Humandata LNX-204 User manual

HuMANDATA LTD.
LAN Multiplexer 4:1
LNX-204
User’s Manual
Ver. 1.1

1
LNX-204 (Ver.1.1)
Table of Contents
Precautions......................................................................................................... 2
Revision History ................................................................................................. 1
Introduction........................................................................................................ 1
1. Product Configuration............................................................................................... 1
2. Product Summary ..................................................................................................... 2
3. Overview................................................................................................................... 2
3.1. Block Diagram .........................................................................................................2
3.2. Front Side.................................................................................................................3
3.3. Rear Side ..................................................................................................................4
4. Specifications ............................................................................................................ 5
4.1. AC adapter (Japan's specifications) .......................................................................6
4.2. Optional Accessories................................................................................................6
4.3. Power Supply ...........................................................................................................7
4.4. FG Terminal .............................................................................................................7
4.5. Selecting Switch.......................................................................................................7
5. External Contact Connector...................................................................................... 8
6. Connection examples................................................................................................. 9
7. Setting Tool............................................................................................................. 10
7.1. Access Flow of microSD card ................................................................................11
7.2. Function ................................................................................................................ 12
7.3. Write Setting Data................................................................................................ 17
7.4. Read Setting Data ................................................................................................ 19
7.5. Write or Read setting data over the network ..................................................... 21
8. Controller Command............................................................................................... 22
9. Virtual COM Port.................................................................................................... 22
10. Additional Documentation and User Support........................................................ 23
11. Warranty and Compensation................................................................................. 23

2
LNX-204 (Ver.1.1)
Precautions
1
This product uses ordinary off-the-shelf electronic components, and
is therefore inappropriate for use in applications that require special
quality or reliability and are expected to protect human lives or
prevent accidents, such as safety mechanisms in fields including
space, aeronautics, medicine, and nuclear power.
2
Do not be used underwater or in high-humidity environments.
3
Do not be used in the presence of corrosive gases, combustible gases,
or other flammable gases.
4
Do not turn on power when circuit board surface is in contact with
other metal.
5
Do not apply voltage higher than rated voltage.
6
This manual may be revised in the future without notice owing to
improvements.
7
All efforts have been made to produce the best manual possible, but
if users notice an error or other problem, we ask that they notify us.
8
Item 7 notwithstanding, HuMANDATA cannot be held liable for the
consequences arising from use of this product.
9
HuMANDATA cannot be held liable for consequences arising from
using this product in a way different from the uses described herein,
or from uses not shown herein.
10
This manual, circuit diagrams, sample circuits, and other content
may not be copied, reproduced, or distributed without permission.
11
If the product emits smoke, catches fire, or becomes unusually hot,
cut the power immediately.
12
Do not install the control cables or communication cables together
with the main circuit lines or power cables. In such an environment,
it may result in malfunction due to noise.
13
Be careful of static electricity.
Do Not
Attention

1
LNX-204 (Ver.1.1)
Revision History
Date
Revision
Description
December 26, 2018 v1.0 Initial release
July 9, 2019 v1.1 Replaced the order of section 7 and 8.
Introduction
Thank you very much for purchasing our product LNX-204.
LNX-204 is a LAN multiplexer to switch 4 channel LAN port. LNX-204 can change
the port physically by three ways: send simple command from PC via LAN, input
control signal from an external contact point or change switches of the product
body.
1. Product Configuration
The following lists the product configuration of the LNX-204.
LAN multiplexer (LNX-204) 1
microSD card with USB adapter 1
D-Sub 9pin M2.6 screw (#4-40 UNC is mounted) 2
AC adapter (DC5V) 1
Driver & Application CD 1

2
LNX-204 (Ver.1.1)
2. Product Summary
LNX-204 is a LAN multiplexer to switch 4 channel LAN port. LNX-204 can change
the port physically by three ways: send simple command from PC via LAN, input
control signal from an external contact point or change switches of the product
body.
This is very useful to switch external network to internal network, and to connect
with the network only when required. It can promote labor-saving for inspection
process and auto-inspection system of LAN devices.
LNX-204 supports PoE. That makes it possible to be powered via a LAN cable (PoE
compatible HUB or other is required). It can also be powered by the AC adapter.
Network setting can be saved to and restored from a microSD card. Restoring the
setting information from a microSD card is very convenient when replacing
LNX-204.
3. Overview
3.1. Block Diagram

3
LNX-204 (Ver.1.1)
3.2. Front Side
LEDs
Name (color)
Function
PWR Power LED (red) Turn on during the power is supplied.
LAN1-4 Connection LED (red) Turn on during connecting with common LAN Port.
Power LED
Connection LED x 4
Common LAN Port
LAN Port x 4

