QHA210
10
7 Set-up
When the operating voltage has been applied, the moneo|appliance functions according to the factory
settings. The LEDs show the status of the devices and of the interfaces.
7.1 Requirements
For the moneo|appliance set-up, the following components are required.
• Monitor with display port
• Keyboard with USB connection
7.2 Preparations
uConnect the monitor to the display port.
uConnect the keyboard to the USB port.
uConnect the mains plug.
uConnect the network cable.
1. Ethernet interface A (designation on the device) / ETH 1 (designation AMS) - sensor network
2. Ethernet interface B (designation on the device) / ETH 2 (designation AMS) - IT network
moneo|appliance
Ethernet interface Labelling on the de-
vice Description Standard IP address Subnet mask
ETH1 A Sensor network 192.168.0.100 255.255.255.0
ETH2 B IT network DHCP DHCP
Once the operating voltage has been applied, the moneo|appliance can be switched on via the on/off
switch on the front of the device. Make sure that all cables have been connected according to the
description.
7.3 Set-up of moneo|appliance
The initial set-up of the moneo|appliance is made via the connected keyboard and the monitor.
The different menu items in the appliance management system can be selected using the
keyboard. Example: The keyboard shortcut [C] opens [C) Configure the system].
uStart the moneo|appliance.
wThe text "welcome to moneo appliance” is displayed on the monitor.
uEnter the login details and confirm with [Enter].
There is no visible feedback on the monitor for the input. For example, no ***** is displayed in
the input field. The field on the monitor remains empty despite input.
User name: administrator
Password: < serial number of moneo|appliance >
The serial number is provided on the product label on the bottom of the moneo|appliance.
wIf the login details are correct, the [Simple keyboard configuration menu] appears.
uSelect the corresponding keyboard layout and confirm by clicking on [Ok].
uConfirm the successful change by clicking on [Ok].