IBM ThinkPad R30 Manual

7015 Models R30, R40, and R50
CPU Enclosure
Operator Guide

Third Edition (April 1997)
This edition notice applies to the
7015 Model R30, R40, and R50 CPU Enclosure Operator Guide.
The following paragraph does not apply to the United Kingdom or any country where such
provisions are inconsistent with local law: THIS PUBLICATION IS PRINTED “AS IS” WITHOUT
WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some
states do not allow disclaimer of express or implied warranties in certain transactions; therefore, this
statement may not apply to you.
This publication could include technical inaccuracies or typographical errors. Changes are periodically made
to the information herein; these changes will be incorporated in new editions of the publication. The
manufacturer may make improvements and/or changes in the product(s) and/or program(s) described in this
publication at any time, without notice.
It is possible that this publication may contain reference to, or information about, products (machines and
programs), programming, or services that are not announced in your country. Such references or information
must not be construed to mean that such products, programming, or services will be offered in your country.
Any reference to a licensed program in this publication is not intended to state or imply that you can use only
the licensed program indicated. You can use any functionally equivalent program instead.
AIX is a registered trademark of International Business Machines.
Medeco is a trademark of Medeco Company.
Micro Channel is a trademark of International Business Machines.
SystemGuard is a trademark of International Business Machines.
Velcro is a trademark of Velcro Industries.
Copyright International Business Machines Corporation, 1994, 1997. All rights reserved.
Note to US Government Users – Documentation and programs related to restricted rights – Use, duplication,
or disclosure is subject to the restrictions set forth in the GSA ADP Schedule Contract.

Preface iii
Table of Contents
Communications Statements vii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety Notices xi. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
About This Book xiii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 1. CPU Enclosure Description 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CPU Enclosure 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Front View with Bezel Door Closed 1-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Front View with Bezel Door Open 1-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CPU Enclosure with Connectors (Rear View) 1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 2. Using the CPU Enclosure 2-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General Information about Multiple Systems 2-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The Operator Panel 2-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operator Controls 2-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setting the Key Mode Switch 2-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electronic Mode Switch 2-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reading the Operator Panel Display 2-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the Reset/Scroll Button 2-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the 3.5-Inch Diskette Drive 2-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the CD-ROM Drive 2-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type B Bezel (CD-ROM and CD-ROM2) CD-ROM Drive 2-13. . . . . . . . . . . . . . . . . . .
Type C Bezel CD-ROM Drive 2-15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the 1/4-Inch Internal Tape Drive 2-19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Status Light 2-19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setting the Write-Protect Tab on 1/4-Inch Tape Cartridges 2-20. . . . . . . . . . . . . . . . . .
Loading the 1/4-Inch Tape Cartridge 2-21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unloading the 1/4-Inch Tape Cartridge 2-22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mediag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . g General Informationnfo 15.GB 8 mml Tape Drive2-15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rcommendmatioms 2-15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Typs of 8 mml Tape Cartridges2-15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ape Cartridgr Cmpmatbilitay 2-63. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setting the Write-Protect Tab on8 mml Tape Cartridges2-63 . . . . . . . . . . . . . . . . . . . . .
Ciomidperatiomnnfo 8 mmlDatae Cartridges 2-63 . . . . . . . . . . . . . . . . . . .
2-79 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-79. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ape CartridgrDataeEfW 2-79. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the15.GB 8 mml Tape Drive2-99 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Status Lighes2-99 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Loading the8 mml Tape Cartridgs 2319 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unloading the8 mml Tape Cartridgs2321 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cleaning the TapePathb on the15.GB 8 mml Tape Drive2333 . . . . . . . . . . . . . . . . . . . .

