every level of the home.
Basements. A smoke alarm is required
on every level of the house, including the
basement and in living areas of guest suites.
6
Areas Not Appropriate for Smoke Alarms
Kitchens. Do not install near kitchen
appliances. Steam and by-products of
cooking might cause nuisance alarms.
Garages. Do not install in garages.
Exhaust gases from vehicles can trigger
the smoke alarm.
Attics. Do not install in attics. A
smoke alarm can be affected by dust,
small insects or high temperatures. Do
not install the alarm in areas where
the normal ambient temperature can
exceed 100°F (38°C).
Utility and Furnace Rooms. Do not
install close to equipment that can create
steam and gas. This steam and gas can
trigger the smoke alarm.

7
National Fire Protection Association Standards
This equipment should be installed in accordance with the National Fire
Protection Association’s Standard 72 (National Fire Protection Association,
Batterymarch Park, Quincy, MA 02269).
For your information, the National Fire Protection Association’s Standard 72,
2010 Edition, Section 29.5.1 covering required protection in One- and Two-
Family Dwelling Units, reads as follows:
29.5.1.1 Required Detection. Where required by other governing laws, codes,
or standards for a specific type of occupancy, approved single- and multiple-
station smoke alarms shall be installed as follows:
(1) In all sleeping rooms and guest rooms
(2) Outside each separate dwelling unit sleeping area, within 21 ft (6.4 m) of
any door to a sleeping room, with the distance measured along a path
of travel
(3) On every level of the dwelling unit, including basements
(4) On every level of a residential board and care occupancy (small facility),
including basements and excluding crawl spaces and unfinished attics.
(5) In the living area(s) of a guest suite
(6) In the living areas(s) of a residential board and care occupancy (small
facility)
A.11.8.3 (NFPA 72 2002 Edition) Are More Smoke Detectors Desirable?
The required number of smoke detectors might not provide reliable early
warning protection for those areas separated by a door from the areas protected
by the required smoke detectors. For this reason, it is recommended that the
householder consider the use of additional smoke detectors for those areas for
increased protection. The additional areas include the basement, bedrooms,
dining room, furnance room, utility room, and hallways not protected by the
required smoke detectors. The installation of smoke detectors in kitchens,
attics (finished or unfinished), or garages is not normally recommended as
these locations occasionally experience conditions that can result in improper
operation.
Note: Applicable building codes or other local laws may require the installation
of additional fire alarms in addition to the minimum recommended by the NFPA.
8
Complete Home Fire Protection
Single Story Homes Two Story Homes
Key
NFPA Minimum Req’d Smoke Alarms in New Construction
Recommended Heat Alarm locations
Interconnections
Attic
Kitchen Living
Room
Bedroom Hall Bedroom
Crawl Space
Attic
Bedroom BedroomHall
Living Room Kitchen
Utility RoomBasement
Acceptable interLINX Alarm Spacing
Each alarm will also act as a repeating
station, so any signal received by an alarm
will be rebroadcast.
After final installation, test all alarms
for proper interLINX radio connection.
Just press the test button of an alarm
while having a helper observe the
remote alarms.
Maximum
Spacing in
Open Area
100’ (30.5 m)
The interLINX network communicates using
radio frequency. The range of the radio has
been tested to 100 feet (30.5 m) in open area
distance testing.
Homefront recommends complete home fire protection. This can be achieved by
installing a combination of Smoke and Heat Alarms in their appropriate locations
in every room of the house.

