iCleanse Swift 5x User manual

User Guide for your Swift 5x

About your iCleanse Swift 5x
Important Safety Instructions
Meet your iCleanse Swift 5x
Indicators
Tech Specs
Getting Started
Setting up your Swift 5x
Admin Mode
Using and Maintaining your Swift 5x
Guidelines for Use
Disinfecting Devices
Lamp Status & Replacement
Resetting the Lamp Cycle Counter
Troubleshooting
Warranty and Registration
Customer Support
2
3
4
6
7
8
9
10
12
13
14
15
16
Contents
1

About your iCleanse Swift 5x
2
READ ALL INSTRUCTIONS BEFORE USING THIS DEVICE
CAUTION: This device emits ultraviolet radiation. The device has been
designed to contain UV exposure. Do not attempt to make modifications to the
device or attempt to look directly at the UV lamps while it is in operation. UV
light can cause discoloration with continuous exposure to plastic devices that
are white or light in color.
WARNING: For the continued protection against risk of fire, replace only with
fuse of the specified type and current ratings.
Do not use outdoors or on wet surfaces.
Use device only as described in this manual.
Turn off the device before unplugging.
Any service should be performed by an authorized service representative
CAUTION: Double pole/neutral fusing.
Important Safety Instructions

The iCleanse Swift 5x provides a chemical-free, general-purpose disinfection for
mobile phones and tablets.
The Swift 5x has been designed for minimal contact with what you place
in it, allowing maximum surface coverage by germicidal light during the
disinfection cycle.
Please read through this guide thoroughly to ensure proper use of your Swift 5x.
Meet your Swift 5x
About your iCleanse Swift 5x
3

About your iCleanse Swift 5x
4
The iCleanse Swift 5x has an easy-to-use interface. Below are the various lighted
buttons and their functions.
Cycle Time Remaining Progress Bar: Shows the remaining time in the
disinfection cycle.
Admin Mode: Illuminates when you are in administrator mode.
Service Lamps: Illuminates when it’s time to replace your lamps.
Stop Button: Stops the disinfection cycle.
Lock Button: Locks all trays of the unit. The light under this button indicates that
the unit is locked.
Start Button: Starts the disinfection cycle for all trays.
Disinfecting: Indicates that the drawer is being disinfected.
Charging: Indicates that a device is being charged.
Tray Open: Indicates that the tray is open.
Indicators

5
About your iCleanse Swift 5x
Figure 01. Swift 5x Keypad
Tray Information
Provides status of each
individual tray
Lock Light
Indicates when the unit
is locked
Cycle Time Remaining
Progress Bar
Disinfection is complete
when all lights in the
progress bar are no
longer lit
Numerical Keypad
Used to access admin mode,
change system settings,
and start an individual
disinfection cycle

Getting Started
6
Tech Specs
Model Swift 5x
Dimensions 15.5 in x 17.5 in x 17.75 in / 39.4 cm x 44.5 cm x 45 cm
Weight 46 lbs / 20.8 kg
Basket Accommodations 8.5 in x 11 in x .75 in / 22 cm x 28 cm x 2 cm
Disinfection Cycle Time Set at Factory — Default is 120 seconds
Operating Temp. Range 37°F - 95°F / 2.78°C - 35°C
Operating Humidity Range 5-95% @ 82.4°F / 5-95% @ 28°C
Storage Humidity Range 0-95% Non-condensing
AC Supply Voltage 120VAC - 240VAC
Installation Requirements Level Surface; 3 in / 7.5 cm from obstruction
Power Cord Length 6.5 ft / 2 m

Getting Started
7
Ensure the Swift 5x unit is on a level surface and has 3 to 4 inches of open space
behind it to allow for proper airflow for the cooling fan.
Plug in the power cord to any standard outlet and power in the unit by using the
switch on the back.
Setting up your Swift 5x

8
Getting Started
Admin mode allows the user to create and change pass codes for admins and
users as well as reset the lamp counter.
Entering Admin Mode
Step 1: Turn the unit on.
Step 2: Press and continue to hold the “+” key while entering the admin PIN. The
default PIN is 1234.
Step 3: To exit admin mode, press and hold the “-” key and enter the admin PIN.
Admin mode will also exit after 60 seconds of inactivity.
PIN Management
There are two types of PINs stored in the iCleanse’s memory — administrator
PINs and user PINs. The unit must be in admin mode to make these changes.
User PIN: Lock and Unlock unit (maximum of 16 four-digit PINs)
Administrator PIN: Make system changes, add and remove users and
administrators (maximum of 4, four-digit PINs)
Adding and deleting PIN’s
Add an admin PIN by entering admin mode, then entering “++XXXX” and delete
by entering “--XXXX” (XXXX to be replaced by your desired 4-digit PIN)
Add a user PIN by entering “+XXXX” and delete by entering “-XXXX”
Delete all user PINs by entering “+99” (this will not delete the admin PINs)
Admin Mode

9
Using and Maintaining your Swift 5x
Guidelines for Use
Non-Critical Devices: iCleanse Swift 5x units should be used on devices
classified as non-critical. “Non-Critical” medical devices are devices that are in
contact with unbroken skin only.
General Purpose Disinfection: This is described as a germicide intended to
process non-critical medical devices and equipment surfaces. Germicide is an
agent that kills germs, like pathogenic microorganisms.
Cleaning vs Disinfecting: The iCleanse Swift 5x’s germicidal lamps will not
penetrate dirt and grime, therefore it is highly recommended that you still
periodically clean your devices. Cleaning is not disinfecting and vice versa.
Lamp Recycling: Please visit www.lamprecycle.org for information on recycling
your lamps after use.
Expectations: Due to the progressive application of UV-C light, the devices being
disinfected may experience color change over time.
Power Cord: Do not store the power cord inside the unit as it may cause
damage to the inside of the unit.

