Hysolis Apollo 5K User manual

User Manual
Apollo 5K
Portable Solar Power Station

Contents
1.0 Introduction .........................1
2.0 Safety ...............................2
3.0 Initial Inspection . . . . . . . . . . . . . . . . . . . . .3
4.0 Product Features ................... 4
4.1 Top Panel . . . . . . . . . . . . . . . . . . . . . . 4
4.2 Front Panel ....................4
4.3 Back Panel. . . . . . . . . . . . . . . . . . . . . 5
4.4 Homepage UI Touchscreen ..... 6
4.5 Homepage UI Icons. . . . . . . . . . . . . 7
5.0 Installation ......................... 8
5.1 Overview ...................... 9
5.2 General Installation Guidelines 9
5.3 Single Unit Options. . . . . . . . . . . . . 9
5.4 Multi-unit Setup ...............15
6.0 Operation.......................... 26
6.1 Power-on Options. . . . . . . . . . . . . 26
6.2 Touchscreens . . . . . . . . . . . . . . . . . 30
7.0 Product Care. . . . . . . . . . . . . . . . . . . . . . . 49
8.0 Troubleshooting ...................49
9.0 Technical Specifications. . . . . . . . . . . . 53
10.0 Declarations . . . . . . . . . . . . . . . . . . . . . . . 54

1
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V 2.4A
QC 3.0
PD60W
12VDC
2A
AC OUTPUT
25AMAX
AC OUTPU T MAX 15A
1.0 Introduction
Thank you very much for purchasing the
Hysolis Apollo 5K unit! We designed this product
to help grant you energy independence. We have
the utmost confidence in this product’s
performance and quality. Please feel free to
contact us at Hysolis.com if you have any
questions. Enjoy using your Hysolis Apollo 5K,
and may it positively aect your future
endeavors!
The product has the following features:
• Dual-CPU Intelligent Control Technology manages energy input/output
• High-frequency pure sine wave output is clean and reliable for any load
• Wide input voltage range and consistent voltage output
• Three programmable working modes prioritize dierent energy needs:
• UPS mode: Utility Power first, a.k.a. “Pass-through AC Power”
• AC Fast Charge (AC F.C.) mode: 120V AC power Fast Charge,
500W-3,000W programmable
• Battery First mode: The solar charges the battery and grid. AC Power is
only used if battery is almost empty.
• Intelligent MPPT solar controller features over-charge & over-discharge
protection, current limiting charging, and multiple other safety protections
• Battery over-voltage and low-voltage protection, overload protection, short
circuit protection, over-temperature and under-temperature protection.
• A 4.3” touchscreen shows real-time running statuses at-a-glance
• Remote monitoring & control
• Compact and modular unit design for portability
• Smart Fan Control keeps the unit cool, safe, and reliable
• Multiple output power supply (120VAC/3000W, 12VDC/600W, 5VDC/120W)
• Unattended mode: If battery runs out, inverter auto-starts when solar power
is available.

2
2.0 Safety
All personnel engaged with installation, use, or maintenance of this product
must read, and understand the information in this manual. Please contact
customer service if there are any questions before operating this product.
• Inserting foreign objects into any of the product’s port or ventilation holes
may cause an electrical shock and result in death or serious injury. Never
insert foreign objects into any of the product’s port or ventilation holes.
• Improper connections between the unit and the power source may result in
exposure to electricity and could result in death or serious injury. A licensed
electrician is required to install the Apollo 5K as spacing installation involves
connecting the wires from your home circuit breaker box to the Apollo 5K
Wiring Box (optional purchase).
• Placement of the product near any heat sources may result in an explosion or
toxic fumes and could result in death or serious injury. Never place and
operate the product in an environment with flammable, explosive gas, or
smoke.
• Operation of the product in wet conditions may conduct electricity and
expose people and animals to electric shock resulting in minor injury or
death. Always turn the power to the unit OFF if is operating in wet conditions.
Let the unit dry completely and ensure the unit is in a safe environment
before turning the power to the unit on.
• This product utilizes high voltage solar array to charge. Exercise extreme
caution when handling high-voltage PV (solar) wires. Do not use if wires are
damaged. Use included Solar Input Breaker to connect to Apollo.
• Voltage may be present on PV (solar) Input when inverter is in operation.
WARNING
CAUTION
Only use a dry chemical powder fire extinguishing agent if the product is
exposed to flame or fire. Using a wet chemical fire extinguisher can conduct
electricity and cause an electric shock and may result in minor or moderate
injury as well as damage the product.