9
Alarm Features and Functions
Power Indicator Light
On Model RF-360TB (Battery-Only powered),
the POWER icon will briefly flash once per
minute.
On Model RF-360TEB (AC with Battery Back-
up), the POWER icon will run continuously
while AC powered.
BATTERY will flash once per minute
accompanied by the horn chirp to indicate the
batteries must be replaced.
Replace batteries only with Energizer
E91 AA batteries.
Low Battery Warning Light
Warning/Trouble Light
WARNING will flash once per second to indicate
that the interLINX network is open to accept new
alarms.
WARNING can also indicate a problem with
the alarm’s smoke sensitivity. In this case,
the WARNING light will flash once per minute
accompanied by the horn chirp.
If this occurs, clean the alarm (as described in
this manual)
FIRE will flash when alarm detects sufficient
smoke or heat. This is accompanied by the
sounding of the horn.
FIRE will stay on continuously if the alarm was
triggered remotely by another alarm on the
interLINX network.
Fire Warning Light
10
Silencing Nuisance Alarms
Alarm Features and Functions
Testing the Alarm
Every alarm should be tested weekly to ensure proper operation.
To test the alarm, press and release the button on
the front face.
The alarm will sound with 3 or 4 beeps and FIRE will
flash rapidly.
All four icons will strobe to indicate proper function.
The alarm will then send out a network test comand
and all other alarms on the network will perform the
steps above.
If the alarm fails, the horn will sound. Clean the
alarm (as described in this manual) and retest. If the
alarm still fails, contact the manufacturer.
The Homefront family of alarms is equipped with a silence feature that will
decrease the sensitity of the alarm and silence nuisance alarms.
If in the course of normal activity, cooking smoke,
steam or other gases cause the alarm to activate,
the alarm can be silenced for ten minutes by
pressing the button on the front face of the
alarm.
The silence feature will also silence any alarms
that were triggered remotely. However, the
initiating alarm must be silenced directly.
If the quantity of smoke is too great, the
alarm will not silence until the air has
cleared sufficiently.

11
Creating Your interLINX Network
The Homefront alarm communicates on its own private interLINX Network. This
network is created simply by powering up new alarms one at a time.
General Note: The interLINX network is limited
to 18 total units. Only 12 of these units may be
smoke alarms.
The WARNING light will begin to flash slowly.
While the WARNING light is flashing at this rate,
additional alarms may be added to your network.
Install (4) AA batteries into the next alarm.
After a few seconds, the alarm will chirp twice
and all four of the lighted icons will strobe on.
This alarm has been added to
your network!
Install the 4 AA batteries into the first alarm.
One minute after installing the last set of
batteries, the WARNING light will stop flashing
on the original alarm, and it will join the network.
The network is now closed.
Continue installing batteries to each new alarm,
one alarm at a time, until all alarms have been
added to the network.
12
3
4
General Note: It is easiest to first create the
interLINX network while all alarms are located
together, such as on a table.
12
Adding an Alarm to Your interLINX Network
12
3
4
In the event that an alarm must be added to the interLINX network after it has
closed, the following steps must be taken to reopen the network.
Select any alarm on the existing network. Press and
hold the button on the front cover of the alarm.
The FIRE light will flash rapidly and the alarm will
sound three tones.
Continue holding the button down.
Next, the WARNING light will begin to flash.
Count 5 flashes of the WARNING light and
release the button.
The WARNING light will now slowly pulse,
signaling the network is again ready to receive
alarms.
Install batteries into the new alarm being added to
the network.
After a few seconds the alarm will chirp twice and
all four of the lighted icons will strobe on.
After one minute, the WARNING light will stop
flashing on the original alarm and the network
will close.
The alarm has been successfully added to
your network!

13
Removing an Alarm from Your interLINX Network
In the event that an alarm must be removed from your interLINX network, the
following steps must be taken.
Press and hold the button on the front cover of
the alarm. The FIRE light will flash rapidly and
the alarm will sound three tones.
Continue holding the button down.
Next, the WARNING light will begin to flash.
Count 10 flashes of the WARNING light and
release the button.
The alarm will chirp twice and all four of the
lighted icons will strobe on.
The alarm has been removed from
the network.
Reset the alarm by removing the (4) AA batteries
and immediately re-installing them.
After a few seconds the alarm will chirp twice and
all four of the lighted icons will strobe on.
After one minutes, the WARNING light will stop
flashing and the alarm will function as a stand-
alone unit.
12
3
4
14
4” (10cm) 4”
12” (30cm)
Choosing the Mounting Location in a Room
BEST
Center on ceiling.
ACCEPTABLE
On ceiling, at least 4” (10cm) from intersection
with wall.
ACCEPTABLE
On wall, at least 4” (10cm) from ceiling, and
within 16” (41cm) of intersection with ceiling (if
local codes permit wall mounting).
ACCEPTABLE
On peaked ceilings or roofs, mount at least 4”
(10cm) from the upper corner, but high enough to
allow a maximum of 36” (91cm) of horizontal air
space as measured off the peak.
4” (10cm)
36” (91cm) 36” (91cm)
ACCEPTABLE
On sloped ceilings, at least 4” (10cm) from the up-
per corner, but high enough to allow a maximum
of 36” (91cm) of horizontal air space as measured
off the peak.
36” (91cm)
4” (10cm)
OK
Install on exposed face of joist or rafter.
NO!
Do not install between joists or rafters.
Do not mount Alarm between joists or rafters;
mount on the exposed surface of the joist.