iv Operator Guide
General Information for 4.0GB 4 mm Tape Drive 2-34. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Recommendations 2-35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Types of 4 mm Tape Cartridges 2-35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tape Cartridge Compatibility 2-36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setting the Write-Protect Tab on 4 mm Tape Cartridges 2-36. . . . . . . . . . . . . . . . . . . . .
Environmental Considerations for 4 mm Data Cartridges 2-36. . . . . . . . . . . . . . . . . . .
Operating in Harsh Environments 2-37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 mm Data Cartridge Erasure 2-37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tape Cartridge Data Capacity 2-37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the 4.0GB 4 mm Tape Drive 2-38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Status Lights 2-38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Loading the 4 mm Tape Cartridge 2-40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unloading the 4 mm Tape Cartridge 2-41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cleaning the Tape Path on the 4.0GB 4 mm Tape Drive 2-42. . . . . . . . . . . . . . . . . . . .
Chapter 3. Using SystemGuard 3-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Introduction 3-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SystemGuard Power 3-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SystemGuard Components 3-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SystemGuard Bring-Up MicroProcessor Overview 3-2. . . . . . . . . . . . . . . . . . . . . . . . . . . .
The Operator Panel 3-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SystemGuard Consoles 3-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Physical and Electronic Key 3-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SystemGuard Phases 3-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stand-By Phase 3-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Init Phase 3-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance Phase 3-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Boot Phase 3-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Run-Time Phase 3-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SystemGuard Parameters and Flags 3-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Working with SystemGuard 3-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SystemGuard Menus 3-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance Menu 3-21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Display Configuration 3-22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Display BUMP Error Log 3-25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Enable Service Console 3-25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Disable Service Console 3-25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reset 3-25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power-Off 3-25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System Boot 3-26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Off-Line Tests 3-28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Set Parameters 3-32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Set National Language 3-38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Some Common SystemGuard Tasks 3-39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Customizing SystemGuard For Your Needs 3-58. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reloading the Flash EEPROM 3-60. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 4. AC Rack Description 4-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC Rack 4-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC Rack with CPU Enclosure (Front View) 4-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Preface v
AC Rack Features 4-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC Rack with External Device Container, Cable Channel, and Rack Attachment Plate 4-2
Power Distribution Bus 4-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cluster Power Control 4-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Uninterruptible Power Source 4-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Distribution Unit (Supported) 4-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System Unit Devices 4-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SCSI-2 Drawer (Supported) 4-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC Rack Cables and the CPU Enclosure 4-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connectors 4-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Location Codes and Identification Labels 4-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Location Code Format for SCSI Devices 4-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Location Code Format for, 7135, 9333, and 9334 Expansion Units 4-13. . . . . . . . . . .
SCSI Drawer ID Label 4-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SCSI Device Address Label 4-15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cover Label 4-15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Creating Cover Labels 4-16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Location Code Format for Non-SCSI Devices 4-18. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Non-SCSI Drawer ID Label 4-18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Location Code Table for SCSI and Non-SCSI Devices 4-19. . . . . . . . . . . . . . . . . . . . . .
Chapter 5. Using the AC Rack 5-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Starting the AC Rack 5-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Methods of Starting the AC Rack 5-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stopping the AC Rack 5-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stopping the AC Rack Containing a PDU – Under Ordinary Conditions 5-7. . . . . . .
Immediately Stopping the AC Rack Containing a PDU 5-8. . . . . . . . . . . . . . . . . . . . . .
Stopping the AC Rack Containing a PDB – Under Ordinary Conditions 5-9. . . . . . .
Immediately Stopping the AC Rack Containing a PDB 5-10. . . . . . . . . . . . . . . . . . . . . .
Chapter 6. Description – -48 V dc Rack 6-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-48 V dc Rack 6-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Distribution Panel 6-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Cable Paths and the CPU Enclosure 6-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Location Codes and Identification Labels 6-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 7. Using the -48 V dc Rack 7-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setting the Key Mode Switch 7-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Starting the -48 V dc Rack 7-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Methods of Starting the -48 V dc Rack 7-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Manually Starting the -48 V dc Rack 7-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stopping the -48 V dc Rack 7-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stopping the -48 V dc Rack under Ordinary Conditions 7-3. . . . . . . . . . . . . . . . . . . . .
Stopping the -48 V dc Rack Immediately 7-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 8. Using the Diagnostics 8-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Diagnostic Programs Operating Considerations 8-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Diagnostics on a System Unit Attached to Another System 8-1. . . . . . . . . . . . . . . . . .
Selecting a Console Display 8-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Identifying the Terminal Type to the AIX operating system 8-1. . . . . . . . . . . . . . . . . . .
Running Diagnostic Programs From Tape Drives 8-2. . . . . . . . . . . . . . . . . . . . . . . . . .

