  9. Hycontrol Plumbob PB 3000 User manual

Hycontrol Plumbob PB 3000 User manual

Continuous level measuring sys
t
e
m
PB
3000
Technical information
/
Instruction
m
a
nu
a
l
Plum
bob
®
Table of
co
nt
e
nt
s
PB
3000
gi010412
page
G
1
P
age
Safety notes
/
Technical support
G2
------------------------------------------------------------------------------------------------------
Introduction
G3
------------------------------------------------------------------------------------------------------
Dimensions
G4
------------------------------------------------------------------------------------------------------
Technical data
Electrical Data
G8
Mechanical Data
G9
Operating conditions
G10
Approvals
G10
Sensor weight guide
G11
------------------------------------------------------------------------------------------------------
Options
/
Accessories
G12
------------------------------------------------------------------------------------------------------
Mounting
G14
------------------------------------------------------------------------------------------------------
Electrical
installation
PB 3000 Plumbob
G16
PB 9000 Remote Box
G20
------------------------------------------------------------------------------------------------------
Signal overview
G22
------------------------------------------------------------------------------------------------------
Programming PB 3000 Plumbob
Quickset menu
G24
Output adjustment menu
G26
Diagnostics menu
G29
Communication menu
G31
Modbus
register
G32
------------------------------------------------------------------------------------------------------
Programming PB 9000 Remote Box
G34
------------------------------------------------------------------------------------------------------
Commissioning
Interface measurement
G36
------------------------------------------------------------------------------------------------------
Diagnostics
Maintenance
G37
Failure
G39
------------------------------------------------------------------------------------------------------
Notes for use in Hazardous Locations
G40
Subject to technical change.
We assume no liability for typing e
rr
o
r
s
.
All dimensions in mm (inches).
Different variations to those specified are p
oss
i
ble
.
Please contact our technical
c
o
n
s
u
lt
a
n
t
s
.
All units in this information are
C
E
-
c
e
r
tifi
e
d
.
Continuous level measuring sys
t
e
m
PB
3000
Technical information
/
Instruction
m
a
nu
a
l
Plum
bob
®
Safety notes
/
Technical
s
upp
o
r
t
page
G
2
gi010412
PB
3000
N
o
te
s
•
Installation, maintenance
and
commissioning must
be
carried out only by qualified technical
personnel.
•
The product must
be used
only in
the
manner outlined in this instruction
manual.
Special attention must be paid to warnings and notes as
f
o
ll
o
w
s
:
W
ARNING
Relates
toa
caution symbol on
the
product
and
means,
thata
failure
to
observe
the
necessar
y
precautions
can
result in death, serious injury and/or considerable material
damage.
W
ARNING
Relates
toa
caution symbol on
the
product
and
means,
thata
failure
to
observe
the
necessar
y
precautions
can
result in death, serious injury and/or considerable material
damage.
This
s
y
mb
o
l
i
s
used,
when there
i
s
no
c
orr
e
s
p
o
nd
i
ng
c
a
ut
i
o
n
s
y
mb
o
l
on
theproduct.
C
A
U
T
ION
Safety sy
m
b
o
l
s
A failure to observe the necessary precautions can result in considerable material damage.
In manual and
o
n
product
Description
CAUTION:
refer to related documents (manual) for
details.
Earth (ground)
T
erminal
Protective Conductor
T
erminal
Technical s
upp
o
r
t
Please contact your local supplier (see www.hycontrol.com for address). Otherwise you can
contact:
Hycontrol Ltd
Tel. 0044 (0)1527 406800
Orchard Street
Redditch
Fax. 0044 (0)1527 406810
B98 7DP
[email protected]om
UK
www.hycontrol.com
PB
3000
gi010412
page
G
3
Continuous level measuring sys
t
e
m
PB
3000
Technical information
/
Instruction
m
a
nu
a
l
Plum
bob
®
I
n
t
r
o
du
c
t
io
n
The
Plum
b
o
b
®
PB 3000 is an electromechanic level
m
eas
u
r
in
g
instrument for continuous measuring of level or volumes in
s
il
os
,
hoppers or
t
a
n
k
s
.
A
pp
l
ic
a
t
i
o
n
s
•
Powder, granulate, small or coarse bulk g
oo
d
s
•
Interface measurement (solids in
w
a
t
e
r
)
Available for industries such
as
•
C
h
e
m
i
s
t
r
y
•
F
oo
d
•
C
e
m
e
nt
•
M
i
n
i
ng
•
P
l
a
s
t
i
c
s
•
others
F
e
atu
r
es
Pro
ce
ss
•
Suitable for most types of bulk g
oo
d
s
•
I
nd
e
p
e
nd
e
nt
of bulk
m
a
t
e
r
i
a
l
properties,
suchas:
Dielectricity and conductivity of the bulk g
oo
d
Dusty atmosphere in the
s
il
o
Changing humidity inside the p
r
o
du
c
t
Products that tend to
s
ti
c
k
•
No mechanical load on the silo roof, the sensor
w
e
i
gh
t
just touches the surface of the ma
t
e
r
i
a
l
•
Very
accurate measurement
S
e
r
v
ic
e
•
Simple installation and
c
o
mm
i
ss
i
o
n
in
g
•
Measurement principle easy to und
e
r
s
t
a
nd
•
Rope,
tape and
(optional) motor
w
i
th
i
n
c
r
ea
s
e
d
s
e
r
