•11131 —Managed snapshots of a SQL volume set may cause errors. Affects SQL Server® 2005
pre SP3. SP3 or Microsoft Hot Fix KB934396 fixes this issue.
•11361 —Fixed issue with the Cliq assignvolume command where lack of initiator name caused
an error even though it is an optional parameter.
•10391 —Fixed interaction between installed CLI and SAN/iQ software whereby repeated use
of a few specific commands could cause unexpected memory usage.
•10396 —Fix included to assure network card settings on the NSM 160 are consistently showing
that TCP Segmentation Offload is turned off to prevent network communication problems in some
environments.
•10398 —Fixed a rare problem in the storage server that caused it to spontaneously restart under
a combination of heavy IO load and snapshot deletes.
•10409 —Changed the display for the iSCSI gateway connection to Hostname(IP Address) instead
of just the IP address for ease of use.
•10410 —Fixed the incorrect reporting of CPU Utilization in alert notification and performance
dashboard.
•10415 —Added upgrade logic to attempt repair of OS array when possible during upgrade
rather than failing when encountering this rare condition.
•10417 —Added a check for verifying IP address format of the Virtual IP in the CLIQ command
modifyCluster.
•10418 —Added additional checking for a few specific CLI commands when executed from the
on-node CLI.
•10537 —Made the System Watch monitoring variable a permanent variable to assure it is not
accidentally deleted.
•10544 —Added RAID controller cache status to the CMC hardware report.
•10563 —Added a Node Summary report to the Centralized Management Console tasks menu
to provide an efficient way to gather basic storage node information from multiple nodes.
•10576 —Field imaging now can be performed with the SATA-DVD drive on the NSM 2060.
•10606 —Fixed issue that blocked upgrades and back-outs if the OS hardware RAID array is
degraded or rebuilding.
•Fixed issue where the Failover Manager and ESX Failover Manger were sharing install IDs which
could cause some confusion.
Fixes originally released as patches
•9928 —The background parity initialization status has been corrected for RAID 5 and RAID 6
Logical Drives.
•10354 —Insight Manager agents are now compatible with 5.2x firmware.
•10355 —Storage nodes upgraded to SAN/iQ 8.0 that use CHAP authentication, now have
sessions displayed in the SAN/iQ 8.0 Performance Monitor.
•10394 —Eliminated interruption of logging services and addressed a service connection issue
that can lead to a short term volume availability outage.
•10518 —For the NSM2060/NSM4150 storage nodes, compress the RAID controller log to reduce
space utilization issues of the log partition.
•10534 —Fixed issue where a disconnect from the CMC occurred when the Service Console is
trying to upload large log files.
•10553 —An upgrade process does not complete properly, which can result in SAN/iQ services
not restarting as expected.
•10633 —Prevent the SAN/iQ store service from consuming excess memory in certain situations
involving large volumes/snapshots.
SAN/iQ software release notes 7