3
3.0 Initial Inspection
NOTICE
Inspect the product for damage during transit. Do not power the product ON.
Check the following items are in the box (Note: Cables are shipped separately
in the accessories box):
NOTICE
• Ensure proper ventilation while in use and do not obstruct fan openings.
Inadequate ventilation may cause permanent damage to the equipment.
• Vibrations and impacts during product operation may damage the unit and
lead to poor connectivity to the hardware inside. Do not move the product
during operation.
• Stacking anything on top of the power station either in storage or while in
use may cause damage the product. Do not stack anything on the product.
• Replacement of the internal battery or any other components of product by
anyone other than authorized personnel may result in damage to the
product. Always have authorized personnel perform hardware maintenance.
• AC charging cable
• DC charging cable
• Solar Input Breaker
• Ground cable and spike
• Wall-Outlet Adapter for AC charging
cable
• User Manual
• Apollo 5K Unit
Report any damage to the product to
the dealer and carrier. Contact Hysolis
customer service regarding any
missing items:
Phone: +1 (760) 410-5917
Email: suppor[email protected]

4
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V 2.4A
QC 3.0
PD60W
12VDC
2A
AC OUTPUT
25AMAX
AC OUTPUT MA X 15A
4.0 Product Features
Fig. 4.2 • Unit front panel
Fig. 4.1 • Unit top view
4.2 Front Panel
2. 12VDC Output 5210
Sockets (MAX 2A)
3. 12VDC Output Anderson
Plug (MAX 30A)
4. 12VDC Output Cigarette
Lighter Socket
(MAX 10A)
5. 5VDC Output USB /
TYPE C Charger
6. 120V AC Output NEMA
5-20R outlets
(Max 20A)
7. 120V AC Output NEMA
TT-30R receptacle
8. Touchscreen
9. Indicator Light
10. Air Vent (removable for
cleaning)
4.1 Top Panel
1. Wireless Charger
Note: The wireless
charger can be used
to charge compatible
electronic devices.
9
76
5
4
2
1
3
8
10

5
12V/24V
MAX
10A
·
DC INPUT
MAX
35A
·
AC INPUT
COM1
AC OUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4400W(18A)
SOLAR INPUT
ONLYCONNECT HYSOLIS 5K BATTERIES.
DO NOT USE 3RD-PARTYBATTERIES.
CONNECTING THE WRONG BATTERY
MAYDAMAGE THE UNIT AND/OR HARM
THE USER.
CAUTION!
SWITCH BATTERIES OFF
BEFORE CONNECTING OR
DISCONNECTING BATTERY
CABLES.
CAUTION!
VOLTAGEMAY BE PRESENT ON
PV INPUT WHEN INVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECT ALL INPUT AND
OUTPUT CABLES BEFORE
SWITCHING ON OR OFF.
BATTERYMAY ALWAYS BE
LEFT ON EXCEPT FOR
SHIPPING OR STORAGE.
NOTICE!
Fig. 4.3 • Unit back panel
4.3 Back Panel
11. 120V AC Input Port
LP-28 (MAX 30A)
12. Inverter Reset Switch
13. AC Output parallel
communication port
(For AC output parallel
set up)
14. Expansion Battery
Port 1
15. Expansion Battery
Port 2
16. AC Input Reset Switch
17. 12/24VDC Input Port
(Max. 10A)
18. Power Switch
(for Battery BMS)
19. Solar Input Port
(Voc. Range 120V DC ~
500V DC,
Max. Charging Power
4,400W,
Max. Total Input for
Charging+Inverter
5,000W/18A)
20. BMS Working Status
Indicator
21. Ground Port
22. BMS Reset Button
11
12
13
14
16
17
18
22
15
19
21
20

6
4.4 Homepage UI Touchscreen
120VAC
PV
12VDC
AC Load
DC Load
11/15/XXXX 15:15
2560 W 2560 W
2500 W
120 W 330 W
AC ON
DC OFF
100%
Home
Settings
Information
Alerts
a. Homepage Button: Press to return to the Homepage UI touchscreen
b. Setting Screens Button: Press to access the Settings screens
c. Information Screens Button: Press to access the Information screens
d. Alert Screen Button: Press to access the current Alert screen
e. PV (solar) Button: Press to access the PV Input information screen
f. AC Button: Press to access the AC Input information screen
g. Battery Button: Press to access the Battery information screen
h. Date & Time: Displays current Date and Time
i. AC Load Button: Press to access the AC Output information screen
j. AC Output On/OFF Switch: Toogle to turn AC Output ON or OFF
k. DC Load Button: Press to access the DC Output information screen
l. DC Output ON/OFF Switch: Toggle to turn DC Output ON or OFF
m. DC Button: Press to access the DC Charge information screen
Fig. 4.4 • Homepage UI touchscreen features
a
b
c
d
e h
m
j
g
k
l
f
i

7
120VAC
PV
Home
Settings
Data
Warnings
12VDC
AC Load
DC Load
11/15/XXXX 15:15
2560 W 2560 W
2500 W
120 W 330 W
AC ON
DC OFF
100%
ECO
Fig. 4.5 • Homepage UI touchscreen icons
h
ECO
e
c d
f
g
i
a. AC/DC Status: The unit is charging.
c. Bluetooth Indicator (connected): The unit is connected to Bluetooth.
d. Bluetooth Indicator (not connected): The unit is not connected
to Bluetooth.
e. WiFi Status (connected): The unit is connected to a WiFi network.
f. WiFi Status (ready to connect): The WiFi settings have been reset
and the device is ready to connect to a WiFi network.
g. WiFi Status (connecting): The unit is connecting to Bluetooth.
h. Energy Saver Mode Status: Energy saver mode is on.
i. Inverter Status (disconnected): The inverter is disconnected, click to
power on the inverter.
k. Inverter Status (disconnected): Inverter may not be used when
using AC F.C. mode greater than the default value.
j. Unattended Mode Status: Unattended mode is on.
b. Battery Status Indicator: Battery charge level.
4.5 Homescreen UI Icons
j
a
b
k

