EUROC 4 INSTALLATION
Top view
2. FILLING THE BRINE DEPOSIT WITH SALT
The brine deposit should be fill up with salt.
3. START UP
Fill with water half the bin. Wait around 15 minutes. If posible, wait 3 to 4
hours before starting the unit the first time.
Connect to power and program as folllows:
Time of day: press until desired hour
appears. Release.
Range: 0 through 23 hours
Note: The elapsed minutes will reset to
zero when the hours are changed.
Regenerant dosage: Press until
desired regenerant dosage appears.
Release.
Range: 0,20 kg to 6,0 kg
0,20 kg to 1,0 kg by increments of 0,05 kg
1,0 kg to 3,0 kg by increments of 0,1 kg
3,0 kg to 6,0 kg by increments of 0,5 kg
Default: 0,6 kg
Capacity Cubic Meters: Press until
desired interval appears.
Release.
Range: 0,40 to 9,cubic meters
0,40 m3 t 1,0 m3 by increments of 0,05 m3
(12 increments)
1,0 m3 to 3,0 m3 by increments of 0,1 m3
(20 increments)
3,0 m3 to 5,0 m3 by increments of 0,2 m3
(10 increments)
5,0 m3 to 9,5 m3 by increments of 0,05 m3
(10 increments)