EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ICP DAS USA
  6. •
  7. I/O System
  8. •
  9. ICP DAS USA EIP-2000 Series User manual

ICP DAS USA EIP-2000 Series User manual

Other manuals for EIP-2000 Series

2

Other ICP DAS USA I/O System manuals

ICP DAS USA ET-7000/PET-7000 Series User manual

ICP DAS USA

ICP DAS USA ET-7000/PET-7000 Series User manual

ICP DAS USA A-8111 Series User manual

ICP DAS USA

ICP DAS USA A-8111 Series User manual

ICP DAS USA A-626 User manual

ICP DAS USA

ICP DAS USA A-626 User manual

ICP DAS USA M-7018Z User manual

ICP DAS USA

ICP DAS USA M-7018Z User manual

ICP DAS USA ET-7000 series User manual

ICP DAS USA

ICP DAS USA ET-7000 series User manual

ICP DAS USA PETL Series User manual

ICP DAS USA

ICP DAS USA PETL Series User manual

ICP DAS USA I-7061D User manual

ICP DAS USA

ICP DAS USA I-7061D User manual

ICP DAS USA PROFI-8455 Setup guide

ICP DAS USA

ICP DAS USA PROFI-8455 Setup guide

ICP DAS USA tM-AD4P2C2 User manual

ICP DAS USA

ICP DAS USA tM-AD4P2C2 User manual

ICP DAS USA tM-P8 User manual

ICP DAS USA

ICP DAS USA tM-P8 User manual

ICP DAS USA M-7059 Installation guide

ICP DAS USA

ICP DAS USA M-7059 Installation guide

ICP DAS USA ET-2200 Series User manual

ICP DAS USA

ICP DAS USA ET-2200 Series User manual

ICP DAS USA A-823PGH Series User manual

ICP DAS USA

ICP DAS USA A-823PGH Series User manual

ICP DAS USA tM-P8 User manual

ICP DAS USA

ICP DAS USA tM-P8 User manual

ICP DAS USA CAN-2084C User manual

ICP DAS USA

ICP DAS USA CAN-2084C User manual

ICP DAS USA ISO-P32S32W User manual

ICP DAS USA

ICP DAS USA ISO-P32S32W User manual

ICP DAS USA 7188X User manual

ICP DAS USA

ICP DAS USA 7188X User manual

ICP DAS USA CAN-2057C User manual

ICP DAS USA

ICP DAS USA CAN-2057C User manual

ICP DAS USA I-8017 Series User manual

ICP DAS USA

ICP DAS USA I-8017 Series User manual

ICP DAS USA SG-3071-G User manual

ICP DAS USA

ICP DAS USA SG-3071-G User manual

ICP DAS USA PCI-D64HU User manual

ICP DAS USA

ICP DAS USA PCI-D64HU User manual

ICP DAS USA PCI-D64HU User manual

ICP DAS USA

ICP DAS USA PCI-D64HU User manual

ICP DAS USA I-9018W User manual

ICP DAS USA

ICP DAS USA I-9018W User manual

ICP DAS USA DB-16R User manual

ICP DAS USA

ICP DAS USA DB-16R User manual

Popular I/O System manuals by other brands

WAGO 750-344 manual

WAGO

WAGO 750-344 manual

Teknim TWM-1887 Installation & user manual

Teknim

Teknim TWM-1887 Installation & user manual

Intelligent Appliance IA-2662-E user manual

Intelligent Appliance

Intelligent Appliance IA-2662-E user manual

BERGHOF ECC DIO 16/16 User handbook

BERGHOF

BERGHOF ECC DIO 16/16 User handbook

Advantech PCM-27J3AU Startup manual

Advantech

Advantech PCM-27J3AU Startup manual

Festo CP-E08-M12-CL manual

Festo

Festo CP-E08-M12-CL manual

Measurement Computing PCI-DAS64/M1/16 user guide

Measurement Computing

Measurement Computing PCI-DAS64/M1/16 user guide

Hitachi HX-RIO3 Series user manual

Hitachi

Hitachi HX-RIO3 Series user manual

NUUO SCB-A08 user manual

NUUO

NUUO SCB-A08 user manual

M-system R3Y-RS8 instruction manual

M-system

M-system R3Y-RS8 instruction manual

jablotron JB-110N user manual

jablotron

jablotron JB-110N user manual

Omron SYSMAC C200H Operation guide

Omron

Omron SYSMAC C200H Operation guide

DOLD SAFEMASTER M Safety Technique

DOLD

DOLD SAFEMASTER M Safety Technique

ABB OPT-MF-001 user manual

ABB

ABB OPT-MF-001 user manual

Omron SYSMAC C2000H Operation guide

Omron

Omron SYSMAC C2000H Operation guide

Helmholz TB20 manual

Helmholz

Helmholz TB20 manual

Automationdirect.com DL305 manual

Automationdirect.com

Automationdirect.com DL305 manual

WAGO I/O SYSTEM 750 750-833 manual

WAGO

WAGO I/O SYSTEM 750 750-833 manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