vi Operator Guide
Running the Diagnostic Programs from Disk or From a Server 8-2. . . . . . . . . . . . . . .
Running the Diagnostic Programs from the Network 8-2. . . . . . . . . . . . . . . . . . . . . . .
Running the Diagnostic Programs from a TTY Terminal 8-3. . . . . . . . . . . . . . . . . . . . .
Diagnostic Modes of Operation 8-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance Mode 8-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Concurrent Mode 8-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standalone Mode 8-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System Exerciser 8-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CPU and Memory Testing and Error Log Analysis 8-11. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reading a Flashing 888 Message on a Multi-Line Operator Panel Display 8-12. . . . . . .
Step 1. Determine the Type of Message 8-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Step 2. Reading the Type 102 Message 8-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . erm . 0592582(8-12)]TJÏÈ32.7345 0 TDÏÈ-0.0505050505050505050505050505050505050505 . . . . 2554. . . .

Preface vii
Display and Change Diagnostic Test List Service Aid 9-10. . . . . . . . . . . . . . . . . . . . . . . . .
Display or Change Key Modes (Display or Change Electronic Mode Switch Task) 9-11
Display Previous Diagnostic Results Service Aid 9-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Display Test Patterns Service Aid 9-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Generic Microcode Download Service Aid 9-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hardware Error Report Service Aid and Display Hardware Error Log Task 9-12. . . . . . .
Local Area Network Service Aid and Local Area Network Analyzer Task 9-12. . . . . . . . .
Microcode Download Service Aid 9-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Multiprocessor Service Aid (Display or Change Multiprocessor Configuration Task) 9-12
Periodic Diagnostics Service Aid 9-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Topology Service Aid 9-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SCSI Bus Service Aid and SCSI Bus Analyzer Task 9-13. . . . . . . . . . . . . . . . . . . . . . . . . .
SCSI Tape Utilities Service Aid 9-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service Aids for use with Ethernet 9-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service Hints Service Aid 9-15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SSA Service Aid 9-15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Trace Service Aid 9-15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7318 Serial Communications Network Server Service Aid 9-16. . . . . . . . . . . . . . . . . . . . .
Chapter 10. Using the System Verification Procedure 10-1. . . . . . . . . . . . . . . . . . . . . .
Step 1. Considerations before Running This Procedure 10-1. . . . . . . . . . . . . . . . . . . . . . .
Step 2. Loading the Diagnostic Programs 10-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Step 3. Running System Verification 10-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Step 4. Additional System Verification 10-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Step 5. Stopping the Diagnostics 10-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 11. Hardware Problem Determination 11-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix A. SystemGuard Test Groups A-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SystemGuard Test Groups Table A-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SystemGuard Test Group Descriptions A-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BUMP Quick I/O Tests Group A-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
JTAG Test Group A-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Direct I/O Test Group A-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CPU Test Group A-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DCB and Memory Test Group A-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interrupt Tests Group A-19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CPU MultiProcessor Test Group A-20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix B. Modifying SystemGuard Parameters B-1. . . . . . . . . . . . . . . . . . . . . . . . .
Default Parameter Values B-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Changing Flags and Parameters Under AIX Service Aids B-3. . . . . . . . . . . . . . . . . . . . .
Modifying Diagnostic Flags B-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Modifying the Modem and Site Configuration B-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Saving or Restoring Flags and Configuration Information B-3. . . . . . . . . . . . . . . . . . .
Modifying the Remote Authorization Flag B-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SystemGuard Stand-by Menu B-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SystemGuard Maintenance Menu B-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AIX Diag Command B-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Modifying the Dial-Out Authorization Flag B-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SystemGuard Maintenance Menu B-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