4
LNX-204 (Ver.1.1)
3.3. Rear Side
LEDs
Name (color)
Function
ACT Active LED (green) Turn on during network port communication.
LINK Link LED (yellow) Turn on when the power is supplied and LAN cable is
connected normally.
SYS System LED (red) Blink few seconds during reading process.
Turn on when system is ready.
BUSY micro SD card access
LED (red)
Turn on during accessing micro SD card.
When it turned off, you can extract the card.
Power Input
Selecting Switch
D-sub 9pin
male Connector
Link LED
Active LED
LAN Controller Port
System LED
FG Terminal
micro SD card Slot
micro SD card
Access LED

5
LNX-204 (Ver.1.1)
4. Specifications
Item
Description
Remarks
Model
LNX-204
Power
5VDC, Supplied by AC adapter or LAN
connector (PoE function)
PoE function supports
both mode A and B
Current Consumption
Less than 300mA
Network Interface
IEEE802.3 (10Base-T)
IEEE802.3u (100Base-TX)
half-duplex / full-duplex (auto detected)
Common/Selecting Port
10/100/1000 Base-T
LAN Connector
RJ45 x 6 ESD protection ±11KV
Protocol
TCP / UDP / Telnet
RS-232C Connector
D-Sub 9pin Male
(#4-40 UNC screws are mounted)
M2.6 screws are also
attached for accessary
Setting Memory Card
microSD card
For save and restore
the product setting
SPI mode
LED
Power LED
Connection LED x 4
System LED
micro SD card access LED
LINK Status LED (RJ45 Connector)
ACT Status LED (RJ45 Connector)
Operating Ambient Temp.
-20 to 60 [°C] (-4 to 140 [°F])
No condensation
permitted
Operating Ambient Humi.
10 to 85 %RH
Storage Ambient Tem.
-20 to 60 [°C] (-4 to 140 [°F])
Storage Ambient Humi.
10 to 85 % RH
Weight
Approx. 250 [g]
Only main body
Dimensions
165 x 80.5 x 39 [mm]
(6.496" x 3.169" x 1.535") Without projections
* There may be cases that these parts and specifications are changed.
* Power saving function (suspend, standby, sleep and others) is not supported
* Please use the microSD card that is included in the package.

6
LNX-204 (Ver.1.1)
4.1. AC adapter (Japan's specifications)
Item
Description
Remarks
Output
5VDC 2.0A
Plug
2.1mm inner diameter Positive Tip
Compatible DC Jack
2.1mm inner diameter
Operating Ambient Temp.
0 to 40 [°C] (32 to 104 [°F])
No condensation
permitted
Operating Ambient Humi.
30 to 85 % RH
Storage Ambient Temp.
-20 to 80 [°C] (-4 to 176 [°F])
Storage Ambient Humi.
10 to 95 % RH
Wire Length
1.6m
Weight
approx. 70 [g]
Dimensions
46 x 34 x 25 [mm]
1.811" x 1.339" x 0.984" Without projections
* This AC adapter is attached for use mainly in Japan. If you use in the other countries,
please check the specifications above and plug shape.
* There may be cases that this part and specifications are changed.
4.2. Optional Accessories
Model Name
Image
Description
ACC-027
Metal bracket type A
for vertical mounting USB/LNX series
JAN : 4937920801096
ACC-028
Metal bracket type A
for horizontal mounting USB/LNX series
JAN : 4937920801102
ACC-031
Din rail attachment type B for USB/LNX series
JAN : 4937920801256
ACC-036
Neodymium magnet set for USB/LNX series
JAN : 4937920801539

7
LNX-204 (Ver.1.1)
4.3. Power Supply
LNX-204 supports PoE function both A and B type as standard which make it
possible to be powered via a LAN cable (PoE compatible HUB is required). It also
can be powered by the AC adapter.
4.4. FG Terminal
Please connect FG terminal with earth ground as necessary.
4.5. Selecting Switch
You can change 4 LAN ports manually by setting selecting switch. When power on,
the setting is recognized as the default port setting.
If sending changing port command after setting this switch, the command is prior.
External contact point is also prior to this switch.
When you need to disable the selecting switch, set all the switches to ON.
Select No Port
Select LAN1 Port
Select LAN2 Port
Select LAN3 Port
Select LAN4 Port
Factory Setting

8
LNX-204 (Ver.1.1)
5. External Contact Connector
D-sub 9 pin connector is mounted as external contact. When SEL1-4 is shorted with
GND, the LAN port is switched.
e.g. Short SEL3 (pin no. 3) with GND (pin no.5): Common LAN port and LAN3 port
is connected.
* #4-40 UNC screws are mounted by factory setting. You can change them to attached
M2.6 screws.
* COM (pin No.9) is an option for DC 5V to 24V power input.
If you need to change LAN port directly from open collector or transistor, please
contact us.
Pin No
Name
Direction
Remarks
1
SEL 1 IN Select LAN1
2
SEL 2
IN
Select LAN2
3
SEL 3
IN Select LAN3
4
SEL 4
IN Select LAN4
5
GND - GND
6
NC - -
7
NC - -
8
NC
-
-
9
(COM) - Power Input
(option)
CASE
FG - Connect with
FG Terminal
D-Sub 9pin Male
To prevent the damage, for SEL 1 to 4 please use no-voltage contact (dry
contact) like relay contact or switches.
Notice

