To shut down the boiler
1. For short periods
Set the mains ON/OFF switch (A) to OFF
2. For longer periods
Set the mains ON/OFF switch (A) to OFF, and switch the
electricity supply to OFF. For longer periods the entire system
should be drained.
To relight the boiler
Repeat the procedure detailed in 'To light the boiler'.
Frost protection
If no frost protection is provided and frost is likely during a short
absence from home, leave the heating controls (if fitted) at a
reduced temperature setting. For longer periods, the entire
system should be drained.
If the system includes a frost thermostat then, during cold
weather, the boiler should be turned OFF at the time switch (if
fitted) ONLY. The mains supply should be left switched ON, with
the boiler thermostat left in the normal running position.
Boiler overheat thermostat
This thermostat will shut down the boiler in the event of
overheating. Should this occur a fault code
will be displayed.
Press the reset button (D) and the boiler will relight.
If the fault recurs, turn off the boiler and consult a CORGI
registered installer or in IE a competent person.
Flame failure
Should this occur a fault code will be displayed.
Press the rest button (D) and the boiler will relight.
If the fault recurs, turns off the boiler and consult a CORGI
registered installer or in IE a competent person.
Loss of system water pressure
The gauge (H) indicates the central heating system pressure. If
the pressure is seen to fall below the original installation
pressure of 1-2 bar over a period of time then a water leak is
indicated. In this event a CORGI registered installer or in IE a
competent person should be consulted.
DO NOT FIRE THE BOILER IF THE PRESSURE HAS
REDUCED TO ZERO FROM THE ORIGINAL SETTING.
Condensate Drain
The condensate drain (G) must not be modified or blocked.
Blockage of the condensate drain, caused by debris or freezing,
can cause automatic shutdown of the boiler.
If freezing is suspected and the pipe run is accessible an attempt
may be made to free the obstruction by pouring hot water over
the exposed pipe and clearing any blockage from the end of the
pipe. If this fails to remedy the problem the assistance of a
CORGI registered installer or in IE a competent person should
be sought.
Escape of gas
Should a gas leak or fault be suspected contact your local gas
supplier without delay.
Do NOT search for gas leaks with a naked flame.
Cleaning
For normal cleaning simply dust with a dry cloth.
To remove stubborn marks and stains, wipe with a damp cloth
and finish off with a dry cloth.
DO NOT use abrasive cleaning materials.
Maintenance
The appliance should be serviced at least once a year by a
CORGI registered installer or in IE a competent person.
Ideal Consumer Helpline
Tel: 01482 498 660
www.idealboilers.com
May 2003 UIN 156 411 A02
Ideal Boilers
,
P.O. Box 103, National Ave, Kingston upon Hull, HU5
4JN. Telephone: 01482 492 251 Fax: 01482 448 858. Registration
No. London 322 137.
Caradon Ideal Limited pursues a policy of continuing
improvement in the design and performance of its products. The
right is therefore reserved to vary specification without notice.
The code of practice for the installation,
commissioning & servicing of central heating systems
Caradon Ideal Limited. is a member of the Benchmark initiative and
fully supports the aims of the programme. Benchmark has been
introduced to improve the standards of installation and commissioning
of central heating systems in the UK and to encourage the regular
servicing of all central heating systems to ensure safety and efficiency.
CERTIFIED PRODUCT
Manufactured under a BS EN ISO 9001:1994
Quality System accepted by BSI