viii Operator Guide
AIX Diag Command B-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Modifying Dial-In Phone Numbers B-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SystemGuard Maintenance Menu B-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AIX Diag Command B-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Modifying Dial-Out Phone Numbers B-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SystemGuard Maintenance Menu B-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AIX Diag Command B-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Modifying the Electronic Mode Switch from Service Line Flag B-6. . . . . . . . . . . . . . . . . .
SystemGuard Maintenance Menu B-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AIX Diag Command B-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reloading the Flash EEPROM B-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Prerequisites B-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reloading the Flash EEPROM (stand-by phase) B-7. . . . . . . . . . . . . . . . . . . . . . . . . . .
Reloading the Flash EEPROM (run-time phase) B-7. . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix C. SystemGuard Remote Operation Configuration C-1. . . . . . . . . . . . . . .
Terminal Configuration C-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Flags and Parameters Settings C-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Modem Configuration Files C-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Initializing a Modem C-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Testing Dial-Out C-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix D: Supplies D-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ordering Keys D-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Key Reorder Form D-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix E. Operator Panel Display Numbers E-1. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power-On (PON) Test Indicators E-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power-On Self-Test (POST) Indicators E-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration Program Indicators E-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Diagnostic Load Progress Indicators E-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix F. System Power States F-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power States F-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MAIN_STANDBY F-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SBB_GATEWAY F-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SBB_ECMD F-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SBB_PCMD F-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SBB_MENU F-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WAIT_POWER_ON F-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IPL F-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AIX F-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WAIT_REBUILDING F-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How to Turn System Power On from the BUMP Console F-3. . . . . . . . . . . . . . . . . . . .
How to Turn System Power On Using the Power-on Button F-4. . . . . . . . . . . . . . . . .
Glossary: Special Terms Used in SystemGuard X-1. . . . . . . . . . . . . . . . . . . . . . . . . . .
Index X-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Preface ix
Communications Statements
The following statement applies to this product. The statement for other products intended
for use with this product appears in their accompanying manuals.
Federal Communications Commission (FCC) Statement
Note: This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his
own expense.
Properly shielded and grounded cables and connectors must be used in order to meet FCC
emission limits. Neither the provider nor the manufacturer are responsible for any radio or
television interference caused by using other than recommended cables and connectors or
by unauthorized changes or modifications to this equipment. Unauthorized changes or
modifications could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired
operation.
United Kingdom Telecommunications Safety Requirements
This equipment is manufactured to the International Safety Standard EN60950 and as such
is approved in the UK under the General Approval Number NS/G/1234/J/100003 for indirect
connection to the public telecommunication network.
The network adapter interfaces housed within this equipment are approved separately, each
one having its own independent approval number. These interface adapters, supplied by the
manufacturer, do not use or contain excessive voltages. An excessive voltage is one which
exceeds 70.7 V peak ac or 120 V dc. They interface with this equipment using Safe Extra
Low Voltages only. In order to maintain the separate (independent) approval of the
manufacturer’s adapters, it is essential that other optional cards, not supplied by the
manufacturer, do not use main voltages or any other excessive voltages. Seek advice from a
competent engineer before installing other adapters not supplied by the manufacturer.
European Union (EU) Statement
This product is in conformity with the protection requirements of EU Council Directive
89/336/EEC on the approximation of the laws of the Member States relating to
electromagnetic compatibility.
Neither the provider nor the manufacturer can accept responsibility for any failure to satisfy
the protection requirements resulting from a non-recommended modification of the product,
including the fitting of option cards not supplied by the manufacturer.
This product has been tested and found to comply with the limits for Class A Information
Technology Equipment according to CISPR 22 / European Standard EN 55022. The limits