v
i
c
e
li
f
e
•
Low
m
a
i
nt
e
n
a
n
c
e
A
ppr
ov
a
ls
•
Approval for use in Hazardous Lo
c
a
ti
o
n
s
ATEX II
1/2 D (zone 20/21) and FM Class. II, III Div.1 Gr.
E
-
G
M
echanic
•
Measurement range
upto
40m
(
133
f
t
)
•
1 1/2"
process c
o
nn
e
c
t
i
o
n
p
o
ss
i
b
le
•
Different sensor weights, suitable for every
a
pp
li
c
a
ti
o
n
•
Internal tape cleaner for difficult ma
t
e
r
i
a
l
s
•
Window in lid
and e
x
t
e
r
n
a
l
start
button
(
o
pt
i
o
n
a
l)
•
Robust cast housing, ingress protection
I
P
66
E
l
ec
t
r
on
ic
•
Micro processor controlled measurement
•
Remote Box for e
x
t
e
r
n
a
l
p
ro
g
r
a
mm
i
ng
,
d
i
s
p
l
a
y
of level
and
d
i
a
gn
o
s
t
i
c
s
,
start
of measurement of
upto10
Nivobob
un
i
t
s
•
C
o
mp
r
e
h
e
n
s
i
v
e
d
i
a
gn
o
s
t
i
c
s
p
o
ss
i
b
ili
t
ie
s
•
Output
0
/
4
-
20m
A
/
Modbus
/
Profibus DP
/
counting p
ul
ses
•
Programmable
r
e
l
a
i
s
(
c
a
n
be used as
level limit
s
w
i
t
c
h
o
utput
s
)
•
Measurement
start
w
i
th
e
x
t
e
r
n
a
l
s
i
gn
a
l
or
i
nt
e
g
r
a
t
e
d
t
i
m
e
r
Fu
n
c
t
i
o
n
The
Plum
b
o
b
®
PB 3000 is mounted on the top of the silo. A se
n
so
r
weight is driven down into the silo. It is mounted at the end of a
r
o
p
e
or tape which is wound on a motor driven roller. Upon contact
w
it
h
bulk
m
a
t
e
r
i
a
l
,
the
motor changes
the
w
i
nd
i
ng
d
i
r
e
c
t
i
o
n
and the sensor
weight is driven back to the upper stop p
os
iti
o
n
.
During downwards movement of the sensor weight the distance
i
s
electronically measured by the rotations of the internal rope
/
t
a
p
e
roller. Themicrocontroller converts the measured distance into
a
n
output
s
i
gn
a
l
,
w
h
i
c
h
i
s
a
vo
l
um
e
t
r
i
c
s
i
gn
a
l
based
on
the
silo
g
e
o
m
e
t
r
y
.
The output
s
i
gn
a
l
i
s
updated, when
the
sensor weight touches
the
bu
l
k
m
a
t
eria
l
.
D
i
agn
o
s
t
i
c
s
Comprehensive diagnostics possibilities are p
r
ese
n
t
:
•
Measurement
c
o
nt
ro
l
i
s
done by
c
o
mp
a
r
i
ng
the
moved d
i
s
t
a
n
c
e
between up and downward movement and checking for d
i
s
c
r
e
p
a
n
c
y
.
I
n
case
of
d
i
s
c
r
e
p
a
n
c
y
,
the
sensor
w
e
i
ght
i
s
pu
l
le
d
tothe
upper
stop
p
o
s
i
t
i
o
n
to
ensure,
thatthe
sensor
w
e
i
ght
i
s
not
i
n
s
i
d
e the
s
il
o
.
•
S
e
r
v
i
c
e
i
nt
e
r
v
a
l
after
a
c
e
r
t
a
i
n
amount of measurements
and
r
unn
i
ng
ti
m
e
.
•
I
nt
e
r
n
a
l
c
o
nt
ro
l
of motor, motor
dr
i
v
e
r
e
le
c
t
ro
n
i
c
and smooth
movement of rope
/
tape
r
o
l
le
r
s
.
Diagnostics is in accordance with NAMUR
recommendation
N
E
107.
page
G
4
gi010412
PB
3000
Continuous level measuring sys
t
e
m
PB
3000
Technical information
/
Instruction
m
a
nu
a
l
Plum
bob
®
D
i
m
ens
i
o
ns
B
F
l
ange
s
fitting
t
o:
DN100 PN16
/ 4"
150
l
b
s
Lk
=
ø180-190.5mm
(
7.1
-
7.5
"
)
s
l
o
t
d2=
ø19mm
(
0.75
"
)
fitting
t
o:
2" / 3"
150
l
b
s
Lk
=
ø120.7-152.4mm
(
4.75
-
6.0
"
)
s
l
o
t
d2=
ø19mm
(
0.75
"
)
Housing
o
u
t
s
i
d
e
A
l
um
i
n
i
um
,
powder
coated
Housing
i
ns
i
d
e
A
luminium
Housing
ex
t
e
ns
i
o
n
A
l
um
i
n
i
um
,
powder
coated
or 1.4305
(
303
)
F
l
ange
80°C
/
150°C:
A
l
um
i
n
i
um
,
powder
coated
250°C: 1.4305
(
303
)
T
h
r
ead
1.4301
(
304
)
Socket
p
i
p
e
Flange version 80°C
/
150°C:
A
l
u
m
i
n
i
u
m
All other versions: 1.4301
(
304
)
Ro
p
e
1.4301
(
304
)
Ta
p
e
1.4310
(
301
)
Ro
p
e
ø1,25mm
(
0.49
"
)
Ta
p
e
12x0.2mm
(
0.4
7x
0.008
"
)
d2
X
C
A
X
A
C
Basic
t
y
pe
Flange v
e
r
s
i
o
n
H
o
us
in
g
Thread
v
e
r
s
i
o
n
H
o
us
in
g
H
o
us
i
ng
extension
H
o
us
i
ng
e
x
t
e
n
si
o
n
Flange
T
h
r
e
ad
S
o
cke
t
B
p
i
p
e
S
o
cke
t
p
i
p
e
Lk
F
l
a
ng
e
ve
r
s
i
o
n
,
bottom
v
i
e
w
Rope
/
t
a
p
e
Rope
/
t
a
p
e
D
im
ens
i
ons
X
=
Length to bottom of sensor
w
e
i
gh
t
(in upper stop position): see next p
a
g
e
A
=
Lenght of socket p
i
p
e
200mm
(
7.9
"
)
Optional 500mm
(
19.7
"
)
/
1000mm
(
39.4
"
)
Mat
e
rial
s
B
=
Diameter of socket p
i
p
e
Rope version
w
it
h
F
l
a
ng
e
DN100
/ 4"
ø60mm
(
2.36
"
)
All other ve
r
s
i
o
ns
ø40mm
(
1.57
"
)
C
=
Housing
e
x
t
e
ns
i
o
n
Flange ve
r
s
i
o
n
80°C
/
150
°
C
95mm
(
3.74
"
)
25
0°
C
340mm
(
13.4
"
)
Thread ve
r
s
i
o
n
80°C
/
150
°
C
160mm
(
6.3
"
)
25
0°
C
340mm
(
13.4
"
)
With option "Increased corrosion
r
e
s
i
s
t
a
n
ce
"
:
All metal parts in contact with the process are
c
oa
t
e
d
.
The rope is plastic coated with
P
A
.
The internal bearings are made of stainless s
t
ee
l
.
PB
3000
gi010412
page
G
5
Continuous level measuring sys
t
e
m
PB
3000
Technical information
/
Instruction
m
a
nu
a
l
Plum
bob
®
D
i
m
ens
i
o
ns
X
X
X
X
X
X
X
X
X
Options and
A
cce
sso
ri
e
s
Pos.
25
Window in lid
a
nd
outside start
bu
tt
o
n
Window in
li
d
Pos.
28
Compressed
air
c
onn
ec
t
or
Compressed
air c
o
nn
e
c
t
o
r
O
u
t
s
i
d
e
s
t
a
r
t
bu
tt
o
n
Sensor
w
e
i
gh
t
s
Solids measurement: Rope version
All
w
e
i
gh
t
s
ca.
1,0kg
(
2.2
l
b
s
)
PVC without p
i
n
PVC with pin
Stainless steel
C
l
aw
Ø81mm
(
3,2
"
)
X
=
137mm
(
5.4
"
)
Material:
P
V
C
Ø81mm
(
3,2
"
)
X
=
137mm
(
5.4
"
)
P
i
n
:
130mm
(
5.1
"
)
M
a
t
e
r