8
5.0 Installation
Important! A licensed electrician is required to install the Apollo 5K in any
hardwired fashion. An Apollo 5K Wiring Box (Optional Purchase) may be used in
the installation. For all configurations, please consider the rated amperages of
power sources, total loads, wires, and the Apollo 5K. Do not exceed limits.
The Apollo 5K factory default setting is “floating neutral” (i.e. the neutral and
ground are unbonded.
The unit should be configured with floating neutral when connecting the load
side of the Apollo to a separate ground (e.g. directly supplying power to a home
breaker panel).
The unit may be configured with a neutral-ground bond, a.k.a. “bonded
neutral”, which may be preferred for some o-grid applications. To bond the
neutral to the ground, please follow instructions according to the label on the
side panel of the Apollo as depicted in Fig. 5.1 and Fig. 5.2 below.
The Apollo ground port may be connected to a grounding rod, building rod, etc.
by a qualified electrician. Ensure the Apollo neutral-ground is appropriately
bonded or unbonded.
BATTERY 2
51.2VDC
BATTERY 2
51.2VDC
RESET RUN ALM CHARGE
AC OUTPUT COMM.P ORT
110V/120V
MAX 35A
AC INPUT
WARNING!
COM1 COM2
DO NOT CONNECT DIFFEREN T TYPE
OF BATTERY! WRONG BATTERY MAY
DAMAGE THE WHOLE UNIT. THE
EXPANSION BATTERY PACK MUST
BE SUPPLIED BY THE ORIGIN AL
MANUFACTURUR.
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
120V~450V DC
MAX 5000W
SOLAR INPUT
12V/24V
MAX 10A
DC INPUT
Fig. 5.1 Neutral-Ground Separated /
Floating Neutral (Factory Default): The
Neutral wires to the plastic pole
Fig. 5.2
Neutral-Ground Bonded: The Neutral
wires to the metal structure

9
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V 2.4A
QC 3.0
PD60W
12VDC
2A
AC OUTPUT
25AMAX
AC OUTPUT M AX 15A
INPUT OUTPUT
5.1 Overview
There are two installation options. These include Single Unit setup and
Multi-unit setup. The power sources for each option include:
• AC input (i.e. utility power or generator)
• DC input (i.e. automobile with DC output)
• PV input (i.e. solar photovoltaic panels)
• Both setups provide AC and DC output.
5.2 General Installation Guidelines
During transport, the unit may have warmed or cooled outside of its working
temperature range. Moisture may have condensed on the unit. Ensure it is dry
and within the proper temperature range before using.
• Do not use the product in a wet or dusty environment.
• Do not use anything flammable or explosive near the product.
• Do not cover or block the vents in the product.
• Maintain 4 inches (10cm) of clear space around the unit to have good heat
dissipation.
5.3 Single Unit Options
This section provides an overview of the single unit options. It shows input
power options (Fig. 5.3), possible ouput capabilties, and describes the input and
output power parameters for AC, DC, and PV (solar) input and AC, DC output.
Fig. 5.3 Power options and output capabilities
PV
Utility
AC
Loads
DC
Loads
Generator
Vehicle

10
12V/24V
MAX
10A
·
DC INPUT
MAX
35A
·
AC INPUT
COM1
AC OUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4400W(18A)
SOLAR INPUT
ONLYCONNECT HYSOLIS 5K BATTERIES.
DONOT USE 3RD-PARTY BATTERIES.
CONNECTINGTHE WRONG BATTERY
MAYDAMAGE THE UNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIES OFF
BEFORECONNECTING OR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAY BE PRESENT ON
PVINPUT WHEN INVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALL INPUT AND
OUTPUTCABLES BEFORE
SWITCHINGON OR OFF.
BATTERYMAYALWAYS BE
LEFTON EXCEPT FOR
SHIPPINGOR STORAGE.
NOTICE!
Acceptable
Voltage Range
65V~140VAC (for home appliances)
95V~140VAC (for computers)
Frequency 60Hz / 50Hz (auto-sensing)
Maximum
Current 30A (3,600 watts)
Table 5.1 Single unit - 120V AC input power parameters
5.3.1 Single Unit: 120V AC Input
INPUT PORT
Generator
Utility power
Fig. 5.4 Single unit - 120V AC input port and cable

