manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Honeywell
  6. •
  7. Monitor
  8. •
  9. Honeywell Fire-lite Alarms ANN-80-W Technical manual

Honeywell Fire-lite Alarms ANN-80-W Technical manual

This manual suits for next models

3

Other Honeywell Monitor manuals

Honeywell IAQPoint2 User manual

Honeywell

Honeywell IAQPoint2 User manual

Honeywell HMLCD17E2 User manual

Honeywell

Honeywell HMLCD17E2 User manual

Honeywell GCM-1014S User manual

Honeywell

Honeywell GCM-1014S User manual

Honeywell Multi-Mon User manual

Honeywell

Honeywell Multi-Mon User manual

Honeywell HMLCD19 User manual

Honeywell

Honeywell HMLCD19 User manual

Honeywell MeshGuard FTD-2000 User manual

Honeywell

Honeywell MeshGuard FTD-2000 User manual

Honeywell HMC14 User manual

Honeywell

Honeywell HMC14 User manual

Honeywell IAQPoint2 User manual

Honeywell

Honeywell IAQPoint2 User manual

Honeywell Bendix/King KMD850 Installation and operating instructions

Honeywell

Honeywell Bendix/King KMD850 Installation and operating instructions

Honeywell HHMC21 User manual

Honeywell

Honeywell HHMC21 User manual

Honeywell S7999D1048 User manual

Honeywell

Honeywell S7999D1048 User manual

Honeywell RDD100 User manual

Honeywell

Honeywell RDD100 User manual

Honeywell Notifier LCD2-80 User manual

Honeywell

Honeywell Notifier LCD2-80 User manual

Honeywell Bendix/King KMD 550 Installation and operating instructions

Honeywell

Honeywell Bendix/King KMD 550 Installation and operating instructions

Honeywell 7800 SERIES Operation manual

Honeywell

Honeywell 7800 SERIES Operation manual

Honeywell BW RigRat User manual

Honeywell

Honeywell BW RigRat User manual

Honeywell CM4 Release Note

Honeywell

Honeywell CM4 Release Note

Honeywell MT-SY-HWLM1916 - Arius 19" Widescreen LCD... User manual

Honeywell

Honeywell MT-SY-HWLM1916 - Arius 19" Widescreen LCD... User manual

Honeywell HMC21 User manual

Honeywell

Honeywell HMC21 User manual

Honeywell NOTIFIER LCD-160 User manual

Honeywell

Honeywell NOTIFIER LCD-160 User manual

Honeywell IAQPoint User manual

Honeywell

Honeywell IAQPoint User manual

Honeywell S7760A User manual

Honeywell

Honeywell S7760A User manual

Honeywell GENESIS DM User manual

Honeywell

Honeywell GENESIS DM User manual

Honeywell HMLCD15 User manual

Honeywell

Honeywell HMLCD15 User manual

Popular Monitor manuals by other brands

Samsung ME32C user manual

Samsung

Samsung ME32C user manual

ViewSonic VA926-LED user guide

ViewSonic

ViewSonic VA926-LED user guide

Furuno Mu 120c Operator's manual

Furuno

Furuno Mu 120c Operator's manual

Asus VB171D - 17" LCD Monitor Service manual

Asus

Asus VB171D - 17" LCD Monitor Service manual

AOC 9GLR Technical specifications

AOC

AOC 9GLR Technical specifications

DMG RAFFAELLO manual

DMG

DMG RAFFAELLO manual

AOC LM720 - 17" Technical specifications

AOC

AOC LM720 - 17" Technical specifications

Sony Trinitron GDM-F500 Service manual

Sony

Sony Trinitron GDM-F500 Service manual

Memorex MT1701 user guide

Memorex

Memorex MT1701 user guide

ViewSonic VE510s-4 Service manual

ViewSonic

ViewSonic VE510s-4 Service manual

Farenheit T-1503CM instruction manual

Farenheit

Farenheit T-1503CM instruction manual

Ditel DINOS DN129/AT Quick installation guide

Ditel

Ditel DINOS DN129/AT Quick installation guide

Sony SDM-S51 Specifications

Sony

Sony SDM-S51 Specifications

Kenwood DMX1025BT quick start guide

Kenwood

Kenwood DMX1025BT quick start guide

Dell S2409WFP user guide

Dell

Dell S2409WFP user guide

EverFocus EN-7517E instruction manual

EverFocus

EverFocus EN-7517E instruction manual

Dell P3222QE user guide

Dell

Dell P3222QE user guide

Panasonic TH152UX1 - 152" PLASMA TV Service manual

Panasonic

Panasonic TH152UX1 - 152" PLASMA TV Service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

