manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ICP DAS USA
  6. •
  7. I/O System
  8. •
  9. ICP DAS USA EIP-2000 Series User manual

ICP DAS USA EIP-2000 Series User manual

Other manuals for EIP-2000 Series

2

Other ICP DAS USA I/O System manuals

ICP DAS USA SG-3071 User manual

ICP DAS USA

ICP DAS USA SG-3071 User manual

ICP DAS USA WP-5238-CE7 User manual

ICP DAS USA

ICP DAS USA WP-5238-CE7 User manual

ICP DAS USA I-3591 User manual

ICP DAS USA

ICP DAS USA I-3591 User manual

ICP DAS USA HRT-711 User manual

ICP DAS USA

ICP DAS USA HRT-711 User manual

ICP DAS USA PCI-P8R8 User manual

ICP DAS USA

ICP DAS USA PCI-P8R8 User manual

ICP DAS USA I-7052 User manual

ICP DAS USA

ICP DAS USA I-7052 User manual

ICP DAS USA IR-210 User manual

ICP DAS USA

ICP DAS USA IR-210 User manual

ICP DAS USA I-7021 User manual

ICP DAS USA

ICP DAS USA I-7021 User manual

ICP DAS USA DB-16R User manual

ICP DAS USA

ICP DAS USA DB-16R User manual

ICP DAS USA ET-8KP4-MTCP User manual

ICP DAS USA

ICP DAS USA ET-8KP4-MTCP User manual

ICP DAS USA PCI-P16POR16U User manual

ICP DAS USA

ICP DAS USA PCI-P16POR16U User manual

ICP DAS USA I-7530A-MR-FD User manual

ICP DAS USA

ICP DAS USA I-7530A-MR-FD User manual

ICP DAS USA ISO-C64 User manual

ICP DAS USA

ICP DAS USA ISO-C64 User manual

ICP DAS USA PIO-DA4 User manual

ICP DAS USA

ICP DAS USA PIO-DA4 User manual

ICP DAS USA ET-2254 User manual

ICP DAS USA

ICP DAS USA ET-2254 User manual

ICP DAS USA A-821PGH Series User manual

ICP DAS USA

ICP DAS USA A-821PGH Series User manual

ICP DAS USA SG-3071 User manual

ICP DAS USA

ICP DAS USA SG-3071 User manual

ICP DAS USA I-7050 User manual

ICP DAS USA

ICP DAS USA I-7050 User manual

ICP DAS USA CAN-2024C User manual

ICP DAS USA

ICP DAS USA CAN-2024C User manual

ICP DAS USA WF-2000 Series User manual

ICP DAS USA

ICP DAS USA WF-2000 Series User manual

ICP DAS USA I-7065BD User manual

ICP DAS USA

ICP DAS USA I-7065BD User manual

ICP DAS USA PISO-813 User manual

ICP DAS USA

ICP DAS USA PISO-813 User manual

ICP DAS USA I-7050D User manual

ICP DAS USA

ICP DAS USA I-7050D User manual

ICP DAS USA ET-2255U User manual

ICP DAS USA

ICP DAS USA ET-2255U User manual

Popular I/O System manuals by other brands

SMC Networks EX600-AXA Installation & maintenance manual

SMC Networks

SMC Networks EX600-AXA Installation & maintenance manual

Siemens SIMATIC ET 200SP HA Equipment manual

Siemens

Siemens SIMATIC ET 200SP HA Equipment manual

Advantech PCM-27J3AU Startup manual

Advantech

Advantech PCM-27J3AU Startup manual

Hitachi HX-RIO3 Series user manual

Hitachi

Hitachi HX-RIO3 Series user manual

IFM AL1200 operating instructions

IFM

IFM AL1200 operating instructions

Allen-Bradley D Series installation instructions

Allen-Bradley

Allen-Bradley D Series installation instructions

Allen-Bradley 1794-OF8IH installation instructions

Allen-Bradley

Allen-Bradley 1794-OF8IH installation instructions

Allen-Bradley SLC 500 1746-FIO4I user manual

Allen-Bradley

Allen-Bradley SLC 500 1746-FIO4I user manual

WAGO I/O-SYSTEM 750 manual

WAGO

WAGO I/O-SYSTEM 750 manual

System Sensor M201E installation instructions

System Sensor

System Sensor M201E installation instructions

M-system R7D-YV2A instruction manual

M-system

M-system R7D-YV2A instruction manual

NTP Technology Penta 721 digital I/O installation guide

NTP Technology

NTP Technology Penta 721 digital I/O installation guide

Bosch B208 user manual

Bosch

Bosch B208 user manual

Acces I/O products MPCIE-ISODIO-16 Hardware manual

Acces I/O products

Acces I/O products MPCIE-ISODIO-16 Hardware manual

ExpertDAQ EX-9017F Operation manual

ExpertDAQ

ExpertDAQ EX-9017F Operation manual

SeaLevel SeaI/O-580E user manual

SeaLevel

SeaLevel SeaI/O-580E user manual

Technosoft iPOS360x MX Technical reference

Technosoft

Technosoft iPOS360x MX Technical reference

National Instruments 776570-00 user manual

National Instruments

National Instruments 776570-00 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

