Humes Oasis Clearwater Z54 DELUXE Instructions for use

OWNER OPERATION
MANUAL
CLEARWATER Z54 DELUXE

OWNER’S MANUAL | OPERATION AND MAINTENANCE MANUAL | 1
We urge you to fully read this Manual. The contents are important to your safety and the
operation of the Clearwater Z54 Deluxe Treatment System.
Keep this Manual with other important household manuals for future reference.
If you have questions regarding the safety and operation of your Clearwater Z54 Deluxe
Treatment System, contact your Local Authorised Service Technician.
• Do not attempt to service components of the system yourself, call your Accredited
Service Technician.
• Only Authorised Service Personnel are to remove covers on the Treatment System.
PLEASE READ CONTENTS
CLEARWATER Z54 DELUXE SYSTEM OPERATION ................................................................... 2
INTRODUCING PRODUCTS INTO THE SYSTEM........................................................................ 3
SYSTEM MAINTENANCE, MONITORING AND SERVICING...................................................... 6
TROUBLE SHOOTING – PROCESS FAILURE.............................................................................. 7
LIMITED WARRANTY .................................................................................................................. 8
INSTALLATION AND EXCAVATION DETAILS............................................................................. 9
ELECTRICAL REQUIREMENTS ................................................................................................. 10
SYSTEM MAINTENANCE – CANTERBURY AREA .....................................................................13

OWNER’S MANUAL | OPERATION AND MAINTENANCE MANUAL | 3
2
The system normally comprises 2 or 3 separate chambers (gravity or pumped system).
The system comprises a pre-treatment chamber (of 3,560 litres) gravity feeding to a
secondary treatment chamber (1,280 litres) incorporating a Zabel A100/300 ilter.
If a pump is incorporated into the system, the pump well has a capacity of 700 litres. Various
pumps can be itted to the system depending on duty requirements.
The system may also be itted with an electrical isolator switch and high water level audible
alarm, mounted on a post on the system, in the event of system malfunction.
INTRODUCTION INTRODUCING
PRODUCTS INTO
THE SYSTEM
Introducing harmful products into the system may reduce the eiciency of the system
or stop the treatment process by destroying the bacteria. These products that reduce
the eiciency or stop the treatment process can be grouped into two groups, prohibited
substances and limited-use substances. While the wastewater treatment system will process
most waste produced by the average household, the following information will maximise the
system’s eiciency and reduce the time period between primary chamber pump-outs.
NOTICE: Introducing harmful or damaging chemicals into your Clearwater Z54 Deluxe System
may void the Warranty.
A. Prohibited Substances:
These substances are detrimental to the system’s ability to process wastewater, even when
present in small amounts. Prohibited substances include but are not limited to the following:
Do not introduce the following prohibited substances into your Clearwater Z54 System:
• Plastic or rubber products, petroleum products, such as motor oil, paint, paint thinner,
petrol and solvents
• Non-biodegradable products, such as sanitary napkins, condoms and disposable
napkins
• Toxic substances such as pesticides, strong disinfectants and strong caustic drain
cleaners
• Large amounts of paper products, such as paper towels and synthetic ibrereinforced
products advertised as having “wet strength”
• Animal fats, such as bacon grease or lard (normal cleaning of pots and pans is
acceptable).
L
i
m
i
t
e
d
-
u
s
e
A
c
c
e
p
t
a
b
l
e
P
r
o
h
i
b
i
t
e
d