10
Using and Maintaining your Swift 5x
There are three ways to disinfect with your Swift 5x.
Method 1: Dock, charge, disinfect multiple devices at once.
Step 1: Open a tray and place your device in the basket.
Step 2: To charge the device, plug into the USB port at the back of the tray. Please
note that USB charging cables are not provided.
Step 3: Close the tray.
Step 4: Repeat until all devices are in the unit as needed. The unit will automatically
begin charging and disinfecting after 7 seconds once a device is plugged into any
of the USB port and all trays are closed. You do not have to press the start button
if you’re charging as well as disinfecting.
Step 5: The unit automatically locks when the disinfection cycle is in process. You
will not be able to open the trays or remove devices until the cycle completes.
Step 6: The cycle is complete when all the “DISINFECTING” lights are solid blue.
Method 2: Disinfect a single device on the fly.
Step 1: Open any tray and place your device in the basket.
Step 2: Close the tray.
Disinfecting

11
Using and Maintaining your Swift 5x
Step 3: Press and hold the number on the keypad that corresponds to the
tray you are disinfecting to start a disinfection cycle.
Step 4: Wait for the disinfection cycle to complete.
Step 5: Open the tray and remove the disinfected device.
Method 3: Disinfect multiple devices on the fly.
Step 1: Open any tray and place your device in the basket.
Step 2: Close the tray.
Step 3: Repeat steps 1 & 2 until all devices are in the unit.
Step 4: Press and hold the start button to disinfect all trays.
Step 5: The unit automatically locks when the disinfection cycle is in process. You
will not be able to open the trays or remove devices until the cycle completes.
Step 6: The cycle is complete when all the “DISINFECTING” lights are solid blue.
*All trays must be closed for the disinfection process to begin.
**Press the stop button if you need to interrupt the disinfection cycle.

12
Using and Maintaining your Swift 5x
Each set of lamps has a lifespan of 4,000 cycles.
When lamps reach 500 cycles remaining, the Service lamps light will turn on.
When there are 0 cycles remaining you can no longer run a disinfection cycle. To
learn how to replace your lamps go to: www.icleanse.com/support.
Lamp Status & Lamp Replacement

13
Using and Maintaining your Swift 5x
After replacing the lamps follow this procedure to reset the lamp cycles to 4,000.
Step 1: Hold “+” and enter 1234” on the keypad.
Step 2: You will hear a beep along with the “ADMIN MOSE” light illuminating on
the front panel.
Step 3: Enter “+77+0000” on the keypad.
Step 4: You should hear a beep and see the “SERVICE LAMPS” light on the front
panel turning off.
Step 5: Hold “-” and enter “1234” on the keypad.
Step 6: You will hear a beep along with the “ADMIN MODE” light on the front
panel turning off.
Step 7: Switch off the unit and turn it back on after 5 seconds.
Resetting the Lamp Cycle Counter

14
Troubleshooting
If you are having trouble with your Swift 5x unit, please see the following solutions.
Light illuminates the tray is open while closed
Open the tray and check for any obstructions in the bay. Close the tray and check
that the Tray Open light is off.
Tray won’t close (visibly)
Clear any obstructions. If the problem persists, contact iCleanse.
Unit does not power on
Check and replace fuses at the power cord connection point.
Unexpected display or control panel behavior
Cycle power switch off/on.
Trays won’t unlock
Use the default PIN code 1234.
Troubleshooting

15
For iCleanse Swift 5x Warranty
Each iCleanse product comes with a full 1-year warranty upon registration of
your product. For more info visit www.icleanse.com/warranty.
Registration
Please visit www.icleanse.com/warranty to register your new Swift 5x within 30
days of your purchase to activate your one year warranty.
Warranty and Registration
US Patent Numbers: 8296493, 8606981,
8977796, 9254342, 10166308
Warranty and Registration

16
iCleanse offers comprehensive support
from our in-house customer experience
team. Available Monday thru Friday
9:00am - 5:00pm
Please keep your model number, serial number, and purchase date on hand for
any future support.
Model Number
Order Number
Purchase Date
We’re Here to Help
800.969.1166
icleanse.com/support
Customer Support

Follow our social media accounts for the most up to date news.
Connect with Us
/icleansellc @_icleanse @_icleanse /icleanse
icleanse.com
© 2021
17
Table of contents
Popular Steriliser manuals by other brands

Market Forge Industries
Market Forge Industries Sterilmatic Installation & operation manual

Selecta
Selecta STERIL-FOOD manual

Philips
Philips Avent SCF288 Important product information

Godrej
Godrej UV CASE quick start guide

Crystal Clear
Crystal Clear AQUA PRO 12 GPM Installation & maintenance

oneConcept
oneConcept 10018119 manual