11
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V 2.4A
QC 3.0
PD60W
12VDC
2A
AC OUTPUT
25AMAX
AC OUTPU T MAX 15A
5.3.2 Single Unit: 120V AC Output
OUTLET PORTS
Voltage Range 120VAC (+/-5%) 60Hz / 50Hz
(auto sensing)
Wave Form Pure sine wave
Rated Current 25A (3,000 watts) / Surge: 50A
(6,000 watts)
Table 5.2 120V AC output power parameters
Fig. 5.5 120V AC output ports

12
12V/24V
MAX
10A
·
DC INPUT
MAX
35A
·
ACINPUT
COM1
ACOUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4400W(18A)
SOLAR INPUT
ONLYCONNECT HYSOLIS 5K BATTERIES.
DONOT USE 3RD-PARTY BATTERIES.
CONNECTINGTHE WRONG BATTERY
MAYDAMAGE THE UNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIES OFF
BEFORECONNECTING OR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAYBE PRESENT ON
PVINPUT WHEN INVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALL INPUT AND
OUTPUTCABLES BEFORE
SWITCHINGON OR OFF.
BATTERYMAYALWAYS BE
LEFTON EXCEPT FOR
SHIPPINGOR STORAGE.
NOTICE!
Acceptable Voltage Range 12VDC or 24VDC
Maximum Current 10A
Table 5.3 120V DC input power parameters
INPUT PORT
Fig. 5.6 Single unit - 120V DC input port and cable
5.3.3 Single Unit: 120V DC Input

13
Wireless Charger Max 20W
12VDC Output Anderson Plug Max 30A
12VDC Output Cigarette Lighter Socket Max 10A
5VDC Output USB / TYPE C Charger Max 100W
12VDC Output 5210 Sockets Max 2A
5.3.4 Single Unit: 120V DC Output
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V 2.4A
QC 3.0
PD60W
12VDC
2A
AC OUTPUT
25AMAX
AC OUTPU T MAX 15A
OUTLET PORTS
Fig. 5.7
Fan 1X: 12VDC Output
Cigarette Lighter
Socket (MAX 10A)
Refrigerator 1x: 12VDC
Output Anderson
Plug (MAX 30A)
Phone 1x: 5VDC
Output USB / TYPE
C Charger
Light Bulb 1X:
12VDC Output 5210
Sockets (MAX 2A)
Table 5.4 120V DC output power parameters
Fig. 5.7 Single unit - 120V DC output ports

14
12V/24V
MAX
10A
·
DCINPUT
MAX
35A
·
ACINPUT
COM1
ACOUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4000W(18A)
SOLARINPUT
ONLYCONNECTHYSOLIS 5K BATTERIES.
DONOT USE 3RD-PARTY BATTERIES.
CONNECTINGTHE WRONG BATTERY
MAYDAMAGETHE UNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIES OFF
BEFORECONNECTING OR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAYBE PRESENT ON
PVINPUT WHEN INVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALL INPUT AND
OUTPUTCABLES BEFORE
SWITCHINGON OR OFF.
BATTERYMAYALWAYSBE
LEFTON EXCEPT FOR
SHIPPINGOR STORAGE.
NOTICE!
Panel 1 Panel 2 Panel 3 Panel N
5.3.5 Single Unit: PV (solar) Input
Fig. 5.8 Single unit - PV input port and cable (N panels)
Solar MPPT Voltage Range 120VDC~500VDC
Maximum Solar Charging Power 4,400 watts
Maximum Solar Input Current 18A
Maximum Solar Input Power 5,000 watts*
Maximum MPPT Charge Current DC 80A
Table 5.5 PV input power parameters
N panels in series
(Note: always configure
your array within the
MPPT specifications
(Table 5.5)
* When Inverter is Active, some Solar Input Power may be
used for Inverter Power

15
Table 5.6 Possible multi-unit configurations
Mode Phase Description
Single-phase
120V 60Hz
Single Unit 120V/60Hz, 25A
Multi (N) Units N≤12 120V/60Hz, 25A x N
(Stack Power & current)
Split-phase
240V 60Hz
P1 (Phase 1) x N Units N≤6 Line 1, 120V/60Hz, 25A x N
(Stack Power & current)
P2 (Phase 2) x N Units N≤6 Line 2, 120V/60Hz, 25A x N
(Stack Power & current)
3-phase
208V 60Hz
P1 (Phase 1) x N Units N≤4 Line 1, 120V/60Hz, 25A x N
(Stack Power & current)
P2 (Phase 2) x N Units N≤4 Line 2, 120V/60Hz, 25A x N
(Stack Power & current)
P3 (Phase 3) x N Units N≤4 Line 3, 120V/60Hz, 25A x N
(Stack Power & current)
Note: N = Number of Apollo 5K units
5.4 Multi-unit Setup
This section provides wiring diagrams for a multi-unit setup. The Apollo 5K
supports up to 12 units (36KW) working synergically for single-phase,
split-phase or 3-phase power supply.
Important! Additional accessories are needed for setting up the Apollo 5K
multi-unit system. They may be supplied by a qualified electrician. Hysolis
split-phase and single-phase parallel accessories are available for purchase.
Possible configurations include (Table 5.6):
• Up to 12 units can be stacked in parallel for Single-phase
• Up to 6 units for each of the Lines 1 and 2 for Split-Phase
• Up to 4 units each for the lines 1, 2, and 3 for 3-phase.
Note: Each Apollo has a maximum output of 25A. Each line has a maximum
current of 25A x N. Up to 12 units can be configured into Single-phase,
Split-phase, or 3-phase AC Output.