OWNER’S MANUAL | OPERATION AND MAINTENANCE MANUAL | 5
4
Chemicals
The following chemicals are prohibited substances and should not be poured into the
Treatment System:
• Herbicides
• Pesticides
• Paint
• Thinner
• Motor Oil
Have you read the “Essential Guidelines”?
(enclosed with your system information)
B. Limited-Use Substances:
Limited-Use substances in large concentrations will reduce or stop the treatment process.
The same substances in smaller concentrations will have no harmful eect on the treatment
process. You may use the following substances without harming your Clearwater Z54 Deluxe
Treatment System if you use the substance according to the manufacturer’s directions, use
the substances SPARINGLY, and do not introduce concentrated doses into the system:
• Bio-degradable laundry powders
• Laundry Bleach
• Detergents with Bleach
Household cleaners containing sodium bactericides such as:
• Pine oil (disinfectant used in general purpose liquid cleaners)
• N-alkyl dichlorobenzyl ammonium chloride (disinfectant used in detergents and spray
cleaners)
• Sodium hydroxide (LYE chemical used in drain openers and cleaners)
• Sodium dichlor-s-triazinetrione (powdered bleach used in scouring powders and
automatic dishwasher detergents)
• Ortho-phenylphenol (bactericide used in tub and toilet bowl cleaners)
Waste Food
Some food waste, whether or not it is run through a waste grinder will not be treated by the
system, but will remain in solid form and fall to the bottom of the septic tank. Therefore, you
should consider not using a waste grinder system, or disposing of these food items through
the Clearwater Z54 Deluxe Treatment System:
• Animal Bones
• Melon Rinds
• Corn Cobs
• Pips and Seeds
• Eggshells
• Any other non-edible food waste
C. Acceptable Substances:
Substances that are considered to be typical domestic wastewater are human waste, bath
and dish water and edible food waste.
The following substances may be used regularly without harming your Clearwater Z54
Deluxe Wastewater Treatment System:
• Laundry detergents without bleach
• Dishwashing detergents without bleach
• Toilet Paper
• Household cleaners containing sodium bicarbonate, sodium carbonate and sodium
borate.

OWNER’S MANUAL | OPERATION AND MAINTENANCE MANUAL | 7
6
SYSTEM
MAINTENANCE,
MONITORING AND
SERVICING
The Clearwater Z54 Deluxe is available as either a gravity fed or dosed pump system. The
owner should determine the status of the system, substances introduced into the system,
and the frequency of required pump-out as determined by the service provider.
Your Clearwater Z54 Deluxe System can be furnished with an annual service policy to ensure
proper operation of the system.
Primary and Secondary Chamber:
Periodically, waste will need to be removed from both chambers using normal pump-out
procedures.
Zabel A100/300 Filter:
The system is compelte with a Zabel bacteriological ilter which performs two primary
functions in a septic tank installation. It retains and ilters 75% of all suspended solids in the
tank and treats the wastewater by lowering the BOD5 more than 50%.
Dosed Pumping System:
A dosed pumping system is used to give a proportioned controlled low to the engineered
designed disposal ield, to allow for even distribution over the entire ield. Submersible
eluent pumps operate in harsh acidic conditions and should be checked on a regular basis
for satisfactory operation.
System Capacity:
The system is rated for a maximum of 810 persons or 1,800 litres per day. As with any system
it is important the system is not hydraulically overloaded as this will interfere with the organic
breakdown of the treatment process.
Visual:
Wastewater backup is characterised by wastewater lowing back into the house or slow
movement of wastewater in the drains. This may indicate a problem with your wastewater
treatment system. Identify where the backup is occurring within your home’s plumbing
system. If no material is blocking the drain, contact you Service Technician or local supplier.
TROUBLE
SHOOTING
PROCESS FAILURE
Problem Possible Causes Solutions
Audible alarm on control
panel is ringing
The pump has failed, or is
blocked
Remove pump from system
and determine if inlet is
blocked or complete pump
failure has occurred.
Wastewater is backing up
into the home sewer piping.
There is an obstruction in
the home sewer piping.
Check the piping lead to the
system visually or with drain
cleaning equipment for an
obstruction and correct.
There is an obstruction in
the discharge line from the
system.
Check the eluent piping
and lateral ield piping
visually or with drain
cleaning equipment for an
obstruction, and correct.
The lateral ield pump
has failed.
Check the operation of
the lateral ield pump
per the manufacturer’s
speciications.
The low rate to the system
is too high.
Check the maximum low
rate to the system to see
that it is within normal limits.
The tank requires cleaning
and/or a pumpout is
required.
Check the sludge depth in
both chambers of the tank
to see if it is below required
levels.
Zabel ilter has blocked.
Remove Zabel ilter from
system and clean as
necessary.