15
How to Mount the Battery Powered Alarm
1Mark
Place the mounting bracket against the
ceiling or wall, and using the mount-
ing bracket as a template, mark the
top and bottom holes with a pencil.
2Drill
Using a 1/8” (3mm) drill bit, drill
two pilot holes in the center of the
two marked hole locations. This will
determine if a wood beam or stud is
present.
3 Fasten Bracket
Situation A: Wood
If wood is present behind the drywall,
securely fasten the mounting bracket
to the wall using the two 1” screws.
1/8” (3mm) drill bit
Wood
Drywall
Mounting Bracket
1” Screws
If installing an AC powered alarm,
with the electrical power off to the
line, simply attach the bracket to the
electrical box with the existing screws.
See wiring diagram in this manual for
connection information.
16
How to Mount the Battery Powered Alarm
Drywall
Plastic Anchors
Mounting Bracket
1” Screws
Situation B: No Wood
If no wood is present, use a Phillips
screwdriver to screw the two plastic
wall anchors into the pre-drilled holes
until fully seated. Then secure the
mounting bracket to the wall anchors
using the two 1” screws.
Situation C: Combination
Where there is no wood present, first
screw the plastic wall anchor into
the pre-drilled hole using a Phillips
screwdriver.
Then secure the mounting bracket in
place using the two 1” screws.
Drywall
Plastic Anchors
Mounting Bracket
1” Screws
Wood
4Lock Into Place
With the batteries installed and the
alarms fully networked together,
position the Smoke Alarm onto
the center of the bracket and turn
clockwise. The Alarm will lock into
place.

17
Black
Line (Hot)
Neutral
Signal
White
Red
Black
Line (Hot)
Neutral
Signal
White
Red
How to Wire and Mount the AC Powered Alarm
When installing an AC powered alarm (Model RF-360TEB), the mounting location is
determined by the position of the electrical box that will power the alarm. Electrical
power to the box must be disconnected prior to alarm connection and
installation!
With the AC power turned off, connect
the wire harness provided with the alarm.
Connect the black wire of the harness to
the black wire(s) in the electrical box.
Typical
Circuit
End of
Line
Circuit
Align and attach the mounting bracket
with the two screws from the electrical
box. Pass the wire harness through the
center of the bracket.
Plug the wire harness into the back of the
alarm.
Press and twist the alarm clockwise into
place (see Step 4 of previous section).
Reconnect power to the AC lines of the
smoke alarm circuit. The POWER icon will
glow continuously.
Using the supplied orange wire nut, cap
the red wire (not used) and push it back
inside the electrical box.
Connect the white wire of the harness to
the white wire(s) in the electrical box.
18
Cleaning Your Alarm
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
Over time dust might collect inside your alarm, altering its performance. If this
occurs, the WARNING icon will flash and the horn will chirp once per minute. To
clean the alarm perform the following:
Remove the alarm from its bracket. With an
AC powered alarm the wire harness must be
disconnected.
Using a coin as a screwdriver, rotate the 4
corner slots on the back of the alarm counter-
clockwise and carefully separate the two
halves of the alarm.
Twist the round bug shield counter-clockwise
to remove.
Vacuum all the internal surfaces carefully.
Wipe with a clean cloth.
Reassemble the alarm. Rotate the 4 corner
slots clockwise to tighten.
Re-install the batteries. All four lighted icons
will strobe on and the WARNING icon should
no longer flash. Re-mount the alarm on the
wall or ceiling.
If the WARNING icon flashing persists,
return the alarm to the manufacturer.
The removed bug shield can be rinsed with
water when removed from the alarm. Allow
to air dry completely before reinstalling.
Do not submerge the complete smoke
alarm in water. The sensitive electronics
will be damaged!