16
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V2.4A
QC3.0
PD60W
12VDC
2A
ACO UTPUT
25AMAX
ACO UTPUT MAX 15A
12V/24V
MAX
10A
·
DCINPUT
MAX
35A
·
ACINPUT
COM1
ACOUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4000W(18A)
SOLARINPUT
ONLYCONNECTHYSOLIS5K BATTERIES.
DONOTUSE 3RD-PARTYBATTERIES.
CONNECTINGTHEWRONG BATTERY
MAYDAMAGETHEUNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIESOFF
BEFORECONNECTINGOR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAYBEPRESENT ON
PVINPUTWHEN INVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALLINPUTAND
OUTPUTCABLESBEFORE
SWITCHINGONOR OFF.
BATTERYMAYALWAYSBE
LEFTONEXCEPT FOR
SHIPPINGORSTORAGE.
NOTICE!
12V/24V
MAX
10A
·
DCINPUT
MAX
35A
·
ACINPUT
COM1
ACOUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4000W(18A)
SOLARINPUT
ONLYCONNECTHYSOLIS5K BATTERIES.
DONOTUSE 3RD-PARTYBATTERIES.
CONNECTINGTHEWRONG BATTERY
MAYDAMAGETHEUNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIESOFF
BEFORECONNECTINGOR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAYBEPRESENT ON
PVINPUTWHEN INVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALLINPUTAND
OUTPUTCABLESBEFORE
SWITCHINGONOR OFF.
BATTERYMAYALWAYSBE
LEFTONEXCEPT FOR
SHIPPINGORSTORAGE.
NOTICE!
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V2.4A
QC3.0
PD60W
12VDC
2A
ACO UTPUT
25AMAX
ACO UTPUT MAX 15A
AC
Input
N
L
AC
Output
Unit 1 Unit 2
N
L
Communication
Wires
12V/24V
MAX
10A
·
DCINPUT
MAX
35A
·
ACINPUT
COM1
ACOUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4000W(18A)
SOLARINPUT
ONLYCONNECTHYSOLIS5K BATTERIES.
DONOTUSE 3RD-PARTYBATTERIES.
CONNECTINGTHEWRONG BATTERY
MAYDAMAGETHEUNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIESOFF
BEFORECONNECTINGOR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAYBEPRESENT ON
PVINPUTWHEN INVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALLINPUTAND
OUTPUTCABLESBEFORE
SWITCHINGONOR OFF.
BATTERYMAYALWAYSBE
LEFTONEXCEPT FOR
SHIPPINGORSTORAGE.
NOTICE!
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V2.4A
QC3.0
PD60W
12VDC
2A
ACO UTPUT
25AMAX
ACO UTPUT MAX 15A
12V/24V
MAX
10A
·
DCINPUT
MAX
35A
·
ACINPUT
COM1
ACOUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4000W(18A)
SOLARINPUT
ONLYCONNECTHYSOLIS5K BATTERIES.
DONOTUSE 3RD-PARTYBATTERIES.
CONNECTINGTHEWRONG BATTERY
MAYDAMAGETHEUNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIESOFF
BEFORECONNECTINGOR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAYBEPRESENT ON
PVINPUTWHEN INVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALLINPUTAND
OUTPUTCABLESBEFORE
SWITCHINGONOR OFF.
BATTERYMAYALWAYSBE
LEFTONEXCEPT FOR
SHIPPINGORSTORAGE.
NOTICE!
12V/24V
MAX
10A
·
DCINPUT
MAX
35A
·
ACINPUT
COM1
ACOUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4000W(18A)
SOLARINPUT
ONLYCONNECTHYSOLIS5K BATTERIES.
DONOTUSE 3RD-PARTYBATTERIES.
CONNECTINGTHEWRONG BATTERY
MAYDAMAGETHEUNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIESOFF
BEFORECONNECTINGOR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAYBEPRESENT ON
PVINPUTWHEN INVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALLINPUTAND
OUTPUTCABLESBEFORE
SWITCHINGONOR OFF.
BATTERYMAYALWAYSBE
LEFTONEXCEPT FOR
SHIPPINGORSTORAGE.
NOTICE!
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V2.4A
QC3.0
PD60W
12VDC
2A
ACO UTPUT
25AMAX
ACO UTPUT MAX 15A
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V2.4A
QC3.0
PD60W
12VDC
2A
ACO UTPUT
25AMAX
ACO UTPUT MAX 15A
AC
Input
N
L
AC
Output
Unit 1 Unit 3Unit 2
N
L
Communication
Wires
Single-phase • 3 Units
5.4.1 Single-phase System (120VAC) Wiring Diagrams
Single-phase • 2 Units
Fig. 5.10 Multi-unit single-phase wiring, 2 units
Fig. 5.11 Multi-unit single-phase wiring, 3 units

