ICA FRc Series User manual

FERRO
RESONANT
CONTROLLED
1000
2000
3000
5000
7501C1
FRc-SERIES
ICA
481-1270010-111Rev. 01
USER’S MANUAL
BUKU PETUNJUK PEMAKAIAN
F R c

I.
II.
III.
IV.
V.
VI.
SAFETY NOTES / CATATAN KESELAMATAN
INTRODUCTION / PENDAHULUAN
TECHNICAL SPECIFICATION / SPESIFIKASI TEKNIK
FRONT PANEL & REAR PANEL VIEW /
TAMPAK PANEL DEPAN & PANEL BELAKANG
FRc INSTALLATION / PEMASANGAN FRc
OPERATION PROCEDURE / CARA MENGOPERASIKAN
Page / Halaman
1
3
3
4
5
5
CONTENTS / DAFTAR ISI

I. SAFETY NOTES / CATATAN KESELAMATAN
1
I.1. Electrical Safety
I.2. Deenergizing Safety
● If the UPS has an internal energy source (battery), the
output may be energized when the unit is not connected to a
utility power outlet.
● To deenergize a pluggable UPS, press the OFF button or
switch to shut the equipment off. Unplug the UPS from the
utility power outlet. Disconnect the external batteries where
applicable and disconnect the internal battery. Push the ON
button to deenergize the capacitors.
I.1. Keselamatan Listrik
● .Jangan bekerja sendiri dalam situasi berbahaya
● Tegangan tinggi melalui bahan konduktif dapat
menyebabkan luka bakar.
● Periksa agar kabel listrik, fiting, dan soket berada dalam
kondisi baik.
● Bila grounding tak dapat diverifikasi, putuskan hubungan
peralatan listrik dengan keluaran listrik AC sebelum
memasang atau menghubungkannya dengan peralatan lain.
Hubungkan kembali dengan kabel listrik hanya jika
seluruhnya selesai dihubungkan.
● Hubungkan peralatan ke keluaran listrik AC tiga kabel
(dua kutub dan ground). Soket penerima harus terhubung
secara benar melalui sirkuit cabang/pelindung utama
(sekring atau pemutus arus). Hubungan ke soket penerima
dalam bentuk lainnya dapat menyebabkan bahaya sengatan
listrik.
● Jika alat memiliki sumber energi internal (baterai), output
mungkin masih mengandung arus listrik walaupun unit
tidak terhubung dengan tegangan listrik AC.
● Untuk membuang arus listrik dari UPS yang terhubung,
tekan tombol OFF untuk mematikan alat. Putuskan alat dari
outlet listrik AC. Lepaskan batterai dan putuskan batterai
internal. Tekan tombol ON untuk membuang listrik di
dalam kapasitor.
I.2. Keselamatan Saat Membuang Arus Listrik

Jangan buang sisa kemasan produk ini sebagai limbah rumah
tangga: Bawa ke tempat pengumpulan untuk didaur ulang.
Untuk informasi tentang tempat daur ulang terdekat, hubungi
petugas pembuangan limbah setempat.
Pembuangan produk
Unit berisi bahan internal yang (dalam kasus pembuangan)
dianggap LIMBAH BERACUN dan BERBAHAYA, seperti
papan sirkuit elektronik. Perlakukan bahan-bahan ini sesuai
dengan undang-undang yang berlaku dengan merujuk pada
personel servis yang berkualifikasi. Pembuangan yang tepat
berkontribusi untuk menghormati lingkungan dan kesehatan
manusia.
Disposing of the product
The unit contains internal material that (in case of disposal) are
considered TOXIC and HAZARDOUS WASTE, such as
electronic circuit boards. Treat these materials according to the
laws applicable referring to qualified service personnel. Their
proper disposal contributes to respect the environment and
human health.
Do not dispose of leftover packaging for this product as
household waste: Take it to a collection point for recycling.
For information about the nearest recycling facility, contact
your local waste disposal authority.
2

