FUNCTION
STANDBY CONDITION: The red LED will flash every 40
seconds to indicate that the smoke alarm is operating properly.
ALARM CONDITION: When the alarm senses products of
combustion and goes into alarm the red LED will flash one
flash per second. The flashing LED and pulsating alarm will
continue until the air is cleared. When units are interconnected,
only the red LED of the alarm that senses the smoke or is
being tested (the originating unit) will flash. All other units in the
interconnected system will sound an alarm but their red LED’s
will NOT flash.
HUSH MODE: The red LED will illuminate for every 8 seconds,
indicating the smoke alarm is in the Hush Mode. Pressing and
releasing the Test button the smoke alarm will enter Hush mode.
INSTALLATION OF THE SMOKE ALARM
The HOMEGUARD smoke alarm is easy to install. The unit is
fitted on a base plate with multiple fixing holes. The smoke
alarm is connected to power on a 3 pin terminal block on the
base plate. The smoke alarm easily slides on the base plate for
positive power connection.
This alarm cannot be operated from power derived from a
square wave, modified square wave or modified sine wave
inverter. These type of inverters are sometimes used to supply
power to the structure in off grid installations, such as solar or
wind derived power sources. These power sources produce
high peak voltages that will damage the alarm.
Installing smoke alarm on its own subcircuit will avoid
false alarms and nuisance chirping that may be caused by
electromagnetic interferences from other electrical equipment.
The HOMEGUARD HG3000 is not designed to be
interconnected with other brands or products. Should other
products need to be interconnected for a complete system,
please contact PSA PRODUCTS for more information.
SPECIFICATIONS
Model HG3000
Detection Method Photoelectric /
Photo-optical sensing technology
Operation Stand-alone or interconnect up to 24 units
Power Requirement 240V AC 50Hz sine wave supply
Power Backup 9Vdc battery
Rating 80mA max per alarm
Alarm sound 85dB at 3m
Low battery indication Sounds a chirp at 40 second intervals,
in addition to red LED flashing
Hush Function 10-15 minutes.
Red LED flash every 8-10 seconds.
Alarm duration As long as smoke is present, unit
automatically resets when smoke clears
Alarm indication Flashing red LED indicator every second.
Temperature Range 4˚C to 45˚C
Humidity Range Up to 95% relative humidity (RH)
Size (W x H) 120 x 40mm
Wiring Hard wire
3 pin terminal block.
LED Green, power indicator.
Red, alarm indicator
Warranty 5 years – limited warranty excludes battery
Compliance
Activfire Approved and listed to AS3786:
Australian standards certified product.
Australian Electrical Authority Approval.
RCM.
Manufactured under ISO9001
Tested & complies to
Australian Standards
AS3786:2014