i
a
l
:
PVC (pin
PO
M
)
Version
w
it
h
F
l
a
ng
e
DN100
/ 4"
Ø75mm
(
3.0
"
)
X
=
25mm
(
1.0
"
)
Pin: 130mm
(
5.1
"
)
M
a
t
e
r
i
a
l
:
1.4305
(
304
)
All other ve
r
s
i
o
ns
Ø42mm (Ø
1.65
"
)
X
=
81mm
(
3.19
"
)
Pin: 130mm
(
5.1
"
)
Ø95
(
3.7
"
)
X
=
71mm
(
2.80
"
)
Material: 1.4305
(
304
)
Folding
c
o
v
e
r
F
loat
B
ag
Sp
i
de
r
380x380mm
(
15
x
15
"
)
X
=
150mm
(
5.9
"
)
Material: 1.4310
(
301
)
PA
c
a
nv
a
s
Ø190mm
(
7.5
"
)
X
=
175mm
(
6.9
"
)
M
a
t
e
r
i
a
l
:
Float
PP,
Cone: 1.4305
(
304
)
Ø600mm
(
23.6
"
)
X
=
160mm
(
6.3
"
)
Material: 1.4301 (304)
/
1.4310
(
301
)
Ø95mm
(
3.7
"
)
X
=
460mm
(
18.1
"
)
M
a
t
e
r
i
a
l
:
PA
canvas,
SS
c
h
a
i
n
,
a
l
u
cone
page
G
6
gi010412
PB
3000
Continuous level measuring sys
t
e
m
PB
3000
Technical information
/
Instruction
m
a
nu
a
l
Plum
bob
®
D
i
m
ens
i
o
ns
X
X
X
X
X
X
X
X
X
Solids measurement: Tape version
All weights ca. 2.1kg
(
4.6
l
bs
)
PVC with p
i
n
A
luminium
1.4305
(
304
)
Stainless
Claw
Fo
ldi
ng
steel
c
o
v
e
r
Ø95
(
3.7
"
)
X
=
236mm
(
9.3
"
)
Material: 1.4305
(
304
)
380x380mm
(
15
x
15
"
)
X
=
430mm
(
16.9
"
)
Material: 1.4310
(
301
)
PA
c
a
nv
a
s
Ø81mm
(
3,2
"
)
X
=
465mm
(
18.3
"
)
P
i
n
:
130mm
(
5.1
"
)
M
a
t
e
r
i
a
l
:
PVC (pin
PO
M
)
Ø42mm (Ø
1.65
"
)
X
=
320mm
(
12.6
"
)
Pin: 130mm
(
5.1
"
)
Material: 1.4305
(
304
)
B
ag
Sp
i
de
r
Ø600mm
(
23.6
"
)
X
=
345mm
(
13.6
"
)
Material: 1.4301 (304)
/
1.4310
(
301
)
F
loat
Ø190mm
(
7.5
"
)
X
=
285mm
(
11.2
"
)
Material: Float
PP
Ø95mm
(
3.7
"
)
X
=
575mm
(
22.6
"
)
M
a
t
e
r
i
a
l
:
PA
canvas,
SS
c
h
a
i
n
,
a
l
u
fi
x
i
ng
Interface measurement: Rope version
Weight
ca. 1,0kg
(
2.2
l
b
s
)
Interface measurement: Tape version
Weight ca. 2.1kg
(
4.6
l
bs
)
Ø81mm
(
3,2
"
)
X
=
82mm
(
3.2
"
)
including additional disks
t
o
adjust to the
a
pp
li
c
a
ti
o
n
Ø42mm (Ø
1.65
"
)
X
=
320mm
(
12.6
"
)
Pin: 130mm
(
5.1
"
)
Material: 1.4305
(
304
)
Material:
PVC
with plastic/metal
d
i
s
k
s
PB
3000
gi010412
page
G
7
Continuous level measuring sys
t
e
m
PB
3000
Technical information
/
Instruction
m
a
nu
a
l
Plum
bob
®
D
i
m
ens
i
o
ns
PB 9000 Remote
B
o
x
PB
9000
Panel
m
o
un
t
i
ng
Biasing network
Terminal p
l
ug
A
C
/
D
C
c
o
nve
r
t
e
r
Mounting: DINrail
35
Mounting: DINrail
35
PB
9000
Wall
m
o
un
t
i
ng
Mounting
h
o
l
e
s
Depth 90mm
(
35.4
"
)
page
G
8
gi010412
PB
3000
Continuous level measuring sys
t
e
m
PB
3000
Technical information
/
Instruction
m
a
nu
a
l
Plum
bob
®
Technical d
a
t
a
Electrical
d
a
t
a
Power supply
AC version 98 .. 253V
50
-
60
H
z
DC version 20 ..
28
V
(voltages incl. 10% of EN
61010
)
Installed load
AC version:
150 VA (including internal heater
(
80
W
))
DC
v
e
r
s
i
o
n
:
One unit:
150W (with or without internal heater)
*
Further units which are connected to the same power
s
upp
l
y
:
25W
per
un
i
t
(
w
i
th
o
ut
i
nt
e
r
n
a
l
heater, motor off)
**
50W
per
un
i
t
(
w
i
th
o
ut
i
nt
e
r
n
a
l
heater, motor
r
unn
i
ng
)
80W
per
un
i
t
(with
i
nt
e
r
n
a
l
heater,
s
upp
l
y
vo
l
t
a
g
e
20
V
DC
)
100W
per
un
i
t
(with
i
nt
e
r
n
a
l
heater,
s
upp
l
y
vo
l
t
a
g
e
24
V
DC
)
120W
per
un
i
t
(with
i
nt
e
r
n
a
l
heater,
s
upp
l
y
vo
l
t
a
g
e
28
V
DC
)
*Considers the max. motor traction which is needed in a failure condition. A failure condition is assumed
f
o
r
max. one unit at the same
ti
m
e
.
**
This
v
a
l
u
e can be
c
o
n
s
i
d
e
r
e
d
,
if
the
controlling PLC
starts the
measurement for max. one un
i
t
at thesame
t
im
e
.
Signal
o
u
t
pu
t
:
0
/
4
-
2
0mA
Max.
500
Ohms
(
a
c
t
i
v
e
,
i
s
o
l
a
t
e
d
)
Linearity
+/-
0,1
m
A
Signal
o
u
t
pu
t
:
R
e
l
ay
4x Relay
S
P
ST
:
max.
250
V
A
C
,
2
A
,
500
V
A
non
i
ndu
c
t
i
v
e
Signal
o
u
t
pu
t
:
Electronic counting pu
l
s
e
O
p
t
o
c
o
uple
r
max.
30
V
DC, max.
25
m
A
C
ommun
ica
t
i
on
:
Modbus
R
T
U
P
h
y
s
i
c
a
l
l
a
y
e
r
:
RS
485 and
Ground,
i
s
o
l
a
t
e
d
Mode: RTU, Type:
S
l
a
v
e
Device number range:
1 - 247
(
s
ele
c
t
a
b
le
in
m
e
nu
)
,
Baudrate:
1200to
57600 Baud, Data b
i
t
s
:
8,
Stop Bits:
1
Parity:
N
o
n
e
Multi-drop configuration
possible. Factory setting of adress is 31. Each unit which is connected to
t
h
e
network must be set to an individual
a
d
r
ess
.
Supported c
o
mma
nd
s
Reading: All diagnostics and parameters using command
03
HEX
:
Read Holding
R
e
g
i
s
t
e
r
Writing: All parameters using command
06
Multiple
R
e
g
i
s
t
e
r
)
.
HEX
:
Write Single Register (not supported is command
10
HEX
:
W
r
it
e
C
ommun
ica
t
i
on
:
Profibus
D
P
P
h
y
s
i
c
a
l
l
a
y
e
r
:
RS
485,
i
s
o
l
a
t
e
d
Type:
S
l
ave
Device number range:
0 - 126
(
s
ele
c
t
a
b
le
in
m
e
nu
e
)
,
Baudrate:
9.6
kbps
to12
M
bp
s
A
v
a
il
a
b
le
c
o
mmun
i
c
a
t
i
o
n
by GSDfile, Read only
(
S
e
n
s
or
weight bottom
to
m
a
t
e
r
i
a
l
(in
mm
))
Accuracy of
m
e
a
s
u
r
e
m
en
t
Out
p
ut
S
e
tt
ing
Ac
cu
ra
c
y
Counting
pu
l
se
10cm (1/3ft)
/
pu
l
se
5cm (1/6 ft)
/
pu
l
se
2,5cm
(
1
/
10
f
t
)
/
pu
l
s
e
1cm (1/20ft)
/
pu
l
se
1
pu
l
se
1
pu
l
se
2
pu
l
ses
4
pu
l
ses
0/
4
-
20m
A
1% of max.