OWNER’S MANUAL | OPERATION AND MAINTENANCE MANUAL | 9
8
Oasis Clearwater Systems warrants each Clearwater Z54 Deluxe Treatment System to be free
from defects in material and workmanship for a period as follows:
(a) Concrete structure = 10 years
(b) Electrical and mechanical componentry = 12 months
(c) Zabel ilter = Lifetime Warranty
From the date of the sale to the ultimate consumer when properly registered with Oasis
Clearwater Systems. Oasis Clearwater System’s sole obligation under this warranty is as
follows:-
Oasis Clearwater Systems shall fulill this warranty by repairing or exchanging any
component part, F.O.B. factory, that shows evidence of defects, provided said component
part has been paid for, warrantee has notiied Oasis Clearwater Systems of the defect
complained of and the component is returned through an authorised Distributor,
transportation paid. There is no informal dispute settlement available under this LIMITED
WARRANTY.
The warranty does not allow for labour or travel.
The warranty does not cover Oasis Clearwater Treatment plants and related components that
have looded, by external means, or that have been disassembled by unauthorised persons,
improperly installed, subject to external damage or damage due to altered or improper
wiring or overload protection.
Other than the mechanical and structural working of the plant itself, Oasis Clearwater
Systems is not responsible for the in-ield operation of a plant. The proper operation of this or
any other individual wastewater plant depends upon proper organic and hydraulic laoding of
the plant. We cannot control the loading and thereby cannot control the amount of harmful
substances that may be discharged into the plant. Only the users of a plant can control
what enters the unit. Therefore, we provide a comprehensive user’s manual that outlines
substances that should be kept out of the plant.
This LIMITED WARRANTY extends to the ultimate consumer of the product. As herein
“ultimate consumer” is deined as the purchaser who irst had the plant installed, or in the
case of a system designed for non-permanent installation, the purchaser who irst uses the
system. It is the purchaser’s or any sub-vendee’s obligation to make known to any other
consumer, the terms and conditions of this warranty.
This warranty is a LIMITED WARRANTY and no claim of any nature shall be made against
Oasis Clearwater Systems unless and until the ultimate consumer, or his legal representative,
notiies Oasis Clearwater Systems in writing of the defect complained of and delivers
the product and/or defective part(s) freight prepaid, to Oasis Clearwater Systems or an
authorised agent.
Oasis Clearwater Systems reserves the right to revise, change or modify the construction
and design of the Clearwater Z54 Deluxe Treatment System, or any component part or
parts thereof, without incurring any obligation to make such changes or modiications in
equipment previously sold. Oasis Clearwater Systems also reserves the right, in making
replacements of component parts under this warranty to furnish a component part which, in
it’s judgement is equivalent to the part replaced.
LIMITED WARRANTY
Excavation Dimensions Clearwater Z54 Deluxe Unit 4 metres x 2.5 metres x 1.5 meters
(Less optional extension turrets)
The tank access lids should be 100mm above ground level (itted with risers if necessary), to
prevent stormwater and rainfall getting in, and be able to be easily accessed by servicemen.
Tank Dimensions
3.000m Long
2.000m Wide at Anti loatation feet
1.550m High
1.320m To Invert from base of tank
0.230m To Invert from top of Lid
INSTALLATION
AND EXCAVATION
DETAILS
INVERTED AT 300mm
MINIMUM 100MM LEVEL PACKING
1.55m
3.0m
2.0m
230
1320