19
Alarm Specifications
Operating Voltage
RF-360TB 3VDC
RF-360TEB 120VAC, 60 Hz
Standby Current
RF-360TB 114uA
RF-360TEB 2mA (AC)/560uA (backup battery)
Alarm Current
RF-360TB 60mA
RF-360TEB 17mA/75mA
Battery Type (4) 1.5v Energizer E91 Alkaline
Sensitivity 1.0% to 3.0%
Operating Ambient Temperature 40°F - 100°F
Operating Humidity 0 - 95% Non-condensing
Alarm Dimensions 5.1” x 5.1” x 2.7”
Mounting Base Dimensions 5.0” x 5.0”
Weight 1.2 lbs (with batteries)
Heat Sensing
Fixed Temperature 135ºF
Rate of Rise 15ºF / minute, > 100ºF
Listings UL; CSFM
FCC Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may
cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning this equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
(1) Reorient or relocate the units. (2) Increase the separation between the equipment
and receiver. (3) Connect the equipment into a different circuit from that to which the
receiver is connected. (4) Consult the dealer or an experienced technician for help.
FCC Caution: Changes or modifications not expressly approved by Applied Fire
Technology LLC could void the user’s authority to operate the equipment.
20
Important Fire Safety Information
Be prepared for fire emergencies:
Plan Your Escape
• Draw a floor plan of your home.
• Show two ways out of each room.
• Discuss escape routes with everyone in your home.
• Agree on an outside meeting place where you’ll gather after escaping.
Be Prepared
• Familiarize every member of the household with the sound of the Smoke
and Heat Alarms.
• Have everyone in the home memorize the fire department’s emergency
phone number.
• Instruct each person to call the emergency number from a neighbor’s
phone or a mobile phone used outside the home.
• Teach everyone to unlock and open all windows, and release security bars.
• Make sure security bars are equipped with quick-release devices.
• Keep exits clear and free from furniture and clutter.
Practice!
• Hold home fire drills at least twice a year.
Get Out and Stay Out
• Once you’ve escaped from a fire, do not go back inside for any reason.
• Make fire drills realistic by pretending some escape paths are blocked by
smoke or fire.
If you live in an apartment building
• Learn and practice your building’s evacuation plan.
• If you hear a fire alarm, react immediately.
• Know the location of all building exits and fire alarm boxes.
• Use the stairs ... never use an elevator during a fire.
• If exits are locked or blocked, report the problem to your building’s
management.
Escape Tips
• Close doors behind you as you escape to slow the spread of fire and smoke.
• If you have to escape through smoke, crawl on your hands and knees, keeping
your head one to two feet above the floor, where the air will be clearest.
• Test the doorknob and spaces around the door with the back of your hand. If
the door is warm, try another escape route. If the door is cool, open it slowly.
Close it quickly if smoke pours through.

21
Warning! Limitations of Smoke Alarms
Wireless smoke alarms have been proven to be both effective and reliable,
but they may not be effective under all conditions. No alarm design can offer
total protection of life and property. A smoke alarm is not a substitute for an
adequate homeowner’s fire insurance or life insurance policy.
Smoke alarms will not work without a source of power. The alarm will not
operate and the alarm will not sound if the batteries have died or been removed.
Or in the case of an AC powered alarm, the wiring has not been properly
connected.
Radio communication between alarm units may fail to take place if significant
changes to the home have occurred since installation and testing. Moving
large objects such as a refrigerator or metal cabinet could impede alarm radio
performance.
Alarm warning signal may not be heard. A deep sleeper, hearing-impaired
person, young child or someone impaired by drugs or alcohol may not awaken
in response to an alarm activation. This can occur even when an alarm is located
inside the individual’s bedroom. Be sure fire drills are practiced that take this
possibility into account.
Smoke alarms may not always activate and provide early enough warning. A
smoke alarm will only activate when it is maintained in working order and
sufficient smoke reaches the unit. Certain fires can originate inside of walls,
attics or on the other side of closed doors. This may prevent smoke from
reaching the alarm.
High heat and flame incendiary fires might block egress. Even with properly
placed alarms, certain flaming fires might occur and grow so quickly as to block
exit from the home.
SMOKE ALARMS CAN NOT GUARANTEE THAT YOU WILL NEVER SUFFER ANY
DAMAGE OR INJURY FROM A FIRE.
22
For a period of 24 months from the date of purchase, Applied Fire
Technologies LLC warrants to you, the original consumer purchaser, that your
Homefront Smoke Alarm will be free from defects in workmanship, materials,
and construction under normal use and service. If a defect in workmanship,
materials, or construction should cause your Homefront Smoke Alarm to become
inoperable within the warranty period, Applied Fire Technologies will repair
your Homefront Smoke Alarm or furnish you with a new or rebuilt replacement
Homefront Smoke Alarm without charge to you except for your costs of shipping
the Homefront Smoke Alarm to Applied Fire Technologies for warranty coverage.
Your repaired or replacement Homefront Smoke Alarm will be returned to you
without charge and will be covered under this warranty for the balance of the
warranty period.
This warranty will not apply if inspection of your Homefront Smoke Alarm
shows that the damage or failure was caused by abuse, misuse, abnormal usage,
faulty installation, improper maintenance, or work other than that performed by
authorized service personnel.
Any warranties implied under any State law, including implied warranties
of merchantability and fitness for a particular purpose, are limited in duration
to the period of this limited warranty. Some States do not allow limitations on
how long an implied warranty lasts, so the above limitation may not apply to
you. Neither the Homefront manufacturer nor Applied Fire Technologies will
be liable for any loss, damage, incidental or consequential damages of any kind
arising in connection with the sale, use, operation, inoperability, malfunction, or
repair of your Homefront Smoke Alarm. Some States do not allow the exclusion
or limitation of incidental or consequential damages, so the above limitation or
exclusion may not apply to you.
If a defect in workmanship, materials, or construction should cause your
Homefront Smoke Alarm to become inoperable within the warranty period,
to obtain warranty coverage you must ship the Homefront Smoke Alarm to
Applied Fire Technologies, with shipping costs prepaid by you. You must also
pack the Homefront Smoke Alarm to minimize the risk of it being damaged
in transit. You must also enclose a return address. Homefront Smoke Alarms
returned for warranty service should be sent to: Applied Fire Technologies LLC,
801 Hammond Street, Suite 200, Coppell TX 75019, accompanied by proof of
purchase.
If Applied Fire Technologies receives a Homefront Smoke Alarm in a damaged
condition as the result of shipping, you will be notified and you may need to file
a claim with the shipper.
This Limited Warranty gives you specific legal rights, and you may also have
other rights which vary from State to State. This is your copy of the Limited
Warranty on your Homefront Smoke Alarm. Please retain it, along with proof of
purchase showing the date of purchase and the identity of the purchaser, in a
safe place.
Limited Warranty