r
a
ng
e
Modbus RTU
/
Profibus
0.5% of max.
r
a
ng
e
Display
LCD display: 2 line x 16
d
i
g
it
Indication light
Status by build in
LED: Power On,
R
e
l
a
i
s
,
M
a
i
nt
e
n
a
n
c
e and
F
a
il
u
r
e
PB
3000
gi010412
page
G
9
Continuous level measuring sys
t
e
m
PB
3000
Technical information
/
Instruction
m
a
nu
a
l
Plum
bob
®
Technical d
a
t
a
Memory
Non-volatile (no backup battery
r
e
qu
i
r
e
d
)
> 10
years
data
r
e
t
e
nt
i
o
n
Connection terminals
0.14 .. 2.5mm
2
(AWG 26 ..
14
)
Cable entry
According to
se
le
c
ti
o
n
:
Screwed cable gland: 2x M20x1.5 and 1x M25x1.5 Blindplug: 2x M20x1.5
o
r
Conduit
A
N
S
I
B1.20.1: 1x NPT
3/4"+
2x NPT
1/2"
Blindplug: 2x NPT
1/2"
Extension cables for
R
e
m
o
t
e
Box NB 9000 and
M
o
dbu
s
S
p
e
c
i
fi
c
a
t
i
o
n
s
see
in chapter
"
E
le
c
t
r
i
c
a
l
i
n
s
t
a
ll
a
t
i
o
n
"
Suggested cable types
see
in chapter
"
A
cc
e
ss
orie
s
"
Extension cables
f
o
r
Profibus
D
P
Use common recommended Profibus
c
a
ble
s
Isolation
Power supply to all other outputs
/
inputs: AC version 2210
V
r
m
s
DC version: 1000
V
D
C
Relay to relay: 2210
V
r
m
s
Protection class
I
Mechanical
d
a
t
a
Ingress p
r
o
t
ec
t
i
o
n
I
P
66,
Type
4
Process connection
T
h
r
ead
s:
F
l
a
ng
es
:
R
1 1/2"
D
I
N
2999tapered,
NPT
1 1/2"
or
3"
A
N
S
I
B1.20.1
tapered
DN100 PN16
E
N1
092
-
1
(unit fits to this
fl
a
ng
e
)
2"
or
3"
or
4"
150
l
b
s
A
N
S
I
B16.5 (unit fits
to
th
i
s
fl
a
ng
e
)
C
olo
u
r
H
o
u
s
i
ng
,
F
l
a
ng
e
L
id
RAL
5010 (gentian blue)
RAL 9006 (aluminium s
il
ve
r
)
Material
See detail specifications on page G4
-
G
6
Measuring range
Rope version max. 30m
(
100
ft
)
Tape version max. 40m
(
133
ft
)
Measuring speed
Sensor weight speed in
ave
r
a
g
e
:
Standard version: ca. 0.25m/s
(
0.8
ft
/
se
c
)
Version with brushless motor: ca. 0.33m/s
(
1.0
ft
/
se
c
)
Weight
Rope ve
r
s
i
o
n
with flange: ca. 11kg
(
24.2
l
b
s
)
with thread: ca. 12kg
(
26.4lb
s
)
Tape version
with flange: ca. 12kg
(
26.4
l
b
s
)
with thread: ca. 13kg
(
28.6lb
s
)
Deviation of vertical mounting
max.
2°
Compressed air c
o
nnec
t
o
r
(O
p
ti
on)
Quick
c
o
up
li
ng
incl. o
pp
o
s
i
t
e
part, for
hose
d
i
a
m
e
t
e
r
9mm
(
0.35
“
)
,
female
at
h
o
u
s
i
ng
Max. operating pressure 0.2bar
(
2.9
p
s
i
)
page
G
10
gi010412
PB
3000
Continuous level measuring sys
t
e
m
PB
3000
Technical information
/
Instruction
m
a
nu
a
l
Plum
bob
®
Technical d
a
t
a
Operating
c
o
nd
i
t
i
o
n
s
Process overpressure
-
0.3
..+0.3bar
(
-
4.4
..
+
4.4
p
s
i
)
-
0.5
..
+
1.7 bar
(
-
7.3
.. +25psi) optional for
CE
+
AT
E
X
-
0.5
..
+
1.1 bar
(
-
7.3
.. +16psi) optional for FM general pu
r
p
ose
Process temperature
-
40
°
C
..+80 /150
/
250°C
(
-
40
..+176
/
302
/
482
°
F)
Ambient
t
e
m
pe
ra
t
u
r
e
-
20
°
C
..
+
60
°
C
(
-
4
..
+
140
°
F)
-
40
°
C
..
+
60
°
C
(
-
40
..
+
140
°
F)
CE, FM General Purpose
with internal
h
ea
t
e
r
-
40
°
C
..
+
60
°
C
(
-
40
..
+
140
°
F)
ATEX, FM Class II on request
p
oss
ib
l
e
max.
+
40
°
C
(1
04
°
F)
Version with Process temp. 150°C
(
302
°
F)
Min. powder density
see
"Sensor
w
e
i
ght
gu
i
d
e
"
on next
page
Minimum time
be
t
w
een
measuring
s
t
ar
t
s
measuring height 5m (16ft
)
-
>3min
measuring height 10m (33ft)
-
>6min
measuring height 20m (66ft)
-
> 12min
measuring height 30m (98ft)
-
> 18min
measuring height 40m (131ft)
-
>
24min
R
o
pe
/
t
a
pe
operating
t
im
e
see page
G
38
Max. permitted tractive
f
o
r
ce
Tape
ve
r
s
i
o
n
:
with brushless
m
o
t
o
r
:
ca.
3000
N
standard
m
o
t
o
r
:
ca.
800
N
Rope
ve
r
s
i
o
n
:
with brushless
m
o
t
o
r
:
ca.
1000
N
standard
m
o
t
o
r
:
ca.
800
N
with increased corrosion
r
es
i
s
t
a
n
c
e
:
ca.
700
N
Relative humidity
0-100%,
s
u
i
t
a
b
le
for
outdoor
Altitude
max. 2000m
(
6.562
ft
)
A
pp
r
ova
ls
Hazardous Locations*
ATEX II
1/2 D (zone
20
/
21
)
FM Class. II, III Div.1 Gr.
E
-
G
G
O
ST
-
R
Ex
/
RTN
E
x
General purpose
*
CE
EN
61010-1
FM
General
pu
r
p
ose
EMC
EN
61326 -A1 (industrial
s
t
a
nd
a
r
d
)
*
Depending on selected version in price
li
s
t
PB
3000
gi010412
page
G
11
Continuous level measuring sys
t
e
m
PB
3000
Technical information
/
Instruction
m
a
nu
a
l
Plum
bob
®
Technical d
a
t
a
Sensor weight guide (solids
m
ea
s
u
r
e
m
e
n
t)
Sensor
w
e
i
gh
t
A
pp
lica
t
i
on
No
t
e
Fits through
m
o
un
t
i
ng
h
o
l
e
*
M
a
t
e
r
i
a
l
den
s
iti
y
g/l
(
l
b
/
ft
3
)
M
a
t
e
r
i
a
l
c
o
n
s
is
t
en
c
e
Angle o
f
r
epose
M
ax
.
p
r
o
c
ess
t
e
m
p.
T
hr
ea
d
F
lange
1
1/2"
3"
2"
3"
DN100
/ 4"
P
V
C
witout
p
i
n
>3
00
(
18
)
g
r
a
n
ul
a
t
e
fl
at
80
°
C
(
176
°
F)
Standard
w
e
i
gh
t
•
P
V
C
with
p
i
n
>3
00
(
18
)
g
r
a
nu
l
a
t
e,
p
ow
der
s
t
eep
80
°
C
(
176
°
F)
The pin penetrates into the material and
a
v
o
i
ds
slipping or tilting of the sensor weight on
t
h
e
steep bulk su
r
f
a
c
e.
•
Stainl.
s
t
ee
l
>3
00
(
18
)
g
r
a
nu
l
a
t
e,
p
ow
der
flat,
steep
250
°
C
(4
82
°
F)
The pin penetrates into the material and
a
v
o
i
ds
slipping or tilting of the sensor weight on
t
h
e
steep bulk su
r
f
a
c
e.
•
•
•