OWNER’S MANUAL | OPERATION AND MAINTENANCE MANUAL | 11
10
Oasis Z54 tank controller installation guide
Refer to attached wiring and circuit diagram when installing the controller. All electrical work
must be carried out as per NZS 3000:2007 and NZECP2:1993. The controller is to be earthed
at the distribution board and the supply to the controller should be protected by its own
dedicated 16Amp 30mA RCD or as required. Any questions during installation please contact
N2P Controls on 09 570 1919.
This controller is rated to 4A at 230V and has been
designed for the Z54 pumps only.
1. Remove the cover from the controller.
2. Refer to wiring diagram to side. Wire the supply
Earth, Neutral and Phase to the bottom 3 terminals.
3. Wire the pump’s phase, neutral and earth terminals
to the next 3 terminals.
4. Wire the high level alarm loat to the terminals
labelled Alarm NO (Brown Wire) and Alarm NO
(Black Wire). The loat is to be wired Normally Open
(NO). The blue wire is not used and can be wired to
the Alarm Not Used (Blue Wire) terminal. The level
loat is low voltage.
5. NOTE: The ON/OFF switch is to turn power on and
o to the pump and printed circuit board only.
6. Once installed commission by:
• Power controller – Green Power LED light should
illuminate on front.
• Test pump by lifting the loat attached to the
pump.
• Test high level alarm by lifting high level alarm
loat. The red Fault LED should illuminate, buzzer
sound and alarm light lash.
• Press the mute button and the buzzer shall stop.
ELECTRICAL
REQUIREMENTS
Switch ON
Switch OFF
Alarm (Blue
wire not used)
Alarm NO
(Black Wire)
Alarm NO
(Brown Wire)
Pump Earth
Pump Neutral
Pump Phase
Supply Earth
Supply Neutral
Supply Phase
Refer to installation
information before wiring
Mute Options
There are three dierent mute options; Continuous, Chirp and Auto.
Continuous – The buzzer will sound continuously until the mute button is pushed. It will stay
muted until the next alarm state occurs
Chirp – The buzzer will sound continuously until the mute button is pushed. Once the mute
button is pushed, the buzzer will sound for one second every 10 minutes until the fault is
cleared.
Auto – The buzzer will sound continuously until 30 minutes have passed and then the buzzer
then will automatically mute.
The dierent mute options are changed by moving the link on the PCB highlighted below.
Z54 Tank
PCB
Auto
Chirp
Continuous
Move link to preferred
mute functionality.

OWNER’S MANUAL | OPERATION AND MAINTENANCE MANUAL | 13
12
SYSTEM
MAINTENANCE,
MONITORING AND
SERVICE
Within the greater Canterbury area, Oasis Clearwater Systems oer an annual service and
maintenance contract to ensure your system functions correctly.
Service procedure includes the following:
1. Visual inspection of system to ensure correct biological function of system.
2. Septic and secondary chamber checked and biological breakdown of sewage analysed
for correct operation of system. Client notiied of correct timing for septic pump-out.
3. Zabel bacteriological ilter cleaned and repositioned as necessary.
4. If pump itted, unit removed, screen removed, impeller checked and unit fully cleaned
of debris/build-up.
5. Field service report presented to owner and council where applicable verifying work
carried out.
Switch
(4A Inductive Load)
Phase supply
Neutral supply
Earth supply
Pump phase
Pump neutral
Pump earth
Level loat
Level loat
Z54 Tank
PCB
Alarm Light
Neutral
240VAC
Float
Input
Auto
Chirp
Continuous

Head Oice
APO Box 16276 Hornby, Christchurch 8441
P 0800 48 48 49
F03 344 0267
Eoice@oasisclearwater.co.nz
Woasisclearwater.co.nz
oasisclearwater.co.nz
Table of contents
Popular Household Appliance manuals by other brands

GIESSE
GIESSE PROVENCE Fitting instructions

Smeg
Smeg PIANO DESIGN P-SDP20 Pedestal Installation

Mr. Christmas
Mr. Christmas HOLIDAY HEIRLOOM MUSICAL ORNAMENT manual

MILLIKEN
MILLIKEN Walk off Processing and Handling Instructions

Oxyline
Oxyline OxyChem C 210 Instructions for use

Black & Decker
Black & Decker WW100 Original instructions