P1
EIP-2000 Quick Start
V1.0, February 2023
Packing List
In addition to this guide, the package includes the following items:
EIP
-
2000
Quick Start
Screw Driver
CN-1824
EIP-2019/S Only
Technical Support
service@icpdas.com
www.icpdas.com
Resources
How to search for drivers, manuals and
spec information on ICP DAS website.
 For Mobile Web
 For Desktop Web
Installing Software on your PC
Install EIP-2000 Utility:
http://www.icpdas.com/en/download/show.php?num=3080
Model Name
Model Name
P2
Connecting the Power and PC
1. Make sure your PC has workable network settings.
2. Disable or well configure your Windows firewall and anti-virus firewall first,
else the “Network Scan” may not work. (Please contact with your system
Administrator)
3. Check Init/Run DIP switch if it is on Run position.
4. Connect both the EIP-2000 and your computer to the same sub network or
the same Ethernet switch, and power the EIP-2000 on.
P3
5. Please download the datasheet from the ICPDAS website for more
pin-assignment and wire-connection details. The LED indicator table is
shown in the following table.
LED Indicator
LED LED Status Description
Power LED
Always On Module is in Run mode.
Flashing Module is in Init mode.
Status LED
Always On EtherNet/IP connection is failed.
Blink per second
EtherNet/IP connection is successful.
Blink per 300 ms
EtherNet/IP disconnected during
communication but still in Safe-Delay
time.
Blink per 100 ms
Module is about to reboot.
I/O status
LED
On The DI/DO is activated.
Off The DI/DO is inactivated.
EIP-2000 Utility
1. Double click the EIP-2000 Utility shortcut on the desktop.
2. The factory default IP address of the EIP-2000 modules.
Network Settings
Item Settings (default)
IP 192.168.255.1
Gateway 192.168.0.1
Mask 255.255.0.0
3. Click the “Network Scan” button to search your EIP-2000 modules. Or
check "IP Address" to enter the IP address of the module, and then click
the "Configure" button.
P4
4. Users can edit the “Network Settings” for changing the modules’s IP
address. And click the “Update Network Settings” button to update the
configuration and reboot the module.
How to connect with Allen-Bradley PLC?
1. Open RSLogix 5000 (AB PLC tool) and create a new project, and create a
new module in the “Ethernet” item.
P5
2. Set the parameters of the new module. The input assembly instain is 101,
the output assembly instance is 102 and the configuration assembly
instance is 100.
Please find the IO size from the following tables, and the configuration
size is always 0.
 EIP-2017 data size
Data
Assembly
Byte
count
Description
Input
Assembly
53
1st~16th Byte: AI status (AI0~AI7) for DIFF. or S.E. mode.
17th~32nd Byte: AI status (AI8~AI15) for S.E. mode only.
33rd~40th Byte: AI Type Code ( AI0~AI7) for DIFF. or S.E.
mode.
41st~48th Byte: AI Type Code (AI0~AI7) for S.E. mode
only.
49th Byte: AI filters status.
50th Byte: Channel mode status.
51st Byte: AI representation.
52nd Byte: Channel selection (AI0~AI7).
53rd Byte: Channel selection (AI8~AI15).
Output
Assembly
22 1st Byte: Set value to the module.
2nd~17th Byte: Set type code to AI0~AI15.
P6
18th Byte: Filter selections of AI
19th Byte: Channel mode selection DIFF. or S.E.
20th Byte: AI representations
21st Byte: AI channel selection (AI0~AI7)
22nd Byte: AI channel selection (AI8~AI15)
 EIP-2019 data size
Data
Assembly
Byte
count
Description
Input
Assembly
41
1st~16th Byte: AI status(AI0~AI7).
17th~18th Byte: The broken wire status.
19th~20th Byte: CJC status.
21st~28th Byte: AI type code(AI0~AI7).
29th Byte: AI filter status.
30th Byte: AI representation.
31st Byte: Wire break detector.
32nd Byte: CJC switch.
33rd Byte: CJC increment.
34th~41st Byte: CJC offset(AI0~AI7).
Output
Assembly
23
1st Byte: Set value to the module.
2nd~9th Byte: Set type code to Ch0~Ch7.
10th Byte: Filter selection of AI
11st Byte: Wire break detector
12nd Byte: AI representation
13rd Byte: Select AI channel to be short
14th Byte: CJC switch
15th Byte: CJC increment
16th~23rd Byte: CJC Offset
P7
 EIP-2042 data size
Data Assembly Byte count
Description
Input Assembly 2 1st Byte: DO status read back (DO0~DO7).
2nd Byte: DO status read back (DO8~DO15).
Output Assembly
2 1st Byte: DO status (DO0~DO7).
2nd Byte: DO status (DO8~DO15).
 EIP-2051 data size
Data Assembly Byte count
Description
Input Assembly 66
1st Byte: DI status(DI0~DI7).
2nd Byte: DI status(DI8~DI15).
3rd~65th Byte: DI counters.
Output Assembly
2 1st Byte: to set DI counters zero (DI0~DI7).
2nd Byte: to set DI counters zero (DI8~DI15).
 EIP-2055 data size
Data Assembly Byte count
Description
Input Assembly 34
1st Byte: DI status.
2nd Byte: DO status read back
3rd~34th Byte: DI counters.
Output Assembly
2 1st Byte: DO status.
2nd Byte: to set DI counters zero.
 EIP-2060 data size
Data Assembly Byte count
Description
Input Assembly 26
1st Byte: DI status.
2nd Byte: DO status read back
3rd~26th Byte: DI counters.
Output Assembly
2 1st Byte: DO status.
2nd Byte: to set DI counters zero.
P8
The Instance ID of the EIP-2000 module.
Implicit Message Information of EIP-2000
Instance Instance ID Data length
Input(T->O) 65hex (101) Depends on modules.
Output(O->T) 66hex (102) Depends on modules.
Configuration 64hex (100)