One Fire-Lite Place
Northford, CT 06472-1653 USA
203-484-7161 • FAX 203-484-7118
www.firelite.com
ANN-80 Series Annunciators
Product Installation Document
PN 52749:D3 9/30/2021 ECN: 4925
General
The ANN-80 Series Remote Fire Annunciators and Indicators (ANN-80,
ANN-80-W, ANN-80C) are compact, backlit LCD displays designed for
use with compatible FACPs (Fire Alarm Control Panels). The displays
mimic the FACP display and are capable of displaying English-language
text of system point status including device type, independent point
alarm, trouble or supervisory zone and custom labels programmed into
the FACP. Refer to the FACP manual installation section for detailed
system information and wiring.
Specifications
TB1 Terminals 1 & 2
Operating Voltage Range: 18.8VDC to 38.2VDC
Maximum Current Consumption:
• Normal/Standby (no activity): 39mA
•Trouble Condition: 46 mA
•Alarm: 48mA
•AC Fail (not backlit): 15 mA
TB1 Terminals 3 & 4
ANN-BUS rated at 5.5 VDC and 60 mA max.
Dimensions
6-7/8”W x 5-3/8”H x 1-3/8”D
Mounting
The ANN-80 Series plastic enclosures can be surface or semi-flush
mounted in a single, double or 4” square electrical box.
To mount the ANN-80 Series enclosure:
1. Open the ANN-80 Series cover by turning the key switch
counterclockwise to the ON (Unlocked) position.
2. Push in the snap latch tab located on the right side while pulling the
cover open.
3. Pull wire through 7/8” hole in backplate and feed through wire
channel to lower left corner of backplate before routing to terminal
block (refer to appropriate FACP manual).
4. The cover must remain attached to the backplate while mounting
the annunciator to the electrical box/wall. The cover cannot be
reattached or removed after the annunciator has been mounted.
5. If the cover should become detached from the backplate, reattach as
shown below.
6. Surface or Semi-flush mount the ANN-80 to a single, double or 4”
square electrical box. The ANN-SB80KIT(-R/-B/-W) is an
available kit that contains two plastic backboxes that can be used to
surface mount the ANN-80 Series.
Wiring the ANN-80 Series to the FACP
Refer to Table 1 and Figure 3 for wiring connections.
NOTE: Installation and wiring must be done in accordance with
NFPA 72 and local wiring codes.
Backplate
Press in latch
and then
Pull open cover
Key switch shown
in OFF position
Cover with
LCD Display
Figure 1 Opening the ANN-80 Series
ANN-80 Series
Terminals (TB1)
FACP ANN-BUS
Terminals
Terminal 1 (-) (-)
Terminal 2 (+) (+)
Terminal 3 (A) A (ANN-BUS)
Terminal 4 (B) B (ANN-BUS)
ANN-80 Series
Terminals (TB2)
FACP ANN-BUS
Terminals
Terminal 1 Earth Ground
Table 1 ANN-80 Series to FACP Connections
ANN-80
Series
Cover
ANN-80
Series
Cover
ANN-80
Series
Backplate
ANN-80
Series
Backplate
• Position cover behind
backplate.
• Align hinge posts and
holes
• Slide holes down
onto posts.
• Close cover to lock
hinges into place.
Figure 2 Cover Reattachment
2ANN-80 Series Installation Document —P/N 52749:D3 9/30/2021
Notes:
1. All connections/sources must be power-limited and supervised.
2. 12 - 22 AWG (0.33- 3.31 mm2) wire for 24 VDC circuit is
acceptable.
3. Power wire distance limitation is set by 1.2 volt maximum line drop
from source to end of circuit.
4. Maximum distance from FACP to last ANN-BUS device must not
exceed 6,000 feet (1,800 m). Refer to the Wiring Distance Table in
the appropriate FACP manual for wire gauge and distance
limitations.
Setting the DIP Switches
Address Setting
Each ANN-BUS device requires a unique address. DIP switches 1-4 on
S1 are used to set the address. This address will be displayed on the
LCD display as the Station ID number.
Amaximum of 8 devices can be connected to the FACP ANN-BUS
communication circuit. ANN-BUS device addresses do not need to be
sequential and can be set to any number between 01 and 08. Note that 00
is not a valid address. The following illustrates the DIP switch settings
for each address (ID Number).
Communication Protocol
DIP switch 5 is used to determine the communication protocol of the
ANN-80 Series. Set DIP switch 5 to ON for ANN-BUS protocol. This
switch must stay in the ON position for proper functionality.
End-of-Line Resistor
The end-of-line termination resistor must be enabled at S1 on the last
device on the communication circuit. All other annunciators should have
these switches set to disable.
DIP switches 7 and 8 are unused.
2
B (ANN-BUS)
A (ANN-BUS)
+ (24 VDC)
- (GND)
Connect to FACP ANN-BUS
and/or next device
Connect to FACP or UL Listed
Power Supply for Protective
Signaling and/or next device
ANN-80 Series
Figure 3 Wiring the ANN-80 Series to an FACP
}
}
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
ID Number
(Address)
(not valid) 00
01
02
03
04
05
06
07
08
DIP Switch S1
1 2 3 4 5 6 7 81 2 3 4 5 6 7 8
Ensure switch 5 is ON
1 2 3 4 5 6 7 81 2 3 4 5 6 7 8
termination enabled termination disabled