17
Single-phase • 5 Units
12V/24V
MAX
10A
·
DCINPUT
MAX
35A
·
ACINPUT
COM1
ACOUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4000W(18A)
SOLARINPUT
ONLYCONNECTHYSOLIS5K BATTERIES.
DONOTUSE 3RD-PARTYBATTERIES.
CONNECTINGTHEWRONG BATTERY
MAYDAMAGETHEUNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIESOFF
BEFORECONNECTINGOR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAYBEPRESENT ON
PVINPUTWHEN INVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALLINPUTAND
OUTPUTCABLESBEFORE
SWITCHINGONOR OFF.
BATTERYMAYALWAYSBE
LEFTONEXCEPT FOR
SHIPPINGORSTORAGE.
NOTICE!
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V2.4A
QC3.0
PD60W
12VDC
2A
ACO UTPUT
25AMAX
ACO UTPUT MAX 15A
12V/24V
MAX
10A
·
DCINPUT
MAX
35A
·
ACINPUT
COM1
ACOUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4000W(18A)
SOLARINPUT
ONLYCONNECTHYSOLIS5K BATTERIES.
DONOTUSE 3RD-PARTYBATTERIES.
CONNECTINGTHEWRONG BATTERY
MAYDAMAGETHEUNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIESOFF
BEFORECONNECTINGOR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAYBEPRESENT ON
PVINPUTWHEN INVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALLINPUTAND
OUTPUTCABLESBEFORE
SWITCHINGONOR OFF.
BATTERYMAYALWAYSBE
LEFTONEXCEPT FOR
SHIPPINGORSTORAGE.
NOTICE!
12V/24V
MAX
10A
·
DCINPUT
MAX
35A
·
ACINPUT
COM1
ACOUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4000W(18A)
SOLARINPUT
ONLYCONNECTHYSOLIS5K BATTERIES.
DONOTUSE 3RD-PARTYBATTERIES.
CONNECTINGTHEWRONG BATTERY
MAYDAMAGETHEUNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIESOFF
BEFORECONNECTINGOR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAYBEPRESENT ON
PVINPUTWHEN INVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALLINPUTAND
OUTPUTCABLESBEFORE
SWITCHINGONOR OFF.
BATTERYMAYALWAYSBE
LEFTONEXCEPT FOR
SHIPPINGORSTORAGE.
NOTICE!
12V/24V
MAX
10A
·
DCINPUT
MAX
35A
·
ACINPUT
COM1
ACOUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4000W(18A)
SOLARINPUT
ONLYCONNECTHYSOLIS5K BATTERIES.
DONOTUSE 3RD-PARTYBATTERIES.
CONNECTINGTHEWRONG BATTERY
MAYDAMAGETHEUNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIESOFF
BEFORECONNECTINGOR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAYBEPRESENT ON
PVINPUTWHEN INVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALLINPUTAND
OUTPUTCABLESBEFORE
SWITCHINGONOR OFF.
BATTERYMAYALWAYSBE
LEFTONEXCEPT FOR
SHIPPINGORSTORAGE.
NOTICE!
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V2.4A
QC3.0
PD60W
12VDC
2A
ACO UTPUT
25AMAX
ACO UTPUT MAX 15A
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V2.4A
QC3.0
PD60W
12VDC
2A
ACO UTPUT
25AMAX
ACO UTPUT MAX 15A
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V2.4A
QC3.0
PD60W
12VDC
2A
ACO UTPUT
25AMAX
ACO UTPUT MAX 15A
AC
Input
N
L
AC
Output
Unit 1 Unit 3 Unit 4
Unit 2
N
L
Communication
Wires
12V/24V
MAX
10A
·
DCINPUT
MAX
35A
·
ACINPUT
COM1
ACOUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4000W(18A)
SOLARINPUT
ONLYCONNECTHYSOLIS5K BATTERIES.
DONOTUSE 3RD-PARTYBATTERIES.
CONNECTINGTHEWRONG BATTERY
MAYDAMAGETHEUNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIESOFF
BEFORECONNECTINGOR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAYBEPRESENT ON