23
25 Year Product Replacement Guarantee
After the above Limited Warranty has expired, commencing on the first
day of the 25th month and extending through the last day of the 324th month
following the date of purchase, the manufacturer of the Homefront Smoke
Alarm guarantees to repair or replace the smoke alarm at a preferred owner
discounted price which includes shipping and handling and is adjusted annually.
This Product Replacement Guarantee does not create any obligations or liabilities
on the part of Applied Fire Technologies.
This guarantee is extended only to the original purchaser and is available
when the smoke alarm is sent to the manufacturer, with a description of any
problem and proof of purchase. This replacement guarantee will not apply if
the manufacturer’s inspection reveals that the damage or failure is a result of
abuse, misuse, improper maintenance, abnormal usage, or work performed by
unauthorized service personnel. At least an annual cleaning (according to the
directions supplied in this owner’s manual or set forth at www.homefrontalarms.
com) is recommended to prolong the useful life of your Homefront Smoke
Alarm.
To obtain a replacement under this guarantee, contact the manufacturer
at www.homefrontalarms.com or at (972) 304-3923, to receive information as
to then-applicable pricing and for the address to which you should send your
Homefront Smoke Alarm along with payment for your replacement alarm.
Be sure to enclose your return address and daytime telephone number. The
Homefront manufacturer will ship the new replacement unit to you upon its
receipt of all of the foregoing materials and information.
This Product Replacement Policy does not alter or affect your Limited
Warranty, set forth above.
The Homefront Smoke Alarm manufacturer guarantees to replace at no
cost to the original owner any Homefront Smoke Alarm that has been materially
damaged or destroyed by an accidental fire. To obtain a replacement alarm
under this Lifetime Fire Replacement Guarantee, you must return the damaged
or destroyed smoke alarm to the manufacturer within 90 days of the fire,
accompanied by a complete activation report and verification report from the
applicable fire department. To obtain a replacement under this guarantee,
contact the manufacturer at www.homefrontalarms.com or at (972) 304-3923,
to receive information as to the address to which you should send your damaged
or destroyed Homefront Smoke Alarm and accompanying information.
Lifetime Fire Replacement Guarantee
24
90-3021-10 A
801 Hammond Street, Suite 200
Coppell, TX 75019
APP LIE D FIRE
TECHNOLOGIES
Table of contents
Popular Smoke Alarm manuals by other brands

Kidde
Kidde TRUSENSE COMBO user guide