USER MANUAL
Bacteria UV
sterilizer UVC-1
1.1
Device description
1.1.1.
The Device is a household appliance used for air disinfection in
living areas, offices and industrial premises. In general, the Device is intended
for use in procedures aimed to decrease the number of pathogens contained
in the air in order to prevent diseases. Operating principle is based on
pumping room air through a closed housing of the Device and exposing it to
ultraviolet (hereinafter referred to as UV)
. Emission of the built-in UV lamp has
a maximum wavelength of 253.7 nm and destroys all types of harmful
microorganisms: bacteria, viruses, molds, fungi, etc.
1.1.2.
This is an enclosed-type device which operates completely safely
with people present
.
1.3. Devicecomponents and supplied package
Devicecomponents andsupplied package
are specified in the
Table 2.
Table 1
Table 2
This User Manual includes key features, operating
instructions, intended use, maintenance, repair, storage and
transportation of Bacteria UV sterilizer UVC-1 (hereinafter
referred to as the Device).
Attention!
Please carefully read the present User Manual
before using
the Device.
Follow the rules, restrictions and instructions contained in this
User Manual in order to increase the lifespan of the Device and to
use it more effectively
.
Violation of the storage instructions and operating rules will
lead to manufacturer warranty termination.
Attention!
After transportation during winter period or long storing keep the Device at
room temperature for two hours before using it.
1.2
Technical features
1.2.1.
Visual appearance of the Device is shown in the Picture 1.
1.2.2
.Technical features are presented in the Table 1.
1.4.
Structure and functioning
1.4.1.
The Device is constructed of a metal housing with polymer or powder
coating with a built-in UV lamp, start-control devices and a fan for forced air
circulation.
There are mounting holes for wall mounting (horizontal or vertical) located on
the lower side of the housing.
The Device is equipped with a power cord and a power switch on it.
1.4.2.
Disinfection is conducted by circulating room air through the closed
housing of the Device and exposing it to ultraviolet. Forced air circulation is
provided by the fan
.
1.4.3. TheUV lampneeds tobereplaced after11000 hours of operation.
2 INTENDED USE
2.1 Operating restrictions
2.1.1.Do not drop the Device.
Description
Quantity
Notice
1
Bacteria UV sterilizer UVC-1
1
2
UV lamp
1
Installed in the Sterilizer
3
Individual packaging
1
4
User Manual
1
Pic. 1
1 DEVICE DESCRIPTION AND OPERATION
Parameter
Value
Dimensions
450х78х72
mm
(17.9x3.1x2.9
in)
Weight
2.2 kg (4.85 lb)
Supply voltage (50 Hz)
230±23 V
Power consumption
15 W
Number of UV lamps
1
Power of UV lamp
8 W
Type of UV lamp
TUV8wPhilips
Endurance of UV lamp
11000 hours
IP Code
IP20
2.1.2. Ultraviolet is harmful for eyes! It is strictly prohibited to peep into holes
of the housing when the Device is operating. Also, it is prohibited to switch on
the Device with the housing lid removed.
2.2
Setting-up procedures
2.2.1.
Before operating the Device, you need to:
–
Install the Device on an even horizontal surface (a table, a bedstand) or
mount it horizontally on a wall at a height of 2.0-2.1 m (6.5-6.9 ft) above the
floor. Either mount it vertically with the lower side at a height of 1.6 m (5.2 ft)
above the floor (not less).
–
Plug in the power cord.
2.2.2.
The Device can be switched on and off by a switch located on the
power cord.
3.1.
Make sure the Device is unplugged before performing any
maintenance.
3.2.
Prevent the UV lamp from damaging while maintaining the Device
.
3.3.
Maintenance requires cleaning the housing and the lamp
from dust as well as replacing the lamp once it’s dead.
3.4.
Unscrew the screws on the housing to remove the lid as shown in the
Picture 2 in order to clean or replace the lamp
.
Pic. 2
3.5.
Use a sponge soaked in distilled water (make sure it is wrung-out)
for cleaning the lamp. The lamp must be clean as even a film of dust on
the lamp affects bactericidal property of the Device.
3.6.
4
TROUBLESHOOTING
Typical problems and possible solutions are specified in the Table 3.
Table 3
Problem
Possible
reason
Possible
solution
UV lamp doesn’t work
Need to replace UV
lamp
Replace UV lamp
The Device is defective
Take the Device to a
service center
The fan doesn’t work
The Device is defective
Take the Device to a
service center
Each device is packed in an individual package according to the supply
package as indicated in Table 2. Device moving in the package is not allowed.
Packaged devices can be transported by vehicle or railway in covered
trucks or containers, by air in pressurized compartments
.
During transportation packed packages should be protected from
precipitation and direct sun rays
.
Transportation conditions:
- Surrounding air temperature: from -50 up to 50° C (-58 to 122° F);
- Relative humidity up to 95 % at 25°C (77°F);
- Atmospheric pressure from 84 up to 107 kPa (630 - 800 mmHg);
- Shock acceleration peak value is up to 147 m/s2 (15 g), with a duration of shock
acceleration 10 ... 15 ms.
The requirements on warning signs must be strictly obeyed when loading and
transporting.
6 MANUFACTURERWARRANTY
6.1
Service life of the Device is 5 years.
6.2
Manufacturer warranty period is 12 months from the date
of purchase
.
6.3
If the Device fails during the warranty period,
the supplier (manufacturer or companies providing
maintenance services) should replace or repair it at its own
expense
.
6.4
Warranty is voided in the following cases
:
- After warranty period expiration;
- Violation of the operation, transportation and storage instructions;
- Mechanical damages causing failure of the Device after the purchase;
- Manufacturer sealing is broken.
6.5
Repair and maintenance of the devices with an expired warranty period
is covered at the customer’s expense
.
Manufacturer has the right to amend and change characteristics
of the Device in order to improve its consumer properties
.
Manufacturer's technical
support
:
www.en.i4technology.ru
3.6. In order to replace the lamp:
–
rotate the lamp around the longitudinal axis by 90 degrees, so that
the electrode terminals (screw caps) are opposite to the groove in
the lamp holder
©Авторское право
© Copyright "i4 Technology" LLC,
2021. All rights reserved.
" I4 Technology"LLC
www.en.i4Technology.ru
–remove the screw caps from the lamp holders;
–
install a new lamp and rotate it by 90 degrees.
Manufacturer's technical support: www.en.i4technology.ru
Questions concerning the exchange after-sales service should be applied
to the distributor that completed
5 PACKAGING AND TRANSPORTATION
3 MAINTENANCE