•
•
C
l
aw
>2
00
(
12
)
coarse
(
e
.
g
.
stones)
s
t
eep
250
°
C
(4
82
°
F)
Avoids slipping or tilting on the steep bu
l
k
su
r
f
a
c
e.
•
Folding
c
ove
r
>2
0
(
1.2
)
light
p
o
wd
e
r
flat,
steep
80
°
C
(
176
°
F)
Big surface prevents the sensor weight
f
r
o
m
sinking into the
m
a
t
e
r
i
a
l
.
•
•
•
•
•
S
pid
e
r
>
40
(1
.4
)
light
p
o
wd
e
r
flat,
steep
250
°
C
(4
82
°
F)
Big surface prevents the sensor weight
f
r
o
m
sinking into the
m
a
t
e
r
i
a
l
.
•
B
ag
>3
00
(
18
)
g
r
a
nu
l
a
t
e,
p
ow
der
fl
at
80
°
C
(
176
°
F)
Prevents damage of the conveying screw. To
be filled with bulk m
a
t
e
r
i
a
l
.
•
F
lo
a
t
-
liquids o
n
l
y
-
80
°
C
(
176
°
F)
To be filled with
m
a
t
e
r
i
a
l
.
*
The above mentioned data is a guideline and is valid for material which has settled after
filli
ng
.
During the filling the bulk density can change (e. g. for fluidised
m
a
t
e
r
i
a
l
)
.
PV
C
without
p
i
n
PV
C
with
p
i
n
S
t
ai
nle
ss
s
t
ee
l
C
l
aw
Fo
ldi
ng
c
o
v
e
r
B
ag
F
loat
Sp
i
de
r
page
G
12
gi010412
PB
3000
Continuous level measuring sys
t
e
m
PB
3000
Technical information
/
Instruction
m
a
nu
a
l
Plum
bob
®
Options
/
A
cce
sso
r
i
e
s
O
p
t
io
ns
Window in lid
a
nd
external start
bu
tt
o
n
Enables to see the display through the closed lid and
t
o
start a measurement without opening the
li
d
.
Material of the window: break-proof g
l
ass
.
Drawing see page
G
5
A
cc
es
s
o
r
i
es
PB
9000
Remote b
o
x
(Panel
m
o
un
t
i
ng
)
Connecting up to 10 units with Modbus RTU
n
e
t
w
o
rk
.
F
ea
t
u
r
e
s
:
•
P
ro
g
r
a
mm
i
ng
of
the
Plumbob
un
i
t
s
•
Display of
le
v
e
l
•
Start of
measurement
•
Display of
d
i
a
gn
o
s
t
i
c
s
i
n
f
or
m
a
t
i
o
n
PB 9000
P
a
n
e
l
Technical d
a
t
a
:
•
PB
9000
works
as a
Modbus
master
•
T
o
u
c
hp
a
n
e
l
•
Power
s
upp
l
y
:
24
V
DC
+-10%
10W
or
85
..
264
V
+-
0
%
50
-
60
H
z
10
V
A
•
A
mb
ie
nt
temperature: 0 ..
+
50
°
C
(
32
..
+
122
°
F
)
•
I
ng
r
e
ss
p
ro
t
e
c
t
i
o
n
:
I
P
65
•
I
n
s
t
a
ll
a
t
i
o
n
only in
N
o
n
-
H
a
z
a
r
d
o
u
s
areas
p
e
r
m
i
tt
e
d
PB
9000
Remote
B
o
x
(Wall m
o
un
t
i
ng
)
Included parts:
For easy installation and proper functioning of
t
h
e
Modbus n
e
t
w
o
rk
•
Biasing network (with Terminal
r
e
s
i
s
t
o
r
)
:
Stabilizer for Modbus
c
o
mm
un
i
c
a
ti
o
n
.
Supports the needed biasing voltages to ensure a
p
r
o
p
e
r
function in a network with long installed
c
a
ble
s
.
Termination resistor is needed for the beginning of
t
h
e
Modbus n
e
t
w
o
rk
.
•
Terminal
P
l
ug
Supplies screwing terminals for connection between
PB
9000 panel and Biasing n
e
t
w
o
rk
•
A
C
/
D
C
c
o
n
v
e
r
t
e
r
U
s
e
d
,
if AC
power
s
upp
l
y
i
s
selected
Implementation of PB 9000 panel in a wall
m
o
un
t
e
d
e
n
c
losu
r
e
.
Material: PC (fibre glass
r
e
i
n
f
o
r
c
e
d
)
Biasing network (with Termination resistor)
i
m
ple
m
e
n
t
e
d
.
A
C
/
D
C
converter (if AC power supply is
se
le
c
t
e
d
)
i
mpl
e
m
e
n
t
e
d.
Biasing network
Terminal
P
l
ug
DINrail
35
moun
ti
ng
A
C
/
D
C
c
o
nv
e
r
t
e
r
DINrail
35
moun
ti
ng
PB
3000
gi010412
page
G
13
Continuous level measuring sys
t
e
m
PB
3000
Technical information
/
Instruction
m
a
nu
a
l
Plum
bob
®
A
cc
es
s
o
ries
Extension cables
•
For connecting the Remote Box PB
9000
•
For wiring a Modbus
n
e
t
w
o
rk
•
Notes for
c
h
oo
s
i
ng
the
r
i
ght
cable
see
chapter
"
E
le
c
t
r
i
c
a
l
I
n
s
t
a
ll
a
t
i
o
n
"
•
It is generally recommended to protect
PVC
signal cables from UV
influence by installing them in a pipe or h
ose
.
Shielded c
a
b
l
e
Functionality up to
50m
Cross
s
e
c
t
i
o
n
2x 0,34mm
2
(AWG22),
common
s
h
ie
l
d
Capacitance 140nF/km (between wires)
/
150nF/km (wire to
s
hie
l
d
)
-30°C
(
-
22
°
F
)
to
70°C
(
158
°
F
)
,
PVC
(LiYC
Y
)
Twisted pair c
a
b
l
e
Functionality up to
1000m
T
w
i
s
t
e
d
p
a
i
r
i
n
s
t
r
um
e
nt
cable, common
s
h
ie
l
d
Cross
s
e
c
t
i
o
n
2x 0,34mm
2
(
AW
G
22
)
Impedance 120
O
h
m
s
Capacitance
40nF/km
-40°C
(
-
40
°
F
)
to
75°C
(
167
°
F
)
,
P
V
C
Protection h
os
e
for installation of extension cables in
ATEX Zone 21
ava
il
a
ble
Weather protection cover
If
the
un
i
t
i
s
used
outdoors,
theuse
of
theweather
protection cover is recommended. It protects the d
ev
i
c
e
from all atmospheric influences such
as
•
r
a
i
n
water
•
c
o
nd
e
n
s
a
t
i
o
n
water
•e
x
c
e
ss
i
v
e
l
y
h
i
gh
temperatures
•e
x
c
e
ss
i
v
e
l
y
low
temperatures
in
w
i
nt
e
r
M
a
t
e
r
i
a
l
:
PE, weather
and
temperature
stable
For use in Hazardous Locations only permitted for
Z
o
n
e
22 or Division
2.
Mounting set
S
ea
li
ng
s
,
screws
and
washers
for fixing
the
un
i
t
on
a
fl
a
ng
e
.
page
G
14
gi010412
PB
3000
Continuous level measuring sys
t
e
m
PB
3000
Technical information
/
Instruction
m
a
nu
a
l
Plum
bob
®
M
oun
t
i
ng
General Safety
I
n
s
t
ruc
t
i
o
n
s
Process pressure
Improper installation may result in loss of process p
r
ess
u
r
e
.
Chemical
r
e
s
i
s
t
a
nce
against the
m
ed
i
u
m
Materials of construction are chosen based on their chemical compatibility (or inertness) for general pu