xOperator Guide
for Class A equipment were derived for commercial and industrial environments to provide
reasonable protection against interference with licensed communication equipment.
Attention: This is a Class A product. In a domestic environment this product may cause
radio interference in which case the user may be required to take adequate measures.
International Electrotechnical Commission (IEC) Statement
This product has been designed and built to comply with IEC Standard 950.
Avis de conformité aux normes du ministère des Communications du
Canada Cet appareil numérique de la classe A respecte toutes les exigences du Réglement sur le
matériel brouilleur du Canada.
Canadian Department of Communications Compliance Statement
This Class A digital apparatus meets the requirements of the Canadian
Interference-Causing Equipment Regulations.
VCCI Statement
The following is a summary of the VCCI Japanese statement in the box above.
This equipment is in the Class 1 category (information equipment to be used in
commercialand/orindustrialareas)andconformstothestandardssetbytheVol-
untaryControl Council ForInterferencebyDataProcessingEquipment and Elec-
tronic Office Machines aimed at preventing radio interference in commercial and/
or industrial areas.
Consequently,whenusedinaresidentialareaorinanadjacentareathereto,radio
interference may be caused to radios and TV receivers, etc.
Read the instructions for correct handling. VCCI–1.

Preface xi
Radio Protection for Germany
Dieses Gerät ist berechtigt in Übereinstimmung mit dem deutschen EMVG vom 9.Nov.92
das EG-Konformitätszeichen zu führen.
Der Aussteller der Konformitätserklärung ist die IBM Germany.
Dieses Gerät erfüllt die Bedingungen der EN 55022 Klasse A. Für diese Klasse von Geräten
gilt folgende Bestimmung nach dem EMVG:
Geräte dürfen an Orten, für die sie nicht ausreichend entstört sind, nur mit besonderer
Genehmigung des Bundesministers für Post und Telekommunikation oder des Bundesamtes
für Post und Telekommunikation betrieben werden. Die Genehmigung wird erteilt, wenn
keine elektromagnetischen Störungen zu erwarten sind.
(Auszug aus dem EMVG vom 9.Nov.92, Para.3, Abs.4)
Hinweis:
Dieses Genehmigungsverfahren ist von der Deutschen Bundespost noch nicht veröffentlicht
worden.

xii Operator Guide

Preface xiii
Safety Notices
Note: For a translation of these notices see the
System Unit Safety Information
, form
number SA23-2652.
Definitions of Safety Notices
A
danger
notice indicates the presence of a hazard that has the potential of causing death
or serious personal injury.
Danger
notices appear on the following pages:
4-11
7-1
A
caution
notice indicates the presence of a hazard that has the potential of causing
moderate or minor personal injury.
Caution
notices appear on the following pages:
2-13
2-15
4-3
4-6
4-7
4-11
5-3
5-5
7-1
An
attention
notice indicates an action that could cause damage to a program, device,
system, or data.

xiv Operator Guide
Laser Safety Information
The optical drive in this system unit is a laser product. The optical drive has a label that
identifies its classification. The label, located on the drive, is shown below.
CLASS 1 LASER PRODUCT
LASER KLASSE 1
LUOKAN 1 LASERLAITE
APPAREIL A LASER DE CLASSE 1
TO IEC 825:1984 CENELEC EN 60 825:1991
The optical drive in this system unit is certified in the U.S. to conform to the requirements of
the Department of Health and Human Services 21 Code of Federal Regulations (DHHS 21
CFR) Subchapter J for Class 1 laser products. Elsewhere, the drive is certified to conform to
the requirements of the International Electrotechnical Commission (IEC) 825 (1st edition
1984) and CENELEC EN 60 825:1991 for Class 1 laser products.
CAUTION:
A class 3 laser is contained in the device. Do not attempt to operate the drive while it
is disassembled. Do not attempt to open the covers of the drive as it is not
serviceable and is to be replaced as a unit.
Class 1 laser products are not considered to be hazardous. The optical drive contains
internally a Class 3B gallium-arsenide laser that is nominally 30 milliwatts at 830
nanometers. The design incorporates a combination of enclosures, electronics, and
redundant interlocks such that there is no exposure to laser radiation above a Class 1 level
during normal operation, user maintenance, or servicing conditions.

