iBall Nirantar UPS 1080V User manual

6 hours
CAUTION: NEVER connect a laser printer or scanner to the UPS
unit. This may cause the damage of the unit.
Nirantar UPS 1080V
User Manual
INTRODUCTION
Thank you for purchasing iBall Nirantar UPS 1080V. This UPS is specially aimed for
use with multi function personal computer. It is equipped with boost & buck AVR to
stabilize the wide input voltage range. It also comes with high-efficient switch-mode
battery charger. This charger design minimizes power loss to save charging time.
The built-in DC start function enables the UPS to be started up without a supply of
AC power. The main features of this UPS are listed below:
1 KVALine-Interactive design
33% faster recharging
Double battery for extended backup
Microprocessor control guarantees high reliability
Built-in enhanced boost & buckAVR
Green power function for energy saving
Auto restart during AC recovery
SYSTEM DESCRIPTION
INSTALLATION & OPERATION
1. Inspection
You should receive the following items inside the package:
- iBall Nirantar UPS 1080V
- User Manual
Remove the UPS from its packaging and inspect it for damage that may have
occurred during shipping. If any damage is discovered, repack the unit and return it
to the place of purchase.
2. Placement
Install the UPS in a protected area that is free of excessive dust and has adequate
air flow. Please place the UPS away from other units at least 20 cm to avoid
interference. Do NOT operate the UPS where the temperature and humidity is
outside the specific limits. (Please check the specs for the limitations.)
3. Charging
Plug in the AC input cord to the wall outlet. For the best
results, suggest to charge the battery at least 6 hours
before initial use. The unit charges its battery while
connecting to the utility.
4. Computer Connection
Plug in the loads to output receptacles on the rear panel of the UPS. Simply turn on
the power switch of UPS unit, then devices connected to the UPS will be protected
by UPS unit.
5. Turn On/Off
To turn on the UPS, press power switch lightly. To turn off the UPS, please press
power switch again.
6. DC Start Function
DC Start Function enables UPS to be started up when AC utility power is not
available and battery is charged. Just simply press the power switch to turn on the
UPS.
7. Green Power Function
This UPS is equipped with Green Power Function. For saving power and protecting
battery, the method of deep discharging protection is adopted on inverter mode.
Battery mode LED
AC input
Circuit breaker
Output
receptacles
AC mode LED
Fault LED
Power switch
TROUBLE SHOOTING
Use the table below to solve minor problems.
Problem
Possible Cause
Remedy
No LED display on the front
panel.
1. Battery weak
1. Re-charge battery up to 8 hours.
2. Battery defect.
2. Replace with the same type of battery.
3. Power switch is not pressed.
3. Press the power switch again.
Alarm buzzer beeps
continuously when AC
supply is normal.
Overload of the UPS.
Verify that the load matches the UPS
capability specified in the specs.
When power failure,
backup time is shorten.
1. Overload of the UPS.
1. Remove some non-critical load.
2. Battery voltage is too low.
2. Charge battery 4-6 hours or more.
3. Battery defect due to high
temperature operation
environment, or improper
operation to battery.
3. Replace with the same type of battery.
Mains normal but orange
LED is on.
1. Fuse is blown.
1. Replace the same type of fuse.
2. Power cord is loose.
2. Reconnect the power cord properly.
3. Battery defect.
3. Replace the same type of battery.
If any abnormal situations occur that are not listed above, please call service people immediately.
IMPORTANT SAFETY INSTRUCTION
To safely operate this uninterruptible power supply system, please read and follow all
instructions carefully. Please read this manual thoroughly before attempting to unpack, install,
or operate UPS, and keep this manual for further reference.
This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the
unit. The unit contains no user replaceable parts. Only authorized service personnel
may perform repairs.
Each Internal battery voltage is 12V DC. Sealed, lead-acid, 6 cells battery.
Connection to any other type of receptacle other than a two-pole, three-wire grounded
receptacle may result in shock hazard as well as violate local electrical codes.
In the event of an emergency, press the “OFF”button and disconnect the power cord
from the AC power supply to properly disable the UPS.
DO NOT allow liquids or any foreign object to enter the UPS. Do not place beverages
or any other liquid-containing vessels on or near the unit.
This unit intended for installation in a controlled environment (temperature controlled,
indoor area free of conductive contaminants). Avoid installing the UPS in location
where there is standing or running water, or excessive humidity.
DO NOT plug the UPS input into its own output.
DO NOT attach a power strip or surge suppressor to the UPS.
DO NOT attach non-computer-related items, such as medical equipment, life-support
equipment, microwave ovens, or vacuum cleaners to UPS
To reduce the risk of overheating the UPS, do not cover the UPS cooling vents and
avoid exposing the unit to direct sunlight or installing the unit near heat emitting
appliances such as space heaters or furnaces.
Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
DO NOT dispose of batteries in a fire as they may explode.
DO NOT open or destroy the battery or batteries. Released electrolyte is harmful to
the skin and eyes. It may be toxic.
Servicing of batteries should be performed or supervised by personnel
knowledgeable of batteries and the required precautions should be taken. Keep
unauthorized personnel away from batteries.
When replacing batteries, replace with the same number of the sealed lead-acid
batteries.
The batteries already installed by the supplier are operator installable and may be
operated by laymen.
The main socket outlet that supplies the UPS shall be installed near the UPS and shall
be easily accessible.
For any technical help on iBall products, please contact [email protected]
* Product specifications are subject to change without notice.** Battery backup may vary
depending on the configuration of computer system & other devices used. * All trademarks,
logos, brands & products names are properties of their respective owners. * Warranty: All
iBall products are governed by iBall warranty terms. Refer www.iBall.co.in