r
p
oses
.
For exposure
to
s
p
e
c
i
fi
c
e
n
v
i
ro
nm
e
nt
s
,
check
w
i
th
c
h
e
m
i
c
a
l
compatibility charts before
i
n
s
t
a
lli
ng
.
Mounting location
The right mounting place is significant for a proper function. Observe mounting
i
n
s
t
r
u
c
ti
o
n
s
.
Vibrations
Avoid mounting in applications with strong vibration. Use rubber mounts for absorption in case of
li
gh
t
v
i
b
r
a
t
ions
.
Additional Safety Instructions for Hazardous
Lo
c
a
t
i
o
n
s
Installation regulations
For devices to be used in Hazardous Locations the respective valid installation regulations must be o
b
se
r
ve
d
.
Sparks
The
i
n
s
t
a
ll
a
t
i
o
n
has to be
done in
a
way,
that
m
e
c
h
a
n
i
c
a
l
friction or
i
mp
a
c
t
does
not
cause
sparks
between
the aluminium enclosure and
s
t
ee
l
.
Mounting
i
n
s
t
ruc
t
i
o
n
s
Mounting position
•
The
un
i
t
i
s
mounted vertically on
the
silo. Max.
d
e
v
i
a
t
i
o
n
i
s
2°.
•
There must
be at least
200mm
(
7.87
“
)
space
for
the
sensor
w
e
i
ght
to
move down in
case
of
a
full
s
il
o
.
Observe
the
bottom of
the
sensor weight
at
"upper stop p
o
s
i
t
i
o
n
"
(
d
i
m
e
n
s
i
o
n
s
see page
G4
-
G
6
)
.
•
The socket p
i
p
e
of
the
un
i
t
must
protude
at least
50mm (2")
i
nt
o
t
h
e
silo. A version with
l
o
ng
e
r
socket pipe is
ava
il
a
ble
.
•
Proper movement of
the
sensor weight must
be
guaranteed, even
if
the
sensor
w
e
i
ght
o
s
c
ill
a
t
e
s
.
Observe enough d
i
s
t
a
n
c
e tothe
silo wall,
s
t
a
n
c
h
i
o
n
s
and
built-in fittings.
PB
3000
gi010412
page
G
15
Continuous level measuring sys
t
e
m
PB
3000
Technical information
/
Instruction
m
a
nu
a
l
Plum
bob
®
M
o
u
nt
i
ng
Measurement during
fi
lli
ng
of the
s
il
o
Filling of the silo while measuring might cover the sensor weight with bulk material. Measurements during
filli
ng
are
p
o
ss
i
b
le
,
if there
i
s
enough d
i
s
t
a
n
c
e tothe
i
n
f
ee
d
,
so that
no m
a
t
e
r
i
a
l
can
fall on
the
sensor
w
e
i
ght
.
Sensor
w
e
i
gh
t
"Bag" and
"
F
l
o
a
t
"
•
The weights
are
filled
w
i
th
p
l
a
s
t
i
c
g
r
a
nu
l
a
t
e
or
sand.
They
s
h
a
ll
be
filled on
s
i
t
e
w
i
th
bulk
m
a
t
e
r
i
a
l
or
li
qu
i
d
,
which is not critical
if
mixed with the material stored in the silo. Consider ageing of the
m
a
t
e
r
i
a
l
.
•
When filling, observe
the
t
o
t
a
l
w
e
i
gth
of
the
sensor: rope
v
e
r
s
i
o
n
1.0kg
(
2.2
l
b
s
)
,
tape
v
e
r
s
i
o
n
2.1kg
(
4.6
l
b
s
)
Sealing
•
Arubber
s
ea
l
must
be used to
t
i
ght
e
n
the
fl
a
ng
e
.
•
C
l
o
s
e
both lids of
thee
n
c
l
o
s
u
r
e
t
i
ght
l
y
.
Sensor weight
w
h
i
ch
does not fit
t
h
r
o
ugh
the mounting h
o
l
e
The sensor weight must be removed b
e
f
o
r
e
placing the unit on the silo. An inlet close to the
fi
x
i
ng
loacation and a hook is
n
ee
d
e
d
.
See installation manual for more details.
H
o
ok
page
G
16
gi010412
PB
3000
Continuous level measuring sys
t
e
m
PB
3000
Technical information
/
Instruction
m
a
nu
a
l
Plum
bob
®
Electrical
i
n
s
t
alla
t
i
o
n
General Safety
I
n
s
t
ruc
t
i
o
n
s
Handling
I
n
case
of
i
mp
ro
p
e
r
h
a
nd
li
ng
or
h
a
nd
li
ng
m
a
l
p
r
a
c
t
i
c
e
,
thee
le
c
t
r
i
c
safety of
the
d
e
v
i
c
e
cannot
be guaranteed.
Installation regulations
The local regulations or
VDE
0100 (Regulations of German Electrotechnical Engineers) must be o
b
se
r
ve
d
.
Fuse
Use a fuse as stated in the connection
d
i
a
g
r
a
m
s
.
RCCB protection
I
n
case
of
a
f
a
u
l
t
,
the
s
upp
l
y
vo
l
t
a
g
e
must
be a
ut
o
m
a
t
i
c
a
ll
y
s
w
i
t
c
h
e
d
off by
a
RCCB
p
ro
t
e
c
t
i
o
n
s
w
i
t
c
h
to
protect against indirect contact with dangerous
vo
lt
a
g
es
.
Power supply switch
A voltage disconnection switch must be provided near the d
ev
i
c
e
.
Wiring diagram
Theelectrical connections are made in accordance with the wiring d
i
a
g
r
a
m.
Supply voltage
Comparethe supply voltage applied with the specifications given on the name plate before switching
t
h
e
device
o
n
.
Cable gland
Make sure that the screwed cable gland safely seals the cable and that
it
is tight (danger of water
i
n
t
r
u
s
i
o
n
)
.
Cable glands that are not used have to be sealed with a blanking ele
m
e
n
t
.
Conduit system
I
n
case
of
u
s
i
ng
a
c
o
ndu
i
t
system
(with NPT
thr
ea
d
)
i
n
s
t
ea
d
of
a
cable g
l
a
nd
the
r
e
gu
l
a
t
i
o
n
s
of
the
c
o
unt
r
y
,
where
the
un
i
t
i
s
i
n
s
t
a
l
le
d
,
must
be
observed. The
c
o
ndu
i
t
must have
a
tapered thread either
NPT
1/2“or
NPT
3
/
4
”
in accordance with the unit and ANSI B 1.20.1. Not used inlets must be closed tight with a
m
e
t
a
l
blanking
ele
m
e
n
t
.
Field wiring cables
All field wirings must have insulation suitable for at least 250V AC. The temperature rating must be at
le
as
t
80°C
(
176
°
F)
.
Relay protection
Provide protection for relay contacts to protect the device against inductive load
s
u
r
g
es
.
Protection against
s
t
a
t
i
c
c
har
g
i
ng
The housing of the unit must be grounded to avoid static charging of the unit. This
is particularly important