Preface xv
About This Book
This book provides information about the operator controls and the devices installed in the
7015 system unit.
Definition of Machine Names and Model Numbers
The models of CPU Enclosures referred to in this book are the 7015 Model R30, R40, and
R50. References to CPU Enclosures in this book apply to the 7015 Models R30, R40, or
R50 CPU Enclosures.
Note: This publication is used with a system containing the 7015 CPU Enclosure, or any
system that is upgraded from a system containing the 7015 CPU Drawer or
Enclosure to a Model R30, R40, or R50 CPU Enclosure.
ISO 9000 ISO 9000 registered quality systems were used in the development and manufacturing of
this product.
Related Publications
The
7015 Model R30, R40, and R50 CPU Enclosure Installation and Service Guide
, form
number SA23-2743, provides installation and maintenance information for the CPU
enclosure.
The
7015 Model R00 Rack Installation and Service Guide
, form number SA23-2744,
provides installation and maintenance information for the rack.
The
AIX System Management Guide: Operating System and Devices
manual, form number
SC23-2525, contains information about using the operating system with options and
devices.
The
AIX Problem Solving Guide and Reference
(form number SC23-2606), is the first book
you should use when you have a problem with the system unit. It contains procedures for
determining if the problem is hardware or software related.
The
9348 Customer Information
manual, form number SA21-9567, contains operating and
cleaning instructions for the tape unit.
The
Site and Hardware Planning Information
manual, form number SA38-0508, provides
information for planning the installation of a RISC System/6000.
The
Adapters, Devices, and Cable Information
manual, form number SA23-2764, contains
information to indentify adapters, service some devices, and design or service some cable
layouts.
The
System Unit Safety Information
manual, form number SA23-2652, contains translations
of danger and caution notices.

xvi Operator Guide

Description 1-1
Chapter 1. CPU Enclosure Description
This chapter contains information about system unit features, parts, and devices on the
7015 Model R30, R40, or R50 CPU Enclosures.
CPU Enclosure
The 7015 CPU Enclosures are rack-mounted CPUs containing a CPU module, I/O module,
media module, and a power supply with a possible optional second power supply.
The CPU module is located in the front half of the CPU enclosure and contains CPU cards,
memory cards, and an I/O card.
The media module is located above the CPU module at the front of the CPU enclosure and
contains a disk drive, CD-ROM drive, an optional media position for either a 5.0GB 8 mm
tape drive, 4GB 4 mm tape drive, 1/4-inch tape drive, or another CD-ROM drive, and an
operator panel assembly containing a 3.5-inch diskette drive. The R50 Media Module has a
position for an optional second disk drive.
The I/O module is located in the rear half of the CPU enclosure and contains two I/O planars
containing a total of 16 Micro Channel adapter slots. The power supply and optional second
power supply position are located above the adapter positions.
A system interface board (SIB) is located next to the I/O module and contains an RS485 port
(in) an RS485 port (out), a Battery Backup Unit (BBU) connector, parallel port, serial port 1,
serial port 2, and serial port 3.
The CPU Enclosure can be installed in a 7015 Model R00 rack with other optional
compatible drawers and devices such as disk drive drawers and SCSI media drawers. The
power distribution system in a 7015 Model R00 rack can contain either a power distribution
bus, power distribution unit, or a battery backup unit. For information about options and
compatible optional drawers that can be used with the 7015 Model R30 CPU Enclosure in a
7015 Model R00 rack, see the
Adapters, Devices, and Cable Information
manual, form
number SA23-2764.

1-2 Operator Guide
Front View with Bezel Door Closed
Bezel Door
(Closed Position)
Front View with Bezel Door Open
CD-ROM Drive
Optional
Media
Position
Operator
Panel 3.5-Inch
Diskette
Drive

Description 1-3
CPU Enclosure with Connectors (Rear View)
Parallel
Port
Serial
Port 1
Serial
Port 2
Adapter Locations Adapter Locations
Serial
Port 3
RS485 (Out)
Battery
Backup Unit
Connector
RS485 (In)
0/1
1/1
0/2
0/3
0/4
0/5
0/6
0/7
0/81/2
1/3
1/4
1/5
1/6
1/7
1/8

1-4 Operator Guide
Other manuals for ThinkPad R30
5
This manual suits for next models
2
Table of contents
Other IBM Processor manuals