ICA Ferro Resonant controlled stabilizer is a special
stabilizer design that use high quality component. This
stabilizer type has a very fast response time 0.1 seconds,
because it does not have mechanical component like in the
servo motor stabilizer type.
Ferro Resonant controlled is not only a voltage stabilizer,
but also spike and surge suppressor to protect sensitive
electronic equipment as computer, telecommunication
systems and other electronic equipment.
ICA Ferro Resonant controlled adalah stabilizer yang
dirancang secara khusus dengan menggunakan komponen-
komponen pilihan yang berkualitas tinggi. Stabilizer ini
mempunyai waktu reaksi yang sangat cepat yaitu 0.1 detik, hal
ini disebabkan tidak terdapat komponen mekanik seperti pada
tipe stabilizer servo motor..
Ferro Resonant controlled bukan hanya mengatasi
ketidakstabilan tegangan tapi juga spikes dan surges untuk
peralatan elektronik yang sensitif seperti komputer, sistem
komunikasi dan peralatan elektronik lainnya.
II. INTRODUCTION / PENDAHULUAN
Hz
A
V
Hz
Sec
OC
mm
Kg
MCB
D x W x H
Frequency
Protection
Voltage
Frequency
Response Time
Operation Temperature
Dimension
Weight
50
10
220 ± 2%
50
0,1
0 ~ 40
320x242x210
11,5
480x230x467 630x264x682
16,5 35,5 40,5 62,5
16 20 32 40
ITEM SPECIFICATIONS
UNIT
V 170 - 250
REMARKS
Voltage
FRc1000 FRc2000 FRc3000 FRc5000 FRc7501C1
III. TECHNICAL SPECIFICATION / SPESIFIKASI TEKNIK
AC
IN
VA 1000 2000 3000 5000 7500 Maximum CAPACITY
AC
OUT
MODEL
3

1
2
10
10
4
3
1
2
10
9
8
7
10
10
8
7
10
2
9
5
6
IV. FRONT PANEL & REAR PANEL VIEW / TAMPAK PANEL DEPAN & PANEL BELAKANG
1. AC Voltmeter
2. MCCB
3. Outlet / Stopkontak Output
4. Input AC Cable / Kabel AC Input
5. Green Lamp: Indicate AC Input
6. Yellow Lamp: Indicate Regulated AC Output
7. Input Terminal / Terminal Input
8. Output Terminal / Terminal Output
9. Cable Hole / Lubang Kabel
10. Ventilation / Lubang Angin
REAR PANEL VIEWFRONT PANEL VIEW
FRc1000, FRc2000
REAR PANEL VIEWFRONT PANEL VIEW
FRc3000, FRc5000
REAR PANEL VIEWFRONT PANEL VIEW
FRc7501C1
4

V. FRc INSTALLATION / PEMASANGAN FRc
1. Location selection:
a. Put this Frc on the protected place.
b. Do not blocking the air flow and retain 10 cm between
wall and other equipment.
2. Cable installation:
a. Connect input cable (FRc1000, FRc2000) or cable
between input terminal (FRc3000, FRc5000,
FRc7501C1) to power line have safety circuit breaker.
b. Turn ON the MCB on the front panel or rear panel and
Ferro Resonant controlled ready to work.
1. Pemilihan lokasi:
a. Letakkan Frc ini pada tempat yang terlindung.
b. Lubang ventilasi jangan tertutup dan beri jarak minimal
10 cm dari dinding atau peralatan lainnya.
2. Pemasangan kabel:
a. Hubungkan kabel AC input (FRc1000, FRc2000) atau
kabel antara terminal blok AC input (FRc3000,
FRc5000, FRc7501C1) dengan sumber daya listrik
yang mempunyai pengaman (circuit breaker).
b. Hidupkan MCB pada panel depan atau panel belakang
dan Ferro Resonant controlled siap pakai.
VI. OPERATION PROCEDURE / CARA MENGOPERASIKAN
1. Turn ON procedure:
a. Turn ON the MCB on the front panel or rear panel
b. Turn ON the load that are connected to the output.
2. When line power not stabilized, output voltage stable in
within 0.1 seconds.
1. Menghidupkan Ferro Resonant controlled:
a. Hidupkan MCB pada panel depan atau panel belakang.
b. Hidupkan beban yang terpasang pada output.
2. Pada saat tegangan input tidak stabil, tegangan output
distabilkan dalam waktu 0.1 detik.
5

SERVICE CENTRE
ICA
Jln. Pinangsia Raya I No: 22BB
Jakarta - 11120
Phone : (021) 6906020 (Hunting)
ICA
Notes :
For further information, please visit “www.icaups.co.id”.
----------------------------------------------------------------------------------
Catatan :
Untuk informasi lebih lanjut, silakan kunjungi “www.icaups.co.id”.
This manual suits for next models
5
Table of contents