P1
EIP-2000 Quick Start
V1.0, February 2023
Packing List
In addition to this guide, the package includes the following items:
EIP
-
2000
Quick Start
Screw Driver
CN-1824
EIP-2019/S Only
Technical Support
service@icpdas.com
www.icpdas.com
Resources
How to search for drivers, manuals and
spec information on ICP DAS website.
 For Mobile Web
 For Desktop Web
Installing Software on your PC
Install EIP-2000 Utility:
http://www.icpdas.com/en/download/show.php?num=3080
Model Name
Model Name
P2
Connecting the Power and PC
1. Make sure your PC has workable network settings.
2. Disable or well configure your Windows firewall and anti-virus firewall first,
else the “Network Scan” may not work. (Please contact with your system
Administrator)
3. Check Init/Run DIP switch if it is on Run position.
4. Connect both the EIP-2000 and your computer to the same sub network or
the same Ethernet switch, and power the EIP-2000 on.
P3
5. Please download the datasheet from the ICPDAS website for more
pin-assignment and wire-connection details. The LED indicator table is
shown in the following table.
LED Indicator
LED LED Status Description
Power LED
Always On Module is in Run mode.
Flashing Module is in Init mode.
Status LED
Always On EtherNet/IP connection is failed.
Blink per second
EtherNet/IP connection is successful.
Blink per 300 ms
EtherNet/IP disconnected during
communication but still in Safe-Delay
time.
Blink per 100 ms
Module is about to reboot.
I/O status
LED
On The DI/DO is activated.
Off The DI/DO is inactivated.
EIP-2000 Utility
1. Double click the EIP-2000 Utility shortcut on the desktop.
2. The factory default IP address of the EIP-2000 modules.
Network Settings
Item Settings (default)
IP 192.168.255.1
Gateway 192.168.0.1
Mask 255.255.0.0
3. Click the “Network Scan” button to search your EIP-2000 modules. Or
check "IP Address" to enter the IP address of the module, and then click
the "Configure" button.
P4
4. Users can edit the “Network Settings” for changing the modules’s IP
address. And click the “Update Network Settings” button to update the
configuration and reboot the module.
How to connect with Allen-Bradley PLC?
1. Open RSLogix 5000 (AB PLC tool) and create a new project, and create a
new module in the “Ethernet” item.
P5
2. Set the parameters of the new module. The input assembly instain is 101,
the output assembly instance is 102 and the configuration assembly
instance is 100.
Please find the IO size from the following tables, and the configuration
size is always 0.
 EIP-2017 data size
Data
Assembly
Byte
count
Description
Input
Assembly
53
1st~16th Byte: AI status (AI0~AI7) for DIFF. or S.E. mode.
17th~32nd Byte: AI status (AI8~AI15) for S.E. mode only.
33rd~40th Byte: AI Type Code ( AI0~AI7) for DIFF. or S.E.
mode.
41st~48th Byte: AI Type Code (AI0~AI7) for S.E. mode
only.
49th Byte: AI filters status.
50th Byte: Channel mode status.
51st Byte: AI representation.
52nd Byte: Channel selection (AI0~AI7).
53rd Byte: Channel selection (AI8~AI15).
Output
Assembly
22 1st Byte: Set value to the module.
2nd~17th Byte: Set type code to AI0~AI15.
P6
18th Byte: Filter selections of AI
19th Byte: Channel mode selection DIFF. or S.E.
20th Byte: AI representations
21st Byte: AI channel selection (AI0~AI7)
22nd Byte: AI channel selection (AI8~AI15)
 EIP-2019 data size
Data
Assembly
Byte
count
Description
Input
Assembly
41
1st~16th Byte: AI status(AI0~AI7).
17th~18th Byte: The broken wire status.
19th~20th Byte: CJC status.
21st~28th Byte: AI type code(AI0~AI7).
29th Byte: AI filter status.
30th Byte: AI representation.
31st Byte: Wire break detector.
32nd Byte: CJC switch.
33rd Byte: CJC increment.
34th~41st Byte: CJC offset(AI0~AI7).
Output
Assembly
23
1st Byte: Set value to the module.
2nd~9th Byte: Set type code to Ch0~Ch7.
10th Byte: Filter selection of AI
11st Byte: Wire break detector
12nd Byte: AI representation
13rd Byte: Select AI channel to be short
14th Byte: CJC switch
15th Byte: CJC increment
16th~23rd Byte: CJC Offset
P7
 EIP-2042 data size
Data Assembly Byte count
Description
Input Assembly 2 1st Byte: DO status read back (DO0~DO7).
2nd Byte: DO status read back (DO8~DO15).
Output Assembly
2 1st Byte: DO status (DO0~DO7).
2nd Byte: DO status (DO8~DO15).
 EIP-2051 data size
Data Assembly Byte count
Description
Input Assembly 66
1st Byte: DI status(DI0~DI7).
2nd Byte: DI status(DI8~DI15).
3rd~65th Byte: DI counters.
Output Assembly
2 1st Byte: to set DI counters zero (DI0~DI7).
2nd Byte: to set DI counters zero (DI8~DI15).
 EIP-2055 data size
Data Assembly Byte count
Description
Input Assembly 34
1st Byte: DI status.
2nd Byte: DO status read back
3rd~34th Byte: DI counters.
Output Assembly
2 1st Byte: DO status.
2nd Byte: to set DI counters zero.
 EIP-2060 data size
Data Assembly Byte count
Description
Input Assembly 26
1st Byte: DI status.
2nd Byte: DO status read back
3rd~26th Byte: DI counters.
Output Assembly
2 1st Byte: DO status.
2nd Byte: to set DI counters zero.
P8
The Instance ID of the EIP-2000 module.
Implicit Message Information of EIP-2000
Instance Instance ID Data length
Input(T->O) 65hex (101) Depends on modules.
Output(O->T) 66hex (102) Depends on modules.
Configuration 64hex (100)