3. Parameters table
Name Item Setting range
FL Lower Range -1999-19998
FH Upper Range -1998-19999
FLC Zero Correcting Valve -1999-1999
DP Decimal Point 0-3
FHC Full Scale Correcting Valve 0.500-1.500
FT Digital Filter Time Constant 1-250
UNIT Unit display optional 0-15
SPS Sampling speed 1-6
YPP Peak Holding 0-1
RUN Automatic Power-off Setting 0-1
TIMR Automatic delay power-off time setting 0-99.6H
4. Operations
Name Remarks
Display
Window
Display
Window of
measured
Value
Indication of Measured Values.
Indicating signs and values of Parameters in the Parameter Set Up Mode.
Decimal point of final digit is the recording designation.
The S Key
In Measuring Mode, hold down the key for more than 3 seconds to enter
the Set Up Mode.
In Set Up Mode, hold down the key for more than 3 seconds, when
displaying sign of parameters to enter the next group of parameters or
return to the Measuring Mode.
In Set Up Mode, press the key once, when displaying sign of parameters
to change the next parameter of the same group of parameters.
In Set Up Mode, press the key once, when displaying content of
parameters to save the modified parameter.
The on/off
Key
Switching on press the key more than 3 seconds, if off , repeat .
Decrease parameter values or change setting mode in Set Up Mode
Operational
Keys
The back/light
Key
Press the key more than 3 seconds to open back light .
Increase parameter values or change setting mode in Set Up Mode
5. Installation
PM-3000 can be directly mounted in the hydraulic pipe through the pressure pipe joints (M20*1.5) other
size fittings available when ordering .In critical applications , such as severe vibration or shock , pressure
hose pipe connection can be micro-mechanical decoupling.
Note: The range less than 100Kpa must be installed vertically.