Other iBall UPS manuals

iBall NIRANTAR 1006B User manual

iBall

iBall NIRANTAR 1006B User manual

iBall Nirantar UPS-621V User manual

iBall

iBall Nirantar UPS-621V User manual

Popular UPS manuals by other brands

Vertiv Liebert ITA2 user manual

Vertiv

Vertiv Liebert ITA2 user manual

CyberPower SMP1400EILCD user manual

CyberPower

CyberPower SMP1400EILCD user manual

Tescom DS300 Series user manual

Tescom

Tescom DS300 Series user manual

Omron S8BA-24D24D120LF user manual

Omron

Omron S8BA-24D24D120LF user manual

Vertiv GXT4-5000RT230 Installer/user guide

Vertiv

Vertiv GXT4-5000RT230 Installer/user guide

Innovative Technology SR750i user manual

Innovative Technology

Innovative Technology SR750i user manual

Sven Pro+ 400 Operation manual

Sven

Sven Pro+ 400 Operation manual

Lowell UPS8-2000 User & installation manual

Lowell

Lowell UPS8-2000 User & installation manual

HPE G2 R5000 user guide

HPE

HPE G2 R5000 user guide

CyberPower 649532004256 Specification sheet

CyberPower

CyberPower 649532004256 Specification sheet

PROLiNK PWR7000 Series Specifications

PROLiNK

PROLiNK PWR7000 Series Specifications

AVIEM Systems PRO 1000VA user manual

AVIEM Systems

AVIEM Systems PRO 1000VA user manual

Powerware 5119 user guide

Powerware

Powerware 5119 user guide

PROLiNK MASTER II Series user guide

PROLiNK

PROLiNK MASTER II Series user guide

Chloride Power Protection Active 700 operating instructions

Chloride

Chloride Power Protection Active 700 operating instructions

Huawei UPS5000-A-500 kVA user manual

Huawei

Huawei UPS5000-A-500 kVA user manual

Vertiv Liebert GXT RT+ Quick installation guide

Vertiv

Vertiv Liebert GXT RT+ Quick installation guide

Power Inspired VIS0750 instructions

Power Inspired

Power Inspired VIS0750 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.