- 10 -
LMR
Fig.1
T Thin
M Thick
B Thin
Fig.2
Thin
Thick
Fig.3
Thick
LMR
1-26. FOCUS [PWB-MAIN]
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
Receive a green cross-hatch signal of MODE 5.
Adjust FO US-A VR of T501 (FBT) to make the vertical lines sharpest at
points L, M and R as shown in Fig 1.
Adjust FO US-B VR of the T501 to make the horizontal center line
sharpest at points L, M and R as shown in Fig. 1.
If the focus at points T and M is as shown in Fig. 2, adjust VR503 (V-DBF)
to make the horizontal lines have the same thickness at points T, M and
B. And adjust the FO US-B VR again to make the horizontal lines sharpest
at points T, M and B. (VR503 should not be adjusted when focus at points
T and M is optimum.)
If the focus at points L and M is as shown in Fig. 3 or vice versa, adjust
DBF-Para to make the horizontal center line have the same thickness at
points L, M and R. And adjust the FO US-B VR again to make the
horizontal center line sharpest at points L, M and R. (DBF-Para should
not be adjusted when focus at points L and M is optimum.)
Repeat 2) to 5) until the focus is optimum.
onfirm no focus variation on the entire screen.
heck the focus with red and blue respectively.
Receive a H-character signal and repeat 7).
Repeat the FO US adjustments until the focus with red, green and blue
is optimum.
1-25. RASTER REGULATION (DYNAMIC) confirmation
1)
2)
3)
4)
5)
Receive an entire white signal of MODE 5.
Set the input signal by the signal generator as follows:
V-DISP-TIME: 150 V-POSI-TIME: 450
Maximize the brightness or set the signal level to 0.9Vp-p by the signal
generator.
onfirm that <W of the right hand side figure is 1.0mm or less when
turning the luminance volume on the signal generator to the maximum
and “1” respectively.
Return the brightness to center indication.
n
n
FOCUS-A
FOCUS-B
SCREEN
T501(FBT)
Back-raster
Picture
W
Focus
VR503 V-DBF
1-24. V-CONVERGENCE confirmation
1)
2)
3)
Receive a cross-hatch inverted signal of MODE 5.
Select Auto-da-test3 and press the MENU Button so that the automatic
confirmation program starts.
onfirm that the vertical line is diverged.
n