Popular Laboratory Equipment manuals by other brands

3D Histech Pannoramic DESK user guide

3D Histech

3D Histech Pannoramic DESK user guide

PerkinElmer IVIS Lumina XRMS III Series Hardware manual

PerkinElmer

PerkinElmer IVIS Lumina XRMS III Series Hardware manual

Isotech Saturn 877 User maintenance manual/handbook

Isotech

Isotech Saturn 877 User maintenance manual/handbook

PerkinElmer Spectrum RX I Getting started guide

PerkinElmer

PerkinElmer Spectrum RX I Getting started guide

Bio-Tek MultiFlo FX Operator's manual

Bio-Tek

Bio-Tek MultiFlo FX Operator's manual

PerkinElmer VICTOR Nivo user manual

PerkinElmer

PerkinElmer VICTOR Nivo user manual

Cooper Surgical K-Systems R65 user manual

Cooper Surgical

Cooper Surgical K-Systems R65 user manual

PerkinElmer Clarus 600/560 D MS Hardware guide

PerkinElmer

PerkinElmer Clarus 600/560 D MS Hardware guide

Bio-Science Ampulmatic-10 Purge Gas Injector Operation and maintenance manual

Bio-Science

Bio-Science Ampulmatic-10 Purge Gas Injector Operation and maintenance manual

RBCBioscience MagCore Plus II Service manual

RBCBioscience

RBCBioscience MagCore Plus II Service manual

PerkinElmer PINAACLE 900 Series Customer Hardware and Service Guide

PerkinElmer

PerkinElmer PINAACLE 900 Series Customer Hardware and Service Guide

Thermo Forma 3940 Operating and maintenance manual

Thermo Forma

Thermo Forma 3940 Operating and maintenance manual

PerkinElmer Lambda 365 user guide

PerkinElmer

PerkinElmer Lambda 365 user guide

Agilent Technologies 1100 Series Reference manual

Agilent Technologies

Agilent Technologies 1100 Series Reference manual

Labnet ProBlot Rocker 25 instruction manual

Labnet

Labnet ProBlot Rocker 25 instruction manual

Christ Epsilon 2-10D LSCplus operating manual

Christ

Christ Epsilon 2-10D LSCplus operating manual

Beckman Coulter UniCel DxC 600 Daily start up

Beckman Coulter

Beckman Coulter UniCel DxC 600 Daily start up

Memmert ICH eco Series operating instructions

Memmert

Memmert ICH eco Series operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.