for applications with pneumatic conveying and
non-metallic c
o
n
t
a
i
n
e
r
s
.
Additional Safety Instructions for Hazardous
Lo
c
a
t
i
o
n
s
External equ
i
p
o
t
en
t
ial
bonding
t
e
rmi
n
al
Connect
toe
qu
i
p
o
t
e
nt
i
a
l
bonding of the p
l
a
n
t
Field wiring
A
s
t
r
a
i
n
relief must
be
p
r
ov
i
d
e
d
for
the
field wiring cables, if
the
d
e
v
i
c
e
i
s
i
n
s
t
a
l
le
d
w
i
th
the
factory
p
r
ov
i
d
e
d
cable g
l
a
nd
s
.
Cable glands for
A
T
E
X
Hazardous
L
o
c
a
t
i
o
n
s
The
used
entry d
e
v
i
c
e
s
and
b
l
a
nk
i
ng
elements must have
an
adequate type app
r
ov
a
l
and a temperature
range as defined in the technical data of the unit. In addition they shall be suitable for the conditions
a
nd
correctly installed. Where available the provided original parts of the manufacturer must be u
se
d
.
Conduit system
f
o
r
ATEX and
F
M
Hazardous
L
o
c
a
t
i
o
n
s
In addition the regulations of the country must be observed. The used flameproof seals and b
l
a
nk
i
ng
elements must have
an
adequate type app
r
ov
a
l
anda
temperature range
as
defined in
the
t
e
c
hn
i
c
a
l
data
of the unit. In addition they shall be suitable for the conditions and correctly installed. Whereavailable
t
h
e
provided original parts of the manufacturer must be u
se
d
.
Comissioning
/
opening
t
he
li
d
C
o
m
i
ss
i
o
n
i
ng
only, when there
are
no
dust
d
e
p
o
s
i
t
s
or
s
w
i
r
l
s
present.
PB
3000
gi010412
page
G
17
Continuous level measuring sys
t
e
m
PB
3000
Technical information
/
Instruction
m
a
nu
a
l
Plum
bob
®
Electrical
i
n
s
t
alla
t
i
o
n
Terminal
l
o
c
a
t
i
o
n
D
i
sp
l
ay
0/
4
-
20m
A
Start
i
npu
t
Full detector
i
npu
t
Modbus RTU
Profibus
D
P
R
e
la
is
El. counting pu
l
s
e
P
r
o
t
e
c
ti
ve
c
o
ndu
c
t
o
r
t
e
rmi
n
a
l
P
o
w
e
r
sup
pl
y
PB
3000-
Power supply and Signal input /
o
ut
p
ut
Power supply
AC
v
e
r
s
i
o
n
DC
v
e
r
s
i
o
n
0.14 .. 2.5mm
2
(AWG 26 ..
14
)
AC or DC
s
upp
l
y
depending
o
n
ordered
ve
r
s
i
o
n
98 .. 253V 50-60Hz
20
-
28
V
D
C
Signal input:
Start of measurement
Start contact
Start
+
24
V
a
lt
e
r
n
a
t
iv
e
Measurement interruption
i
n
case
of filling.
If
used,
r
e
m
o
ve
factory provided
c
o
nn
e
c
ti
o
n
.
0.14 ..
2.5mm2
(AWG 26 ..
14
)
S
i
gn
al
desc
ri
p
t
i
o
n
:
See page
G
22
page
G
18
gi010412
PB
3000
Continuous level measuring sys
t
e
m
PB
3000
Technical information
/
Instruction
m
a
nu
a
l
Plum
bob
®
Electrical
i
n
s
t
alla
t
i
o
n
Signal input:
Full detector
0.14 ..
2.5mm2
(AWG 26 ..
14
)
S
i
gn
al
desc
ri
p
t
i
o
n
:
See page
G
22
Signal output:
0/4-20mA
max. 500
O
h
m
a
c
t
i
v
e
,
i
s
o
l
a
t
e
d
0.14 .. 2.5mm
2
(AWG 26 ..
14
)
S
i
gn
al
desc
ri
p
t
i
o
n
:
See page
G
22
Signal output:
Relay
R
e
l
ay
1
Relay2 Relay3
R
e
l
a
y4
0.14 .. 2.5mm
2
(AWG 26 ..
14
)
Fuse: max.
2
A
max.
250
V
A
C
,
2
A
,
500
V
A
,
non
i
ndu
c
t
i
v
e
S
i
gn
al
desc
ri
p
t
i
o
n
:
See page
G
22
Signal output:
Electronic
counting
pulse
Optocoupler
N
o
t
e:
Reset pulse is done with Relay
2
0.14 .. 2.5mm
2
(AWG 26 ..
14
)
Fuse: max.
63m
A
max.
30
V
DC, max.
25
m
A
S
i
gn
al
desc
ri
p
t
i
o
n
:
See page
G
23
PB
3000
gi010412
page
G
19
Continuous level measuring sys
t
e
m
PB
3000
Technical information
/
Instruction
m
a
nu
a
l
Plum
bob
®
Electrical
i
n
s
t
alla
t
i
o
n
PB
3000
Modbus
n
e
t
w
o
rk
Profibus DP
n
e
t
w
o
rk
Wiring according to
P
r
o
fi
bu
s
DP
s
t
a
nd
a
r
d
s
Setting Biasing
and
Termination Resistor
For use of PB 3000 units in a
external Modbus or
P
r
o
fi
bu
s
network, it
i
s
p
o
ss
i
b
le
to
set Biasing and
T
e
r
m
i
n
a
ti
o
n
Resistor on each unit as
required.
B
ia
s
i
ng
OFF
*
OFF
ON
T
e
r
m
i
n
a
ti
o
n
R
es
i
s
to
r
OFF
*
ON
ON
*factory
p
r
ov
i
d
e
d
page
G
20
gi010412
PB
3000
Continuous level measuring sys
t
e
m
PB
3000
Technical information
/
Instruction
m
a
nu
a
l
Plum
bob
®
Electrical
i
n
s
t
alla
t
i
o
n
Remote Box PB
9000-
Internal wiring and power
s
upp
l
y
Panel mounting
version
PB 9000
p
a
n
e
l
No
t
e
:
PB 9000
CO
M1:
Modbus D1
=
P
i
n
1 and
4.
Modbus D0
=
Pin 8 and
9.
Cache
=
sh
i
e
l
d
.
Terminal plug
t
o
be connected
t
o
CO
M1
Use shielded
c
a
ble
No
t
e
:
T
e
r
m
i
n
a
l
plug
i
n
t
e
r
n
a
l
c
o
nn
e
c
ti
o
ns
:
Pin 1 and
4.
Pin 8 and
9.
Biasing
ne
t
wo
rk
Terminal
3
-
5:
Modbus connections
t
o
PB 3000 units (see
n
ex
t
p
a
g
e)
If
r
e
qu
i
r
e
d
:
Power
s
upp
l
y
can
be taken from one of the
PB
3000 power supply
t
e
r
m
i
n
a
l
s
(see next
p
a
g
e
)
.
85 .. 264
V
50-60Hz
alternative*
24V D
C
Fuse
0,63
A
..
1,6
A
*
A
C
/
D
C
c
o
n
ve
r
t
e
r
:
U
s
e
d
,
if AC
power
s
upp
l
y
i
s
se
l
e
c
ted
Wall mounting
version
Connections to PB 9000
p
a
n
e
l
are factory p
r
ov
i
d
e
d
Biasing
ne
t
wo
rk
Terminal
3
-
5:
Modbus connections
t
o
PB 3000 units (see
n
ex
t
p
a
g
e)
85 .. 264
V
24V D
C
Fuse
0,63
A
..
1,6
A
If
r
e
qu
i
r
e
d
:
Power
s
upp
l
y
can
be taken from one of the
PB
3000 power supply
t
e
r
m
i
n
a
l
s
(see next
p
a
g
e
)
.
50-60Hz
alternative*
*
A
C
/
D
C
c
o
n
ve
r
t
e
r
:
U
s
e
d
,
if AC
power
s
upp
l
y
i
s
se
l
e
c
ted

