hyfire HFW-BSB-05 User manual

2) Insert the secondary battery into its housing (picture 5).
3) Insert the primary battery into its housing; the visual LED indicator switches on accordingly (see “Power up” in table 2 and
picture 6).
Ensure that both battery’s polarity are correct!!!
4) When the wire to wireless translator (by itself or piloted by the Wirelex) is searching for a new device for linking, move the “Link-program”
switch to position 1 in order to initiate communication with the translator module (picture 7); the visual LED indicator switches on accordingly
(see “Programming and linking to the system” in table 2).
IMPORTANT NOTE!
Programming is considered to be completed successfully only if there is an indication of programming success on the wire to wireless trans-
lator or on the window of the Wirelex program.
If the linking and programming operation fails, check if mistakes were made with the wire to wireless translator or the Wirelex, remove the
batteries, change the switch over ON / 1 alternatively a few times in order to discharge the internal capacitor and then start again from point
1) re-performing the linking procedure.
COMMUNICATION QUALITY ASSESSMENT
It is possible to assess the wireless communication quality between the wireless sounder base and the wire to wireless translator / wireless
expander by using a testing feature built in the device.
After a successful linking operation, by changing over the “Link-programming” switch on the ON position, the device’s LED will start blinking
according to table 3.
Always remember to reposition the switch to 1 after the assessment operation: device will NOT work operatively while the switch
is changed over the ON position.
DEVICE’S PLACEMENT
For specific information regarding detector and device’s spacing, placement and special applications refer to your specific n ational stand-
ards.
It is strongly advised to mount the wireless sounder base as far as possible from metal objects, metal doors, metal window openings, etc. as
well as cable conductors, cables (especially from computers), otherwise the operating distance may greatly drop. The sounder base should
not be installed near electronic devices and computer equipment that can interfere with the reception’s quality.
1) Select the position of the sounder base before installing and fixing it.
Verify, from that position, that the communication between the device and the wire to wireless translator / wireless expander is
correctly established and working (see the COMMUNICATION QUALITY ASSESSMENT paragraph).
2) Install and fix the sounder base in the selected position with the provided screws (picture 8).
3) Select the sounder’s base output’s tone and volume (see the OUTPUT SETTINGS paragraph).
4) Insert the wireless sensor onto the sounder base, then secure it by turning it clockwise.
OUTPUT SETTINGS
Output’s characteristics when the wireless base sounder is activated (tone and volume) can be selected through the DIP switch selectors
located in the inner area of the sounder base (see picture 9).
In order to change over the switches use the tip of a pen or a little screwdriver.
For the selection of the output settings refer to picture 9, table 4 and table 5.
BATTERY FAULTS
If a battery fault condition is detected on the wireless base sounder, a fault message is sent to the control panel via the wire to wireless
translator / wireless expander.
TESTING
In order to test the functionality of the installed wireless sounder base, the following test must be performed: activate an alarm condition on
the control panel (by a call-point or sensor in the installed system): the control panel will transmit an activation message to the device via
wire to wireless translator / wireless expander and activate the sounder base. After each test the device must be reset by the specific com-
mand on the control panel or on the wire to wireless translator (see the RESET paragraph). If the test fails check whether the batteries are
charged, if mistakes were done previously or even if the system is activated. If the wireless sounder base functionality is hopeless, send
back the device to your distributor for repair or substitution.
All devices must be tested after installation and, successively, on a periodic basis.
GENERAL DESCRIPTION
The wireless sounder base is a device that activates its output when ordered so by the control panel in the event of fire alarms. The activa-
tion command is sent from the control panel to the base sounder through the wire to wireless translator interface module and other possible
wireless expander modules. Communication between the sounder base and the translator / expanders is obtained through the “Sagittarius”
wireless, analogue-intelligent bidirectional protocol. Device’s radio communication meets European standard EN 54-25.
This sounder is equipped with a supplementary visual indicator that reinforce the audible warning.
Wireless sounder base is designed to act as a supporting mean for the installation of Sagittarius wireless detectors.
GENERAL OVERVIEW
VISUAL LED INDICATOR
The wireless sounder base is equipped with a bicolour red - green LED (picture 3) that provides visual indication for functional conditions as