PVINPUTWHEN INVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALLINPUTAND
OUTPUTCABLESBEFORE
SWITCHINGONOR OFF.
BATTERYMAYALWAYSBE
LEFTONEXCEPT FOR
SHIPPINGORSTORAGE.
NOTICE!
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V2.4A
QC3.0
PD60W
12VDC
2A
ACO UTPUT
25AMAX
ACO UTPUT MAX 15A
12V/24V
MAX
10A
·
DCINPUT
MAX
35A
·
ACINPUT
COM1
ACOUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4000W(18A)
SOLARINPUT
ONLYCONNECTHYSOLIS5K BATTERIES.
DONOTUSE 3RD-PARTYBATTERIES.
CONNECTINGTHEWRONG BATTERY
MAYDAMAGETHEUNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIESOFF
BEFORECONNECTINGOR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAYBEPRESENT ON
PVINPUTWHEN INVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALLINPUTAND
OUTPUTCABLESBEFORE
SWITCHINGONOR OFF.
BATTERYMAYALWAYSBE
LEFTONEXCEPT FOR
SHIPPINGORSTORAGE.
NOTICE!
12V/24V
MAX
10A
·
DCINPUT
MAX
35A
·
ACINPUT
COM1
ACOUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4000W(18A)
SOLARINPUT
ONLYCONNECTHYSOLIS5K BATTERIES.
DONOTUSE 3RD-PARTYBATTERIES.
CONNECTINGTHEWRONG BATTERY
MAYDAMAGETHEUNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIESOFF
BEFORECONNECTINGOR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAYBEPRESENT ON
PVINPUTWHEN INVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALLINPUTAND
OUTPUTCABLESBEFORE
SWITCHINGONOR OFF.
BATTERYMAYALWAYSBE
LEFTONEXCEPT FOR
SHIPPINGORSTORAGE.
NOTICE!
12V/24V
MAX
10A
·
DCINPUT
MAX
35A
·
ACINPUT
COM1
ACOUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4000W(18A)
SOLARINPUT
ONLYCONNECTHYSOLIS5K BATTERIES.
DONOTUSE 3RD-PARTYBATTERIES.
CONNECTINGTHEWRONG BATTERY
MAYDAMAGETHEUNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIESOFF
BEFORECONNECTINGOR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAYBEPRESENT ON
PVINPUTWHEN INVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALLINPUTAND
OUTPUTCABLESBEFORE
SWITCHINGONOR OFF.
BATTERYMAYALWAYSBE
LEFTONEXCEPT FOR
SHIPPINGORSTORAGE.
NOTICE!
12V/24V
MAX
10A
·
DCINPUT
MAX
35A
·
ACINPUT
COM1
ACOUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4000W(18A)
SOLARINPUT
ONLYCONNECTHYSOLIS5K BATTERIES.
DONOTUSE 3RD-PARTYBATTERIES.
CONNECTINGTHEWRONG BATTERY
MAYDAMAGETHEUNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIESOFF
BEFORECONNECTINGOR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAYBEPRESENT ON
PVINPUTWHEN INVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALLINPUTAND
OUTPUTCABLESBEFORE
SWITCHINGONOR OFF.
BATTERYMAYALWAYSBE
LEFTONEXCEPT FOR
SHIPPINGORSTORAGE.
NOTICE!
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V2.4A
QC3.0
PD60W
12VDC
2A
ACO UTPUT
25AMAX
ACO UTPUT MAX 15A
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V2.4A
QC3.0
PD60W
12VDC
2A
ACO UTPUT
25AMAX
ACO UTPUT MAX 15A
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V2.4A
QC3.0
PD60W
12VDC
2A
ACO UTPUT
25AMAX
ACO UTPUT MAX 15A
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V2.4A
QC3.0
PD60W
12VDC
2A
ACO UTPUT
25AMAX
ACO UTPUT MAX 15A
AC
Input
N
L
AC
Output
Unit 1 Unit 3 Unit 4
Unit 2
N
L
Unit 5
Communication
Wires
Single-phase • 4 Units
Fig. 5.12 Multi-unit single-phase wiring, 4 units
Fig. 5.13 Multi-unit single-phase wiring, 5 units