9
LNX-204 (Ver.1.1)
6. Connection examples
Change common port LAN or external network to LAN1-4.

10
LNX-204 (Ver.1.1)
7. Setting Tool
Setting tool supports to save and read network setting by a microSD card. This tool
does not require installation.
This is a screenshot from version 2.0

11
LNX-204 (Ver.1.1)
7.1. Access Flow of microSD card
Power ON
Detect
Ready
microSD
card
None
Setting data
WR_DATA.TXT
Find
None
Product type
Verify
OK
NG
BUSY LED flicker
Different product types in the setting
data and actual product.
It is necessary to correct the product
type by LNX setting tool.
Possible to remove of the
microSD card
PWR LED turn on
Write setting data
BUSY LED turn off
SYS LED turn on
Saving backup data of
RD_DATA.TXT in the micro SD card.
SYS LED flicker
(System start up)
BUSY LED turn on
Access to the microSD card is done
immediately after power input. When
BUSY LED is lighting, do not detach the
microSD card. You can detach it after
confirming BUSY LED is turned off.

12
LNX-204 (Ver.1.1)
7.2. Function
Item
Contents
Reading data
Read setting data (RD_DATA.txt) from microSD card.
Saving data
Save setting data (WR_DATA.txt) to microSD card.
Network
Read or write setting data over the network. LNX product and PC
must be connected to the same network segment.
Product select
Display product select window.
Copy to clipboard
Copy a display image to clipboard.
Exit
Terminate the application.

13
LNX-204 (Ver.1.1)
[Basic Setting]
Item
Contents
IP address
If DHCP is not used to assign an IP address, enter it manually.
Unique IP address must be used in the network. The default
setting is 0.0.0.0 (DHCP is enabled)
Subnet mask
A subnet mask defines the number of bits taken from the IP
address that are assigned for the host part.
Default gateway
A gateway address of a router which is allowed to communicate to
other LAN segments. This address should be an IP address of the
router which is in the same LAN segment.
Port number
Enter the local port number. The default setting is 10001.
If you change the value, please avoid the following numbers. They
are allocated to other function.
1-1024
Reserved for well-known ports
9999 Reserved for telnet setup
14000-14009
Reserved for old redirector
30704 Reserved for remote control of user I/Os
30718
Reserved for configuration

14
LNX-204 (Ver.1.1)
Protocol
From the drop-down menu, select TCP or UDP.
Normally TCP is used, but when one-to-multiple communication
like broadcast or sensitive-responsiveness is needed, please select
UDP. The default setting is TCP.
Remote Setting
(Tunneling mode)
Enable/Disable
Select to enable remote connection (tunneling).
The default setting is disable.
Remote IP address
Enter the remote IP address of tunneling target.
Remote Port number
Enter the remote port number of tunneling target.
Connection method
Select connection method to the target.
* Serial setting of LNX-204 is fixed.

15
LNX-204 (Ver.1.1)
[Extension]
Item
Contents
Pack control
Enable/Disable
Select to enable pack control.
Two packing algorithms define how and when packets are sent to the
network. The standard algorithm is optimized for applications in
which the unit is used in a local environment, allowing for very small
delays for single characters, while keeping the packet count low. The
alternate packing algorithm minimizes the packet count on the
network and is especially useful in applications in a routed Wide
Area Network (WAN). Adjusting parameters in this mode can
economize the network data stream.
The default setting is disable.
Idle gap time
Select idle gap time from 12, 52, 250 or 5000 msec.
After this idle gap time with no response from a serial device, data is
packetized and transmitted to the target. The default setting is 12.
Trigger character
Select packet size and set trigger character (hexadecimal digits).
Check sum
Select check sum size.

16
LNX-204 (Ver.1.1)
TCP keepalive
TCP keepalive time defines how many seconds LNX-204 waits
during an inactive connection before checking its status. If the unit
does not receive a response 7 consecutive times, it drops that
connection. Enter a value between 0 and 65 seconds. 0 disables
keepalive.
The default setting is 5.
Telnet Com port
control (RFC2217)
Set to enable when control COM port using Telnet.
The product enables a RFC2217 function to use a control signal used
in a serial port on a network. When it is not used this function, set to
disable.
I/O buffer clear
setting
Set it whether input/output buffer clear at the time of network
connection or disconnection.

17
LNX-204 (Ver.1.1)
7.3. Write Setting Data
1. Open Setting Tool for LNX series (LNX SETTING TOOL Ver*.*).
2. Select “LNX-204 LAN Multiplexer 4:1”, and click “OK”.
3. Enter the setting such as network or serial.
4. Insert a microSD card to PC (A USB adapter is included with the product)
5. Click “Saving data”.
Table of contents
Other Humandata Multiplexer manuals