indicated in table 2.
DEVICE’S POWER SUPPLY AND LINKING
The linking operation permits the configuration of the wireless sounder base on the wireless system.
The linking operation described below does not change if made directly from the wire to wireless translator module’s interface or from the
Wirelex PC configuration program.
1) Move the “Link-program” switch to position ON (picture 4).
TECHNICAL SPECIFICATIONS *****
Operating frequency range 868 MHz
Radiated power 5 dBm (3 mW)
Usable operating frequency channels 7
Radio signal’s modulation type FSK
Communication range with wire to
wireless device or wireless expander
device
200 m in open space *
Main and secondary battery types CR123A (3 V & 1.2 Ah)
Approved battery voltage range 2.75V - 3.20V
Estimated battery life **
>3 years; remains operational for up to 60
days from first appearance of the low
battery warning ***
Alarm current 110 mA
Operating temperature range from –10 °C to +55 °C
Maximum tolerated humidity - with no
condensing 95 % RH
Maximum volume range @ 1m -
selectable
between 70 dBa and 95 dBa at max volume
depending upon angle and tone selection (refer
to volume plots under OUTPUT OPERATION-
AL PERFORMANCE SPECIFICATIONS)
Device output tone’s frequency range 440 Hz to 2900 Hz
Ingress protection rating 21C ****
Device’s dimensions 145 mm x 66 mm
Device’s weight 260 g
* Ideal operating range: may vary consistently according
to environmental conditions.
** When a low battery condition is indicated, both, main
and secondary, batteries must be changed altogether.
*** This lifespan value refers to the device being set with a
message transmission period of 12 seconds; tests are not
considered in this estimation.
**** Type A for indoor use only.
***** Check latest version of document TDS-SGRBX for
further data, obtainable from your supplier.
HFW-BSB-05
WIRELESS SOUNDER BASE
WITH SUPPLEMENTARY VISUAL INDICATOR
Picture 1 - wireless
base sounder overview
Picture 2 -
wireless base
sounder top view
Table 1
WARNINGS AND LIMITATIONS
Our devices use high quality electronic components and plastic materials that are highly resistant to environ-
mental deterioration. However, after 10 years of continuous operation, it is advisable to replace the devices in
order to minimize the risk of reduced performance caused by external factors. Ensure that this device is only
used with compatible control panels.
Detection systems must be checked, serviced and maintained on a regular basis to confirm correct operation.
Smoke sensors may respond differently to various kinds of smoke particles, thus application advice should be
sought for special risks. Sensors cannot respond correctly if barriers exist between them and the fire location
and may be affected by special environmental conditions.
Refer to and follow national codes of practice and other internationally recognized fire engineering standards.
Appropriate risk assessment should be carried out initially to determine correct design criteria and updated
periodically.
WARRANTY
All devices are supplied with the benefit of a limited 3 year warranty relating to faulty materials or manufacturing
defects, effective from the production date indicated on each product.
This warranty is invalidated by mechanical or electrical damage caused in the field by incorrect handling or
usage.
Product must be returned via your authorized supplier for repair or replacement together with full information on
any problem identified.
Full details on our warranty and product’s returns policy can be obtained upon request.
Picture 3 - wireless
base sounder detailed
view of the inner area
Device status Green LED Red LED
Power up 1 second green, then 0.5 second red for 4 times
Programming and linking to the system Blinking until linking and
programming is completed
Program - link failure - Continuously on
Normal condition - -
Lost link with the wire to wireless translator / wire-
less expander 0.5 second on and
1 second off
Table 2
Picture 4 - “Link-program” switch: ON position
LINK-PROGRAM
SWITCH
SECONDARY
BATTERY
LODGEMENT
PRIMARY BATTERY
LODGEMENT
LED INDICATOR
ARGUS SECURITY S.R.L.
Via del Canneto, 14
34015 Muggia (TS)
Italy
17
EN 54-25:2008
EN 54-3: 2001 + A1:2002; +
A2:2006
HFW-BSB-05
This product is not intended
to comply with the require-
ments of EN 54-23
For use in compatible fire
detection and alarm system
Type A for indoor use only
Picture 5 - secondary
battery inserted
Picture 6 - primary and secondary
batteries inserted
Picture 7 - “Link-program” switch: 1 position
Communication quality Assessment Device’s indication
No connection Fail Two red blinks
Link margin is less than 10 dB Poor One red blink
Robust communication with link margin from 10 dB to 20 dB Good One green blink
Robust communication with link margin over 20 dB Excellent Two green blinks
Table 3
Picture 8 - position of the holes for
screw’s insertion
Volume Volume DIP
switch setting
LOW A + B
HIGH A + D
Table 4
Picture 9 - tone and
volume selection DIP
switch selectors
STERLING SAFETY SYSTEMS, Unit B12a, Holly Farm Business Park, Honiley, Warwickshire, CV81NP www.sterlingsafety.co.uk [email protected] L20-SGRBVL-1400 (vP.1)