Other Hycontrol Measuring Instrument manuals

Hycontrol DP220 User manual

Hycontrol

Hycontrol DP220 User manual

Hycontrol Microflex LR Integral User manual

Hycontrol

Hycontrol Microflex LR Integral User manual

Popular Measuring Instrument manuals by other brands

MKS e-Vision+ user manual

MKS

MKS e-Vision+ user manual

VeEX VePal CX350 user manual

VeEX

VeEX VePal CX350 user manual

Dover OPW SiteSentinel iTouch M1500 installation guide

Dover

Dover OPW SiteSentinel iTouch M1500 installation guide

Bender NGRM700 manual

Bender

Bender NGRM700 manual

Astrol Electronic BAT-FLEX manual

Astrol Electronic

Astrol Electronic BAT-FLEX manual

FTS SDI-RADAR-300WL operating manual

FTS

FTS SDI-RADAR-300WL operating manual

Johnson Controls 802SB quick start guide

Johnson Controls

Johnson Controls 802SB quick start guide

TytoCare TytoPro user guide

TytoCare

TytoCare TytoPro user guide

Neptune HP PROTECTUS III Installation and maintenance guide

Neptune

Neptune HP PROTECTUS III Installation and maintenance guide

Center C315 instruction manual

Center

Center C315 instruction manual

Mastech MS6580 user manual

Mastech

Mastech MS6580 user manual

Martel Beta PTC8001 user manual

Martel

Martel Beta PTC8001 user manual

ITI e-Gauge-lite Assembly manual

ITI

ITI e-Gauge-lite Assembly manual

Tektronix P6207 instruction manual

Tektronix

Tektronix P6207 instruction manual

Koso XR-SR N instructions

Koso

Koso XR-SR N instructions

IBA MBox manual

IBA

IBA MBox manual

Schmidt DHT-3 instruction manual

Schmidt

Schmidt DHT-3 instruction manual

SICK InspectorP61x operating instructions

SICK

SICK InspectorP61x operating instructions