HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER
68-0244
5
PLUMB NG THE SADDLE VALVE
Hot or cold water, either hard or so tened, can be used in the
humidi ier.
1. Use the sel -piercing saddle valve (included) to tap into
the water supply line at an appropriate location.
IMPORTANT
• The saddle valve is not designed to regulate ater
flo . The valve is either open or closed.
• To prevent debris from clogging the solenoid inline
filter, be sure to install the saddle valve handle
pointing to ard the ceiling.
NOTE: Lightly clean the copper tubing ends with ine
sandpaper be ore making any connections.
2. Use 1/4 in. O.D. copper tubing and connect the saddle
valve to the inlet side o the solenoid valve.
CAUT ON
Hazardous Voltage.
Can cause personal injury or equipment damage.
Do not use any line connected to an air conditioner.
a. Place the brass compression nut over the copper
tubing.
NOTE: Do not over tighten the compression nut.
Moderate tightness prevents leaking.
b. Slide the brass errule over the tubing.
c. Insert the tubing into the solenoid valve itting and
support the valve while tightening the
compression nut.
3. Connect a 1/2 in. (13 mm) drain tube to the humidi ier
drain itting and run to a suitable drain.
NOTE: Slope the drain tube downward or correct
drainage.
CHECK NG THE NSTALLAT ON
Use the ollowing procedure to check out the humidi ier
installation:
1. Open the saddle valve.
2. Set the thermostat setpoint to 10°F (6°C) above the
room temperature.
NOTE: The urnace blower must be on or the
humidi ier to operate.
3. Set the Convertible Humidity Control to a high setting,
or place the H1008A Automatic Humidity Control in the
Test position.
4. Observe the water running out o the drain line to be
sure the humidi ier is working.
5. Check or leaks.
6. Reset the thermostat and Convertible Humidity Control
to a com ortable setting, or the Automatic Humidity
Control to the desired rost actor setting, or automatic
operation.
OPERAT NG THE HUM D F ER
The HE225A and HE265A
Humidi iers are controlled by
the Convertible Humidity
Control that is installed either
on an interior wall in the living
area or on the return air duct.
Choose the humidity control
setting using the combination
relative humidity/outdoor
temperature setting scale on the
humidity control dial. Match the
dial setting to the outdoor temperature or optimizing the
humidity level while reducing the moisture condensation on
inside windows. Table 5 can also be used to adjust the
humidity control to the recommended setting.
NOTE: As the outside temperature drops, the
recommended setting is lowered to accommodate
the e ects o dewpoint. These settings should
reduce the accumulation o moisture and ice on the
windows and in other areas o the house.
Some indoor activities such as cooking, showering and
clothes drying can cause excessive levels o humidity and
start the accumulation o moisture on the windows.
NOTE: I this condition persists or more than a ew hours,
set the humidity control to the lowest setting to turn
o the humidi ier. I the condition does not improve,
ventilate your home to remove the moisture.
The Enviracaire Elite HE225B
and HE265B Humidi iers are
controlled by the Honeywell
H1008A Automatic Humidity
Control with HumidiCalc+
So tware. The automatic
humidity control is mounted in
the return air duct where it can be
exposed to the air stream o the
return air. The HumidiCalc+ So tware
inside the automatic humidity control
is designed to automatically adjust the humidity level based
on indoor temperature and humidity, in erred or measured
outdoor temperature, and the setting o the rost actor dial.
The rost actor allows or variations in urnace size, window
insulation and average daily climate temperature.
The Automatic Humidity Control with HumidiCalc+ So tware
requires an initial adjustment period. Set the rost actor dial
on 5 and use Table 6 to adjust the rost actor—only one
setting at a time—increasing the dial setting or more
humidity, or reducing the setting i moisture develops on
inside windows. For more precise humidity adjustment, set
the rost actor between dial settings. Allow two days or the
humidity level to subside be ore making urther adjustments.
Once the proper setting has been ound, no urther
adjustment is needed. HumidiCalc+ So tware takes over
and makes any uture adjustments caused by varying outdoor
temperatures, thus reducing moisture build-up on windows
while maintaining the optimal humidity level.
M12817
H1008A
Humidity Control
Régulateur d'humidité
-20°F
-10°F
0°F
+10°F
+20°F
Over 20°F
15%
20%
25%
30%
35%
40%
HUMIDITY
SETTING
OUTDOOR
TEMPERATURE
-30°C
-25°C
-20°C
-10°C
-5°C
Over0 °C
M14694
H8908A