18
12V/24V
MAX
10A
·
DCINPUT
MAX
35A
·
ACINPUT
COM1
ACOUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4000W(18A)
SOLARINPUT
ONLYCONNECTHYSOLIS5K BATTERIES.
DONOTUSE3RD-PARTY BATTERIES.
CONNECTINGTHEWRONGBATTERY
MAYDAMAGETHEUNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIESOFF
BEFORECONNECTINGOR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAYBEPRESENTON
PVINPUTWHENINVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALLINPUTAND
OUTPUTCABLESBEFORE
SWITCHINGONOROFF.
BATTERYMAYALWAYSBE
LEFTONEXCEPTFOR
SHIPPINGORSTORAGE.
NOTICE!
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V2.4A
QC3.0
PD60W
12VDC
2A
ACOUTPUT
25AMAX
ACOUTPUT MAX 15A
12V/24V
MAX
10A
·
DCINPUT
MAX
35A
·
ACINPUT
COM1
ACOUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4000W(18A)
SOLARINPUT
ONLYCONNECTHYSOLIS5K BATTERIES.
DONOTUSE3RD-PARTY BATTERIES.
CONNECTINGTHEWRONGBATTERY
MAYDAMAGETHEUNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIESOFF
BEFORECONNECTINGOR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAYBEPRESENTON
PVINPUTWHENINVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALLINPUTAND
OUTPUTCABLESBEFORE
SWITCHINGONOROFF.
BATTERYMAYALWAYSBE
LEFTONEXCEPTFOR
SHIPPINGORSTORAGE.
NOTICE!
12V/24V
MAX
10A
·
DCINPUT
MAX
35A
·
ACINPUT
COM1
ACOUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4000W(18A)
SOLARINPUT
ONLYCONNECTHYSOLIS5K BATTERIES.
DONOTUSE3RD-PARTY BATTERIES.
CONNECTINGTHEWRONGBATTERY
MAYDAMAGETHEUNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIESOFF
BEFORECONNECTINGOR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAYBEPRESENTON
PVINPUTWHENINVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALLINPUTAND
OUTPUTCABLESBEFORE
SWITCHINGONOROFF.
BATTERYMAYALWAYSBE
LEFTONEXCEPTFOR
SHIPPINGORSTORAGE.
NOTICE!
12V/24V
MAX
10A
·
DCINPUT
MAX
35A
·
ACINPUT
COM1
ACOUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4000W(18A)
SOLARINPUT
ONLYCONNECTHYSOLIS5K BATTERIES.
DONOTUSE3RD-PARTY BATTERIES.
CONNECTINGTHEWRONGBATTERY
MAYDAMAGETHEUNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIESOFF
BEFORECONNECTINGOR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAYBEPRESENTON
PVINPUTWHENINVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALLINPUTAND
OUTPUTCABLESBEFORE
SWITCHINGONOROFF.
BATTERYMAYALWAYSBE
LEFTONEXCEPTFOR
SHIPPINGORSTORAGE.
NOTICE!
12V/24V
MAX
10A
·
DCINPUT
MAX
35A
·
ACINPUT
COM1
ACOUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4000W(18A)
SOLARINPUT
ONLYCONNECTHYSOLIS5K BATTERIES.
DONOTUSE3RD-PARTY BATTERIES.
CONNECTINGTHEWRONGBATTERY
MAYDAMAGETHEUNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIESOFF
BEFORECONNECTINGOR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAYBEPRESENTON
PVINPUTWHENINVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALLINPUTAND
OUTPUTCABLESBEFORE
SWITCHINGONOROFF.
BATTERYMAYALWAYSBE
LEFTONEXCEPTFOR
SHIPPINGORSTORAGE.
NOTICE!
12V/24V
MAX
10A
·
DCINPUT
MAX
35A
·
ACINPUT
COM1
ACOUTPUT
COMM.PORT
COM2
RESET
RUN
ALM
CHARGE
I
n
v
e
r
t
e
r
R
e
s
e
t
S
w
i
t
c
h
A
C
I
n
p
u
t
R
e
s
e
t
S
w
i
t
c
h
BATTERY
1
51.2VDC
BATTERY
2
51.2VDC
120V~450V
MAX.4000W(18A)
SOLARINPUT
ONLYCONNECTHYSOLIS5K BATTERIES.
DONOTUSE3RD-PARTY BATTERIES.
CONNECTINGTHEWRONGBATTERY
MAYDAMAGETHEUNIT AND/OR HARM
THEUSER.
CAUTION!
SWITCHBATTERIESOFF
BEFORECONNECTINGOR
DISCONNECTINGBATTERY
CABLES.
CAUTION!
VOLTAGEMAYBEPRESENTON
PVINPUTWHENINVERTER IS
OPERATING..
DANGER!
Battery
Switch
DISCONNECTALLINPUTAND
OUTPUTCABLESBEFORE
SWITCHINGONOROFF.
BATTERYMAYALWAYSBE
LEFTONEXCEPTFOR
SHIPPINGORSTORAGE.
NOTICE!
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V2.4A
QC3.0
PD60W
12VDC
2A
ACOUTPUT
25AMAX
ACOUTPUT MAX 15A
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V2.4A
QC3.0
PD60W
12VDC
2A
ACOUTPUT
25AMAX
ACOUT PUT MAX 15A
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V2.4A
QC3.0
PD60W
12VDC
2A
ACOUTPUT
25AMAX
ACOUTPUT MAX 15A
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V2.4A
QC3.0
PD60W
12VDC
2A
ACOUTPUT
25AMAX
ACOUT PUT MAX 15A
1
2
V
D
C
M
A
X
3
0
A
12VDC
MAX 30A
PD60W
5V2.4A
QC3.0
PD60W
12VDC
2A
ACOUTPUT
25AMAX
ACOUTPUT MAX 15A
AC
Output
Unit 1 Unit 3 Unit N2Unit 2
N
L
Unit N1 Unit N
AC
Input
N
L
Communication Wires
Single-phase • 6+ Units (N≤12) (Note: N = number of Apollo 5K units)
Fig. 5.14 Multi-unit single-phase wiring, 6+ units (N≤12)
Other manuals for Apollo 5K
1
Table of contents
Other Hysolis Power Supply manuals
Popular Power Supply manuals by other brands

Pulsar
Pulsar HPSB 10A24D manual

Conrad Electronic
Conrad Electronic FSP550-60PLN operating instructions

TDK-Lambda
TDK-Lambda JWT Series instruction manual

Dometic
Dometic SMP301-11 Installation and operating manual

Allied Telesis
Allied Telesis CONVERTEON AT-PWR15 installation guide

Deif
Deif DPS-1 Installation and operation instructions