Cleaning Prep:
Remove the Front Panel, move the control switch to OFF.
After 3 min., move the switch to ICE, then replace the panel
.
After 3 min., remove the Front Panel, move the switch to OFF.
Remove all ice from the ice storage bin and/or dispenser
.
WARNING!IF ON DISPENSER, turn off the dispenser power
supply after dispensing all the leftover ice.
Cleaning:
Remove the Front Insulation Panel.Remove the Drain
Plug.Once the water tank has drained, replace the
Drain Plug and Insulation Panel.
NOTICE! DO NOT cross thread the drain plug.
Refill water tank by moving the control switch to ICE,
replace the Front Panel.After 3 minutes, remove Front
Panel, move switch to the OFF position.
Remove the Front Insulation Panels. Pour 43 fl.oz
(1,272 ml) of Hoshizaki Scale Away into the water
tank. Replace the front insulation panel.Turn the
cleaning valve left until completely vertical (open).
NOTICE! AVOID EXCESSIVE FOAMING, wait
1minute before next step.
Move the control switch to WASH, replace Front
Panel.
NOTICE! DO NOT leave the control switch on WASH
for extended periods when water tank is empty. It will
damage water pump seals.
3
min.
30
min.
Sanitizing:
•Fill the water tank
•CLOSE the cleaning valve
•Move control switch to ICE,
replace the front panel
•After 3 minutes, remove the
front panel
•Move control switch to OFF
•Remove the front insulation
panel
•Pour 5fl. oz (148 ml) of
chlorine bleach*into the
water tank
•Replace the front insulation
panel
•OPEN the cleaning valve
*Use bleach without additives.
Additives cause excessive foaming, and
reduces effectiveness of the cleaning.
•Wait 1 minute to avoid
excessive foaming
•Move control switch to WASH,
replace the front panel
•After 45 minutes, remove
the front panel
•Move control switch to OFF
•Remove the front
insulation panel
•Remove drain plug
•After the water tank has
drained, replace drain plug and
insulation panel
The ice maker must be cleaned &sanitized at least once a year.
unattended when panels are off
Tech Support: 1.800.233.1940
Cleaning Prep:
Remove the Front Panel, move the control switch to
OFF. After 3 min., move the control switch to ICE, then
replace the Front Panel
.
After 3 min., remove the Front Panel, move the
control switch to OFF. This removes the cubes from
the evaporator.
Remove all ice from the dispenser unit/ice storage bin.
ATTENTION! IF ON DISPENSER, turn off the dispenser
power supply after dispensing all the ice.
Cleaning:
Remove the Front Panel, move the service switch to
DRAIN. Move control switch to SERVICE. Replace
the Front Panel.
After 2 minutes, remove the Front Panel,move the
control switch to OFF.
Dilute Hoshizaki Scale Away with warm water (see Table below).
Remove the Front, Apron, Top, Left, & Left Insulation Panels
and pour cleaning solution into the water tank.
Sanitizing:
Dilute 5.25% chlorine
bleach* with warm water
(see Table below)
* Use bleach without additives.
Remove the front, apron,
top, left, & left insulation
panels
Pour the sanitizing solution
into the water tank
Replace all the panels, except
the front panel
Move service switch to
WASH and control switch to
SERVICE, replace the front
panel
After 15 minutes, remove
front panel
Move service switch to DRAIN,
replace the front panel
After 2 minutes, remove
front panel
Move control switch to OFF
min.
min.
Cleaners
The icemaker must be cleaned & sanitized at least once a year.
ATTENTION!
Do not leave icemaker
unattended when panels are off
Tech Support: 1.800.233.1940
Page 20