RESET
To reset the wireless sounder base from an activated or a fault condition, it is necessary to:
1) solve the cause of the abnormal condition
2) send the reset command from the control panel or from the wire to wireless translator.
Performing sequentially those two operations, the device’s output and/or fault condition will deactivate / resolve.
INSTALLING A WIRELESS SENSOR ON THE SOUNDER BASE
To install a wireless detector on the wireless sounder base apply the following procedure:
1) Insert the detector onto the base.
2) Fix the detector to the base by turning it clockwise until a secure and safe stop is reached.
LOCKING THE WIRELESS SENSOR ONTO THE BASE SOUNDER
In order to avoid tampering, the wireless sensor can be locked onto the base sounder; use the supplied locking Allen screw inserted in its
side hole, after having installed the sensor and secure it through a suitable Allen key (picture 10).
MAINTENANCE
1) Before starting any maintenance work, isolate and disable the system, in order to avoid accidental and unwanted fault detection condi-
tions.
2) Remove the wireless sensor from the wireless sounder base.
4) Perform the planned necessary maintenance operations (e.g. batteries substitution).
5) After the base has been serviced, reinstall the wireless sensor correctly onto it, re-apply power to the system and check correct operation
as described under the TESTING paragraph.
OUTPUT OPERATIONAL PERFORMANCE SPECIFICATIONS
Table 5
Picture 10 - locking of
the sensor on the base
sounder
* Tones in bold are LPCB certified
Picture 11 - Continuous tone
dB(A) output
Picture 12 - Warble tone
dB(A) output
Picture 13 - DIN tone
dB(A) output
No. Tone Description Switch 23456
1Warble Tone * 800Hz for 500ms, then 1000Hz for 500ms 11101
2Continuous tone * 970Hz continuous 01011
3Slow Whoop (Dutch) * 500Hz-1200Hz swept for 3500ms, then off for 500ms 10101
4German DIN tone * 1200Hz-500Hz swept every 1000ms (1Hz) 00111
5Alternate HF slow sweep 2350Hz-2900Hz swept every 333ms (3Hz) 10010
6Alternative warble 800Hz for 250ms, then 960Hz for 250ms 11110
7Alternative warble 500Hz for 250ms, then 600Hz for 250ms 11100
8Analogue sweep tone 500Hz-600Hz swept every 500ms (2Hz) 10100
9Australian Alert (Intermittent tone) 970Hz for 625ms, then off for 625ms 10001
10 Australian Evac (slow whoop) 500Hz-1200Hz for 3750ms, then off for 250ms 10110
11 FP1063.1-Telecom 800Hz for 250ms, then 970Hz for 250ms 00001
12 French tone AFNOR 554Hz for 100ms, then 440Hz for 400ms 00101
13 HF Back up Interrupted tone 2800Hz for 1000ms, then off for 1000ms 11011
14 HF Back up Interrupted tone – fast 2800Hz for 150ms, then off for 150ms 11001
15 HF Continuous 2800Hz continuous 01001
16 Interrupted tone 800Hz for 500ms, then off for 500ms 01111
17 Interrupted tone medium 1000Hz for 250ms, then off for 250ms 01101
18 ISO 8201 LF BS5839 Pt 1 1988 970Hz for 500ms, then off for 500ms 01110
19 ISO8201 HF 2850Hz for 500ms, then off for 500ms 01100
20 LF Back up Alarm 800Hz for 150ms, then off for 150ms 11010
21 LF Buzz 800Hz-950Hz swept every 9ms (110Hz) 01010
22 LF Continuous tone BS5839 800Hz continuous 11000
23 LF Sweep 800Hz-1000Hz swept every 500ms (2Hz) 11111
24 Siren 2 way ramp (long) 500Hz-1200Hz rising for 3000ms, 1200Hz-500Hz falling for 3000ms 00000
25 Siren 2 way ramp (short) 500Hz-1200Hz rising for 250ms, 1200Hz-500Hz falling for 250ms 00010
26 Swedish all clear signal 660Hz continuous 00100
27 Swedish Fire signal 660Hz for 150ms, then off for 150ms 00110
28 Sweep tone (1 Hz) 800Hz-900Hz swept every 1000ms (1Hz) 10111
29 Sweep tone (3 Hz) 800Hz-970Hz swept every 333ms (3Hz) 10011
30 Sweep tone (9 Hz) 800Hz-970Hz swept every 111ms (9Hz) 01000
31 US Temporal Pattern HF 2900Hz for 500ms on, 500ms off (x3), then 1500ms off 00011
32 US Temporal Pattern LF 950Hz for 500ms on, 500ms off (x3), then 1500ms off 10000
Picture 14 - Slow Whoop (Dutch)
dB(A) output
STERLING SAFETY SYSTEMS, Unit B12a, Holly Farm Business Park, Honiley, Warwickshire, CV81NP www.sterlingsafety.co.uk [email protected] L20-SGRBVL-0001 (vP.1)
Other hyfire Security System manuals
Popular Security System manuals by other brands

Audio Contractor
Audio Contractor VAIE 2250 operating manual

First Alert
First Alert FA1660C Installation and setup guide

Stahl
Stahl 6161 Series operating instructions

DSC
DSC Digital Security Control PC158O instruction manual

CASTLE
CASTLE Euro 46 user manual

Fire Burglary Instruments
Fire Burglary Instruments XL-3 owner's manual