EJX110ALevelTransmitterInstallationGuide
SelectingaTransmitter&CalculatingYourRange
Transmittersarerangedin‘mmWG’–whichis
shortfor‘MillimetersWaterGauge’.
1mmWGisthepressureof1mmofwateronyour
transmitter.
Sowhenusedonwater,a1mtankwillrequirea
transmitterthatcanread0‐1000mmWG.
Lighterliquidsprovidelesspressurepermm‐to
calculatethecorrectscaleforyourtransmitter,
multiplytheHdimensionbythespecificgravityof
yourliquid.Forexample,tocalculatetherangeon
atransmitterusedona1mtankofdiesel,you
wouldmultiplytheheight(1000mm)bytheSG
(0.7)togetaneffectiverangeof0‐700mmWG.
For0‐1000mmWG,usealowrangetransmitter‐EJX110A‐DLS4G‐924EB/SU2
Forover1000mmWG,useamediumrangetransmitter–EJX110A‐DMS4G‐924EB/SU2
Installation
Yourtransmittermustconnectedtoatappingpointthatisascloseaspossibletothebottomofyourtank,as
thetransmittercanonlyreadthevolumeofliquidaboveit.
Youcanconnectitdirectlytothetappingpoint,orconnectitviapipework.However,thepipeworkmustalso
leaddownwardsandmustnotcontainanyloops.
PLEASENOTE:The‘H1’dimension(thedistancefromthetappingpointtothetransmitter)maynotexceedthe
‘H’dimension(theheightofthetank).
HIGH LOW
THE AREA BELOW THE TAPPING POINT IS UNREADABLE
DP TRANSMITTER
NOTE THE ‘HIGH’ AND ‘LOW’ SIDES
H-MAXTANKLEVEL H1- PTX OFFSET